KBKeith Bethune

Keith Bethune

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Keith Bethune has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Operation of PEMFC Anodes in Dead-Ended Vs. Flow-through Modes

    by Yannick Garsany, Cornelius H. Bancroft, Robert Atkinson Iii, Keith Bethune, Benjamin D. Gould, Karen Swider-Lyons

    Low system complexity and high hydrogen utilization are important attributes for effective proton exchange membrane fuel cells (PEMFCs). Operating a PEMFC with a dead-ended anode (DEA) mode configuration is a simple and effective way to solve these two challenges1, 2. In comparison with the hydrogen flow-through and recirculation mode, in DEA mode the hydrogen supplied to the anode compartment is controlled by pressure regulation instead of a mass flow controller, where a pressure regulator is installed at the anode inlet and a normally closed solenoid valve blocks the outlet. Over time, accumulated water and nitrogen diffused from the cathode are removed by forced gas convection through intermittent opening of the solenoid valve. The anode and cathode gas diffusion media (GDM) play a role in PEMFC water management and have a significant impact on PEMFC performance. We compare an asymmetric GDM pairing with Freudenberg GDM (H24C3 at anode, H23C2 at cathode) to a symmetric GDM pairing frequently used in the open literature containing SGL 29BC at both the anode and cathode, to highlight the impact of the GDM water management on fuel cell operation in flow-through mode and DEA mode. We have previously shown in open-cathode fuel cells that an asymmetric GDM pairing featuring higher porosity in the anode GDM than the cathode significantly improves hydration and power production3, 4. The results at 25% relative humidity (RH) are shown in Figure 1. Consistent with our prior results5, in regular flow-through mode, Figure 1A shows the PEMFC with an asymmetric Freudenberg GDM pairing has significantly higher current densities vs. the PEMFC with symmetric SGL 29BC GDM at an operating cell voltage ≤ 0.60 V. The advantage of using asymmetric GDM observed in flow-through mode is maintained when the PEMFCs are operated in DEA mode (i.e. open symbols). There is only a marginal decrease in cell voltages during operation in DEA mode compared to flow-through mode probably due to the use of dry hydrogen on the anode side during testing in DEA mode. Figure 1B shows that the cell voltage decay is significantly different for a PEMFC containing the symmetric SGL 29BC GDM compared one with asymmetric Freudenberg GDM when tested in DEA mode configuration. The time between purge events is much greater for the asymmetric Freudenberg GDM pairing. The anode is purged with 99.999% H2 when the cell voltage drops by 100 mV. The PEMFC tested with the asymmetric Freudenberg GDM pairing dwells longer at steady-state prior to voltage decay, and its periods of voltage decay are more gradual. The PEMFC containing the symmetric SGL 29BC pairing has a mean purge interval of about 2min 33s and a total of fourteen purge events are necessary over 80 minutes operation, compared to a mean purge interval of about 18min 29s and a total of four purge events are necessary for the PEMFC containing the asymmetric Freudenberg pairing. A longer purge duration is desirable in a fuel cell system because it increases H2 utilization and reduces valve wear. The results show that the asymmetric GDM pairing improves water management in PEMFCs and improves both power density and system level performance. Acknowledgements: The authors are grateful to the Office of Naval Research for support of this research. References I.-S. Han, J. Jeong and H. K. Shin, Int. J. Hydrogen Energy, 38, 11996 (2013). K. Nikiforow, H. Karimäki, T. M. Keränen and J. Ihonen, J. Power Sources, 238, 336 (2013). R. W. Atkinson, M. W. Hazard, J. A. Rodgers, R. O. Stroman and B. D. Gould, J. Electrochem. Soc., 166, F926 (2019). R. W. Atkinson, J. A. Rodgers, M. W. Hazard, R. O. Stroman and B. D. Gould, J. Electrochem. Soc., 165, F1002 (2018). R. W. Atkinson, Y. Garsany, B. D. Gould, K. E. Swider-Lyons and I. V. Zenyuk, ACS Appl. Energy Mater., 1, 191 (2018) Figure 1. (A) Comparison of I-V polarization curves measured for a PEMFC containing a typical symmetric SGL 29BC GDM pairing on the anode and cathode side and a PEMFC containing an asymmetric Freudenberg GDM pairing . Polarization curves are measured in DEA mode and flow-through mode at 25 % RHinlet cathode. In all cases the cell temperature is 65 °C, in H2|air, with air supplied to the cathode a stoichiometric ratio of 2 at atmospheric pressure. During DEA mode, dry H2 is supplied to the anode at 2 psi. (B) Time evolution of the cell voltage obtained at a current density of 1200 mA cm-2 for an H2 inlet pressure of 2 psi and 25 % RHinlet cathode. Figure 1

