MPMaksim O. Pleshkov

Maksim O. Pleshkov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Maksim O. Pleshkov has a total of 79 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Radiomics in assessing neurosonographic changes in newborns with diabetic fetopathy: analysis of ultrasound images

    by N. D. Zimina, M. O. Pleshkov, A. O. Voshchenko, S. V. Fomina, Yu. G. Samoilova, D. A. Kudlai, E. V. Mitselya, I. V. Tolmachev

    Introduction . Early noninvasive assessment of brain changes in newborns is a significant challenge in pediatrics. This article presents an approach to noninvasive assessment of brain changes in newborns using radiomics analysis of ultrasound images. Radiomics analysis allows characterization of the morphological structure of neurosonographic ultrasound images using a set of texture parameters and the identification of changes invisible to the naked eye. Aim: To investigate the feasibility of using radiomics analysis of ultrasound images to detect brain changes in diabetic fetopathy in newborns. Material and Methods . Data were collected from brain ultrasound images of 89 full-term neonates (gestational age greater than 37 weeks), including 45 (51%) healthy neonates (control group) and 44 (49%) with diabetic fetopathy (study group). Data were extracted using specialized projections to display four locations: Frontal lobe (F0 scan at the level of the anterior sections of both frontal lobes): 45 healthy and 37 patients. Parasagittal section in the choroid plexus area (S2 scan in the parasagittal plane): 41 healthy and 40 patients. Sagittal section in the corpus callosum area (S0 scan in the midsagittal plane): 44 healthy and 40 patients. Frontal section in the periventricular region (F4 scanning in the area of the parietal and temporal lobes, as well as the cerebellum): 45 healthy and 44 patients. Results . When conducting B-mode neurosonography, the same frequency of subependymal cysts and lateral ventricular dilation was observed in both groups (7% vs. 5%; p = 0.53), but intraventricular hemorrhages and periventricular edema were observed only in the main group (7% vs. 0%; p < 0,05). As a result of radiomics analysis of ultrasound images of the brain, radiomics predictors of texture changes in newborns with diabetic fetopathy were established in four localizations. Classification models were built and ROC analysis was performed. The best results were shown by Model 1 for the frontal lobe (accuracy – 0.71, AUC = 0,69) and Model 4 for the periventricular region (accuracy – 0.89, AUC = 0,85). The established textural changes in the brain of newborns with diabetic fetopathy manifest as follows: an uneven, chaotic distribution of echogenicity with multiple hyperechoic areas is observed in the frontal lobe. The periventricular zone exhibits a marked, diffuse increase in echogenicity, creating a homogenized effect on the image. Radiomics analysis of ultrasound images can reveal changes in brain texture that are not detectable with standard neurosonography. Conclusions . Multiparametric analysis of ultrasound images using a radiomics approach demonstrated the ability to detect structural changes in the brain of newborns with diabetic fetopathy. The results confirm the effectiveness of radiomics analysis in identifying subtle neuroanatomical changes.


  • Open Access

    Application of safe surgery technologies in operations on the thyroid-parithoid complex: a clinical case

    by A. S. Motorykin, O. S. Popov, D. S. Titov, M. O. Pleshkov, I. V. Tolmachev, В. И. Стасевский, V. D. Udodov, E. E. Vasilchenko

    Currently, the trend towards an increase in diseases of the thyroid-parathyroid complex continues. 4 to 7% of the world's population have nodular transformation of the thyroid gland. The importance of surgical methods for treating patients with thyroid and parathyroid gland pathology has also increased. Despite significant progress and the introduction of preoperative diagnostic methods, preoperative preparation, and postoperative monitoring, the number of intra- and postoperative complications remains high, which motivates the development and implementation of new original technical solutions in thyroid and parathyroid gland surgery. The article presents a clinical case of successful surgical treatment of a patient with diffuse-nodular transformation of a large thyroid gland with retrosternal location and compression of the neck and mediastinal organs due to the use of existing new and original technical solutions developed in the clinic.

  • Open Access

    Radiomics in application to diseases of the musculoskeletal system: a review

    by Maksim O. Pleshkov, Maria A. Zamyshevskaya, Egor V. Kuchinskii, Xiance Jin, Ji Zhang, Vera D. Zavadovskaya, Maxim A. Zorkaltsev, Tkhe V. Kim, Daria A. Pogonchenkova, Vladimir D. Udodov, et al.

