Darryl John Burstow
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Darryl John Burstow has a total of 301 co-authors. Here are the top co-authors by number of shared publications:
- David Gerard Platts
Department of Echocardiography, The Prince Charles Hospital, Brisbane, Queensland, Australia
32 shared publications - Christian Hamilton-Craig
Faculty of Medicine, University of Queensland, Brisbane, QLD 4072, Australia
13 shared publications Darren L. Walters
The Prince Charles Hospital, Echocardiography Laboratory, Cardiac Sciences Unit, Brisbane, Australia
11 shared publicationsGregory M. Scalia
Department of Echocardiography, The Prince Charles Hospital, Brisbane, Queensland, Australia
10 shared publications- Gregory Michael Scalia
The Prince Charles Hospital, Brisbane, Australia
9 shared publications - John Sedgwick
The Prince Charles Hospital, Brisbane, Qld, Australia
9 shared publications
Latest Publications
- Open Access
- 10 November 2022
- Published by Wiley in Critical Care Research and Practice
- Vol. 2022, 1-9
The Prognostic Value of Echocardiographic Wall Motion Score Index in ST-Segment Elevation Myocardial Infarction
Background. When compared to left ventricular ejection fraction (LVEF), previous studies have suggested the superiority of wall motion score index (WMSI) in predicting cardiac events in patients who have suffered acute myocardial infarction. However, there are limited studies assessing WMSI and mortality in ST-segment elevation myocardial infarction (STEMI). We aimed to compare the prognostic value of WMSI in a cohort of STEMI patients treated with primary percutaneous coronary intervention (PCI). Methods. A comparison of WMSI, LVEF, and all-cause mortality in STEMI patients treated with primary PCI between January 2008 and December 2020 was performed. The prognostic value of WMSI, LVEF, and traditional risk scores (TIMI, GRACE) were compared using multivariable logistic regression modelling. Results. Among 1181 patients, 27 died within 30-days (2.3%) and 49 died within 12 months (4.2%). WMSI ≥1.8 was associated with poorer survival at 12-months (9.2% vs 1.5%; ). When used as the only classifier for predicting 12-month mortality, the discriminatory ability of WMSI (area under the curve (AUC): 0.77; 95% CI: 0.68–0.84) was significantly better than LVEF (AUC: 0.71; 95% CI: 0.61–0.79; ). After multivariable modelling, the AUC was comparable between models with either WMSI (AUC: 0.89; 95% CI: 0.85–0.94) or LVEF (AUC: 0.87; 95% CI: 0.83–0.92; ) yet performed significantly better than TIMI (AUC: 0.71; 95% CI: 0.62–0.79; ), or GRACE (AUC: 0.63; 95% CI: 0.54–0.71; ) risk scores. Conclusions. When examined individually, WMSI is a superior predictor of 12-month mortality over LVEF in STEMI patients treated with primary PCI. When examined in multivariable predictive models, WMSI and LVEF perform very well at predicting 12-month mortality, especially when compared to existing STEMI risk scores.
- 10 November 2022
- Published by Wiley in Critical Care Research and Practice
- Vol. 2022, 1-9
Open AccessThe Prognostic Value of Echocardiographic Wall Motion Score Index in ST-Segment Elevation Myocardial Infarction
Background. When compared to left ventricular ejection fraction (LVEF), previous studies have suggested the superiority of wall motion score index (WMSI) in predicting cardiac events in patients who have suffered acute myocardial infarction. However, there are limited studies assessing WMSI and mortality in ST-segment elevation myocardial infarction (STEMI). We aimed to compare the prognostic value of WMSI in a cohort of STEMI patients treated with primary percutaneous coronary intervention (PCI). Methods. A comparison of WMSI, LVEF, and all-cause mortality in STEMI patients treated with primary PCI between January 2008 and December 2020 was performed. The prognostic value of WMSI, LVEF, and traditional risk scores (TIMI, GRACE) were compared using multivariable logistic regression modelling. Results. Among 1181 patients, 27 died within 30-days (2.3%) and 49 died within 12 months (4.2%). WMSI ≥1.8 was associated with poorer survival at 12-months (9.2% vs 1.5%; ). When used as the only classifier for predicting 12-month mortality, the discriminatory ability of WMSI (area under the curve (AUC): 0.77; 95% CI: 0.68–0.84) was significantly better than LVEF (AUC: 0.71; 95% CI: 0.61–0.79; ). After multivariable modelling, the AUC was comparable between models with either WMSI (AUC: 0.89; 95% CI: 0.85–0.94) or LVEF (AUC: 0.87; 95% CI: 0.83–0.92; ) yet performed significantly better than TIMI (AUC: 0.71; 95% CI: 0.62–0.79; ), or GRACE (AUC: 0.63; 95% CI: 0.54–0.71; ) risk scores. Conclusions. When examined individually, WMSI is a superior predictor of 12-month mortality over LVEF in STEMI patients treated with primary PCI. When examined in multivariable predictive models, WMSI and LVEF perform very well at predicting 12-month mortality, especially when compared to existing STEMI risk scores.
