Tanyong Wei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Tanyong Wei has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Dong Sun
Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong, China
7 shared publications - Shuxun Chen
Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
3 shared publications - Chaoyang Shi
School of Mechanical Engineering Key Laboratory of Mechanism Theory and Equipment Design of Ministry of Education Tianjin University Tianjin China
2 shared publications - Chengzhi Hu
Shenzhen Key Laboratory of Biomimetic Robotics and Intelligent Systems, Department of Mechanical and Energy Engineering, Southern University of Science and Technology, Shenzhen, China
2 shared publications - Lei Fan
Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
2 shared publications Ruifeng Hu
Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pittsburgh, PA, 15260, USA
2 shared publications
Latest Publications
- 1 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (6) , 7089-7099
Rotating Multibarreled Capsule Robot for Multiple Biopsies and On-Demand Drug Delivery
Biopsy and drug delivery are critical functions performed by capsule robots to facilitate noninvasive diagnostic and therapeutic procedures for digestive tract diseases. In this study, we proposed a compact rotating multibarreled design for capsule robots that enables selective operation for either multiple biopsies or on-demand drug delivery. Each barrel can accommodate either a biopsy needle or a drug, providing flexibility to tailor the functions of the capsule robot to specific clinical needs. A motorized lead screw mechanism was employed to initiate the operations for tissue biopsy or drug release, while the transition between biopsy and drug delivery modes is facilitated by the motorized rotation of a cylinder that houses all the barrels. A robotic arm equipped with a permanent magnet as its end effector was used to achieve various motion controls for the capsule robot, including sliding, rolling, rotating, and pitching in different directions. Ex vivo experiments conducted in a porcine stomach demonstrated the successful sampling of human gastric tumors at three specific lesions, yielding an average sample volume of approximately 0.6 mm$^{3}$. Furthermore, we confirmed that the biopsy can penetrate the mucosal and submucosal layers of gastric tissue, allowing for tissue collection deep within the muscular layer. Additionally, the robot exhibited precise drug delivery capabilities, accurately administering multiple types of drugs to various lesions, achieving an average delivery rate of approximately 75% of the barrel's full capacity. The multifunctional and versatile design of the capsule robot presents great potential for advanced and tailored treatments in gastroenterology.
- 1 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (6) , 7089-7099
Rotating Multibarreled Capsule Robot for Multiple Biopsies and On-Demand Drug Delivery
Biopsy and drug delivery are critical functions performed by capsule robots to facilitate noninvasive diagnostic and therapeutic procedures for digestive tract diseases. In this study, we proposed a compact rotating multibarreled design for capsule robots that enables selective operation for either multiple biopsies or on-demand drug delivery. Each barrel can accommodate either a biopsy needle or a drug, providing flexibility to tailor the functions of the capsule robot to specific clinical needs. A motorized lead screw mechanism was employed to initiate the operations for tissue biopsy or drug release, while the transition between biopsy and drug delivery modes is facilitated by the motorized rotation of a cylinder that houses all the barrels. A robotic arm equipped with a permanent magnet as its end effector was used to achieve various motion controls for the capsule robot, including sliding, rolling, rotating, and pitching in different directions. Ex vivo experiments conducted in a porcine stomach demonstrated the successful sampling of human gastric tumors at three specific lesions, yielding an average sample volume of approximately 0.6 mm$^{3}$. Furthermore, we confirmed that the biopsy can penetrate the mucosal and submucosal layers of gastric tissue, allowing for tissue collection deep within the muscular layer. Additionally, the robot exhibited precise drug delivery capabilities, accurately administering multiple types of drugs to various lesions, achieving an average delivery rate of approximately 75% of the barrel's full capacity. The multifunctional and versatile design of the capsule robot presents great potential for advanced and tailored treatments in gastroenterology.
