Hu Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hu Wu has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Jürgen Müller
Institute of Geodesy, Leibniz University Hannover, Hannover, Germany
8 shared publications - Franck Pereira Dos Santos
Observatoire de Paris
3 shared publications - Alireza HosseiniArani
Leibniz University Hannover Institut für Erdmessung (IfE) Hannover Germany
2 shared publications - Annike Knabe
Institute of Geodesy, Leibniz University Hannover, Hannover, Germany
2 shared publications Christian Schubert
Institut fur Quantenoptik, Leibniz Universitaet Hannover, Welfengarten 1, 30167 Hannover, Hannover, GERMANY
2 shared publicationsJürgen Müller
Institut für Erdmessung (IfE), Leibniz Universität Hannover, Hannover, Germany
2 shared publications
Latest Publications
- Open Access
- 15 September 2023
- Published by Springer Nature
- p. 53-62
Estimation of Temporal Variations in the Earth’s Gravity Field Using Novel Optical Clocks Onboard of Low Earth Orbiters
The current generation of optical atomic clocks has reached a fractional frequency uncertainty of 1 $$\times $$ 10 $$^{-18}$$ (and beyond) which corresponds to a geopotential difference of 0.1 m $$^{2}$$ /s $$^{2}$$ . Those gravitational potential differences can be observed as gravitational redshift when comparing the frequencies of optical clocks. Even temporal potential variations might be determined with precise novel optical atomic clocks onboard of low-orbiting satellites such as SLR-like (e.g. LAGEOS-1/2) and GRACE-like missions.In this simulation study, the potential of precise space-borne optical clocks for the determination of temporal variations of low-degree Earth’s gravity field coefficients are investigated. Different configurations of satellite orbits, i.e. at different altitudes (between 400 and 6000 km) and inclinations, are selected as well as certain assumptions on the clock performance are made. A particular focus is put on how well degree-2 coefficients can be estimated from those optical clock measurements and how it compares to results from SLR.- 15 September 2023
- Published by Springer Nature
- p. 53-62
Open AccessEstimation of Temporal Variations in the Earth’s Gravity Field Using Novel Optical Clocks Onboard of Low Earth Orbiters
The current generation of optical atomic clocks has reached a fractional frequency uncertainty of 1 $$\times $$ 10 $$^{-18}$$ (and beyond) which corresponds to a geopotential difference of 0.1 m $$^{2}$$ /s $$^{2}$$ . Those gravitational potential differences can be observed as gravitational redshift when comparing the frequencies of optical clocks. Even temporal potential variations might be determined with precise novel optical atomic clocks onboard of low-orbiting satellites such as SLR-like (e.g. LAGEOS-1/2) and GRACE-like missions.In this simulation study, the potential of precise space-borne optical clocks for the determination of temporal variations of low-degree Earth’s gravity field coefficients are investigated. Different configurations of satellite orbits, i.e. at different altitudes (between 400 and 6000 km) and inclinations, are selected as well as certain assumptions on the clock performance are made. A particular focus is put on how well degree-2 coefficients can be estimated from those optical clock measurements and how it compares to results from SLR. - Open Access
- 22 October 2022
- Published by Springer Nature
- p. 221-231
Kalman-Filter Based Hybridization of Classic and Cold Atom Interferometry Accelerometers for Future Satellite Gravity Missions
Proof-of-principle demonstrations have been made for cold atom interferometer (CAI) sensors. Using CAI-based accelerometers in the next generation of satellite gravimetry missions can provide long-term stability and precise measurements of the non-gravitational forces acting on the satellites. This would allow a better understanding of climate change processes and geophysical phenomena which require long-term monitoring of mass variations with sufficient spatial and temporal resolution. The proposed accuracy and long-term stability of CAI-based accelerometers appear promising, while there are some major drawbacks in the long dead times and the comparatively small dynamic range of the sensors. One interesting way to handle these limitations is to use a hybridization with a conventional navigation sensor. This study discusses one possible solution to employ measurements of a CAI accelerometer together with a conventional Inertial Measurement Unit (IMU) using a Kalman filter framework. A hybrid navigation solution of these two sensors for applications on ground has already been demonstrated in simulations. Here, we adapt this method to a space-based GRACE-like gravimetry mission. A simulation is performed, where the sensitivity of the CAI accelerometer is estimated based on state-of-the-art ground sensors and further published space scenarios. Our results show that the Kalman filter framework can be used to combine the measurements of conventional inertial measurement units with the CAI accelerometers measurements in a way to benefit from the high accuracy of the conventional IMU measurements in higher frequencies together with the high stability of CAI measurements in lower frequencies. We will discuss the challenges, potential solutions, and the possible performance limits of the proposed hybrid accelerometry scenario.
