Jie Xiong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jie Xiong has a total of 298 co-authors. Here are the top co-authors by number of shared publications:
- Daqing Zhang
Peking University
21 shared publications - Minhao Cui
Seoul National University, Seoul, Republic of Korea
18 shared publications - Fusang Zhang
Beihang University, Beijing, China
15 shared publications - Lili Qiu
The University of Texas at Austin, Austin, Texas, USA
11 shared publications - Binbin Xie
Department of Computer Science and Engineering, University of Texas at Arlington, Arlington, Texas, USA
10 shared publications - Chi Lin
Dalian University of Technology
9 shared publications
Latest Publications
- Open Access
- 26 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 932-946
When Butterfly Meets Photoacoustic Effect
- 26 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 932-946
Open AccessWhen Butterfly Meets Photoacoustic Effect
- Open Access
- 26 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 84-98
MetaScatter: Enabling High-Order Underwater Backscatter via Piezoelectric Metasurface
- 26 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 84-98
Open AccessMetaScatter: Enabling High-Order Underwater Backscatter via Piezoelectric Metasurface
- Open Access
- 26 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 1756-1758
Demo: When Butterfly Meets Photoacoustic Effect
- 26 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 1756-1758
Open AccessDemo: When Butterfly Meets Photoacoustic Effect
- Open Access
- 26 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 1777-1779
Demo: Phonotonos: Through-Skin Ultrasonic Blood Flow Sensing Using Smartphones
- 26 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 1777-1779
Open AccessDemo: Phonotonos: Through-Skin Ultrasonic Blood Flow Sensing Using Smartphones
- Open Access
- 26 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 1463-1478
General Speech Reconstruction for Voice Calls Using Smartphone's Built-in Accelerometer
- 26 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 1463-1478
Open AccessGeneral Speech Reconstruction for Voice Calls Using Smartphone's Built-in Accelerometer
- Open Access
- 30 September 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (3) , 1-28
One-Shot Gait Recognition Under Arbitrary Trajectories Using a Single WiFi Link
Gait recognition serves as a foundation for numerous applications, ranging from early disease diagnosis to continuous user authentication. While traditional methods rely on cameras or wearables to achieve gait recognition, RF-based solutions have emerged in recent years that better preserve privacy and do not require dedicated wearables or sensors. Among the RF signals explored, WiFi-based solutions are particularly promising due to the ubiquitous deployment of WiFi infrastructure. However, existing WiFi-based methods either require multiple WiFi links or constrain users to walk along predefined trajectories. In addition, they typically require extensive data collection to train the recognition model. These limitations significantly impede the practical deployment and broader adoption of WiFi-based gait recognition systems. In this work, we present WiSiGait, a one-shot gait recognition framework that operates using only a single WiFi link and does not require users to follow any predefined trajectories. To realize WiSiGait, we extract trajectory-independent gait features that can be captured using a single WiFi link. For identification, we explore Siamese neural networks to realize one-shot gait recognition, eliminating the need for extensive pre-training data collection. Extensive experiments demonstrate that our system achieves robust gait recognition across arbitrary trajectories using only a single WiFi link. We believe this work represents a significant step toward the practical deployment of ubiquitous gait recognition. A demo video is available at: https://youtu.be/eTOkG5O3CCE.
- 30 September 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (3) , 1-28
Open AccessOne-Shot Gait Recognition Under Arbitrary Trajectories Using a Single WiFi Link
Gait recognition serves as a foundation for numerous applications, ranging from early disease diagnosis to continuous user authentication. While traditional methods rely on cameras or wearables to achieve gait recognition, RF-based solutions have emerged in recent years that better preserve privacy and do not require dedicated wearables or sensors. Among the RF signals explored, WiFi-based solutions are particularly promising due to the ubiquitous deployment of WiFi infrastructure. However, existing WiFi-based methods either require multiple WiFi links or constrain users to walk along predefined trajectories. In addition, they typically require extensive data collection to train the recognition model. These limitations significantly impede the practical deployment and broader adoption of WiFi-based gait recognition systems. In this work, we present WiSiGait, a one-shot gait recognition framework that operates using only a single WiFi link and does not require users to follow any predefined trajectories. To realize WiSiGait, we extract trajectory-independent gait features that can be captured using a single WiFi link. For identification, we explore Siamese neural networks to realize one-shot gait recognition, eliminating the need for extensive pre-training data collection. Extensive experiments demonstrate that our system achieves robust gait recognition across arbitrary trajectories using only a single WiFi link. We believe this work represents a significant step toward the practical deployment of ubiquitous gait recognition. A demo video is available at: https://youtu.be/eTOkG5O3CCE.