    Radiomics is a technique used to extract numerous quantitative features from digital medical images. A decade ago, this method was applied in oncology, but now it has expanded to non-oncological diseases, particularly those affecting the musculoskeletal system and connective tissues. This article provides an overview of the current advances in radiomics for diagnosing diseases of the musculoskeletal system. In this review, we assessed 37 original research papers published in English between 2020 and 2023. The most commonly used imaging modalities were magnetic resonance imaging (54%) and computed tomography (32%), while dual-energy X-ray absorptiometry (14%), ultrasound (5%), and radiographs (5%) were less frequently used. The majority of the studies apply manual segmentation to identify the regions of interest. Various classification models have been developed that incorporate clinical, radiomics, and deep features, with combined clinical-radiomics models being the most prevalent one. The most commonly affected areas in diseases of the musculoskeletal system were the spine and large joints. The prevalence of the multi-source input models (primarily clinical-radiomics) compared to that of single-source input models (clinical only, radiomics only) for diagnosing diseases of the musculoskeletal system can be explained by the higher classification performance, likely due to the inclusion of a larger number of independent information sources. Although the development of models or deep-learning features for automatic segmentation and classification holds promise, it requires significant efforts in creating image databases for deep model training. Thus, radiomics may be particularly beneficial for the early detection of diseases of the musculoskeletal system that cause pathological changes in the soft tissues, which may not be visible to the naked eye.


  • Open Access

    Radiomics Analysis of Ultrasound Images of Peripheral Nerves in Young Patients with Type 1 Diabetes Mellitus in Comparison with Healthy Controls

    by Svetlana V. Fomina, Iuliia G. Samoilova, Maksim O. Pleshkov, Dmitry А. Kudlay, Еvgeniy А. Voronin, Dmitriy A. Kachanov, Ivan V. Tolmachev, Marina V. Koshmeleva, Ekaterina I. Trifonova, Ю. Г. Самойлова

    Background. Early diagnosis of diabetic polyneuropathy in childhood is an urgent healthcare problem. Radiomics analysis of ultrasound images is a promising diagnostic tool for assessing the morphological structure of peripheral nerves in type 1 diabetes mellitus (T1DM).Objective: to evaluate the possibility of using radiomics analysis in the diagnosis of peripheral nerve changes based on ultrasound images in T1DM patients of young age.Material and methods. A total of 126 ultrasound images of peripheral nerves of the upper and lower limbs in T1DM patients aged 10–17 years (n=10) and controls (n=10) (four locations, greyscale mode) were studied.Results. Radiomics analysis revealed differences in the texture of peripheral nerves of the limbs in young T1DM patients when compared with healthy individuals.Conclusion. The method of radiomics analysis is a promising diagnostic tool for assessing changes in peripheral nerves in children and adolescents with T1DM.


  • In vivo study of porous NiTi cryotweezers for bone tissue cryotherapy

    by Ekaterina S. Marchenko, Kirill M. Dubovikov, Ivan I. Kuzhelivskiy, Maksim O. Pleshkov, Evgeniy S. Koroluk, Konstantin S. Brazovskii, Alex A. Volinsky

  • Open Access

    The application of machine learning and deep learning radiomics in the treatment of esophageal cancer

    by Jinling Yi, Yibo Wu, Boda Ning, Ji Zhang, Maksim Pleshkov, Ivan Tolmachev, Xiance Jin


  • Open Access

    Comparison of EOG and VOG obtained eye movements during horizontal head impulse testing

    by Maksim Pleshkov, Vasilii Zaitsev, Dmitrii Starkov, Vladimir Demkin, Herman Kingma, Raymond van de Berg

    Introduction: Video head impulse testing is frequently used to evaluate the vestibular function. During this test, eye movement responses are recorded with video-oculography (VOG). However, the use of VOG can sometimes be challenging, especially due to pupil detection problems (e.g., blinking, droopy eyelids, etc.). Therefore, this study investigated whether electro-oculography (EOG), a technique that does not depend on pupil tracking but on the orientation of the corneoretinal potential, might be an alternative to VOG for quantifying eye movement responses during head impulse testing.Subjects and methods: Head impulse testing was performed in 19 healthy subjects without a prior history of vestibular symptoms. Horizontal eye movements were recorded simultaneously with EOG (using an EOG system) and VOG (using a VHIT system: ICS Impulse). The eye movement responses to each side of both techniques were compared using a concordance correlation coefficient (rc), t-testing, and Bayes Factor (BF) paired t-testing.Results: EOG and VOG obtained eye movement traces that correlated well with each other during head impulse testing (average rc = 0.89). Average VOR gains obtained with EOG and VOG were not significantly different from each other for all subjects during left head impulses. However, VOG gains differed between both techniques regarding right head impulses. VOG showed significant VOR gain asymmetry (5% to the right), whereas EOG showed no significant asymmetry (1% to the right).Conclusion: This study demonstrated the use of EOG to record eye movements during head impulse testing for the first time. EOG and VOG obtained eye movement traces that correlated well with each other during horizontal head impulse testing. In addition, EOG showed smaller VOR gain asymmetry in healthy individuals, in contrast to VOG. These findings indicate that EOG might potentially be applicable as an alternative to VOG for collecting eye movement responses during head impulse testing.Trial registration number: 10192021-38 dated 19.10.21.