- 22 October 2022
- Published by Springer Nature
- p. 221-231
Open AccessKalman-Filter Based Hybridization of Classic and Cold Atom Interferometry Accelerometers for Future Satellite Gravity Missions
Proof-of-principle demonstrations have been made for cold atom interferometer (CAI) sensors. Using CAI-based accelerometers in the next generation of satellite gravimetry missions can provide long-term stability and precise measurements of the non-gravitational forces acting on the satellites. This would allow a better understanding of climate change processes and geophysical phenomena which require long-term monitoring of mass variations with sufficient spatial and temporal resolution. The proposed accuracy and long-term stability of CAI-based accelerometers appear promising, while there are some major drawbacks in the long dead times and the comparatively small dynamic range of the sensors. One interesting way to handle these limitations is to use a hybridization with a conventional navigation sensor. This study discusses one possible solution to employ measurements of a CAI accelerometer together with a conventional Inertial Measurement Unit (IMU) using a Kalman filter framework. A hybrid navigation solution of these two sensors for applications on ground has already been demonstrated in simulations. Here, we adapt this method to a space-based GRACE-like gravimetry mission. A simulation is performed, where the sensitivity of the CAI accelerometer is estimated based on state-of-the-art ground sensors and further published space scenarios. Our results show that the Kalman filter framework can be used to combine the measurements of conventional inertial measurement units with the CAI accelerometers measurements in a way to benefit from the high accuracy of the conventional IMU measurements in higher frequencies together with the high stability of CAI measurements in lower frequencies. We will discuss the challenges, potential solutions, and the possible performance limits of the proposed hybrid accelerometry scenario.
- Open Access
- 17 August 2022
- Published by Springer Nature
- p. 213-220
The Benefit of Accelerometers Based on Cold Atom Interferometry for Future Satellite Gravity Missions
Satellite gravity missions, like GRACE and GRACE Follow-On, successfully map the Earth’s gravity field and its change over time. With the addition of the laser ranging interferometer (LRI) to GRACE-FO, a significant improvement over GRACE for inter-satellite ranging was achieved. One of the limiting factors is the accelerometer for measuring the non-gravitational forces acting on the satellite. The classical electrostatic accelerometers are affected by a drift at low frequencies. This drawback can be counterbalanced by adding an accelerometer based on cold atom interferometry (CAI) due to its high long-term stability. The CAI concept has already been successfully demonstrated in ground experiments and is expected to show an even higher sensitivity in space. In order to investigate the potential of the CAI concept for future satellite gravity missions, a closed-loop simulation is performed in the context of GRACE-FO like missions. The sensitivity of the CAI accelerometer is estimated based on state-of-the-art ground sensors and predictions for space applications. The sensor performance is tested for different scenarios and the benefits to the gravity field solutions are quantitatively evaluated. It is shown that a classical accelerometer aided by CAI technology improves the results of the gravity field recovery especially in reducing the striping effects. The non-gravitational accelerations are modelled using a detailed surface model of a GRACE-like satellite body. This is required for a realistic determination of the variations of the non-gravitational accelerations during one interferometer cycle. It is demonstrated that the estimated error due to this variation is significant. We consider different orbit altitudes and also analyze the effect of drag compensation.
