Toji Murabayashi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Toji Murabayashi has a total of 88 co-authors. Here are the top co-authors by number of shared publications:
- Kei Ito
Department of Gastroenterology, Sendai City Medical Center, Sendai, Japan
7 shared publications Shinya Sugimoto
7 shared publications- Takahisa Ogawa
Department of Gastroenterology, Sendai City Medical Center, Sendai, Japan
7 shared publications - Yoshihide Kanno
Department of Gastroenterology, Sendai City Medical Center, Sendai, Japan
7 shared publications - Shinsuke Koshita
Department of Gastroenterology, Sendai City Medical Center, Sendai, Miyagi, Japan
6 shared publications Fumisato Kozakai
Department of Gastroenterology, Sendai City Medical Center, Sendai, Japan
5 shared publications
Latest Publications
- 8 October 2026
- Published by Georg Thieme Verlag KG in Endoscopy
Cholangioscopy-guided lithotripsy versus mechanical lithotripsy for large common bile duct stones during balloon enteroscopy-assisted ERCP after gastrectomy with a native papilla
Background: Balloon enteroscopy-assisted ERCP (BE-ERCP) for large common bile duct stones in patients with surgically altered anatomy (SAA) remains challenging. Mechanical lithotripsy (ML) is commonly used, but stone capture and fragmentation can often be difficult. This study evaluated the usefulness of a peroral cholangioscopy-guided lithotripsy (POCL)-first strategy compared with a conventional ML-first strategy. Methods: This study used a registry of patients with large common bile duct stones and SAA after gastrectomy in whom BE-ERCP was performed at seven institutions in Japan. From this registry, patients treated with an ML-first or POCL-first strategy were included. Outcomes were compared between patients treated with a POCL-first strategy and those treated with an ML-first strategy. The primary outcome was complete stone clearance during the initial session. Results: A total of 104 patients were analyzed: 39 in the POCL-first group and 65 in the ML-first group. Complete stone clearance during the initial session was achieved in 95% of the POCL-first group and 62% of the ML-first group (risk difference, 33.3%; 95% CI, 17.3–46.0%). POCL-first was associated with fewer patients requiring ≥2 sessions among those achieving final clearance (5% vs 32%; risk difference, −27.1%; 95% CI, −40.3 to −11.3). Adverse event rates did not differ significantly. After adjustment, POCL-first was associated with a higher probability of initial-session complete stone clearance (adjusted risk ratio, 1.40; 95% CI, 1.08–1.83). Conclusions: In this retrospective cohort of postgastrectomy patients with an accessible native papilla, a POCL-first strategy during BE-ERCP was associated with higher initial-session complete stone clearance, supporting prospective evaluation.
- 8 October 2026
- Published by Georg Thieme Verlag KG in Endoscopy
Cholangioscopy-guided lithotripsy versus mechanical lithotripsy for large common bile duct stones during balloon enteroscopy-assisted ERCP after gastrectomy with a native papilla
Background: Balloon enteroscopy-assisted ERCP (BE-ERCP) for large common bile duct stones in patients with surgically altered anatomy (SAA) remains challenging. Mechanical lithotripsy (ML) is commonly used, but stone capture and fragmentation can often be difficult. This study evaluated the usefulness of a peroral cholangioscopy-guided lithotripsy (POCL)-first strategy compared with a conventional ML-first strategy. Methods: This study used a registry of patients with large common bile duct stones and SAA after gastrectomy in whom BE-ERCP was performed at seven institutions in Japan. From this registry, patients treated with an ML-first or POCL-first strategy were included. Outcomes were compared between patients treated with a POCL-first strategy and those treated with an ML-first strategy. The primary outcome was complete stone clearance during the initial session. Results: A total of 104 patients were analyzed: 39 in the POCL-first group and 65 in the ML-first group. Complete stone clearance during the initial session was achieved in 95% of the POCL-first group and 62% of the ML-first group (risk difference, 33.3%; 95% CI, 17.3–46.0%). POCL-first was associated with fewer patients requiring ≥2 sessions among those achieving final clearance (5% vs 32%; risk difference, −27.1%; 95% CI, −40.3 to −11.3). Adverse event rates did not differ significantly. After adjustment, POCL-first was associated with a higher probability of initial-session complete stone clearance (adjusted risk ratio, 1.40; 95% CI, 1.08–1.83). Conclusions: In this retrospective cohort of postgastrectomy patients with an accessible native papilla, a POCL-first strategy during BE-ERCP was associated with higher initial-session complete stone clearance, supporting prospective evaluation.