- 5 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
Enhanced Localization Strategy for Magnetic Capsule Robot Using On-Board Nine-Axis IMU Through Incorporation of Alternating Magnetic Field
Capsule robots have gained increasing prominence in gastroscopy for their diagnostic capabilities and noninvasive accessibility to narrow passages with reduced risks. Magnetic positioning plays a crucial role in mapping the trajectory of the capsule robot and targeting specific areas of interest. However, the current magnetic positioning technology is limited by challenges of incompatibility with external magnetic manipulation systems, power and size constraints, and reduced resolution caused by accumulated errors during attitude estimation. Here, we propose an enhanced localization strategy for magnetic capsule robots with an on-board nine-axis inertial measurement unit (IMU) through the incorporation of an alternating magnetic field. Motion control of the capsule robot is achieved by an extracorporeal robotically manipulated permanent magnet, which also serves as a magnetic reference for determining the capsule robot’s relative position. An alternating magnetic field is applied using a single-axis Helmholtz coil to compensate for the accumulated error in the yaw angle of the IMU. A digital lock-in amplifier algorithm is employed to decouple the static magnetic field generated by the permanent magnet from the alternating magnetic fields. To improve the accuracy of attitude and position estimation, we introduce an improved magnetic dipole model, which is optimized through high-resolution spatial mapping of the magnetic field of the permanent magnet. Experimental results demonstrate that within a rectangular space of $100\times $ 100 mm, our proposed strategy achieves an average position error of 2.52 mm and an average angle error of 1.53°, meeting the accuracy requirements for clinical examinations.
- 5 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
Enhanced Localization Strategy for Magnetic Capsule Robot Using On-Board Nine-Axis IMU Through Incorporation of Alternating Magnetic Field
Capsule robots have gained increasing prominence in gastroscopy for their diagnostic capabilities and noninvasive accessibility to narrow passages with reduced risks. Magnetic positioning plays a crucial role in mapping the trajectory of the capsule robot and targeting specific areas of interest. However, the current magnetic positioning technology is limited by challenges of incompatibility with external magnetic manipulation systems, power and size constraints, and reduced resolution caused by accumulated errors during attitude estimation. Here, we propose an enhanced localization strategy for magnetic capsule robots with an on-board nine-axis inertial measurement unit (IMU) through the incorporation of an alternating magnetic field. Motion control of the capsule robot is achieved by an extracorporeal robotically manipulated permanent magnet, which also serves as a magnetic reference for determining the capsule robot’s relative position. An alternating magnetic field is applied using a single-axis Helmholtz coil to compensate for the accumulated error in the yaw angle of the IMU. A digital lock-in amplifier algorithm is employed to decouple the static magnetic field generated by the permanent magnet from the alternating magnetic fields. To improve the accuracy of attitude and position estimation, we introduce an improved magnetic dipole model, which is optimized through high-resolution spatial mapping of the magnetic field of the permanent magnet. Experimental results demonstrate that within a rectangular space of $100\times $ 100 mm, our proposed strategy achieves an average position error of 2.52 mm and an average angle error of 1.53°, meeting the accuracy requirements for clinical examinations.
- Open Access
- 17 December 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (12) , 1572
Development of Cell-Carrying Magnetic Microrobots with Bioactive Nanostructured Titanate Surface for Enhanced Cell Adhesion
Cell-carrying magnet-driven microrobots are easily affected by blood flow or body fluids during transportation in the body, and thus cells often fall off from the microrobots. To reduce the loss of loaded cells, we developed a microrobot with a bioactive nanostructured titanate surface (NTS), which enhances cell adhesion. The microrobot was fabricated using 3D laser lithography and coated with nickel for magnetic actuation. Then, the microrobot was coated with titanium for the external generation of an NTS through reactions in NaOH solution. Enhanced cell adhesion may be attributed to the changes in the surface wettability of the microrobot and in the morphology of the loaded cells. An experiment was performed on a microfluidic chip for the simulation of blood flow environment, and result revealed that the cells adhered closely to the microrobot with NTS and were not obviously affected by flow. The cell viability and protein absorption test and alkaline phosphatase activity assay indicated that NTS can provide a regulatory means for improving cell proliferation and early osteogenic differentiation. This research provided a novel microrobotic platform that can positively influence the behaviour of cells loaded on microrobots through surface nanotopography, thereby opening up a new route for microrobot cell delivery.
