Irena Szadkowska-Stańczyk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Irena Szadkowska-Stańczyk has a total of 104 co-authors. Here are the top co-authors by number of shared publications:
- Anna Kozajda
Nofer Institute of Occupational Medicine, Łódź, Poland (Biological Safety Unit)
25 shared publications - Marcin Cyprowski
Central Institute for Labour Protections - National Research Institute, Warsaw, Poland (Department of Chemical, Aerosol and Biological Hazards, Laboratory of Biohazards)
10 shared publications - Małgorzata Sowiak
Nofer Institute of Occupational Medicine, Łódź, Poland (Department of Environmental Health Hazards).
9 shared publications - Alina Buczyńska
Załdad Srodowiskowych Zagrozeń Zdrowia, Instytut Medycyny Pracy im. prof. J. Nofera, Łódź
8 shared publications - Stella Bujak-Pietrek
Instytut Medycyny Pracy w Łodzi
7 shared publications - Urszula Mikołajczyk
Instytut Medycyny Pracy im. prof. J. Nofera / Nofer Institute of Occupational Medicine, Łódź, Poland (Zakład Środowiskowych Zagrożeń Zdrowia / Department of Environmental Health Hazards).
7 shared publications
Latest Publications
- Open Access
- 5 December 2017
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 25 (5) , 5013-5023
Does the air condition system in busses spread allergic fungi into driver space?
The aim of this study was to establish whether the air-conditioning system in buses constitutes an additional source of indoor air contamination with fungi, and whether or not the fungi concentration depends on the period from the last disinfection of the system, combined with replacement of the cabin dust particle filter. The air samples to fungi analysis using impact method were taken in 30 buses (20 with an air-conditioning system, ACS; 10 with a ventilation system, VS) in two series: 1 and 22 weeks after cabin filter replacement and disinfection of the air-conditioning system. During one test in each bus were taken two samples: before the air-conditioning or ventilation system switched on and 6 min after operating of these systems. The atmospheric air was the external background (EB). After 1 week of use of the system, the fungi concentrations before starting of the ACS and VS system were 527.8 and 1053.0 cfu/m3, respectively, and after 22 weeks the concentrations were 351.9 and 1069.6 cfu/m3, respectively. While in the sample after 6 min of ACS and VS system operating, the fungi concentration after 1 week of use was 127.6 and 233.7 cfu/m3, respectively, and after 22 weeks it was 113.3 and 324.9 cfu/m3, respectively. Results do not provide strong evidence that air-conditioning system is an additional source of indoor air contamination with fungi. A longer operation of the system promoted increase of fungi concentration in air-conditioned buses only.
- 5 December 2017
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 25 (5) , 5013-5023
Open AccessDoes the air condition system in busses spread allergic fungi into driver space?
The aim of this study was to establish whether the air-conditioning system in buses constitutes an additional source of indoor air contamination with fungi, and whether or not the fungi concentration depends on the period from the last disinfection of the system, combined with replacement of the cabin dust particle filter. The air samples to fungi analysis using impact method were taken in 30 buses (20 with an air-conditioning system, ACS; 10 with a ventilation system, VS) in two series: 1 and 22 weeks after cabin filter replacement and disinfection of the air-conditioning system. During one test in each bus were taken two samples: before the air-conditioning or ventilation system switched on and 6 min after operating of these systems. The atmospheric air was the external background (EB). After 1 week of use of the system, the fungi concentrations before starting of the ACS and VS system were 527.8 and 1053.0 cfu/m3, respectively, and after 22 weeks the concentrations were 351.9 and 1069.6 cfu/m3, respectively. While in the sample after 6 min of ACS and VS system operating, the fungi concentration after 1 week of use was 127.6 and 233.7 cfu/m3, respectively, and after 22 weeks it was 113.3 and 324.9 cfu/m3, respectively. Results do not provide strong evidence that air-conditioning system is an additional source of indoor air contamination with fungi. A longer operation of the system promoted increase of fungi concentration in air-conditioned buses only.