- Open Access
- 30 June 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (S 04) , E792-E793
Novel dye-assisted localization of the minor papilla via a percutaneous drainage catheter for pancreatic duct disruption
Endoscopic pancreatic duct drainage via the minor papilla is occasionally required when drainage via the major papilla is difficult or anatomically unsuitable. However, cannulation of the minor papilla is often technically difficult because it is endoscopically inconspicuous. Several dye-assisted techniques have been reported for localization of the minor papilla, including topical dye spraying, intraductal dye injection, and EUS-guided methylene blue pancreatography.[1] [2] [3] We herein report a case of traumatic complete disruption of the Wirsung duct in which injection of indigo carmine-containing contrast medium through a percutaneous retroperitoneal drainage catheter enabled endoscopic identification of the minor papilla and successful pancreatic duct drainage via the minor papilla. A 77-year-old man was referred to our hospital for management of traumatic pancreatic duct injury. Computed tomography showed a large retroperitoneal fluid collection adjacent to the pancreatic head ([Fig. 1]). Percutaneous drainage of the collection was performed, and the amylase level in the drained fluid was 80,900 U/L, confirming pancreatic juice leakage. Endoscopic retrograde pancreatography via the major papilla showed complete disruption of the Wirsung duct, with contrast leakage into the retroperitoneal cavity and failure of guidewire passage across the disruption site ([Fig. 2]). Several days later, pancreatic duct drainage via the minor papilla was performed ([Fig. 3]; [Video 1]). Because the minor papilla was endoscopically inconspicuous, contrast medium mixed with indigo carmine was injected through the percutaneous retroperitoneal drainage catheter. The dye emerged from the minor papilla, allowing direct endoscopic localization. A guidewire was then advanced through the minor papilla deep into the upstream pancreatic duct, and a 7-Fr plastic stent was placed across the Santorini duct via the minor papilla. Pancreatic juice leakage improved, allowing removal of the percutaneous drainage catheter 2 weeks later. The pancreatic stent was removed 4 months later, with no subsequent recurrence of pancreatic juice leakage. Video 1 Dye-assisted localization of the minor papilla through a percutaneous drainage catheter, followed by endoscopic pancreatic duct drainage via the minor papilla. Endoscopy_UCTN_Code_TTT_1AR_2AK Received: 29 May 2026 Accepted after revision: 16 June 2026 Article published online: 30 June 2026 © 2026. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 30 June 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (S 04) , E792-E793
Open AccessNovel dye-assisted localization of the minor papilla via a percutaneous drainage catheter for pancreatic duct disruption
Endoscopic pancreatic duct drainage via the minor papilla is occasionally required when drainage via the major papilla is difficult or anatomically unsuitable. However, cannulation of the minor papilla is often technically difficult because it is endoscopically inconspicuous. Several dye-assisted techniques have been reported for localization of the minor papilla, including topical dye spraying, intraductal dye injection, and EUS-guided methylene blue pancreatography.[1] [2] [3] We herein report a case of traumatic complete disruption of the Wirsung duct in which injection of indigo carmine-containing contrast medium through a percutaneous retroperitoneal drainage catheter enabled endoscopic identification of the minor papilla and successful pancreatic duct drainage via the minor papilla. A 77-year-old man was referred to our hospital for management of traumatic pancreatic duct injury. Computed tomography showed a large retroperitoneal fluid collection adjacent to the pancreatic head ([Fig. 1]). Percutaneous drainage of the collection was performed, and the amylase level in the drained fluid was 80,900 U/L, confirming pancreatic juice leakage. Endoscopic retrograde pancreatography via the major papilla showed complete disruption of the Wirsung duct, with contrast leakage into the retroperitoneal cavity and failure of guidewire passage across the disruption site ([Fig. 2]). Several days later, pancreatic duct drainage via the minor papilla was performed ([Fig. 3]; [Video 1]). Because the minor papilla was endoscopically inconspicuous, contrast medium mixed with indigo carmine was injected through the