- 17 December 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (12) , 1572
Open AccessDevelopment of Cell-Carrying Magnetic Microrobots with Bioactive Nanostructured Titanate Surface for Enhanced Cell Adhesion
Cell-carrying magnet-driven microrobots are easily affected by blood flow or body fluids during transportation in the body, and thus cells often fall off from the microrobots. To reduce the loss of loaded cells, we developed a microrobot with a bioactive nanostructured titanate surface (NTS), which enhances cell adhesion. The microrobot was fabricated using 3D laser lithography and coated with nickel for magnetic actuation. Then, the microrobot was coated with titanium for the external generation of an NTS through reactions in NaOH solution. Enhanced cell adhesion may be attributed to the changes in the surface wettability of the microrobot and in the morphology of the loaded cells. An experiment was performed on a microfluidic chip for the simulation of blood flow environment, and result revealed that the cells adhered closely to the microrobot with NTS and were not obviously affected by flow. The cell viability and protein absorption test and alkaline phosphatase activity assay indicated that NTS can provide a regulatory means for improving cell proliferation and early osteogenic differentiation. This research provided a novel microrobotic platform that can positively influence the behaviour of cells loaded on microrobots through surface nanotopography, thereby opening up a new route for microrobot cell delivery.
- 27 April 2020
- Published by IOP Publishing in Biofabrication
- Vol. 12 (3) , 035005
Gravitational sedimentation-based approach for ultra-simple and flexible cell patterning coculture on microfluidic device
Combining patterning coculture technique with microfluidics enables the reconstruction of complex in-vivo system to facilitate in-vitro studies on cell-cell and cell-environment interactions. However, simple and versatile approaches for patterning coculture of cells on microfluidic platforms remain lacking. In this study, a novel gravitational sedimentation-based approach is presented to achieve ultra-simple and flexible cell patterning coculture on a microfluidic platform, where multiple cell types can be patterned simultaneously to form a well-organized cell coculture. In contrast to other approaches, the proposed approach allows the rapid patterning of multiple cell types in microfluidic channels without the use of sheath flow and a prepatterned functional surface. This feature greatly simplifies the experimental setup, operation, and chip fabrication. Moreover, cell patterning can be adjusted by simply modifying the cell-loading tubing direction, thereby enabling great flexibility for the construction of different cell patterns without complicating the chip design and flow control. A series of physical and biological experiments are conducted to validate the proposed approach. This research paves a new way for building physiologically realistic in-vitro coculture models on microfluidic platforms for various applications, such as cell-cell interaction and drug screening.
- 27 April 2020
- Published by IOP Publishing in Biofabrication
- Vol. 12 (3) , 035005
Gravitational sedimentation-based approach for ultra-simple and flexible cell patterning coculture on microfluidic device
Combining patterning coculture technique with microfluidics enables the reconstruction of complex in-vivo system to facilitate in-vitro studies on cell-cell and cell-environment interactions. However, simple and versatile approaches for patterning coculture of cells on microfluidic platforms remain lacking. In this study, a novel gravitational sedimentation-based approach is presented to achieve ultra-simple and flexible cell patterning coculture on a microfluidic platform, where multiple cell types can be patterned simultaneously to form a well-organized cell coculture. In contrast to other approaches, the proposed approach allows the rapid patterning of multiple cell types in microfluidic channels without the use of sheath flow and a prepatterned functional surface. This feature greatly simplifies the experimental setup, operation, and chip fabrication. Moreover, cell patterning can be adjusted by simply modifying the cell-loading tubing direction, thereby enabling great flexibility for the construction of different cell patterns without complicating the chip design and flow control. A series of physical and biological experiments are conducted to validate the proposed approach. This research paves a new way for building physiologically realistic in-vitro coculture models on microfluidic platforms for various applications, such as cell-cell interaction and drug screening.