- Open Access
- 26 May 2017
- Published by Springer Nature in Aerobiologia
- Vol. 33 (4) , 481-491
Inhalable dust, endotoxins and (1–3)-β-d-glucans as indicators of exposure in waste sorting plant environment
The aim of the study was to assess the levels of inhalable dust, endotoxins and (1–3)-β-d-glucans as agents harmful to the respiratory tract of workers of municipal waste sorting plants and interaction between these agents based on the measurements taken in two plants with different processing capacities. The study was conducted in summer season in two waste sorting plants (WSPs) differing in processing capacity. Samples of bioaerosol for inhalable dust (gravimetric method), endotoxins (LAL test in kinetic, chromogenic version) and (1–3)-β-d-glucans (Glucatell test in kinetic version) were collected from 42 sorting workers using individual aspirators with glass fiber filters during the work shift. Average geometric concentrations (geometric standard deviation; min–max) of inhalable dust, endotoxins and (1–3)-β-d-glucans were: WSP1: 1.7 mg m−3 (2.2; 0.6–6.9 mg m−3); 15.9 ng m−3 (2.1; 5.4–78.9 ng m−3), 55.1 ng m−3 (1.8; 20.7–188.6 ng m−3) and WSP2: 0.8 mg m−3 (2.2; 0.2–3.8 mg m−3), 9.8 ng m−3 (2.4; 1.6–29.7 ng m−3), 45.0 ng m−3 (3.2, 5.7–212.9 ng m−3), respectively. A significantly higher concentration of inhalable dust was recorded in WSP1 with bigger processing capacity compared to WSP2 (less processing capacity). Significant (p < 0.05) and very high correlations (Spearman rank R > 0.7) were found between the concentrations of all analyzed harmful agents. Processing capacity of waste sorting plants differentially affects the concentrations of inhalable dust, whereas concentrations of endotoxins and glucans are less clearly affected. This suggests that relative concentrations of endotoxin and glucan are depending on the waste sorting capacity.
- 26 May 2017
- Published by Springer Nature in Aerobiologia
- Vol. 33 (4) , 481-491
Open AccessInhalable dust, endotoxins and (1–3)-β-d-glucans as indicators of exposure in waste sorting plant environment
The aim of the study was to assess the levels of inhalable dust, endotoxins and (1–3)-β-d-glucans as agents harmful to the respiratory tract of workers of municipal waste sorting plants and interaction between these agents based on the measurements taken in two plants with different processing capacities. The study was conducted in summer season in two waste sorting plants (WSPs) differing in processing capacity. Samples of bioaerosol for inhalable dust (gravimetric method), endotoxins (LAL test in kinetic, chromogenic version) and (1–3)-β-d-glucans (Glucatell test in kinetic version) were collected from 42 sorting workers using individual aspirators with glass fiber filters during the work shift. Average geometric concentrations (geometric standard deviation; min–max) of inhalable dust, endotoxins and (1–3)-β-d-glucans were: WSP1: 1.7 mg m−3 (2.2; 0.6–6.9 mg m−3); 15.9 ng m−3 (2.1; 5.4–78.9 ng m−3), 55.1 ng m−3 (1.8; 20.7–188.6 ng m−3) and WSP2: 0.8 mg m−3 (2.2; 0.2–3.8 mg m−3), 9.8 ng m−3 (2.4; 1.6–29.7 ng m−3), 45.0 ng m−3 (3.2, 5.7–212.9 ng m−3), respectively. A significantly higher concentration of inhalable dust was recorded in WSP1 with bigger processing capacity compared to WSP2 (less processing capacity). Significant (p < 0.05) and very high correlations (Spearman rank R > 0.7) were found between the concentrations of all analyzed harmful agents. Processing capacity of waste sorting plants differentially affects the concentrations of inhalable dust, whereas concentrations of endotoxins and glucans are less clearly affected. This suggests that relative concentrations of endotoxin and glucan are depending on the waste sorting capacity.