percutaneous retroperitoneal drainage catheter. The dye emerged from the minor papilla, allowing direct endoscopic localization. A guidewire was then advanced through the minor papilla deep into the upstream pancreatic duct, and a 7-Fr plastic stent was placed across the Santorini duct via the minor papilla. Pancreatic juice leakage improved, allowing removal of the percutaneous drainage catheter 2 weeks later. The pancreatic stent was removed 4 months later, with no subsequent recurrence of pancreatic juice leakage. Video 1 Dye-assisted localization of the minor papilla through a percutaneous drainage catheter, followed by endoscopic pancreatic duct drainage via the minor papilla. Endoscopy_UCTN_Code_TTT_1AR_2AK Received: 29 May 2026 Accepted after revision: 16 June 2026 Article published online: 30 June 2026 © 2026. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- Open Access
- 30 May 2026
- Published by The Korean Society of Gastrointestinal Endoscopy in Clinical Endoscopy
- Vol. 59 (3) , 425-432
A pilot study of a novel tapered and flared fully covered self-expandable metal stent for unresectable malignant distal biliary obstruction: a multicenter study in Japan
Background/Aims: This study evaluated the feasibility and clinical outcomes of a novel tapered and flared, fully covered, self-expandable metal stent (TF-FCSEMS) for unresectable malignant distal biliary obstruction (UMDBO).Methods: This multicenter retrospective study included 40 patients who underwent transpapillary placement of a TF-FCSEMS (10-mm cylindrical body with an 8-mm tapered distal end) for UMDBO between May 2023 and July 2024. The primary outcome was time to recurrent biliary obstruction (TRBO). Secondary outcomes included technical and clinical successes, adverse events (AEs), and overall survival.Results: Technical and clinical success rates were 100% and 98%, respectively. During a median follow-up period of 271 days, recurrent biliary obstruction (RBO) occurred in 10 (26%) of the 39 patients who achieved clinical success. The median TRBO was 539 days (95% confidence interval, 389–not reached), and the non-RBO rates at 3, 6, and 12 months were 94%, 71%, and 61%, respectively. Symptomatic stent migration occurred in 2 patients (5.1%), while asymptomatic migration was observed in 3 (7.7%). Post-endoscopic retrograde cholangiopancreatography pancreatitis occurred in four patients (10%). Non-occlusion cholangitis developed in five (13%) patients, mostly with tumor-related duodenal stenosis. All AEs were managed conservatively or endoscopically.Conclusions: TF-FCSEMS appears to be a feasible and acceptable treatment option for UMDBO. Further prospective studies are required to confirm these findings.
- 30 May 2026
- Published by The Korean Society of Gastrointestinal Endoscopy in Clinical Endoscopy
- Vol. 59 (3) , 425-432
Open AccessA pilot study of a novel tapered and flared fully covered self-expandable metal stent for unresectable malignant distal biliary obstruction: a multicenter study in Japan
Background/Aims: This study evaluated the feasibility and clinical outcomes of a novel tapered and flared, fully covered, self-expandable metal stent (TF-FCSEMS) for unresectable malignant distal biliary obstruction (UMDBO).Methods: This multicenter retrospective study included 40 patients who underwent transpapillary placement of a TF-FCSEMS (10-mm cylindrical body with an 8-mm tapered distal end) for UMDBO between May 2023 and July 2024. The primary outcome was time to recurrent biliary obstruction (TRBO). Secondary outcomes included technical and clinical successes, adverse events (AEs), and overall survival.Results: Technical and clinical success rates were 100% and 98%, respectively. During a median follow-up period of 271 days, recurrent biliary obstruction (RBO) occurred in 10 (26%) of the 39 patients who achieved clinical success. The median TRBO was 539 days (95% confidence interval, 389–not reached), and the non-RBO rates at 3, 6, and 12 months were 94%, 71%, and 61%, respectively. Symptomatic stent migration occurred in 2 patients (5.1%), while asymptomatic migration was observed in 3 (7.7%). Post-endoscopic retrograde cholangiopancreatography pancreatitis occurred in four patients (10%). Non-occlusion cholangitis developed in five (13%) patients, mostly with tumor-related duodenal stenosis. All AEs were managed conservatively or endoscopically.Conclusions: TF-FCSEMS appears to be a feasible and acceptable treatment option for UMDBO. Further prospective studies are required to confirm these findings.