  • Open Access

    Reported thresholds of self-motion perception are influenced by testing paradigm

    by M. Pleshkov, N. Rondas, F. Lucieer, L. van Stiphout, M. Janssen, N. Guinand, A. Perez-Fornos, V. Demkin, V. van Rompaey, H. Kingma, et al.

    Background/objective: Different testing paradigms have been proposed to investigate perceptual self-motion thresholds. They can differ regarding the amount of possible motions that patients have to choose from. Objective of this study was to compare the two-option paradigm and twelve-option paradigm, to investigate whether reducing the choice options significantly influences the reported thresholds of self-motion perception of healthy subjects. Methods: Thirty-three volunteers with no prior vestibular complaints were included and sequentially tested with both paradigms at a random sequence. Perceptual self-motion thresholds were measured using a hydraulic motion platform in the absence of external visual and auditory cues. The platform delivered twelve different movements: six translations and six rotations. Each subject had to report the correct type and direction of movements. Thresholds were determined by a double confirmation of the lowest threshold, in combination with a double rejection of the one-step lower stimulus. Perceptual self-motion thresholds of both paradigms were compared using the mixed model analysis. Results: The twelve-option paradigm showed significantly higher reported thresholds for yaw rotations and translations left, right and down (p < 0.001), compared to the two-option paradigm. No statistical difference was found for rolls and translations up. No significant gender effect, learning effect and carry-over effect were present in any of the applied motion directions. Conclusion: Reported thresholds of self-motion perception of healthy subjects are influenced by the testing paradigm. The twelve-option paradigm showed significantly higher thresholds than the two-option paradigm. Results obtained with each testing paradigm should, therefore, be compared to paradigm-specific normative data.


  • Open Access

    Fitting the determined impedance in the guinea pig inner ear to Randles circuit using square error minimization in the range of 100 Hz to 50 kHz

    by M O Pleshkov, S D’aLessandro, M V Svetlik, D N Starkov, V A Zaitsev, M Handler, D Baumgarten, R Saba, R van de Berg, V P Demkin, et al.

    Objective. Several lumped and distributed parameter models of the inner ear have been proposed to improve vestibular implant stimulation. The models should account for all significant physical phenomena that influence the current propagation, such as the electrical double layer (EDL) and medium polarization. The electrical properties of the medium are reflected in the electrical impedance; therefore, the study aimed to measure the impedance in the guinea pig inner ear and construct its equivalent circuit. Approach. The electrical impedance was measured from 100 Hz to 50 kHz between a pair of platinum electrodes immersed in 0.9% NaCl saline solution using sinusoidal voltage signals. The Randles circuit was fitted to the measured impedance in the saline solution in order to estimate the EDL parameters ( C , W , a n d R c t ) of the electrode interface in saline. Then, the electrical impedance was measured between all combinations of the electrodes located in the semicircular canal ampullae and the vestibular nerve in the guinea pig in vitro. The extended Randles circuit considering the medium polarization ( R i , R e , C m ) together with EDL parameters ( C , R c t ) obtained from the saline solution was fitted to the measured impedance of the guinea pig inner ear. The Warburg element was assumed negligible and was not considered in the guinea pig model. Main results. For the set-up used, the obtained EDL parameters were: C = 27.09 * 10 − 8 F , R c t = 18.75 k Ω . The average values of intra-, extracellular resistances, and membrane capacitance were R i = 4.74 k Ω , R e = 45.05 k Ω , C m = 9.69 * 10 − 8 F , respectively. Significance. The obtained values of the model parameters can serve as a good estimation of the EDL for modelling work. The EDL, together with medium polarization, plays a significant role in the electrical impedance of the guinea pig inner ear, therefore, they should be considered in electrical conductivity models to increase the credibility of the simulations.