KSKatia Regina Akemi Sasaki

Katia Regina Akemi Sasaki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Katia Regina Akemi Sasaki has a total of 45 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • An enzymatic glucose biosensor using the BESOI MOSFET

    by L.S. Yojo, R.C. Rangel, P.H. Duarte, K.R.A. Sasaki, J.A. Martino


  • Open Access

    Study of ΒΕSOI MOSFET Reconfigurable Transistor for Biosensing Application

    by L. S. Yojo, R. C. Rangel, K. R. A. Sasaki, J. A. Martino

    The Back Enhanced SOI (BESOI MOSFET) is a planar reconfigurable device, which transistor type (n- or p-type) can be programed by the back-gate bias. This transistor is explored in this paper for biosensing application through numerical simulation, based on the fabricated device experimental results. The permittivity value and the charges inside the biomaterial deposited on the underlap region (between gate and source/drain contacts) influence the BESOI MOSFET drain current. The dimensions of the device were evaluated in order to optimize the sensitivity. Among the studied parameters, the underlap length was the most relevant parameter. For short underlap devices, the fringe electric field from the front gate electrode benefits the permittivity-based sensors, while long underlap length devices have a bigger sensitive area in which the charge-based sensor presented better results. Also, the n-type biased device presented higher sensitivity to positively charged materials, while the p-type biased one presented better result for negatively charged materials. The parameters optimization resulted in one order magnitude improvement of the sensitivity for the permittivity-based sensor, for both n- and p-type. As for the charge-based sensor, the optimized device presented twice as bigger sensitivity for the n-type, and at least eight times improvement for the p-type device. This fact represents an advantage of the BESOI structure as the type of the device can be chosen by the back-gate bias.


  • Study of a Charge-Based Biosensor and Reconfigurability using BESOI MOSFET

    by Leonardo Shimizu Yojo, Ricardo Cardoso Rangel, Katia Regina Akemi Sasaki, Joao Antonio Martino

    Sensors for biological components detection have been attracting attention due to the numerous application possibilities, for instance, the food industry and the point of care health(1). In this context, field-effect-transistors (FET) based sensors bring to the biosensing field: a reduced mass production cost, smaller size, signal processing circuit integration capability and higher sensitivity(2). The back-enhanced-silicon-on-insulator (BESOI) metal-oxide-semiconductor (MOS) FET(3) was developed and fabricated at Integrated System Laboratory (LSI) of University of Sao Paulo (USP), Brazil. One of the main attribute of this device is the reconfigurability, i.e., it can operate as an n-type or as a p-type transistor, depending on the back-gate bias. This work explores the characteristics of the BESOI MOSFET as a charge-based biosensor(4) through numerical simulations, using Synopsys Sentaurus TCAD(5), based on experimental measurements. Figure 1 shows the BESOI schematic profile. Experimental details can be seen in(3). The two underlap regions between the drain and gate electrodes and between the source and gate electrodes are the areas where the biological material of interest is deposited, whose charge concentration (Qoxbio) can affect the drain current conduction (figure 2). The BESOI’s operation principle is based on the back-gate bias (VGB). If VGB is positive (n-type BESOI), electrons are induced at the back interface of the silicon channel (between the silicon and the buried oxide). The carrier layer at the back interface enables the drain current conduction that can be modulated by the front-gate voltage (VGF). A negative enough VGF fully depletes the silicon channel, interrupting the current, whereas a positive enough VGF can induce electrons also at the front interface (between the silicon channel and the gate oxide), decreasing the channel resistance(6). An analogous operation occurs for the p-type BESOI, however, a negative VGB is needed and holes are induced at the back interface. In the figure 2, positive Qoxbio values, VGB=25V and VDS=100mV were used in the n-type BESOI while the p-type was biased with VGB=-25V and VDS=-100mV and negative Qoxbio values were considered. The drain current increased as a function of |Qoxbio| because the biomaterial charges electric field increases the induced carriers in the silicon channel. In order to evaluate the influence of the charge concentration of the biological material and the transistor dimensions on the drain current, the simulations were performed varying Qoxbio, the gate electrode length L, the underlap length LUD, the buried oxide thickness tBOX, the gate oxide thickness tox and the silicon film thickness tSi. The relative permittivity of the electrolyte was set to 80(7) and positive gate oxide effective charges were considered to fit experimental results. A sensitivity parameter was defined in equation 1, adopting the lowest Qoxbio (1x1010q/cm2) curve as the reference. A constant absolute front-gate overdrive voltage |VGT=VGF-VT| of 3V was considered in the calculations in order to compare the results of the n-type and p-type biased devices, where VT is the threshold voltage. Figure 3 shows the sensitivity(S) as a function of each parameter for Qoxbio=1x1012q/cm2. The L parameter presents small influence on the S, once the front-gate electrode length only contributes to alter the channel resistance. The underlap influences on the S because its length LUD modifies the area in which the biological material charges affect the channel. The buried oxide thickness tBOX influences inversely the S as the thicker buried oxide diminishes the electric field effect in the channel due to VGB. The tox and tSi parameters presented different trends for the n-type and p-type biases due to the positive gate oxide effective charges. In the n-type case, the gate oxide charges induce electrons also at the front interface, thus the biomaterial charges affect the front interface conduction and the thinner tox and thicker tSi present higher sensitivity. In the p-type bias, the positive gate oxide charges induce electrons at the front interface, suppressing the front interface conduction. The biomaterial charges affect mostly the carriers at the back interface, thus the thicker tox and thinner tSi present higher sensitivity. This fact also led to a higher sensitivity for p-type BESOI MOSFET than for n-type ones. The sensitivity as a function of the Qoxbio is shown in figure 4, in which negative charges were also considered for the n-type biased and positive charges for the p-type biased devices. The reconfigurable characteristic of the BESOI MOSFET means that it is possible to obtain a higher sensitivity in a single device if the biological material presents positive or negative charges. N-type biasing can be more suitable for detecting positive charges, while p-type biasing may present better sensitivity to negative charges. Figure 1