- Open Access
- 13 April 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (4) , 404
Magnetically Powered Biodegradable Microswimmers
The propulsive efficiency and biodegradability of wireless microrobots play a significant role in facilitating promising biomedical applications. Mimicking biological matters is a promising way to improve the performance of microrobots. Among diverse locomotion strategies, undulatory propulsion shows remarkable efficiency and agility. This work proposes a novel magnetically powered and hydrogel-based biodegradable microswimmer. The microswimmer is fabricated integrally by 3D laser lithography based on two-photon polymerization from a biodegradable material and has a total length of 200 μm and a diameter of 8 μm. The designed microswimmer incorporates a novel design utilizing four rigid segments, each of which is connected to the succeeding segment by spring to achieve undulation, improving structural integrity as well as simplifying the fabrication process. Under an external oscillating magnetic field, the microswimmer with multiple rigid segments connected by flexible spring can achieve undulatory locomotion and move forward along with the directions guided by the external magnetic field in the low Reynolds number (Re) regime. In addition, experiments demonstrated that the microswimmer can be degraded successfully, which allows it to be safely applied in real-time in vivo environments. This design has great potential in future in vivo applications such as precision medicine, drug delivery, and diagnosis.
- 13 April 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (4) , 404
Open AccessMagnetically Powered Biodegradable Microswimmers
The propulsive efficiency and biodegradability of wireless microrobots play a significant role in facilitating promising biomedical applications. Mimicking biological matters is a promising way to improve the performance of microrobots. Among diverse locomotion strategies, undulatory propulsion shows remarkable efficiency and agility. This work proposes a novel magnetically powered and hydrogel-based biodegradable microswimmer. The microswimmer is fabricated integrally by 3D laser lithography based on two-photon polymerization from a biodegradable material and has a total length of 200 μm and a diameter of 8 μm. The designed microswimmer incorporates a novel design utilizing four rigid segments, each of which is connected to the succeeding segment by spring to achieve undulation, improving structural integrity as well as simplifying the fabrication process. Under an external oscillating magnetic field, the microswimmer with multiple rigid segments connected by flexible spring can achieve undulatory locomotion and move forward along with the directions guided by the external magnetic field in the low Reynolds number (Re) regime. In addition, experiments demonstrated that the microswimmer can be degraded successfully, which allows it to be safely applied in real-time in vivo environments. This design has great potential in future in vivo applications such as precision medicine, drug delivery, and diagnosis.
- 18 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (8) , 2349-2358
Automated In Vivo Navigation of Magnetic-Driven Microrobots Using OCT Imaging Feedback
Objective: The application of in vivo microrobot navigation has received considerable attention from the field of precision therapy, which uses microrobots in living organisms. Methods: This study investigates the navigation of microrobots in vivo using optical coherence tomography (OCT) imaging feedback. The electromagnetic gradient field generated by a home-made electromagnetic manipulation system is magnetically modeled. With this model, the magnetic force acting on the microrobot is calculated, and the relationship between this force and the velocity of the microrobot is characterized. Results: Results are verified through in vitro experiments wherein microrobots are driven in three types of fluid, namely, normal saline, gastric juice, and mouse urine. In vivo experiments are performed to navigate the microrobot in a mouse portal vein in which the OCT imaging system tracks the microrobot in vivo. Conclusions: Experimental results demonstrate the effectiveness of the proposed approach. The microrobots can be magnetically driven in the in vivo environment using the OCT imaging feedback. Significance: The significance of this study lies in providing a new method of driving microrobots in vivo.