- 17 August 2022
- Published by Springer Nature
- p. 213-220
Open AccessThe Benefit of Accelerometers Based on Cold Atom Interferometry for Future Satellite Gravity Missions
Satellite gravity missions, like GRACE and GRACE Follow-On, successfully map the Earth’s gravity field and its change over time. With the addition of the laser ranging interferometer (LRI) to GRACE-FO, a significant improvement over GRACE for inter-satellite ranging was achieved. One of the limiting factors is the accelerometer for measuring the non-gravitational forces acting on the satellite. The classical electrostatic accelerometers are affected by a drift at low frequencies. This drawback can be counterbalanced by adding an accelerometer based on cold atom interferometry (CAI) due to its high long-term stability. The CAI concept has already been successfully demonstrated in ground experiments and is expected to show an even higher sensitivity in space. In order to investigate the potential of the CAI concept for future satellite gravity missions, a closed-loop simulation is performed in the context of GRACE-FO like missions. The sensitivity of the CAI accelerometer is estimated based on state-of-the-art ground sensors and predictions for space applications. The sensor performance is tested for different scenarios and the benefits to the gravity field solutions are quantitatively evaluated. It is shown that a classical accelerometer aided by CAI technology improves the results of the gravity field recovery especially in reducing the striping effects. The non-gravitational accelerations are modelled using a detailed surface model of a GRACE-like satellite body. This is required for a realistic determination of the variations of the non-gravitational accelerations during one interferometer cycle. It is demonstrated that the estimated error due to this variation is significant. We consider different orbit altitudes and also analyze the effect of drag compensation.
- Open Access
- 4 March 2021
- Published by Copernicus GmbH
Clock networks and their sensibility to time-variable gravity signals
High-performance clock networks are considered as a novel tool in geodesy. Today the latest generation of optical clocks approaches a fractional frequency uncertainty of 1.0x10-18, which corresponds to about 1.0 cm in height or 0.1 m2/s2 in geopotential. The connected clocks are thus promising to enable “relativistic geodesy” in practice: Gravity potential (or height) differences can be inferred through the ultra-precise comparison of clocks’ frequencies.In this study, we will investigate the possibility of high-performance clock networks for detecting time-variable gravity signals. In the past two decades, the satellite gravity mission GRACE, now continued by its follow-on mission, has significantly improved our knowledge on the Earth’s gravity field, especially on its changes over time. However, the results are limited in terms of spatial resolution (about a few hundreds of kilometers) and temporal resolution (standard is one month). Terrestrial clock networks can be used to observe point-wise gravity potential values at locations of interest. By continuously tracking of changes w.r.t. a reference clock, time-series of gravity potential values are obtained, which reveal the gravity variations at these locations. To elaborate this idea, we will address the following research questions:Are clock measurements with the accuracy of 10-18 sensitive enough to time-variable gravity signals? Or what is the requirement on the clock’s performance for detecting time-variable gravity signals? Which kinds of time-variable signals can be “seen” by clocks, the long-term trends (yearly), seasonal variations or short-term changes (weekly/daily)? In which regions might clock networks be sensitive to time-variable gravity signals, in Amazon, Greenland or also in Europe? An “absolute” reference clock is required for a network that should be least affected by gravity variations. Where should it be placed? We gratefully acknowledge the financial support by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) under Germany’s Excellence Strategy EXC-2123 “QuantumFrontiers” (Project-ID: 390837967). This work is also funded by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) – Project-ID 434617780 – SFB 1464.
- 4 March 2021
- Published by Copernicus GmbH
Open AccessClock networks and their sensibility to time-variable gravity signals
High-performance clock networks are considered as a novel tool in geodesy. Today the latest generation of optical clocks approaches a fractional frequency uncertainty of 1.0x10-18, which corresponds to about 1.0 cm in height or 0.1 m2/s2 in geopotential. The connected clocks are thus promising to enable “relativistic geodesy” in practice: Gravity potential (or height) differences can be inferred through the ultra-precise comparison of clocks’ frequencies.In this study, we will investigate the possibility of high-performance clock networks for detecting time-variable gravity signals. In the past two decades, the satellite gravity mission GRACE, now continued by its follow-on mission, has significantly improved our knowledge on the Earth’s gravity field, especially on its changes over time. However, the results are limited in terms of spatial resolution (about a few hundreds of kilometers) and temporal resolution (standard is one month). Terrestrial clock networks can be used to observe point-wise gravity potential values at locations of interest. By continuously tracking of changes w.r.t. a reference clock, time-series of gravity potential values are obtained, which reveal the gravity variations at these locations. To elaborate this idea, we will address the following research questions:Are clock measurements with the accuracy of 10-18 sensitive enough to time-variable gravity signals? Or what is the requirement on the clock’s performance for detecting time-variable gravity signals? Which kinds of time-variable signals can be “seen” by clocks, the long-term trends (yearly), seasonal variations or short-term changes (weekly/daily)? In which regions might clock networks be sensitive to time-variable gravity signals, in Amazon, Greenland or also in Europe? An “absolute” reference clock is required for a network that should be least affected by gravity variations. Where should it be placed? We gratefully acknowledge the financial support by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) under Germany’s Excellence Strategy EXC-2123 “QuantumFrontiers” (Project-ID: 390837967). This work is also funded by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) – Project-ID 434617780 – SFB 1464.