- Open Access
- 2 April 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (S 02) , E486-E487
Troubleshooting of plastic stent impaction in the working channel during endoscopic ultrasound-guided hepaticogastrostomy
Two previous reports [1] [2] have described plastic stent impaction within the working channel during endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) due to breakage of the thread connecting the stent to its delivery system. In both cases, troubleshooting was performed without scope exchange, resulting in stent fracture. We report successful troubleshooting of this complication by exchanging to a forward-viewing endoscope, which enabled direct visualization and improved pushability through coaxial alignment between the stent delivery system and the endoscope channel. An 84-year-old woman with malignant distal biliary obstruction due to pancreatic cancer underwent EUS-HGS with antegrade stenting after failed transpapillary drainage. Using a convex-array echoendoscope (GF-UCT290; Olympus Medical Systems, Tokyo, Japan), the B3 was punctured transgastrically, and two guidewires (0.025-inch and 0.035-inch) were inserted into the bile duct to establish a double-guidewire technique [3]. After antegrade stenting with a 10-mm uncovered metal stent, a 7-Fr plastic stent (Through & Pass, Type IT; Gadelius Medical, Tokyo, Japan) was advanced over the 0.035-inch guidewire but failed to traverse the bile duct wall. During attempted withdrawal, the connecting thread between the stent and the delivery system broke, resulting in stent impaction within the working channel while the distal tip remained embedded in the hepatic parenchyma ([Fig. 1], [Fig. 2] a). Retrieval was attempted using a Soehendra stent retriever (Cook Medical Japan, Tokyo, Japan) but failed because the retriever tip could not engage the stent. The echoendoscope was carefully withdrawn, leaving the impacted stent and both guidewires in place ([Video 1]). A forward-viewing endoscope (GIF-H290T; Olympus) was then advanced into the stomach over the 0.025-inch guidewire. A new 7-Fr Type IT stent was successfully advanced into the bile duct alongside the impacted stent over the same guidewire ([Fig. 2] b). After deployment of the new stent, the impacted stent was grasped with forceps and removed together with the endoscope ([Fig. 3]). Endoscopy_UCTN_Code_TTT_1AS_2AH Article published online: 15 April 2026 © 2026. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 2 April 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (S 02) , E486-E487
Open AccessTroubleshooting of plastic stent impaction in the working channel during endoscopic ultrasound-guided hepaticogastrostomy
Two previous reports [1] [2] have described plastic stent impaction within the working channel during endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) due to breakage of the thread connecting the stent to its delivery system. In both cases, troubleshooting was performed without scope exchange, resulting in stent fracture. We report successful troubleshooting of this complication by exchanging to a forward-viewing endoscope, which enabled direct visualization and improved pushability through coaxial alignment between the stent delivery system and the endoscope channel. An 84-year-old woman with malignant distal biliary obstruction due to pancreatic cancer underwent EUS-HGS with antegrade stenting after failed transpapillary drainage. Using a convex-array echoendoscope (GF-UCT290; Olympus Medical Systems, Tokyo, Japan), the B3 was punctured transgastrically, and two guidewires (0.025-inch and 0.035-inch) were inserted into the bile duct to establish a double-guidewire technique [3]. After antegrade stenting with a 10-mm uncovered metal stent, a 7-Fr plastic stent (Through & Pass, Type IT; Gadelius Medical, Tokyo, Japan) was advanced over the 0.035-inch guidewire but failed to traverse the bile duct wall. During attempted withdrawal, the connecting thread between the stent and the delivery system broke, resulting in stent impaction within the working channel while the distal tip remained embedded in the hepatic parenchyma ([Fig. 1], [Fig. 2] a). Retrieval was attempted using a Soehendra stent retriever (Cook Medical Japan, Tokyo, Japan) but failed because the retriever tip could not engage the stent. The echoendoscope was carefully withdrawn, leaving the impacted stent and both guidewires in place ([Video 1]). A forward-viewing endoscope (GIF-H290T; Olympus) was then advanced into the stomach over the 0.025-inch guidewire. A new 7-Fr Type IT stent was successfully advanced into the bile duct alongside the impacted stent over the same guidewire ([Fig. 2] b). After deployment of the new stent, the impacted stent was grasped with forceps and removed together with the endoscope ([Fig. 3]). Endoscopy_UCTN_Code_TTT_1AS_2AH Article published online: 15 April 2026 © 2026. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 17 March 2026
- Published by Wiley in Journal of Hepato-Biliary-Pancreatic Sciences
- Vol. 33 (8) , 649-659
Above‐ Versus Across‐The‐Papilla Plastic Stent Placement for Malignant Hilar Biliary Obstruction in Unresectable Biliary Tract Cancer: A Multicentre IPTW Analysis
Background: Maintaining effective biliary drainage is crucial in the era of prolonged chemotherapy for biliary tract cancer (BTC). Plastic stents (PS) are widely used in malignant hilar biliary obstruction (MHBO); nonetheless, the optimal placement (above‐ vs. across‐the‐papilla) remains controversial. Methods: In this multicentre retrospective study, 246 patients with unresectable BTC‐related MHBO who underwent clinically successful PS placement between April 2016 and August 2024 were analyzed. Patients were classified into the above‐the‐papilla ( n = 197) and across‐the‐papilla ( n = 49) groups. Baseline imbalances were adjusted using inverse probability of treatment weighting (IPTW) with “average treatment effect on the treated”. Covariates included age, sex, primary disease, Bismuth classification, cholangitis, prior drainage, and number of stents. The primary outcome was time to recurrent biliary obstruction (TRBO); secondary outcomes included overall survival (OS) and adverse events (AEs). Results: After IPTW adjustment, effective sample sizes were 47.6 (above‐the‐papilla group) and 49.0 (across‐the‐papilla group). The median TRBO was significantly longer in the above‐the‐papilla group (114 vs. 66 days; p = 0.02), with a hazard ratio of 1.62 (95% confidence interval: 0.97–2.70). OS (457 vs. 366 days; p = 0.99) and AE rates were comparable. Conclusions: Above‐the‐papilla PS placement may prolong stent patency without compromising safety in patients with unresectable BTC‐related MHBO.