- Open Access
- 30 September 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (3) , 1-32
Towards Doppler-based Long-Duration High-Precision Localization via Distributed WiFi Infrastructure
With the proliferation of WiFi-enabled IoT devices in modern indoor environments, low-cost passive WiFi localization has attracted significant attention. Unlike time-of-flight (ToF) and angle-of-arrival (AoA)-based approaches, which are constrained by limited bandwidth and antenna counts, Doppler-based passive WiFi localization offers higher accuracy and is applicable to a wider range of low-cost commodity devices. However, due to the position dependency of Doppler speed, existing Doppler-based methods rely on an iterative velocity reconstruction process that requires knowledge of the target's initial position and suffers from severe error accumulation. These limitations hinder the practicality of Doppler-based localization in real-world deployments. In this paper, we propose Wi-WeiFuse (WiFi Weighted Fusion), a novel framework that enables Doppler-based, long-duration, and high-precision localization without requiring knowledge of the target's initial position. Instead of relying on velocity reconstruction and treating the position dependency of Doppler speed as a problem to overcome, Wi-WeiFuse leverages this dependency to directly infer position information from multi-link Doppler speeds. To realize Wi-WeiFuse, we propose a spatiotemporal optimization method that ensures precise position estimation despite interference from local optima induced by complex mappings and random noise. To further improve performance, we introduce a weighted multi-link fusion scheme and theoretically derive the optimal weights, ensuring that Wi-WeiFuse is resilient to quality heterogeneity across distributed links. We derive the DSC-Metric as an optimal fusion weight to address the issue of lacking ground-truth measurements required by the theoretically optimal weights. Extensive experiments show that, without requiring knowledge of the target's initial position, Wi-WeiFuse achieves high-precision localization even over trajectories as long as 100 m. When the trajectory length is 15 m, Wi-WeiFuse reduces the localization error to 26.82% of that of the state-of-the-art baseline, and this ratio further decreases to 3.1% in the 100 m long-trajectory setting.
- 30 September 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (3) , 1-32
Open AccessTowards Doppler-based Long-Duration High-Precision Localization via Distributed WiFi Infrastructure
With the proliferation of WiFi-enabled IoT devices in modern indoor environments, low-cost passive WiFi localization has attracted significant attention. Unlike time-of-flight (ToF) and angle-of-arrival (AoA)-based approaches, which are constrained by limited bandwidth and antenna counts, Doppler-based passive WiFi localization offers higher accuracy and is applicable to a wider range of low-cost commodity devices. However, due to the position dependency of Doppler speed, existing Doppler-based methods rely on an iterative velocity reconstruction process that requires knowledge of the target's initial position and suffers from severe error accumulation. These limitations hinder the practicality of Doppler-based localization in real-world deployments. In this paper, we propose Wi-WeiFuse (WiFi Weighted Fusion), a novel framework that enables Doppler-based, long-duration, and high-precision localization without requiring knowledge of the target's initial position. Instead of relying on velocity reconstruction and treating the position dependency of Doppler speed as a problem to overcome, Wi-WeiFuse leverages this dependency to directly infer position information from multi-link Doppler speeds. To realize Wi-WeiFuse, we propose a spatiotemporal optimization method that ensures precise position estimation despite interference from local optima induced by complex mappings and random noise. To further improve performance, we introduce a weighted multi-link fusion scheme and theoretically derive the optimal weights, ensuring that Wi-WeiFuse is resilient to quality heterogeneity across distributed links. We derive the DSC-Metric as an optimal fusion weight to address the issue of lacking ground-truth measurements required by the theoretically optimal weights. Extensive experiments show that, without requiring knowledge of the target's initial position, Wi-WeiFuse achieves high-precision localization even over trajectories as long as 100 m. When the trajectory length is 15 m, Wi-WeiFuse reduces the localization error to 26.82% of that of the state-of-the-art baseline, and this ratio further decreases to 3.1% in the 100 m long-trajectory setting.