- Open Access
- 24 April 2020
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 4 (3) , 1-6
Mitral valve bio-prosthesis and annuloplasty thrombosis during extracorporeal membrane oxygenation: case series
Background: Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is a well-recognized form of haemodynamic support for patients with refractory cardiogenic shock, who are unable to be weaned off cardiopulmonary bypass. Thrombosis or bleeding from cannula sites or surgical wounds are the leading cause of morbidity and mortality in these patients, and presents a delicate balance of anticoagulation during management of patients undergoing circulatory support. Case summary: In this case series, we discuss three cases of patients undergoing mitral valve replacements or repair with thrombosis of their new bio-prosthesis in the immediate post-operative setting. All three patients were supported with VA-ECMO post-operatively, and thrombosis occurred despite anticoagulation. Discussion: During extracorporeal membrane oxygenation, the reduced flow throughout the heart increases the risk of intra-cardiac thrombosis. This is of particular importance in the context of mitral valve replacements and repairs, where the bio-prosthesis is an additional risk factor for thrombosis. Our cases demonstrate the morbidity and mortality of such complications, with the likely aetiology being low transvalvular flow in a newly inserted valve combined with the pro-thrombotic state created by the VA-ECMO circuit.
- 24 April 2020
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 4 (3) , 1-6
Open AccessMitral valve bio-prosthesis and annuloplasty thrombosis during extracorporeal membrane oxygenation: case series
Background: Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is a well-recognized form of haemodynamic support for patients with refractory cardiogenic shock, who are unable to be weaned off cardiopulmonary bypass. Thrombosis or bleeding from cannula sites or surgical wounds are the leading cause of morbidity and mortality in these patients, and presents a delicate balance of anticoagulation during management of patients undergoing circulatory support. Case summary: In this case series, we discuss three cases of patients undergoing mitral valve replacements or repair with thrombosis of their new bio-prosthesis in the immediate post-operative setting. All three patients were supported with VA-ECMO post-operatively, and thrombosis occurred despite anticoagulation. Discussion: During extracorporeal membrane oxygenation, the reduced flow throughout the heart increases the risk of intra-cardiac thrombosis. This is of particular importance in the context of mitral valve replacements and repairs, where the bio-prosthesis is an additional risk factor for thrombosis. Our cases demonstrate the morbidity and mortality of such complications, with the likely aetiology being low transvalvular flow in a newly inserted valve combined with the pro-thrombotic state created by the VA-ECMO circuit.
- Open Access
- 1 June 2019
- Published by Springer Nature in Echo Research & Practice
- Vol. 6 (2) , 25-35
Echocardiographic assessment of myocardial function and mechanics during veno-venous extracorporeal membrane oxygenation
Background: Transthoracic echocardiography (TTE) plays a fundamental role in management of patients supported with extra-corporeal membrane oxygenation (ECMO). In light of fluctuating clinical states, serial monitoring of cardiac function is required. Formal quantification of ventricular parameters and myocardial mechanics offer benefit over qualitative assessment. The aim of this research was to compare unenhanced (UE) versus contrast-enhanced (CE) quantification of myocardial function and mechanics during ECMO in a validated ovine model. Methods: 24 sheep were commenced on peripheral veno-venous ECMO. Acute smoke induced lung injury was induced in 21 sheep (3 controls). CE-TTE with Definity using Cadence Pulse Sequencing was performed. 2 readers performed image analysis with TomTec Arena. End diastolic area (EDA-cm2), end systolic area (ESA-cm2), fractional area change (FAC-%), endocardial global circumferential strain (EGCS-%), myocardial global circumferential strain (MGCS-%), endocardial rotation (ER-degrees) and global radial strain (GRD-%) were evaluated for UE-TTE and CE-TTE. Results: Full data sets available in 22 sheep (92%). Mean CE EDA and ESA were significantly larger than in unenhanced images. Mean FAC was almost identical between the two techniques. No significant difference between UE and CE EGCS, MGCS and ER. There was significant difference in GRS between imaging techniques. Unenhanced inter-observer variability was from 0.48-0.70 but significantly improved to 0.71-0.89 for contrast imaging in all echocardiographic parameters. Conclusion: Semi-automated methods of myocardial function and mechanics using CE-TTE during ECMO was feasible and similar to UE-TTE for all parameters except ventricular areas and global radial strain. Addition of contrast significantly decreased inter-observer variability of all measurements.