- 1 March 2017
- Published by Elsevier in Regulatory Toxicology and Pharmacology
- Vol. 84, 18-25
Modeling emissions from CAFO poultry farms in Poland and evaluating potential risk to surrounding populations
- 1 March 2017
- Published by Elsevier in Regulatory Toxicology and Pharmacology
- Vol. 84, 18-25
Modeling emissions from CAFO poultry farms in Poland and evaluating potential risk to surrounding populations
- Open Access
- 27 July 2016
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 29 (5) , 823-836
The capability of fungi isolated from moldy dwellings to produce toxins
Objectives: The main objective was analysis and assessment of toxinogenic capabilities of fungi isolated from moldy surfaces in residential rooms in an urban agglomeration situated far from flooded areas in moderate climate zone. Material and Methods: The assessment of environmental exposure...
- 27 July 2016
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 29 (5) , 823-836
Open AccessThe capability of fungi isolated from moldy dwellings to produce toxins
Objectives: The main objective was analysis and assessment of toxinogenic capabilities of fungi isolated from moldy surfaces in residential rooms in an urban agglomeration situated far from flooded areas in moderate climate zone. Material and Methods: The assessment of environmental exposure...
- Open Access
- 4 July 2016
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 29 (4) , 667-682
Exposure to diesel exhaust fumes in the context of exposure to ultrafine particles
Objectives: Diesel exhaust fumes emission is a significant source of ultrafine particles, the size of which is expressed in nanometers. People occupationally exposed to diesel exhaust particles include mainly workers servicing vehicles with engines of this type. This article presents the...
- 4 July 2016
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 29 (4) , 667-682
Open AccessExposure to diesel exhaust fumes in the context of exposure to ultrafine particles
Objectives: Diesel exhaust fumes emission is a significant source of ultrafine particles, the size of which is expressed in nanometers. People occupationally exposed to diesel exhaust particles include mainly workers servicing vehicles with engines of this type. This article presents the...
- Open Access
- 17 July 2015
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 28 (5) , 813-821
Assessment of exposure to fungi in the heavily contaminated work environment (a solid waste sorting plant) based on the ergosterol analysis
This paper reports on the results of the study aimed at application of ergosterol as an quantitative indicator of fungal bioaerosol present in the indoor air in occupational environment heavily contaminated with organic dust as well as its comparison with the culturable method.
- 17 July 2015
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 28 (5) , 813-821
Open AccessAssessment of exposure to fungi in the heavily contaminated work environment (a solid waste sorting plant) based on the ergosterol analysis
This paper reports on the results of the study aimed at application of ergosterol as an quantitative indicator of fungal bioaerosol present in the indoor air in occupational environment heavily contaminated with organic dust as well as its comparison with the culturable method.
- Open Access
- 3 July 2015
- Published by Nofer Institute of Occupational Medicine in Medycyna Pracy
- Vol. 66 (3) , 317-326
Worker exposure to ultrafine particles during carbon black treatment
The aim of the project was to assess the exposure of workers to ultrafine particles released during handling and packing of carbon black. The assessment included the results of the measurements performed in a carbon black handling plant before, during, and after work shift. The number concentration of particles within the dimension range 10-1000 nm and 10-100 nm was assayed by a condensation particle counter (CPC). The mass concentration of particles was determined by a DustTrak II DRX aerosol concentration monitor. The surface area concentration of the particles potentially deposited in the alveolar (A) and tracheo-bronchial (TB) regions was estimated by an AeroTrak 9000 nanoparticle monitor. An average mass concentration of particles during the process was 6-fold higher than that before its start, while a 3-fold increase in the average number concentration of particles within the dimension range 10-1000 nm and 10-100 nm was observed during the process. At the same time a 4-fold increase was found in the surface area concentration of the particles potentially deposited in the A and TB regions. During the process of carbon black handling and packing a significantly higher values of each of the analysed parameters, characterizing the exposure to ultrafine particles, were noted.