- Open Access
- 24 July 2020
- Published by Springer Nature in Journal of Geodesy
- Vol. 94 (8) , 1-14
Using quantum optical sensors for determining the Earth’s gravity field from space
Quantum optical technology provides an opportunity to develop new kinds of gravity sensors and to enable novel measurement concepts for gravimetry. Two candidates are considered in this study: the cold atom interferometry (CAI) gradiometer and optical clocks. Both sensors show a high sensitivity and long-term stability. They are assumed on board of a low-orbit satellite like gravity field and steady-state ocean circulation explorer (GOCE) and gravity recovery and climate experiment (GRACE) to determine the Earth’s gravity field. Their individual contributions were assessed through closed-loop simulations which rigorously mapped the sensors’ sensitivities to the gravity field coefficients. Clocks, which can directly obtain the gravity potential (differences) through frequency comparison, show a high sensitivity to the very long-wavelength gravity field. In the GRACE orbit, clocks with an uncertainty level of $$1.0\times 10^{-18}$$ are capable to retrieve temporal gravity signals below degree 12, while $$1.0\times 10^{-17}$$ clocks are useful for detecting the signals of degree 2 only. However, it poses challenges for clocks to achieve such uncertainties in a short time. In space, the CAI gradiometer is expected to have its ultimate sensitivity and a remarkable stability over a long time (measurements are precise down to very low frequencies). The three diagonal gravity gradients can properly be measured by CAI gradiometry with a same noise level of 5.0 $${\mathrm{mE}/\sqrt{\mathrm{Hz}}}$$ . They can potentially lead to a 2–5 times better solution of the static gravity field than that of GOCE above degree and order 50, where the GOCE solution is mainly dominated by the gradient measurements. In the lower degree part, benefits from CAI gradiometry are still visible, but there, solutions from GRACE-like missions are superior.- 24 July 2020
- Published by Springer Nature in Journal of Geodesy
- Vol. 94 (8) , 1-14
Open AccessUsing quantum optical sensors for determining the Earth’s gravity field from space
Quantum optical technology provides an opportunity to develop new kinds of gravity sensors and to enable novel measurement concepts for gravimetry. Two candidates are considered in this study: the cold atom interferometry (CAI) gradiometer and optical clocks. Both sensors show a high sensitivity and long-term stability. They are assumed on board of a low-orbit satellite like gravity field and steady-state ocean circulation explorer (GOCE) and gravity recovery and climate experiment (GRACE) to determine the Earth’s gravity field. Their individual contributions were assessed through closed-loop simulations which rigorously mapped the sensors’ sensitivities to the gravity field coefficients. Clocks, which can directly obtain the gravity potential (differences) through frequency comparison, show a high sensitivity to the very long-wavelength gravity field. In the GRACE orbit, clocks with an uncertainty level of $$1.0\times 10^{-18}$$ are capable to retrieve temporal gravity signals below degree 12, while $$1.0\times 10^{-17}$$ clocks are useful for detecting the signals of degree 2 only. However, it poses challenges for clocks to achieve such uncertainties in a short time. In space, the CAI gradiometer is expected to have its ultimate sensitivity and a remarkable stability over a long time (measurements are precise down to very low frequencies). The three diagonal gravity gradients can properly be measured by CAI gradiometry with a same noise level of 5.0 $${\mathrm{mE}/\sqrt{\mathrm{Hz}}}$$ . They can potentially lead to a 2–5 times better solution of the static gravity field than that of GOCE above degree and order 50, where the GOCE solution is mainly dominated by the gradient measurements. In the lower degree part, benefits from CAI gradiometry are still visible, but there, solutions from GRACE-like missions are superior. - Open Access
- 23 April 2020
- Published by Springer Nature
- p. 3-10
Towards an International Height Reference Frame Using Clock Networks