- 17 March 2026
- Published by Wiley in Journal of Hepato-Biliary-Pancreatic Sciences
- Vol. 33 (8) , 649-659
Above‐ Versus Across‐The‐Papilla Plastic Stent Placement for Malignant Hilar Biliary Obstruction in Unresectable Biliary Tract Cancer: A Multicentre IPTW Analysis
Background: Maintaining effective biliary drainage is crucial in the era of prolonged chemotherapy for biliary tract cancer (BTC). Plastic stents (PS) are widely used in malignant hilar biliary obstruction (MHBO); nonetheless, the optimal placement (above‐ vs. across‐the‐papilla) remains controversial. Methods: In this multicentre retrospective study, 246 patients with unresectable BTC‐related MHBO who underwent clinically successful PS placement between April 2016 and August 2024 were analyzed. Patients were classified into the above‐the‐papilla ( n = 197) and across‐the‐papilla ( n = 49) groups. Baseline imbalances were adjusted using inverse probability of treatment weighting (IPTW) with “average treatment effect on the treated”. Covariates included age, sex, primary disease, Bismuth classification, cholangitis, prior drainage, and number of stents. The primary outcome was time to recurrent biliary obstruction (TRBO); secondary outcomes included overall survival (OS) and adverse events (AEs). Results: After IPTW adjustment, effective sample sizes were 47.6 (above‐the‐papilla group) and 49.0 (across‐the‐papilla group). The median TRBO was significantly longer in the above‐the‐papilla group (114 vs. 66 days; p = 0.02), with a hazard ratio of 1.62 (95% confidence interval: 0.97–2.70). OS (457 vs. 366 days; p = 0.99) and AE rates were comparable. Conclusions: Above‐the‐papilla PS placement may prolong stent patency without compromising safety in patients with unresectable BTC‐related MHBO.
- Open Access
- 1 January 2026
- Published by Wiley in Case Reports in Gastrointestinal Medicine
- Vol. 2026 (1) , 3485630
Endoscopic Nasogallbladder Drainage for Acute Cholecystitis in a Patient With Situs Inversus Totalis: A Case Report
Situs inversus totalis (SIT) is a rare congenital condition characterized by complete mirror‐image transposition of the thoracic and abdominal organs. Endoscopic transpapillary gallbladder drainage (ETGBD) can be technically challenging in patients with SIT, and, to our knowledge, has not previously been reported in this anatomical setting. We report a case of successful endoscopic nasogallbladder drainage (ENGBD) for acute cholecystitis in a patient with SIT. A 72‐year‐old man with SIT presented with fever and left hypochondrial pain. Computed tomography revealed acute calculous cholecystitis and a common bile duct stone. After removal of the common bile duct stone by endoscopic retrograde cholangiopancreatography, a guidewire was advanced across the obstructed segment of the cystic duct into the gallbladder, and a 6‐Fr ENGBD tube was successfully placed. The patient improved after drainage and subsequently underwent elective laparoscopic cholecystectomy. This case suggests that ETGBD, including ENGBD, may be feasible in patients with SIT when a stable papillary view and guidewire access to the gallbladder can be achieved.
- 1 January 2026
- Published by Wiley in Case Reports in Gastrointestinal Medicine
- Vol. 2026 (1) , 3485630
Open AccessEndoscopic Nasogallbladder Drainage for Acute Cholecystitis in a Patient With Situs Inversus Totalis: A Case Report
Situs inversus totalis (SIT) is a rare congenital condition characterized by complete mirror‐image transposition of the thoracic and abdominal organs. Endoscopic transpapillary gallbladder drainage (ETGBD) can be technically challenging in patients with SIT, and, to our knowledge, has not previously been reported in this anatomical setting. We report a case of successful endoscopic nasogallbladder drainage (ENGBD) for acute cholecystitis in a patient with SIT. A 72‐year‐old man with SIT presented with fever and left hypochondrial pain. Computed tomography revealed acute calculous cholecystitis and a common bile duct stone. After removal of the common bile duct stone by endoscopic retrograde cholangiopancreatography, a guidewire was advanced across the obstructed segment of the cystic duct into the gallbladder, and a 6‐Fr ENGBD tube was successfully placed. The patient improved after drainage and subsequently underwent elective laparoscopic cholecystectomy. This case suggests that ETGBD, including ENGBD, may be feasible in patients with SIT when a stable papillary view and guidewire access to the gallbladder can be achieved.