- 3 July 2015
- Published by Nofer Institute of Occupational Medicine in Medycyna Pracy
- Vol. 66 (3) , 317-326
Open AccessWorker exposure to ultrafine particles during carbon black treatment
The aim of the project was to assess the exposure of workers to ultrafine particles released during handling and packing of carbon black. The assessment included the results of the measurements performed in a carbon black handling plant before, during, and after work shift. The number concentration of particles within the dimension range 10-1000 nm and 10-100 nm was assayed by a condensation particle counter (CPC). The mass concentration of particles was determined by a DustTrak II DRX aerosol concentration monitor. The surface area concentration of the particles potentially deposited in the alveolar (A) and tracheo-bronchial (TB) regions was estimated by an AeroTrak 9000 nanoparticle monitor. An average mass concentration of particles during the process was 6-fold higher than that before its start, while a 3-fold increase in the average number concentration of particles within the dimension range 10-1000 nm and 10-100 nm was observed during the process. At the same time a 4-fold increase was found in the surface area concentration of the particles potentially deposited in the A and TB regions. During the process of carbon black handling and packing a significantly higher values of each of the analysed parameters, characterizing the exposure to ultrafine particles, were noted.
- Open Access
- 25 June 2015
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 28 (5) , 803-811
Endotoxin exposure and changes in short-term pulmonary function among sewage workers
Objectives: The inhaled endotoxin is considered as a causative factor in the process of acute bronchial obstruction, which can be measured by a decrease in forced expiratory volume in 1 s (FEV 1 ). The aim of this study was to assess endotoxin exposure among sewage treatment plant workers...
- 25 June 2015
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 28 (5) , 803-811
Open AccessEndotoxin exposure and changes in short-term pulmonary function among sewage workers
Objectives: The inhaled endotoxin is considered as a causative factor in the process of acute bronchial obstruction, which can be measured by a decrease in forced expiratory volume in 1 s (FEV 1 ). The aim of this study was to assess endotoxin exposure among sewage treatment plant workers...
- Open Access
- 6 March 2015
- Published by Nofer Institute of Occupational Medicine in Medycyna Pracy
Archive About the Journal Instructions for Authors Instructions for Reviewers Editorial Office Editorial Board Contact Reviewers 2013 2014 < PREVIOUS NEXT > ORIGINAL PAPER CC BY-NC 3.0 Polska Occupational exposure to biological agents intentionally used in Polish enterprises
- 6 March 2015
- Published by Nofer Institute of Occupational Medicine in Medycyna Pracy
Open AccessArchive About the Journal Instructions for Authors Instructions for Reviewers Editorial Office Editorial Board Contact Reviewers 2013 2014 < PREVIOUS NEXT > ORIGINAL PAPER CC BY-NC 3.0 Polska Occupational exposure to biological agents intentionally used in Polish enterprises
- Open Access
- 28 February 2015
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 28 (1) , 130-146
Visible fungi growth and dampness assessed using a questionnaire versus airborne fungi, (1→3)-β-d-glucan and fungal spore concentrations in flats
Introduction: The study aimed at determination of the usefulness of the subjective assessment of selected signs of fungi growth in flats and microclimate parameters to indicate the actual air contamination with culturable fungi, (1→3)-β-D-glucans and fungal spores. Material and methods:...
- 28 February 2015
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 28 (1) , 130-146
Open AccessVisible fungi growth and dampness assessed using a questionnaire versus airborne fungi, (1→3)-β-d-glucan and fungal spore concentrations in flats
Introduction: The study aimed at determination of the usefulness of the subjective assessment of selected signs of fungi growth in flats and microclimate parameters to indicate the actual air contamination with culturable fungi, (1→3)-β-D-glucans and fungal spores. Material and methods:...