  • Cathode Catalyst Layer Design with Graded Porous Structure for Proton Exchange Membrane Fuel Cells

    by Yannick Garsany, Robert W. Atkinson, Keith Bethune, Jean St-Pierre, Benjamin D. Gould, Karen Swider-Lyons

    Cathode catalyst layer (CL) design is important for improved performance, durability and stability of proton exchange membrane fuel cells (PEMFCs). An effective cathode CL must serve multiple functions simultaneously: electron and H+ conduction, O2 or H2 supply, and effective water management. The reaction in the CL requires three-phase boundaries (or interfaces) among ionomer (for proton transfer), platinum (for catalysis), and carbon (for electron transfer), as well as voids (reactant diffusion); an optimized cathode CL structure should have micropores and mesopores to balance water egress and O2 diffusion. Our previous research showed that increasing microporosity in the cathode CL increases the power production of the PEMFCs [1]. Modeling indicates that high CL microporosity enhances water evaporation, which reduces mass transport resistances to enable higher power production [2]. Meanwhile, low microporosity encourages liquid water retention. It is known that catalyst support type has a profound effect on electrode porosity, influencing both micro- and mesoporosity [3, 4]. By constructing electrodes with layers of different carbon supported catalyst types, we demonstrate that we can create porosity gradients in the CLs that vary the electrode water management properties and the power of the PEMFC. Two different types of commercial platinum/carbon electrocatalysts are used in dual cathode CLs – 40 wt. % Pt on Vulcan carbon (Pt/VC) having low micropores and low porosity and 40 wt. % Pt on Ketjen black (Pt/KB) having large micropores and high porosity. CLs are created with both homogeneous porosity in the Z direction (Figure 1a), and compared to ones with non-uniform porosity across the Z-direction (Figure 1b). The microstructure of these cathode CLs is characterized using N2-sorption porosimetry. The CLs are assembled into PEMFCs and probed with polarization curves (at 100, 50 and 25% RH), cyclic voltammetry, O2 gain, electrochemical impedance spectroscopy, and limiting current measurements to quantify the sources of mass transport resistance. The results indicate that the regions with low microporosity encourage liquid water retention, while high microporosity encourages water evaporation. These countering actions are balanced for high CL hydration and gas diffusion, and better PEMFC performance. References [1] Y. Garsany, R.W. Atkinson, M.B. Sassin, R.M.E. Hjelm, B.D. Gould, K.E. Swider-Lyons, J. Electrochem. Soc., 165 (2018) F381-F391. [2] M. Eikerling, J. Electrochem. Soc., 153 (2006) E58-E70. [3] T. Soboleva, K. Malek, Z. Xie, T. Navessin, S. Holdcroft, ACS Appl. Mater. Interfaces, 3 (2011) 1827-1837. [4] Y.-C. Park, H. Tokiwa, K. Kakinuma, M. Watanabe, M. Uchida, Journal of Power Sources, 315 (2016) 179-191. Figure 1

