Vitor Hugo da Silva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Vitor Hugo da Silva has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Claudete Fernandes Pereira
Federal University of Pernambuco (UFPE), Department of Fundamental Chemistry, Recife, PE, Brazil
5 shared publications - Celio Pasquini
Institute of Chemistry, State University of Campinas, Rua Monteiro Lobato, 290, 13083-862, Campinas, SP, Brazil
3 shared publications - Maria Fernanda Pimentel
Department of Chemical Engineering, Federal University of Pernambuco, Av. dos Economistas, Cidade Universitária, s/n, 50.740-590, Recife, PE, Brazil
3 shared publications - Jakob Strand
Department of Bioscience, Aarhus University, Frederiksborgvej 399, DK-4000 Roskilde, Denmark
2 shared publications Alan Rocha Salles
1 shared publication- Alianda Dantas de Oliveira
Universidade Federal de Pernambuco, Brasil
1 shared publication
Latest Publications
- Open Access
A Study of Microplastic Particles in Danish Tap Water
Microplastics (MPs) are omnipresent in our surroundings and in the environment, with drinking water being a potential pathway for human exposure. This study investigated the presence of MPs in Danish drinking water from 17 different households and workplaces in Denmark. Samples of tap water were collected using a closed sampling system to decrease airborne contamination, and QA/QC measurements were performed to assess background contamination. Particles > 100 µm were visually analysed by stereomicroscopy in combination with spectroscopy analysis (µ-FTIR) to evaluate morphology and chemical composition. An assessment of MP particles down to 10 µm was performed on water samples from three locations using hyperspectral image analysis. The results indicate a low level of MPs in Danish drinking water, with a total of seven MP particles across all samples, comprising PET, PP, PS, and ABS. Microfibers were the most common type of MP-like particles in both drinking water and blanks, but the concentration for all samples was below the limit of detection and could not be differentiated from background contamination. Most of the particles analysed by µ-FTIR were identified as cellulose fibres and a smaller subset as protein. Based on this work, we discuss the status of MP drinking water studies and address challenges and limitations regarding the analysis of MP in drinking water.
Open AccessA Study of Microplastic Particles in Danish Tap Water
Microplastics (MPs) are omnipresent in our surroundings and in the environment, with drinking water being a potential pathway for human exposure. This study investigated the presence of MPs in Danish drinking water from 17 different households and workplaces in Denmark. Samples of tap water were collected using a closed sampling system to decrease airborne contamination, and QA/QC measurements were performed to assess background contamination. Particles > 100 µm were visually analysed by stereomicroscopy in combination with spectroscopy analysis (µ-FTIR) to evaluate morphology and chemical composition. An assessment of MP particles down to 10 µm was performed on water samples from three locations using hyperspectral image analysis. The results indicate a low level of MPs in Danish drinking water, with a total of seven MP particles across all samples, comprising PET, PP, PS, and ABS. Microfibers were the most common type of MP-like particles in both drinking water and blanks, but the concentration for all samples was below the limit of detection and could not be differentiated from background contamination. Most of the particles analysed by µ-FTIR were identified as cellulose fibres and a smaller subset as protein. Based on this work, we discuss the status of MP drinking water studies and address challenges and limitations regarding the analysis of MP in drinking water.