- 18 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (8) , 2349-2358
Automated In Vivo Navigation of Magnetic-Driven Microrobots Using OCT Imaging Feedback
Objective: The application of in vivo microrobot navigation has received considerable attention from the field of precision therapy, which uses microrobots in living organisms. Methods: This study investigates the navigation of microrobots in vivo using optical coherence tomography (OCT) imaging feedback. The electromagnetic gradient field generated by a home-made electromagnetic manipulation system is magnetically modeled. With this model, the magnetic force acting on the microrobot is calculated, and the relationship between this force and the velocity of the microrobot is characterized. Results: Results are verified through in vitro experiments wherein microrobots are driven in three types of fluid, namely, normal saline, gastric juice, and mouse urine. In vivo experiments are performed to navigate the microrobot in a mouse portal vein in which the OCT imaging system tracks the microrobot in vivo. Conclusions: Experimental results demonstrate the effectiveness of the proposed approach. The microrobots can be magnetically driven in the in vivo environment using the OCT imaging feedback. Significance: The significance of this study lies in providing a new method of driving microrobots in vivo.
- 10 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanobioscience
- Vol. 19 (2) , 192-202
Precise Drug Delivery by Using PLGA-Based Microspheres and Optical Manipulators
The accurate delivery of precise amounts of drugs to a specific location can considerably affect various clinical applications. The precise control of drug amount and position is crucial to a successful drug delivery. This paper proposes the use of poly(lactide-co-glycolicacid) (PLGA)-based microspheres to contain precise amounts of drugs and an optical tweezer manipulator to transport these drug-containing microspheres to their targeted sites in vivo. The drugs were delivered by the PLGA-based microspheres to the yolk sac of zebrafish embryos, and a sustained drug release was observed to examine the anti-angiogenesis and angiogenesis activities. The PLGA-based microspheres degraded in zebrafish, thereby verifying that these microspheres can be used as drug carriers in vivo to ensure good biocompatibility and biodegradation. The proposed precise drug delivery approach can be used in protein tests and drug property characterization in vivo.
- 10 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanobioscience
- Vol. 19 (2) , 192-202
Precise Drug Delivery by Using PLGA-Based Microspheres and Optical Manipulators
The accurate delivery of precise amounts of drugs to a specific location can considerably affect various clinical applications. The precise control of drug amount and position is crucial to a successful drug delivery. This paper proposes the use of poly(lactide-co-glycolicacid) (PLGA)-based microspheres to contain precise amounts of drugs and an optical tweezer manipulator to transport these drug-containing microspheres to their targeted sites in vivo. The drugs were delivered by the PLGA-based microspheres to the yolk sac of zebrafish embryos, and a sustained drug release was observed to examine the anti-angiogenesis and angiogenesis activities. The PLGA-based microspheres degraded in zebrafish, thereby verifying that these microspheres can be used as drug carriers in vivo to ensure good biocompatibility and biodegradation. The proposed precise drug delivery approach can be used in protein tests and drug property characterization in vivo.
- Open Access
- 19 July 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (14) , 2883
Automated Indirect Transportation of Biological Cells with Optical Tweezers and a 3D Printed Microtool
Optical tweezers are widely used for noninvasive and precise micromanipulation of living cells to understand biological processes. By focusing laser beams on cells, direct cell manipulation with optical tweezers can achieve high precision and flexibility. However, direct exposure to the laser beam can lead to negative effects on the cells. These phenomena are also known as photobleaching and photodamage. In this study, we proposed a new indirect cell micromanipulation approach combined with a robot-aided holographic optical tweezer system and 3D nano-printed microtool. The microtool was designed with a V-shaped head and an optical handle part. The V-shaped head can push and trap different sizes of cells as the microtool moves forward by optical trapping of the handle part. In this way, cell exposure to the laser beam can be effectively reduced. The microtool was fabricated with a laser direct writing system by two-photon photopolymerization. A control strategy combined with an imaging processing algorithm was introduced for automated manipulation of the microtool and cells. Experiments were performed to verify the effectiveness of our approach. First, automated microtool transportation and rotation were demonstrated with high precision. Second, indirect optical transportations of cells, with and without an obstacle, were performed to demonstrate the effectiveness of the proposed approach. Third, experiments of fluorescent cell manipulation were performed to confirm that, indicated by the photobleaching effect, indirect manipulation with the microtool could induce less laser exposure compared with direct optical manipulation. The proposed method could be useful in complex biomedical applications where precise cell manipulation and less laser exposure are required.