- Open Access
- 1 January 2026
- Published by S. Karger AG in Case Reports in Gastroenterology
- Vol. 20 (1) , 276-281
Prolonged Retention of a Spontaneously Dislodging Pancreatic Duct Stent in a Patient with Surgically Altered Anatomy: A Case Report
Introduction: Spontaneously dislodging pancreatic duct stents are generally expected to pass within several days. We report a rare case of markedly prolonged retention of such a stent in a patient with surgically altered anatomy. Case Presentation: A 78-year-old man with a history of distal gastrectomy with Roux-en-Y reconstruction underwent single-balloon enteroscopy-assisted ERCP for choledocholithiasis. After successful biliary cannulation using pancreatic guidewire assistance, stone extraction was performed following a small sphincterotomy and papillary balloon dilation. A 5-Fr × 5-cm spontaneously dislodging pancreatic duct stent without an internal flange was prophylactically placed. The postoperative course was uneventful; however, spontaneous stent dislodgement was not observed on follow-up imaging. Because of the technical burden of repeat endoscopy in surgically altered anatomy, careful observation was initially selected. The stent remained in place for 104 days and was ultimately removed endoscopically using a single-balloon enteroscope without adverse events. Conclusion: This case illustrates that markedly prolonged retention of a spontaneously dislodging pancreatic duct stent may occur in patients with surgically altered anatomy. Careful follow-up, including imaging to confirm spontaneous stent passage, is important, and endoscopic removal should be considered when the stent remains in place, even if repeat endoscopy is technically challenging.
- 1 January 2026
- Published by S. Karger AG in Case Reports in Gastroenterology
- Vol. 20 (1) , 276-281
Open AccessProlonged Retention of a Spontaneously Dislodging Pancreatic Duct Stent in a Patient with Surgically Altered Anatomy: A Case Report
Introduction: Spontaneously dislodging pancreatic duct stents are generally expected to pass within several days. We report a rare case of markedly prolonged retention of such a stent in a patient with surgically altered anatomy. Case Presentation: A 78-year-old man with a history of distal gastrectomy with Roux-en-Y reconstruction underwent single-balloon enteroscopy-assisted ERCP for choledocholithiasis. After successful biliary cannulation using pancreatic guidewire assistance, stone extraction was performed following a small sphincterotomy and papillary balloon dilation. A 5-Fr × 5-cm spontaneously dislodging pancreatic duct stent without an internal flange was prophylactically placed. The postoperative course was uneventful; however, spontaneous stent dislodgement was not observed on follow-up imaging. Because of the technical burden of repeat endoscopy in surgically altered anatomy, careful observation was initially selected. The stent remained in place for 104 days and was ultimately removed endoscopically using a single-balloon enteroscope without adverse events. Conclusion: This case illustrates that markedly prolonged retention of a spontaneously dislodging pancreatic duct stent may occur in patients with surgically altered anatomy. Careful follow-up, including imaging to confirm spontaneous stent passage, is important, and endoscopic removal should be considered when the stent remains in place, even if repeat endoscopy is technically challenging.
- Open Access
- 14 January 2025
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 57 (S 01) , E493-E494
Troubleshooting for perforation due to proximal metal stent displacement in endoscopic ultrasound-guided hepaticogastrostomy
Partially covered self-expandable metal stents (PCSEMS) are frequently used in endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS). When the proximal end of the uncovered portion of a PCSEMS is positioned more proximally than the hepatic parenchyma, persistent bile leakage into the peritoneal cavity may occur even if the stent tip remains within the bile duct. Here, we report a technique to salvage this type of perforation. A 57-year-old man with unresectable hilar cholangiocarcinoma, who had previously undergone multiple transpapillary plastic stent placements in the bile duct, underwent EUS-HGS for recurrent biliary obstruction with gastric outlet obstruction ([Fig. 1], [Video 1]). After puncturing with a 19-gauge needle and performing cholangiography, a PCSEMS with a 2 cm uncovered portion at the tip (Spring Stopper, 8 × 100 mm; TaeWoong Medical) was placed from B3 to the stomach. However, the stent migrated proximally during deployment, and the proximal end of the uncovered portion was inadvertently positioned within the peritoneal cavity. To address this complication, a guidewire was inserted into the PCSEMS and the bile duct via the side of the PCSEMS near the gastric wall by puncturing its membrane with a standard catheter under direct endoscopic visualization using a duodenoscope. Subsequently, a fully covered self-expandable metal stent (FCSEMS; 10 × 80 mm) was placed from the bile duct to the stomach, covering all uncovered portions of the PCSEMS. This successfully sealed the perforation and restored effective drainage ([Fig. 2]). Matsubara et al. [1] previously reported managing the same complication by placing an additional FCSEMS using a different technique. They created an access route into the PCSEMS and bile ducts by puncturing with a 19-gauge needle through the gastric wall and hepatic parenchyma. Our approach offers advantages over their method, as it is not only technically simpler but also reduces the risk of gastric content leakage into the peritoneal cavity. Endoscopy_UCTN_Code_CPL_1AL_2AD Article published online: 26 May 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 14 January 2025