- Top Cited Papers
- 18 September 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (20) , 13724-13733
Classification and Quantification of Microplastics (<100 μm) Using a Focal Plane Array–Fourier Transform Infrared Imaging System and Machine Learning
Microplastics are defined as microscopic plastic particles in the range from few micrometers and up to 5 mm. These small particles are classified as primary microplastics when they are manufactured in this size range, whereas secondary microplastics arise from the fragmentation of larger objects. Microplastics are widespread emerging pollutants, and investigations are underway to determine potential harmfulness to biota and human health. However, progress is hindered by the lack of suitable analytical methods for rapid, routine, and unbiased measurements. This work aims to develop an automated analytical method for the characterization of small microplastics (<100 μm) using micro-Fourier transform infrared (μ-FTIR) hyperspectral imaging and machine learning tools. Partial least squares discriminant analysis (PLS-DA) and soft independent modeling of class analogy (SIMCA) models were evaluated, applying different data preprocessing strategies for classification of nine of the most common polymers produced worldwide. The hyperspectral images were also analyzed to quantify particle abundance and size automatically. PLS-DA presented a better analytical performance in comparison with SIMCA models with higher sensitivity, sensibility, and lower misclassification error. PLS-DA was less sensitive to edge effects on spectra and poorly focused regions of particles. The approach was tested on a seabed sediment sample (Roskilde Fjord, Denmark) to demonstrate the method efficiency. The proposed method offers an efficient automated approach for microplastic polymer characterization, abundance numeration, and size distribution with substantial benefits for method standardization.
- 18 September 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (20) , 13724-13733
Top Cited PapersClassification and Quantification of Microplastics (<100 μm) Using a Focal Plane Array–Fourier Transform Infrared Imaging System and Machine Learning
Microplastics are defined as microscopic plastic particles in the range from few micrometers and up to 5 mm. These small particles are classified as primary microplastics when they are manufactured in this size range, whereas secondary microplastics arise from the fragmentation of larger objects. Microplastics are widespread emerging pollutants, and investigations are underway to determine potential harmfulness to biota and human health. However, progress is hindered by the lack of suitable analytical methods for rapid, routine, and unbiased measurements. This work aims to develop an automated analytical method for the characterization of small microplastics (<100 μm) using micro-Fourier transform infrared (μ-FTIR) hyperspectral imaging and machine learning tools. Partial least squares discriminant analysis (PLS-DA) and soft independent modeling of class analogy (SIMCA) models were evaluated, applying different data preprocessing strategies for classification of nine of the most common polymers produced worldwide. The hyperspectral images were also analyzed to quantify particle abundance and size automatically. PLS-DA presented a better analytical performance in comparison with SIMCA models with higher sensitivity, sensibility, and lower misclassification error. PLS-DA was less sensitive to edge effects on spectra and poorly focused regions of particles. The approach was tested on a seabed sediment sample (Roskilde Fjord, Denmark) to demonstrate the method efficiency. The proposed method offers an efficient automated approach for microplastic polymer characterization, abundance numeration, and size distribution with substantial benefits for method standardization.
- 1 January 2019
- Published by Elsevier in European Journal of Pharmaceutics and Biopharmaceutics
- Vol. 134, 20-28
Evaluation of chemometric approaches for polymorphs quantification in tablets using near-infrared hyperspectral images
- 1 January 2019
- Published by Elsevier in European Journal of Pharmaceutics and Biopharmaceutics
- Vol. 134, 20-28
Evaluation of chemometric approaches for polymorphs quantification in tablets using near-infrared hyperspectral images
- Open Access
- 9 August 2018
- Published by FapUNIFESP (SciELO) in Materials Research
- Vol. 21 (5)
Use of Infrared Spectroscopy and Near Infrared Hyperspectral Images to Evaluate Effects of Different Chemical Agents on PET Bottle Surface
PET - poly (ethylene terephthalate) - bottle surfaces were exposed to chemical agents and evaluated with middle infrared spectroscopy (MIR) and near infrared hyperspectral imaging (HSI-NIR). Images (928-2.524 nm) were acquired at different times from bottle surfaces exposed to alkaline, acidic and ethanolic media. Savitzky-Golay smoothing (2nd order polynomial and 5-point window) combined with Standard Normal Variate (SNV) was used for pre-processing data. Scores from principal component analysis (PCA) on images showed discrimination of PET according to exposure time, particularly when employing NaOH. After the first two hours of chemical exposure, significant contribution of the (-C-O + OH) combination band indicated formation of glycol ethylene on the PET surface, which was confirmed from PCA loading plots. MIR reflectance spectra ranged from 4.000 to 650 cm-1. Changes in spectral intensities could be associated with depolymerization of PET when exposed to NaOH. These were confirmed with PCA and attributed to the carboxylate group of terephthalate.