Establishing an International Height Reference Frame (IHRF) has been a major goal of the International Association of Geodesy (IAG) for a long time. One challenge is to obtain the vertical coordinates, i.e., geopotential numbers, of the reference stations with high precision and global consistency. A promising approach is using clock networks, which are powerful in precisely obtaining geopotential or height differences between distant sites through measuring the gravitational redshift effect by comparing clocks’ frequencies. We propose a hybrid clock network following a specific hierarchy. It includes stationary clocks as the backbone of the frame and transportable clocks for regional densifications. The vertical coordinates of the clock stations can be straightforwardly referenced to the unique benchmark by various long-distance frequency transfer techniques, like using optical fibers or free-space microwave and laser links via relay satellites. Another practical way towards an IHRF is to unify all local height systems around the world. Clock networks are considered as an alternative to classical geodetic methods. The idea was verified through closed-loop simulations. We found that the measurements acquired by a few 10−18 clocks, three or four in triangular or quadrangular distributions for each local system, are sufficient to adjust the discrepancies between local datums and the systematic slopes within local height networks.
- 23 April 2020
- Published by Springer Nature
- p. 3-10
Open AccessTowards an International Height Reference Frame Using Clock Networks
Establishing an International Height Reference Frame (IHRF) has been a major goal of the International Association of Geodesy (IAG) for a long time. One challenge is to obtain the vertical coordinates, i.e., geopotential numbers, of the reference stations with high precision and global consistency. A promising approach is using clock networks, which are powerful in precisely obtaining geopotential or height differences between distant sites through measuring the gravitational redshift effect by comparing clocks’ frequencies. We propose a hybrid clock network following a specific hierarchy. It includes stationary clocks as the backbone of the frame and transportable clocks for regional densifications. The vertical coordinates of the clock stations can be straightforwardly referenced to the unique benchmark by various long-distance frequency transfer techniques, like using optical fibers or free-space microwave and laser links via relay satellites. Another practical way towards an IHRF is to unify all local height systems around the world. Clock networks are considered as an alternative to classical geodetic methods. The idea was verified through closed-loop simulations. We found that the measurements acquired by a few 10−18 clocks, three or four in triangular or quadrangular distributions for each local system, are sufficient to adjust the discrepancies between local datums and the systematic slopes within local height networks.
- Open Access
- 9 March 2020
- Published by Copernicus GmbH
Optical clocks for gravity field observation and further geodetic applications
In the past three decades, optical clocks and frequency transfer techniques have experienced a rapid development. They are approaching a fractional frequency uncertainty of 1.0x10-18, corresponding to about 1.0 cm in height. This makes them promising to realize “relativistic geodesy”, and it opens a new door to directly obtain gravity potential values by the comparison of clock frequencies. Clocks are thus considered as a novel candidate for determining the Earth’s gravity field. We propose to use a spaceborne clock to obtain gravity potential values along a satellite orbit through its comparison with reference clocks on ground or with a co-orbital clock. The sensitivity of clock measurements is mapped to gravity field coefficients through closed-loop simulations. In addition, clocks are investigated for other geodetic applications. Since they are powerful in providing the height difference between distant sites, clocks can be applied for the unification of local/regional height systems, by estimating the offsets between different height datums and the systematic errors within levelling networks. In some regions like Greenland, clocks might be a complementary tool to GRACE(-FO) for detecting temporal gravity signals. They can be operated at locations of interest and continuously track changes w.r.t. reference clock stations. The resulting time-series of gravity potential values reveal the temporal gravity signals at these points. Moreover, as the equipotential surface at a high satellite altitude is more regular than that on the Earth’s surface, a couple of clocks in geostationary orbits can realize a space-based reference for the determination of physical heights at any point on the Earth through clock comparisons. We gratefully acknowledge the financial support by the Deutsche Forschungsgemeinschaft (DFG) under Germany’s Excellence Strategy EXC-2123/1 (Project-ID: 390837967).