- Open Access
- 30 September 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (3) , 1-27
EcoTrack: Enabling Energy-Efficient Millimeter-Accurate Tracking on Commodity UWB Devices
The recent integration of ultra-wideband (UWB) radios into mobile devices has opened the door to a new wave of Internet of Things (IoT) applications. While prior work has primarily focused on improving tracking accuracy, energy constraints in battery-powered mobile devices remain a persistent challenge. We present EcoTrack, a novel uplink phase-based UWB tracking system that significantly reduces energy consumption while still achieving millimeter-level accuracy. EcoTrack optimizes energy consumption by fundamentally redesigning conventional UWB tracking methods through two key strategies: (i) reducing the number of message transmissions and (ii) reducing location update rates. Specifically, departing from conventional methods that rely on multiple message exchanges, we propose an uplink scheme that requires the mobile device to broadcast only a single message for each location update. For accurate phase estimation under unsynchronized multi-anchor scenarios, we propose a two-stage differential operation to cancel the time-varying phase errors in raw phase estimates. While lowering the update rate effectively reduces energy consumption, it also introduces phase ambiguity for target tracking. To tackle this challenge, we fuse wrapped UWB phase with low-power IMU readings widely available on mobile devices to achieve robust ambiguity resolution. Extensive experiments demonstrate that EcoTrack reduces energy consumption by up to 84% compared to existing methods while maintaining a low median 3D tracking error of 0.78 cm across diverse indoor environments.
- 30 September 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (3) , 1-27
Open AccessEcoTrack: Enabling Energy-Efficient Millimeter-Accurate Tracking on Commodity UWB Devices
The recent integration of ultra-wideband (UWB) radios into mobile devices has opened the door to a new wave of Internet of Things (IoT) applications. While prior work has primarily focused on improving tracking accuracy, energy constraints in battery-powered mobile devices remain a persistent challenge. We present EcoTrack, a novel uplink phase-based UWB tracking system that significantly reduces energy consumption while still achieving millimeter-level accuracy. EcoTrack optimizes energy consumption by fundamentally redesigning conventional UWB tracking methods through two key strategies: (i) reducing the number of message transmissions and (ii) reducing location update rates. Specifically, departing from conventional methods that rely on multiple message exchanges, we propose an uplink scheme that requires the mobile device to broadcast only a single message for each location update. For accurate phase estimation under unsynchronized multi-anchor scenarios, we propose a two-stage differential operation to cancel the time-varying phase errors in raw phase estimates. While lowering the update rate effectively reduces energy consumption, it also introduces phase ambiguity for target tracking. To tackle this challenge, we fuse wrapped UWB phase with low-power IMU readings widely available on mobile devices to achieve robust ambiguity resolution. Extensive experiments demonstrate that EcoTrack reduces energy consumption by up to 84% compared to existing methods while maintaining a low median 3D tracking error of 0.78 cm across diverse indoor environments.
- Open Access
- 30 September 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (3) , 1-26
AquaFlicker : Visible Flicker for Motion-Resilient Underwater Optical Communication
Underwater communication supports a wide range of scientific, industrial, and recreational activities. Most existing solutions rely on specialized acoustic or optical hardware. Recent smartphone-based optical approaches improve accessibility, but they remain highly sensitive to blur, motion, and scattering when static spatial visual codes are used. In this work, we revisit smartphone optical camera communication (OCC) for underwater environments. We make a key observation: small-amplitude or high-frequency luminance variations are rapidly attenuated by scattering and haze. In contrast, strong temporal ON/OFF transitions preserve detectable temporal edges across frames, even under motion and optical degradation. Building on this insight, we present AquaFlicker , a smartphone-only underwater OCC system. The system encodes data through deliberate temporal ON/OFF flickering and decodes it using lightweight, motion-aware temporal processing. AquaFlicker enables continuous data streaming without requiring external optics or synchronization hardware. It is designed to tolerate natural hand motion, off-axis viewing, and contrast loss caused by underwater scattering. Extensive experiments show that AquaFlicker sustains communication up to 7-8 m in clear water and remains stable under moderate turbidity conditions. It supports viewing angles up to ±25° and tolerates handheld motion of approximately 15 px/s. Compared with prior smartphone-based approaches, AquaFlicker achieves higher motion tolerance while maintaining end-to-end latency below 200 ms.