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 57 (S 01) , E493-E494
Open AccessTroubleshooting for perforation due to proximal metal stent displacement in endoscopic ultrasound-guided hepaticogastrostomy
Partially covered self-expandable metal stents (PCSEMS) are frequently used in endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS). When the proximal end of the uncovered portion of a PCSEMS is positioned more proximally than the hepatic parenchyma, persistent bile leakage into the peritoneal cavity may occur even if the stent tip remains within the bile duct. Here, we report a technique to salvage this type of perforation. A 57-year-old man with unresectable hilar cholangiocarcinoma, who had previously undergone multiple transpapillary plastic stent placements in the bile duct, underwent EUS-HGS for recurrent biliary obstruction with gastric outlet obstruction ([Fig. 1], [Video 1]). After puncturing with a 19-gauge needle and performing cholangiography, a PCSEMS with a 2 cm uncovered portion at the tip (Spring Stopper, 8 × 100 mm; TaeWoong Medical) was placed from B3 to the stomach. However, the stent migrated proximally during deployment, and the proximal end of the uncovered portion was inadvertently positioned within the peritoneal cavity. To address this complication, a guidewire was inserted into the PCSEMS and the bile duct via the side of the PCSEMS near the gastric wall by puncturing its membrane with a standard catheter under direct endoscopic visualization using a duodenoscope. Subsequently, a fully covered self-expandable metal stent (FCSEMS; 10 × 80 mm) was placed from the bile duct to the stomach, covering all uncovered portions of the PCSEMS. This successfully sealed the perforation and restored effective drainage ([Fig. 2]). Matsubara et al. [1] previously reported managing the same complication by placing an additional FCSEMS using a different technique. They created an access route into the PCSEMS and bile ducts by puncturing with a 19-gauge needle through the gastric wall and hepatic parenchyma. Our approach offers advantages over their method, as it is not only technically simpler but also reduces the risk of gastric content leakage into the peritoneal cavity. Endoscopy_UCTN_Code_CPL_1AL_2AD Article published online: 26 May 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- Open Access
Pancreatic stent migration into the main pancreatic duct during endoscopic papillary balloon dilation
We report the first case of pancreatic stent (PS) migration placed early into the main pancreatic duct (MPD) during endoscopic retrograde cholangiopancreatography (ERCP) due to subsequent endoscopic papillary balloon dilation. A 74‐year‐old woman who complained of fever and abdominal pain was diagnosed with acute calculous cholangitis. On ERCP, a needle‐knife precut papillotomy was performed from the orifice because of difficult cannulation. Because of unintentional guidewire insertion into the MPD from the orifice, a PS with bilateral flaps was promptly placed to prevent post‐ERCP pancreatitis. After successful biliary cannulation from the orifice alongside the PS, endoscopic papillary balloon dialtion was performed, leading to PS migration into the MPD during the dilation. Two days after the first ERCP, the migrated PS was successfully removed on the second ERCP. The strategy of early PS placement in the ERCP session appears theoretically promising for preventing post‐ERCP pancreatitis. However, early PS placement during the ERCP session should be noted to pose the risk of migration into the MPD, especially when pushing the device into the bile duct.
Open AccessPancreatic stent migration into the main pancreatic duct during endoscopic papillary balloon dilation
We report the first case of pancreatic stent (PS) migration placed early into the main pancreatic duct (MPD) during endoscopic retrograde cholangiopancreatography (ERCP) due to subsequent endoscopic papillary balloon dilation. A 74‐year‐old woman who complained of fever and abdominal pain was diagnosed with acute calculous cholangitis. On ERCP, a needle‐knife precut papillotomy was performed from the orifice because of difficult cannulation. Because of unintentional guidewire insertion into the MPD from the orifice, a PS with bilateral flaps was promptly placed to prevent post‐ERCP pancreatitis. After successful biliary cannulation from the orifice alongside the PS, endoscopic papillary balloon dialtion was performed, leading to PS migration into the MPD during the dilation. Two days after the first ERCP, the migrated PS was successfully removed on the second ERCP. The strategy of early PS placement in the ERCP session appears theoretically promising for preventing post‐ERCP pancreatitis. However, early PS placement during the ERCP session should be noted to pose the risk of migration into the MPD, especially when pushing the device into the bile duct.