- 9 March 2020
- Published by Copernicus GmbH
Open AccessOptical clocks for gravity field observation and further geodetic applications
In the past three decades, optical clocks and frequency transfer techniques have experienced a rapid development. They are approaching a fractional frequency uncertainty of 1.0x10-18, corresponding to about 1.0 cm in height. This makes them promising to realize “relativistic geodesy”, and it opens a new door to directly obtain gravity potential values by the comparison of clock frequencies. Clocks are thus considered as a novel candidate for determining the Earth’s gravity field. We propose to use a spaceborne clock to obtain gravity potential values along a satellite orbit through its comparison with reference clocks on ground or with a co-orbital clock. The sensitivity of clock measurements is mapped to gravity field coefficients through closed-loop simulations. In addition, clocks are investigated for other geodetic applications. Since they are powerful in providing the height difference between distant sites, clocks can be applied for the unification of local/regional height systems, by estimating the offsets between different height datums and the systematic errors within levelling networks. In some regions like Greenland, clocks might be a complementary tool to GRACE(-FO) for detecting temporal gravity signals. They can be operated at locations of interest and continuously track changes w.r.t. reference clock stations. The resulting time-series of gravity potential values reveal the temporal gravity signals at these points. Moreover, as the equipotential surface at a high satellite altitude is more regular than that on the Earth’s surface, a couple of clocks in geostationary orbits can realize a space-based reference for the determination of physical heights at any point on the Earth through clock comparisons. We gratefully acknowledge the financial support by the Deutsche Forschungsgemeinschaft (DFG) under Germany’s Excellence Strategy EXC-2123/1 (Project-ID: 390837967).
- Top Cited Papers
- 10 October 2019
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 36 (21) , 215004
Concept study and preliminary design of a cold atom interferometer for space gravity gradiometry
We study a space-based gravity gradiometer based on cold atom interferometry and its potential for the Earth’s gravitational field mapping. The instrument architecture has been proposed in Carraz et al (2014 Microgravity Sci. Technol . 26 139) and enables high-sensitivity measurements of gravity gradients by using atom interferometers in a differential accelerometer configuration. We present the design of the instrument including its subsystems and analyze the mission scenario, for which we derive the expected instrument performances, the requirements on the sensor and its key subsystems, and the expected impact on the recovery of the Earth gravity field.
- 10 October 2019
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 36 (21) , 215004
Top Cited PapersConcept study and preliminary design of a cold atom interferometer for space gravity gradiometry
We study a space-based gravity gradiometer based on cold atom interferometry and its potential for the Earth’s gravitational field mapping. The instrument architecture has been proposed in Carraz et al (2014 Microgravity Sci. Technol . 26 139) and enables high-sensitivity measurements of gravity gradients by using atom interferometers in a differential accelerometer configuration. We present the design of the instrument including its subsystems and analyze the mission scenario, for which we derive the expected instrument performances, the requirements on the sensor and its key subsystems, and the expected impact on the recovery of the Earth gravity field.
- 28 November 2018
- Published by Oxford University Press (OUP) in Geophysical Journal International
- Vol. 216 (3) , 1594-1607
Clock networks for height system unification: a simulation study
- 28 November 2018
- Published by Oxford University Press (OUP) in Geophysical Journal International
- Vol. 216 (3) , 1594-1607
Clock networks for height system unification: a simulation study
- Open Access
- 1 March 2018
- Published by Elsevier in Advances In Space Research
- Vol. 61 (5) , 1307-1323
Simulation-based evaluation of a cold atom interferometry gradiometer concept for gravity field recovery
- 1 March 2018
- Published by Elsevier in Advances In Space Research
- Vol. 61 (5) , 1307-1323
Open AccessSimulation-based evaluation of a cold atom interferometry gradiometer concept for gravity field recovery