- 30 September 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (3) , 1-26
Open AccessAquaFlicker : Visible Flicker for Motion-Resilient Underwater Optical Communication
Underwater communication supports a wide range of scientific, industrial, and recreational activities. Most existing solutions rely on specialized acoustic or optical hardware. Recent smartphone-based optical approaches improve accessibility, but they remain highly sensitive to blur, motion, and scattering when static spatial visual codes are used. In this work, we revisit smartphone optical camera communication (OCC) for underwater environments. We make a key observation: small-amplitude or high-frequency luminance variations are rapidly attenuated by scattering and haze. In contrast, strong temporal ON/OFF transitions preserve detectable temporal edges across frames, even under motion and optical degradation. Building on this insight, we present AquaFlicker , a smartphone-only underwater OCC system. The system encodes data through deliberate temporal ON/OFF flickering and decodes it using lightweight, motion-aware temporal processing. AquaFlicker enables continuous data streaming without requiring external optics or synchronization hardware. It is designed to tolerate natural hand motion, off-axis viewing, and contrast loss caused by underwater scattering. Extensive experiments show that AquaFlicker sustains communication up to 7-8 m in clear water and remains stable under moderate turbidity conditions. It supports viewing angles up to ±25° and tolerates handheld motion of approximately 15 px/s. Compared with prior smartphone-based approaches, AquaFlicker achieves higher motion tolerance while maintaining end-to-end latency below 200 ms.
- Open Access
- 30 September 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (3) , 1-27
Liquid Medicines Identification with mmWave Sensing: From Theory to Practice
Intravenous infusion plays a key role in delivering rapid and effective treatment for patients in critical care settings. However, many intravenous fluids are visually indistinguishable, and their labeling still depends on manual processes performed by nurses. This raises a critical issue: human labeling is prone to errors, and mislabeling of intravenous medications contributes to millions of medical accidents each year. On the other hand, differentiating between visually similar intravenous fluids is non-trivial, requiring intrusive sampling and sophisticated high-end equipment, which is time-consuming, costly, and can lead to medication contamination. In recent years, wireless sensing has gained attention for its non-intrusive capability in liquid identification. However, while it can effectively differentiate between similar liquids such as whole milk and skimmed milk, it still faces challenges in recognizing liquids with low concentrations (e.g., as low as 0.45% in intravenous medications). The problem is further complicated by the diversity of container materials, geometries, and placements. In this paper, we propose MedID, a millimeter wave based solution for intravenous medicine identification. We formulate a double-layer medium reflection model based on Fresnel equations, which analytically describes how the container's permittivity and wall thickness induce periodic spectral variations, while the liquid's permittivity modulates the signal amplitude. Building on this physical foundation, we designed a GAN-based representation learning model that decouples container and liquid features mixed within the radio-frequency signals. We evaluated MedID in a major hospital, encompassing five types of intravenous medications, various infusion bottle materials, and common deviations in bottle placement. All samples were prepared on-site by nurses according to clinical prescriptions and corresponded to the medications actually administered to patients. The results show that the MedID system can non-intrusively identify medications with a recall of 95.42%.
- 30 September 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (3) , 1-27
Open AccessLiquid Medicines Identification with mmWave Sensing: From Theory to Practice
Intravenous infusion plays a key role in delivering rapid and effective treatment for patients in critical care settings. However, many intravenous fluids are visually indistinguishable, and their labeling still depends on manual processes performed by nurses. This raises a critical issue: human labeling is prone to errors, and mislabeling of intravenous medications contributes to millions of medical accidents each year. On the other hand, differentiating between visually similar intravenous fluids is non-trivial, requiring intrusive sampling and sophisticated high-end equipment, which is time-consuming, costly, and can lead to medication contamination. In recent years, wireless sensing has gained attention for its non-intrusive capability in liquid identification. However, while it can effectively differentiate between similar liquids such as whole milk and skimmed milk, it still faces challenges in recognizing liquids with low concentrations (e.g., as low as 0.45% in intravenous medications). The problem is further complicated by the diversity of container materials, geometries, and placements. In this paper, we propose MedID, a millimeter wave based solution for intravenous medicine identification. We formulate a double-layer medium reflection model based on Fresnel equations, which analytically describes how the container's permittivity and wall thickness induce periodic spectral variations, while the liquid's permittivity modulates the signal amplitude. Building on this physical foundation, we designed a GAN-based representation learning model that decouples container and liquid features mixed within the radio-frequency signals. We evaluated MedID in a major hospital, encompassing five types of intravenous medications, various infusion bottle materials, and common deviations in bottle placement. All samples were prepared on-site by nurses according to clinical prescriptions and corresponded to the medications actually administered to patients. The results show that the MedID system can non-intrusively identify medications with a recall of 95.42%.