- 1 June 2019
- Published by Springer Nature in Echo Research & Practice
- Vol. 6 (2) , 25-35
Open AccessEchocardiographic assessment of myocardial function and mechanics during veno-venous extracorporeal membrane oxygenation
Background: Transthoracic echocardiography (TTE) plays a fundamental role in management of patients supported with extra-corporeal membrane oxygenation (ECMO). In light of fluctuating clinical states, serial monitoring of cardiac function is required. Formal quantification of ventricular parameters and myocardial mechanics offer benefit over qualitative assessment. The aim of this research was to compare unenhanced (UE) versus contrast-enhanced (CE) quantification of myocardial function and mechanics during ECMO in a validated ovine model. Methods: 24 sheep were commenced on peripheral veno-venous ECMO. Acute smoke induced lung injury was induced in 21 sheep (3 controls). CE-TTE with Definity using Cadence Pulse Sequencing was performed. 2 readers performed image analysis with TomTec Arena. End diastolic area (EDA-cm2), end systolic area (ESA-cm2), fractional area change (FAC-%), endocardial global circumferential strain (EGCS-%), myocardial global circumferential strain (MGCS-%), endocardial rotation (ER-degrees) and global radial strain (GRD-%) were evaluated for UE-TTE and CE-TTE. Results: Full data sets available in 22 sheep (92%). Mean CE EDA and ESA were significantly larger than in unenhanced images. Mean FAC was almost identical between the two techniques. No significant difference between UE and CE EGCS, MGCS and ER. There was significant difference in GRS between imaging techniques. Unenhanced inter-observer variability was from 0.48-0.70 but significantly improved to 0.71-0.89 for contrast imaging in all echocardiographic parameters. Conclusion: Semi-automated methods of myocardial function and mechanics using CE-TTE during ECMO was feasible and similar to UE-TTE for all parameters except ventricular areas and global radial strain. Addition of contrast significantly decreased inter-observer variability of all measurements.
- Open Access
- 8 December 2017
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 19 (3) , 268
Three-dimensional printing: to guide management of a right coronary artery to left ventricular fistula
A 26-year-old female presented with 4 weeks of intermittent fever. Physical examination was notable for a diastolic murmur over the left sternal edge. Blood cultures were positive for Streptococcus anginosus. Transthoracic echocardiography demonstrated a mildly dilated left ventricle (LV) with normal function and a markedly dilated right coronary artery (RCA) fistula that enters the basal inferior LV (Panel A) with turbulent Doppler flow across the mitral valve (MV) leaflets. Transoesophageal echocardiography highlighted the severely dilated RCA (Panel C) and revealed a strand-like echodensity associated with the posterior MV leaflet tip, consistent with infective endocarditis (IE). Persistent turbulent flow may have cause scarring and eventual nidus for IE. The patient was treated with intravenous penicillin.
- 8 December 2017
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 19 (3) , 268
Open AccessThree-dimensional printing: to guide management of a right coronary artery to left ventricular fistula
A 26-year-old female presented with 4 weeks of intermittent fever. Physical examination was notable for a diastolic murmur over the left sternal edge. Blood cultures were positive for Streptococcus anginosus. Transthoracic echocardiography demonstrated a mildly dilated left ventricle (LV) with normal function and a markedly dilated right coronary artery (RCA) fistula that enters the basal inferior LV (Panel A) with turbulent Doppler flow across the mitral valve (MV) leaflets. Transoesophageal echocardiography highlighted the severely dilated RCA (Panel C) and revealed a strand-like echodensity associated with the posterior MV leaflet tip, consistent with infective endocarditis (IE). Persistent turbulent flow may have cause scarring and eventual nidus for IE. The patient was treated with intravenous penicillin.
- Open Access
- 1 December 2017
- Published by Elsevier in IJC Heart & Vasculature
- Vol. 17, 1-10
Contrast microsphere enhancement of the tricuspid regurgitant spectral Doppler signal - Is it still necessary with contemporary scanners?
- 1 December 2017
- Published by Elsevier in IJC Heart & Vasculature
- Vol. 17, 1-10
Open AccessContrast microsphere enhancement of the tricuspid regurgitant spectral Doppler signal - Is it still necessary with contemporary scanners?
- 1 October 2017
- Published by Elsevier in The American Journal of Cardiology
- Vol. 120 (8) , 1373-1380
Usefulness of Mitral Valve Prosthetic or Bioprosthetic Time Velocity Index Ratio to Detect Prosthetic or Bioprosthetic Mitral Valve Dysfunction
- 1 October 2017
- Published by Elsevier in The American Journal of Cardiology
- Vol. 120 (8) , 1373-1380
Usefulness of Mitral Valve Prosthetic or Bioprosthetic Time Velocity Index Ratio to Detect Prosthetic or Bioprosthetic Mitral Valve Dysfunction
- Open Access
- 23 June 2016
- Published by Elsevier in IJC Heart & Vasculature
- Vol. 12, 38-44
Accuracy of quantitative echocardiographic measures of right ventricular function as compared to cardiovascular magnetic resonance
- 23 June 2016
- Published by Elsevier in IJC Heart & Vasculature
- Vol. 12, 38-44
Open AccessAccuracy of quantitative echocardiographic measures of right ventricular function as compared to cardiovascular magnetic resonance
- Open Access
- 20 June 2016
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 18 (6) , 707-716
Intervendor consistency and reproducibility of left ventricular 2D global and regional strain with two different high-end ultrasound systems
We aimed to assess intervendor agreement of global (GLS) and regional longitudinal strain by vendor-specific software after EACVI/ASE Industry Task Force Standardization Initiatives for Deformation Imaging. Fifty-five patients underwent prospective dataset acquisitions on the same day by the same operator using two commercially available cardiac ultrasound systems (GE Vivid E9 and Philips iE33). GLS and regional peak longitudinal strain were analyzed offline using corresponding vendor-specific software (EchoPAC BT13 and QLAB version 10.3). Absolute mean GLS measurements were similar between the two vendors (GE −17.5 ± 5.2% vs. Philips −18.9 ± 5.1%, P = 0.15). There was excellent intervendor correlation of GLS by the same observer [r = 0.94, P < 0.0001; bias −1.3%, 95% CI limits of agreement (LOA) −4.8 to 2.2%). Intervendor comparison for regional longitudinal strain by coronary artery territories distribution were: LAD: r = 0.85, P < 0.0001; bias 0.5%, LOA −5.3 to 6.4%; RCA: r = 0.88, P < 0.0001; bias −2.4%, LOA −8.6 to 3.7%; LCX: r = 0.76, P < 0.0001; bias −5.3%, LOA −10.6 to 2.0%. Intervendor comparison for regional longitudinal strain by LV levels were: basal: r = 0.86, P < 0.0001; bias −3.6%, LOA −9.9 to 2.0%; mid: r = 0.90, P < 0.0001; bias −2.6%, LOA −7.8 to 2.6%; apical: r = 0.74; P < 0.0001; bias −1.3%, LOA −9.4 to 6.8%. Intervendor agreement in GLS and regional strain measurements have significantly improved after the EACVI/ASE Task Force Strain Standardization Initiatives. However, significant wide LOA still exist, especially for regional strain measurements, which remains relevant when considering vendor-specific software for serial measurements.
- 20 June 2016
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 18 (6) , 707-716
Open AccessIntervendor consistency and reproducibility of left ventricular 2D global and regional strain with two different high-end ultrasound systems
We aimed to assess intervendor agreement of global (GLS) and regional longitudinal strain by vendor-specific software after EACVI/ASE Industry Task Force Standardization Initiatives for Deformation Imaging. Fifty-five patients underwent prospective dataset acquisitions on the same day by the same operator using two commercially available cardiac ultrasound systems (GE Vivid E9 and Philips iE33). GLS and regional peak longitudinal strain were analyzed offline using corresponding vendor-specific software (EchoPAC BT13 and QLAB version 10.3). Absolute mean GLS measurements were similar between the two vendors (GE −17.5 ± 5.2% vs. Philips −18.9 ± 5.1%, P = 0.15). There was excellent intervendor correlation of GLS by the same observer [r = 0.94, P < 0.0001; bias −1.3%, 95% CI limits of agreement (LOA) −4.8 to 2.2%). Intervendor comparison for regional longitudinal strain by coronary artery territories distribution were: LAD: r = 0.85, P < 0.0001; bias 0.5%, LOA −5.3 to 6.4%; RCA: r = 0.88, P < 0.0001; bias −2.4%, LOA −8.6 to 3.7%; LCX: r = 0.76, P < 0.0001; bias −5.3%, LOA −10.6 to 2.0%. Intervendor comparison for regional longitudinal strain by LV levels were: basal: r = 0.86, P < 0.0001; bias −3.6%, LOA −9.9 to 2.0%; mid: r = 0.90, P < 0.0001; bias −2.6%, LOA −7.8 to 2.6%; apical: r = 0.74; P < 0.0001; bias −1.3%, LOA −9.4 to 6.8%. Intervendor agreement in GLS and regional strain measurements have significantly improved after the EACVI/ASE Task Force Strain Standardization Initiatives. However, significant wide LOA still exist, especially for regional strain measurements, which remains relevant when considering vendor-specific software for serial measurements.