- 9 August 2018
- Published by FapUNIFESP (SciELO) in Materials Research
- Vol. 21 (5)
Open AccessUse of Infrared Spectroscopy and Near Infrared Hyperspectral Images to Evaluate Effects of Different Chemical Agents on PET Bottle Surface
PET - poly (ethylene terephthalate) - bottle surfaces were exposed to chemical agents and evaluated with middle infrared spectroscopy (MIR) and near infrared hyperspectral imaging (HSI-NIR). Images (928-2.524 nm) were acquired at different times from bottle surfaces exposed to alkaline, acidic and ethanolic media. Savitzky-Golay smoothing (2nd order polynomial and 5-point window) combined with Standard Normal Variate (SNV) was used for pre-processing data. Scores from principal component analysis (PCA) on images showed discrimination of PET according to exposure time, particularly when employing NaOH. After the first two hours of chemical exposure, significant contribution of the (-C-O + OH) combination band indicated formation of glycol ethylene on the PET surface, which was confirmed from PCA loading plots. MIR reflectance spectra ranged from 4.000 to 650 cm-1. Changes in spectral intensities could be associated with depolymerization of PET when exposed to NaOH. These were confirmed with PCA and attributed to the carboxylate group of terephthalate.
- 1 August 2018
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 157, 107-115
Comparison of macro and micro Raman measurement for reliable quantitative analysis of pharmaceutical polymorphs
- 1 August 2018
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 157, 107-115
Comparison of macro and micro Raman measurement for reliable quantitative analysis of pharmaceutical polymorphs
- 20 April 2018
- Published by Springer Nature in Food Analytical Methods
- Vol. 11 (10) , 2699-2706
Multivariate Classification of UHT Milk as to the Presence of Lactose Using Benchtop and Portable NIR Spectrometers
- 20 April 2018
- Published by Springer Nature in Food Analytical Methods
- Vol. 11 (10) , 2699-2706
Multivariate Classification of UHT Milk as to the Presence of Lactose Using Benchtop and Portable NIR Spectrometers
- 20 March 2017
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 142 (9) , 1519-1524
Multivariate quantification of mebendazole polymorphs by terahertz time domain spectroscopy (THZ-TDS)
An analytical method based on terahertz-time domain spectroscopy (THz-TDS) and PLS regression models to quantify mebendazole polymorphs in pharmaceutical raw material is presented.
- 20 March 2017
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 142 (9) , 1519-1524
Multivariate quantification of mebendazole polymorphs by terahertz time domain spectroscopy (THZ-TDS)
An analytical method based on terahertz-time domain spectroscopy (THz-TDS) and PLS regression models to quantify mebendazole polymorphs in pharmaceutical raw material is presented.
- 1 February 2017
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 134, 287-294
Portable near-infrared instruments: Application for quality control of polymorphs in pharmaceutical raw materials and calibration transfer
- 1 February 2017
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 134, 287-294
Portable near-infrared instruments: Application for quality control of polymorphs in pharmaceutical raw materials and calibration transfer
- 1 November 2015
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 115, 587-593
Quantitative analysis of mebendazole polymorphs in pharmaceutical raw materials using near-infrared spectroscopy
- 1 November 2015
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 115, 587-593
Quantitative analysis of mebendazole polymorphs in pharmaceutical raw materials using near-infrared spectroscopy
- 1 March 2015
- Published by Elsevier in Fuel Processing Technology
- Vol. 131, 230-237
Determination of naphtha composition by near infrared spectroscopy and multivariate regression to control steam cracker processes
- 1 March 2015
- Published by Elsevier in Fuel Processing Technology
- Vol. 131, 230-237
Determination of naphtha composition by near infrared spectroscopy and multivariate regression to control steam cracker processes