  • Performance and Limitations of 3D-Printed Bipolar Plates in Fuel Cells

    by Benjamin D. Gould, Joseph A. Rodgers, Michael Schuette, Keith Bethune, Shaquille Louis, Richard Rocheleau, Karen Swider-Lyons


  • PEMFC Contamination - Fundamentals and Outlook

    by Jean St-Pierre, Michael Angelo, Keith Bethune, Junjie Ge, Scott Higgins, Tatyana V. Reshetenko, Maheboob B.V. Virji, Yunfeng Zhai

    Contamination of proton exchange membrane fuel cells is coming to the forefront as commercialization activities multiply and fuel cell systems are confronted to field conditions away from the controlled laboratory environment. The recent progress achieved in understanding the disruptive effects of contaminants is reviewed. The analysis is focused on contaminant effects, contaminant sources, mechanisms, mitigation strategies and knowledge gaps in all these areas.


  • Performance of 3D-Printed Fuel Cells and Stacks

    by Benjamin D. Gould, Joseph A. Rodgers, Michael Schuette, Keith Bethune, Shaquille Louis, Richard Rocheleau, Karen Swider-Lyons

    Additive manufacturing (AM) is being touted as a possible tool for rapid prototyping fuel cell bipolar plate (BPP) designs. We use the AM method of direct metal laser sintering (DMLS) to make 21 cm2 titanium-alloy BPPs with embedded flow channels. The surface of the BPPs is then polished to the appropriate roughness and coated with a conductive corrosion barrier. The coated BPPs are assembled with the appropriate seals, catalyst coated membranes and gas diffusion layers into a 40-cell stack and tested. The resulting 400 W fuel cell stack power is 20% less than expected because of inadequate flatness of several of the DMLS BPPs as determined by white light profilometry, leading to high contact resistance. While DMLS clearly shows the benefit of being able to make complex flow fields and hollow parts with no welds, more work is needed toward reducing the weight and increasing the flatness of BPPs made by AM.

  • Performance of 3D-Printed Fuel Cells and Stacks

    by Benjamin D. Gould, Joseph A. Rodgers, Michael Schuette, Keith Bethune, Shaquille Louis, Richard Rocheleau, Karen Swider-Lyons

    3D-printing, a.k.a. additive manufacturing (AM), has become a popular topic in the general public and in industry [1]. There is recent interest in using AM to fabricate fuel cell components because of AMs ability to build metal parts with complex geometries with relatively short lead times [2]. Fuel cell bipolar plates (BPPs) require complex internal passageways for coolant flow fields making them a good candidate for AM. By building one piece BPPs the number of parts, the number of seals and the complexity of assembly can be decreased. We present the performance characteristics of a 400W fuel cell system made with BPPs made of Ti-alloy (Ti-6Al-4V) and built by 3D-printing. The BPPs are made by direct metal laser sintering (DMLS) and are coated by Treadstone Inc. with Au-microdots and a TiO2layer to decrease contact resistance and protect against corrosion. Titanium alloy is examined because of its high strength-to-weight ratio which makes it an ideal material for aerospace applications. This work extends our previous work regarding the contact resistance of 3D-printed metal BPPs to include functional fuel cell stacks [3]. The performance characteristics of single cells and stacks will be discussed in the context of surface finish, flatness, feature tolerance, weight, cell-to-cell variability, scaling and contact resistance. Overall DMLS is an exciting new technique with great promise for future rapid prototyping of BPP designs and many other fuel cell components. However, greater advances in surface finish, feature thinness and flatness are needed before BPPs built by 3D-printing will compete with the traditional machined or formed BPPs. References [1] http://techland.time.com/tag/3d-printing/ (2014) [2] http://energy.gov/eere/articles/doe-announces-webinars-natural-gas-biomass-technologies-additive-manufacturing-fuel. (2014) [3] C. J. Netwall, B. D. Gould, J. A. Rodger, N. J. Nasello, K. E. Swider-Lyons, J. Power Sources, 227, 137 (2013).