- 19 July 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (14) , 2883
Open AccessAutomated Indirect Transportation of Biological Cells with Optical Tweezers and a 3D Printed Microtool
Optical tweezers are widely used for noninvasive and precise micromanipulation of living cells to understand biological processes. By focusing laser beams on cells, direct cell manipulation with optical tweezers can achieve high precision and flexibility. However, direct exposure to the laser beam can lead to negative effects on the cells. These phenomena are also known as photobleaching and photodamage. In this study, we proposed a new indirect cell micromanipulation approach combined with a robot-aided holographic optical tweezer system and 3D nano-printed microtool. The microtool was designed with a V-shaped head and an optical handle part. The V-shaped head can push and trap different sizes of cells as the microtool moves forward by optical trapping of the handle part. In this way, cell exposure to the laser beam can be effectively reduced. The microtool was fabricated with a laser direct writing system by two-photon photopolymerization. A control strategy combined with an imaging processing algorithm was introduced for automated manipulation of the microtool and cells. Experiments were performed to verify the effectiveness of our approach. First, automated microtool transportation and rotation were demonstrated with high precision. Second, indirect optical transportations of cells, with and without an obstacle, were performed to demonstrate the effectiveness of the proposed approach. Third, experiments of fluorescent cell manipulation were performed to confirm that, indicated by the photobleaching effect, indirect manipulation with the microtool could induce less laser exposure compared with direct optical manipulation. The proposed method could be useful in complex biomedical applications where precise cell manipulation and less laser exposure are required.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1641-1645
Indirect Transportation of Filamentous Cells by Using Optically Actuated Microtools
Scientists have been able to trap and move biological cells by using optical tweezers through the momentum of a focused laser beam. However, in conventional direct cell manipulation involving optical tweezers, cells must be exposed to the photon flux and consequently become damaged during the process. The indirect optical manipulation of cells has attracted many concerns, but the manipulation of filamentous cells remains poorly addressed. In this study, we propose an approach for the indiret optical transportation of filamentous cells. A microtool is designed and fabricated through two-photon polymerization. Filamentous cells are then transported by cooperatively manipulating two microtools with multiple optical traps. Experiments are performed on filamentous cyanobacterial cells to demonstrate the effectiveness of the proposed approach.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1641-1645
Indirect Transportation of Filamentous Cells by Using Optically Actuated Microtools
Scientists have been able to trap and move biological cells by using optical tweezers through the momentum of a focused laser beam. However, in conventional direct cell manipulation involving optical tweezers, cells must be exposed to the photon flux and consequently become damaged during the process. The indirect optical manipulation of cells has attracted many concerns, but the manipulation of filamentous cells remains poorly addressed. In this study, we propose an approach for the indiret optical transportation of filamentous cells. A microtool is designed and fabricated through two-photon polymerization. Filamentous cells are then transported by cooperatively manipulating two microtools with multiple optical traps. Experiments are performed on filamentous cyanobacterial cells to demonstrate the effectiveness of the proposed approach.
- 28 May 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (12) , 16475-16482
Translational and rotational manipulation of filamentous cells using optically driven microrobots
Optical cell manipulation has become increasingly valuable in cell-based assays. In this paper, we demonstrate the translational and rotational manipulation of filamentous cells using multiple cooperative microrobots automatically driven by holographic optical tweezers. The photodamage of the cells due to direct irradiation of the laser beam can be effectively avoided. The proposed method will enable fruitful biomedical applications where precise cell manipulation and less photodamage are required.
- 28 May 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (12) , 16475-16482
Translational and rotational manipulation of filamentous cells using optically driven microrobots
Optical cell manipulation has become increasingly valuable in cell-based assays. In this paper, we demonstrate the translational and rotational manipulation of filamentous cells using multiple cooperative microrobots automatically driven by holographic optical tweezers. The photodamage of the cells due to direct irradiation of the laser beam can be effectively avoided. The proposed method will enable fruitful biomedical applications where precise cell manipulation and less photodamage are required.