- Open Access
- 9 January 2024
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 56 (S 01) , E283-E284
Novel technique of additional anchor plastic stent placement during endoscopic ultrasound-guided gallbladder drainage
A fully covered self-expanding metal stent (FCSEMS) is frequently used for endoscopic ultrasound-guided gallbladder drainage (EUS-GBD) in some countries where the use of lumen-apposing metal stent for EUS-GBD is not approved [1] [2]. Coaxial placement of a double-pigtail plastic stent (DPPS) as an anchor within the FCSEMS for EUS-GBD is preferred to prevent food impaction, delayed bleeding, and stent migration [2] [3]. However, placing the additional stent through the distal end of the FCSEMS can be challenging and risky, as the pushing force of the DPPS may be transmitted to an inappropriate axis on the bent portion of the long FCSEMS ([Fig. 1] a). We developed a novel technique to overcome these technical difficulties ([Fig. 1] b). A 75-year-old woman with unresectable distal bile duct cancer who had previously undergone FCSEMS placement in the bile duct underwent EUS-GBD for acute cholecystitis ([Fig. 2]). Following puncture with a 19-gauge needle and dilation with a 4-mm balloon dilator, an FCSEMS (HANAROSTENT Benefit, 8 × 100 mm) was deployed from the gallbladder to the duodenum. As 6 cm of the FCSEMS was positioned in the duodenum, additional placement of a plastic stent through the distal end of the FCSEMS appeared to be technically challenging. Therefore, we placed a plastic stent using a novel technique ([Video 1], [Fig. 3]). A standard catheter and guidewire were inserted into the FCSEMS and gallbladder from the side of the FCSEMS near the duodenal wall after puncturing the membrane of the FCSEMS using the catheter under direct endoscopic visualization. A DPPS (7-Fr × 7 cm) was inserted into the gallbladder through the guidewire without dilation. It was positioned as a bridge connecting the gallbladder, FCSEMS, and duodenum in a lambda-shaped configuration. Using this novel technique, additional DPPSs can be readily placed, even in cases where an exceptionally long portion of FCSEMS is located in the duodenum. Endoscopy_UCTN_Code_TTT_1AS_2AH Article published online: 20 March 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 9 January 2024
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 56 (S 01) , E283-E284
Open AccessNovel technique of additional anchor plastic stent placement during endoscopic ultrasound-guided gallbladder drainage
A fully covered self-expanding metal stent (FCSEMS) is frequently used for endoscopic ultrasound-guided gallbladder drainage (EUS-GBD) in some countries where the use of lumen-apposing metal stent for EUS-GBD is not approved [1] [2]. Coaxial placement of a double-pigtail plastic stent (DPPS) as an anchor within the FCSEMS for EUS-GBD is preferred to prevent food impaction, delayed bleeding, and stent migration [2] [3]. However, placing the additional stent through the distal end of the FCSEMS can be challenging and risky, as the pushing force of the DPPS may be transmitted to an inappropriate axis on the bent portion of the long FCSEMS ([Fig. 1] a). We developed a novel technique to overcome these technical difficulties ([Fig. 1] b). A 75-year-old woman with unresectable distal bile duct cancer who had previously undergone FCSEMS placement in the bile duct underwent EUS-GBD for acute cholecystitis ([Fig. 2]). Following puncture with a 19-gauge needle and dilation with a 4-mm balloon dilator, an FCSEMS (HANAROSTENT Benefit, 8 × 100 mm) was deployed from the gallbladder to the duodenum. As 6 cm of the FCSEMS was positioned in the duodenum, additional placement of a plastic stent through the distal end of the FCSEMS appeared to be technically challenging. Therefore, we placed a plastic stent using a novel technique ([Video 1], [Fig. 3]). A standard catheter and guidewire were inserted into the FCSEMS and gallbladder from the side of the FCSEMS near the duodenal wall after puncturing the membrane of the FCSEMS using the catheter under direct endoscopic visualization. A DPPS (7-Fr × 7 cm) was inserted into the gallbladder through the guidewire without dilation. It was positioned as a bridge connecting the gallbladder, FCSEMS, and duodenum in a lambda-shaped configuration. Using this novel technique, additional DPPSs can be readily placed, even in cases where an exceptionally long portion of FCSEMS is located in the duodenum. Endoscopy_UCTN_Code_TTT_1AS_2AH Article published online: 20 March 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany