Joo Young Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Joo Young Kim has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- In Young Kim
Hanyang University
6 shared publications - Baek Hwan Cho
Department of Biomedical Informatics, CHA University School of Medicine, CHA University, Seongnam, Republic of Korea
4 shared publications Baek Hwan Cho
3 shared publicationsBo Rum Nam
3 shared publicationsIn Young Kim
3 shared publications- Borum Nam
Hanyang Univ, Dept Elect Engn, Seoul, South Korea
2 shared publications
Latest Publications
- Open Access
- 30 September 2024
- Published by The Korean Institute of Broadcast and Media Engineers in Journal of Broadcast Engineering
- Vol. 29 (5) , 557-570
The Analysis of Work Patterns in K-pop Concert Production Collaboration to Derive UI/UX Elements for Designing a Collaboration Platform: Focused on Social Network Analysis
- 30 September 2024
- Published by The Korean Institute of Broadcast and Media Engineers in Journal of Broadcast Engineering
- Vol. 29 (5) , 557-570
Open AccessThe Analysis of Work Patterns in K-pop Concert Production Collaboration to Derive UI/UX Elements for Designing a Collaboration Platform: Focused on Social Network Analysis
- Open Access
- 15 March 2022
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 10 (3) , e30587
Selective Prediction With Long Short-term Memory Using Unit-Wise Batch Standardization for Time Series Health Data Sets: Algorithm Development and Validation
Background: In any health care system, both the classification of data and the confidence level of such classifications are important. Therefore, a selective prediction model is required to classify time series health data according to confidence levels of prediction.Objective: This study aims to develop a method using long short-term memory (LSTM) models with a reject option for time series health data classification.Methods: An existing selective prediction method was adopted to implement an option for rejecting a classification output in LSTM models. However, a conventional selection function approach to LSTM does not achieve acceptable performance during learning stages. To tackle this problem, we proposed a unit-wise batch standardization that attempts to normalize each hidden unit in LSTM to apply the structural characteristics of LSTM models that concern the selection function.Results: The ability of our method to approximate the target confidence level was compared by coverage violations for 2 time series of health data sets consisting of human activity and arrhythmia. For both data sets, our approach yielded lower average coverage violations (0.98% and 1.79% for each data set) than those of the conventional approach. In addition, the classification performance when using the reject option was compared with that of other normalization methods. Our method demonstrated superior performance for selective risk (12.63% and 17.82% for each data set), false-positive rates (2.09% and 5.8% for each data set), and false-negative rates (10.58% and 17.24% for each data set).Conclusions: Our normalization approach can help make selective predictions for time series health data. We expect this technique to enhance the confidence of users in classification systems and improve collaborative efforts between humans and artificial intelligence in the medical field through the use of classification that considers confidence.
- 15 March 2022
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 10 (3) , e30587
Open AccessSelective Prediction With Long Short-term Memory Using Unit-Wise Batch Standardization for Time Series Health Data Sets: Algorithm Development and Validation
Background: In any health care system, both the classification of data and the confidence level of such classifications are important. Therefore, a selective prediction model is required to classify time series health data according to confidence levels of prediction.Objective: This study aims to develop a method using long short-term memory (LSTM) models with a reject option for time series health data classification.Methods: An existing selective prediction method was adopted to implement an option for rejecting a classification output in LSTM models. However, a conventional selection function approach to LSTM does not achieve acceptable performance during learning stages. To tackle this problem, we proposed a unit-wise batch standardization that attempts to normalize each hidden unit in LSTM to apply the structural characteristics of LSTM models that concern the selection function.Results: The ability of our method to approximate the target confidence level was compared by coverage violations for 2 time series of health data sets consisting of human activity and arrhythmia. For both data sets, our approach yielded lower average coverage violations (0.98% and 1.79% for each data set) than those of the conventional approach. In addition, the classification performance when using the reject option was compared with that of other normalization methods. Our method demonstrated superior performance for selective risk (12.63% and 17.82% for each data set), false-positive rates (2.09% and 5.8% for each data set), and false-negative rates (10.58% and 17.24% for each data set).Conclusions: Our normalization approach can help make selective predictions for time series health data. We expect this technique to enhance the confidence of users in classification systems and improve collaborative efforts between humans and artificial intelligence in the medical field through the use of classification that considers confidence.
- 30 September 2021
- Published by The Korean Academy of Scientific Criminal Investigation in The Korean Academy of Scientific Criminal Investigation
- Vol. 15 (3) , 238-243
Development of Non-contact Deception Detection using Facial Expression and Analysis of Significant Time Period
- 30 September 2021
- Published by The Korean Academy of Scientific Criminal Investigation in The Korean Academy of Scientific Criminal Investigation
- Vol. 15 (3) , 238-243
Development of Non-contact Deception Detection using Facial Expression and Analysis of Significant Time Period
- Open Access
- 23 July 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-12
Deep-learning framework and computer assisted fatty infiltration analysis for the supraspinatus muscle in MRI
Occupation ratio and fatty infiltration are important parameters for evaluating patients with rotator cuff tears. We analyzed the occupation ratio using a deep-learning framework and studied the fatty infiltration of the supraspinatus muscle using an automated region-based Otsu thresholding technique. To calculate the amount of fatty infiltration of the supraspinatus muscle using an automated region-based Otsu thresholding technique. The mean Dice similarity coefficient, accuracy, sensitivity, specificity, and relative area difference for the segmented lesion, measuring the similarity of clinician assessment and that of a deep neural network, were 0.97, 99.84, 96.89, 99.92, and 0.07, respectively, for the supraspinatus fossa and 0.94, 99.89, 93.34, 99.95, and 2.03, respectively, for the supraspinatus muscle. The fatty infiltration measure using the Otsu thresholding method significantly differed among the Goutallier grades (Grade 0; 0.06, Grade 1; 4.68, Grade 2; 20.10, Grade 3; 42.86, Grade 4; 55.79, p < 0.0001). The occupation ratio and fatty infiltration using Otsu thresholding demonstrated a moderate negative correlation (ρ = − 0.75, p < 0.0001). This study included 240 randomly selected patients who underwent shoulder magnetic resonance imaging (MRI) from January 2015 to December 2016. We used a fully convolutional deep-learning algorithm to quantitatively detect the fossa and muscle regions by measuring the occupation ratio of the supraspinatus muscle. Fatty infiltration was objectively evaluated using the Otsu thresholding method. The proposed convolutional neural network exhibited fast and accurate segmentation of the supraspinatus muscle and fossa from shoulder MRI, allowing automatic calculation of the occupation ratio. Quantitative evaluation using a modified Otsu thresholding method can be used to calculate the proportion of fatty infiltration in the supraspinatus muscle. We expect that this will improve the efficiency and objectivity of diagnoses by quantifying the index used for shoulder MRI.
- 23 July 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-12
Open AccessDeep-learning framework and computer assisted fatty infiltration analysis for the supraspinatus muscle in MRI
Occupation ratio and fatty infiltration are important parameters for evaluating patients with rotator cuff tears. We analyzed the occupation ratio using a deep-learning framework and studied the fatty infiltration of the supraspinatus muscle using an automated region-based Otsu thresholding technique. To calculate the amount of fatty infiltration of the supraspinatus muscle using an automated region-based Otsu thresholding technique. The mean Dice similarity coefficient, accuracy, sensitivity, specificity, and relative area difference for the segmented lesion, measuring the similarity of clinician assessment and that of a deep neural network, were 0.97, 99.84, 96.89, 99.92, and 0.07, respectively, for the supraspinatus fossa and 0.94, 99.89, 93.34, 99.95, and 2.03, respectively, for the supraspinatus muscle. The fatty infiltration measure using the Otsu thresholding method significantly differed among the Goutallier grades (Grade 0; 0.06, Grade 1; 4.68, Grade 2; 20.10, Grade 3; 42.86, Grade 4; 55.79, p < 0.0001). The occupation ratio and fatty infiltration using Otsu thresholding demonstrated a moderate negative correlation (ρ = − 0.75, p < 0.0001). This study included 240 randomly selected patients who underwent shoulder magnetic resonance imaging (MRI) from January 2015 to December 2016. We used a fully convolutional deep-learning algorithm to quantitatively detect the fossa and muscle regions by measuring the occupation ratio of the supraspinatus muscle. Fatty infiltration was objectively evaluated using the Otsu thresholding method. The proposed convolutional neural network exhibited fast and accurate segmentation of the supraspinatus muscle and fossa from shoulder MRI, allowing automatic calculation of the occupation ratio. Quantitative evaluation using a modified Otsu thresholding method can be used to calculate the proportion of fatty infiltration in the supraspinatus muscle. We expect that this will improve the efficiency and objectivity of diagnoses by quantifying the index used for shoulder MRI.
- Open Access
- 21 May 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Selective Prediction With Long Short-term Memory Using Unit-Wise Batch Standardization for Time Series Health Data Sets: Algorithm Development and Validation (Preprint)
BACKGROUND In any health care system, both the classification of data and the confidence level of such classifications are important. Therefore, a selective prediction model is required to classify time series health data according to confidence levels of prediction. OBJECTIVE This study aims to develop a method using long short-term memory (LSTM) models with a reject option for time series health data classification. METHODS An existing selective prediction method was adopted to implement an option for rejecting a classification output in LSTM models. However, a conventional selection function approach to LSTM does not achieve acceptable performance during learning stages. To tackle this problem, we proposed a unit-wise batch standardization that attempts to normalize each hidden unit in LSTM to apply the structural characteristics of LSTM models that concern the selection function. RESULTS The ability of our method to approximate the target confidence level was compared by coverage violations for 2 time series of health data sets consisting of human activity and arrhythmia. For both data sets, our approach yielded lower average coverage violations (0.98% and 1.79% for each data set) than those of the conventional approach. In addition, the classification performance when using the reject option was compared with that of other normalization methods. Our method demonstrated superior performance for selective risk (12.63% and 17.82% for each data set), false-positive rates (2.09% and 5.8% for each data set), and false-negative rates (10.58% and 17.24% for each data set). CONCLUSIONS Our normalization approach can help make selective predictions for time series health data. We expect this technique to enhance the confidence of users in classification systems and improve collaborative efforts between humans and artificial intelligence in the medical field through the use of classification that considers confidence. CLINICALTRIAL
- 21 May 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessSelective Prediction With Long Short-term Memory Using Unit-Wise Batch Standardization for Time Series Health Data Sets: Algorithm Development and Validation (Preprint)
BACKGROUND In any health care system, both the classification of data and the confidence level of such classifications are important. Therefore, a selective prediction model is required to classify time series health data according to confidence levels of prediction. OBJECTIVE This study aims to develop a method using long short-term memory (LSTM) models with a reject option for time series health data classification. METHODS An existing selective prediction method was adopted to implement an option for rejecting a classification output in LSTM models. However, a conventional selection function approach to LSTM does not achieve acceptable performance during learning stages. To tackle this problem, we proposed a unit-wise batch standardization that attempts to normalize each hidden unit in LSTM to apply the structural characteristics of LSTM models that concern the selection function. RESULTS The ability of our method to approximate the target confidence level was compared by coverage violations for 2 time series of health data sets consisting of human activity and arrhythmia. For both data sets, our approach yielded lower average coverage violations (0.98% and 1.79% for each data set) than those of the conventional approach. In addition, the classification performance when using the reject option was compared with that of other normalization methods. Our method demonstrated superior performance for selective risk (12.63% and 17.82% for each data set), false-positive rates (2.09% and 5.8% for each data set), and false-negative rates (10.58% and 17.24% for each data set). CONCLUSIONS Our normalization approach can help make selective predictions for time series health data. We expect this technique to enhance the confidence of users in classification systems and improve collaborative efforts between humans and artificial intelligence in the medical field through the use of classification that considers confidence. CLINICALTRIAL
- 1 December 2019
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 182, 105063
Development of an automatic muscle atrophy measuring algorithm to calculate the ratio of supraspinatus in supraspinous fossa using deep learning
- 1 December 2019
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 182, 105063
Development of an automatic muscle atrophy measuring algorithm to calculate the ratio of supraspinatus in supraspinous fossa using deep learning
- Open Access
New Method for Pure-Tone Audiometry Using Electrooculogram: A Proof-of-Concept Study
Precise and timely evaluation of an individual’s hearing loss plays an important role in determining appropriate treatment strategies, including medication and aural rehabilitation. However, currently available hearing assessment systems do not satisfy the need for an objective assessment tool with a simple and non-invasive procedure. In this paper, we propose a new method for pure-tone audiometry, which may potentially be used to assess an individual’s hearing ability objectively and quantitatively, without need for the user’s active response. The proposed method is based on the auditory oculogyric reflex, where the eyes involuntary rotate towards the source of a sound, in response to spatially moving pure-tone audio stimuli modulated at specific frequencies and intensities. We quantitatively analyzed horizontal electrooculograms (EOG) recorded with a pair of electrodes under two conditions—when pure-tone stimuli were (1) “inaudible” or (2) “audible” to a participant. Preliminary experimental results showed significantly increased EOG amplitude in the audible condition compared to the inaudible condition for all ten healthy participants. This demonstrates potential use of the proposed method as a new non-invasive hearing assessment tool.
Open AccessNew Method for Pure-Tone Audiometry Using Electrooculogram: A Proof-of-Concept Study
Precise and timely evaluation of an individual’s hearing loss plays an important role in determining appropriate treatment strategies, including medication and aural rehabilitation. However, currently available hearing assessment systems do not satisfy the need for an objective assessment tool with a simple and non-invasive procedure. In this paper, we propose a new method for pure-tone audiometry, which may potentially be used to assess an individual’s hearing ability objectively and quantitatively, without need for the user’s active response. The proposed method is based on the auditory oculogyric reflex, where the eyes involuntary rotate towards the source of a sound, in response to spatially moving pure-tone audio stimuli modulated at specific frequencies and intensities. We quantitatively analyzed horizontal electrooculograms (EOG) recorded with a pair of electrodes under two conditions—when pure-tone stimuli were (1) “inaudible” or (2) “audible” to a participant. Preliminary experimental results showed significantly increased EOG amplitude in the audible condition compared to the inaudible condition for all ten healthy participants. This demonstrates potential use of the proposed method as a new non-invasive hearing assessment tool.
- 1 August 2018
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 45, 91-97
Scalp tapping-based protocol for adjusting the parameters of binaural hearing aids
- 1 August 2018
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 45, 91-97
Scalp tapping-based protocol for adjusting the parameters of binaural hearing aids