  • Study of a Charge-Based Biosensor and Reconfigurability using BESOI MOSFET

    by Leonardo Shimizu Yojo, Ricardo Cardoso Rangel, Katia Regina Akemi Sasaki, Joao Antonio Martino

    The Back Enhance (BE) SOI MOSFET is a device whose operation can be tuned by the back gate bias (VGB), i.e., it can act as an n- or p-type MOSFET if VGB is positive or negative enough, respectively. This characteristic was explored in the bio-sensing application, in which a charge-based sensor was studied through simulation. Physical dimensions (gate and underlap lengths, gate oxide, silicon and buried oxide thicknesses) were varied in order to determine the most sensitive case. The buried oxide thickness presented highest variation in the results, showing the importance of the substrate on its operation. The biomaterial charge concentration analysis showed a better sensitivity of the device for positive charges when biased as an n-type transistor, while the p-type bias presented better sensitivity to negative charges. Thus, the versatility of the BESOI MOSFET can be used as an advantage in the field of biosensors.


  • Open Access

    Fabrication and Electrical Characterization of Ultra-Thin Body and BOX (UTBB) Back Enhanced SOI (BESOI) pMOSFET

    by Ricardo Cardoso Rangel, Katia R. A. Sasaki, Leonardo Shimizu Yojo, João Antonio Martino

    This work analyzes the third generation BESOI MOSFET (Back-Enhanced Silicon-On-Insulator Metal-Oxide-Semiconductor Field-Effect-transistor) built on UTBB (Ultra-Thin Body and Buried Oxide), comparing it to the BESOI with thick buried oxide (first generation). The stronger coupling between front and back interfaces of the UTBB BESOI device improves in 67% the current drive, 122% the maximum transconductance and 223% the body factor. Operating with seven times lower back gate bias, the UTBB BESOI MOSFET presented more compatibility with standard SOI CMOS (Complementary MOS) technology than the BESOI with thick buried oxide.


  • Reconfigurable back enhanced (BE) SOI MOSFET used to build a logic inverter

    by Leonardo Yojo, Ricardo C. Rangel, Katia R. A. Sasaki, Joao A. Martino

    This paper reports the characteristics and the operation of the new BE SOI MOSFET used to build a logic inverter for the first time. The main characteristics of this device is its simplicity of fabrication and the reconfigurable behavior, i.e, it can act as a n-type transistor or as a p-type transistor depending on the back gate bias. Furthermore, an inverter circuit was built and the static response was measured. The BE SOI inverter showed a characteristic CMOS inverter curve. Finally, the threshold voltage variation with the silicon and gate oxide thickness is explored in order to find the best inverter circuit design.


  • Is there a kink effect in FDSOI MOSFETs?

    by H. J. Park, M. Bawedin, K. Sasaki, J-A. Martino, S. Cristoloveanu

    Systematic experiments demonstrate the presence of the kink effect even in FDSOI MOSFETs. The back-gate bias controls the kink effect via the formation of a back accumulation channel. The kink is more or less pronounced according to the film thickness and channel length. However, in ultrathin (<;10 nm) and/or very short transistors (L <; 50 nm), the kink is totally absent as a consequence of super-coupling effect. For the first time, thanks to the availability of body contacts, the potential was probed to evidence the role of majority carrier excess during the kink effect onset.


  • Back Enhanced (BE) SOI MOSFET under non-conventional bias conditions

    by L.S Yojo, R.C. Rangel, K.R.A. Sasaki, J.A. Martino

    The aim of this work is to investigate the working principle of the new Back Enhanced (BE) SOI MOSFET, under non-conventional bias conditions. This planar BE SOI device with undoped source/drain/channel structure presents the advantage to have very simple fabrication process (without any implantation and electron beam lithography) and can act like a p- or n-type MOS, depending on the back-gate bias condition. Under non-conventional bias condition, many electrical parameters present different behavior. The threshold voltage increases linearly with the drain to source voltage (VDS) if VDS > 0 and it is constant if VDS<;0 in case of p-type BE SOI MOSFET and, analogously, the threshold voltage increases linearly with VDS if it is negative and it is constant if VDS>0 in case of a n-type BE SOI MOSFET. This fact is explained through experimental and simulated data.


  • DIBL in enhanced dynamic threshold operation of UTBB SOI with different drain engineering at high temperatures

    by Katia R. A. Sasaki, Eddy Simoen, Cor Claeys, Joao A. Martino

    Focusing on the DIBL (Drain Induced Barrier Lowering), this paper investigates for the first time the influence of the overlap/underlap gate to drain engineering on UTBB SOI devices in conventional and enhanced dynamic threshold voltage operation at high temperatures. Although the temperature degrades this parameter, the best DIBL performance was obtained for the enhanced mode operation and longer underlap length.