Arun K. Singhal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Arun K. Singhal has a total of 123 co-authors. Here are the top co-authors by number of shared publications:
Carol A. Fisher
Division of Cardiac and Thoracic Surgery, Department of Surgery, Temple University School of Medicine, Philadelphia, PA
5 shared publications- Josef Stehlik
University of Utah School of Medicine, Salt Lake City, Utah, USA
5 shared publications Mahender Macha
5 shared publicationsSatoshi Furukawa
5 shared publicationsValentino Piacentino
4 shared publicationsBruce I. Goldman
3 shared publications
Latest Publications
- Open Access
- 13 October 2026
- Published by Springer Nature in Journal of Cardiovascular Imaging
- Vol. 34 (1) , 39
Radiographic phenotyping of healthy and diseased aortas
Background: Ascending aortic diameter guides intervention for thoracic aneurysms. Many patients with acute type A aortic dissection (ATAAD) present with ascending aortic diameters below 5.5 cm, rendering diameter an insufficient risk discriminator. This study evaluated computed tomography angiography (CTA) morphology to identify predissection radiographic features associated with ATAAD. Methods: Control ( n = 50, CTA for non-aortic indications), aneurysm ( n = 61, thoracic ascending aorta [TAA] ≥ 4.5 cm), and predissection ( n = 13, CTA within 3 years before dissection) groups were studied. Scans were interpreted by thoracic radiologists using predefined measurements. Results: Age and sex distribution differed overall among groups ( P < 0.001 and P = 0.010, respectively). The aneurysm group was older than controls, but the age difference from the predissection group was not significant ( P = 0.084). Maximum TAA diameter (MaxD) was 3.11 ± 0.30, 4.96 ± 0.52, and 3.89 ± 0.60 cm in control, aneurysm, and predissection groups respectively; all predissection MaxD values were below 5.5 cm (maximum, 4.9 cm). Ascending aortic length (AAL) was elevated in both disease groups (aneurysm group, 9.03 ± 1.08 cm; predissection group, 10.73 ± 1.41 cm; P < 0.001 vs. control group, 6.38 ± 0.75 cm). The AAL/MaxD ratio differed significantly between every pair of groups (control group, 2.06 ± 0.22; aneurysm group, 1.83 ± 0.21; predissection group, 2.80 ± 0.50; all pairwise P < 0.001), reflecting disproportionate elongation in predissection aortas. Aneurysm patients demonstrated diffuse thoracic dilation, whereas predissection group patients showed predominantly ascending aortic involvement. Conclusions: In a small exploratory study, predissection aortas displayed a distinct morphological phenotype characterized by disproportionate elongation, moderate dilation, and a relatively nondilated descending aorta—distinct from the diffuse dilation of aneurysm. Ascending aortic length and the AAL/MaxD ratio may provide complementary morphological information beyond maximal diameter alone.
- 13 October 2026
- Published by Springer Nature in Journal of Cardiovascular Imaging
- Vol. 34 (1) , 39
Open AccessRadiographic phenotyping of healthy and diseased aortas
Background: Ascending aortic diameter guides intervention for thoracic aneurysms. Many patients with acute type A aortic dissection (ATAAD) present with ascending aortic diameters below 5.5 cm, rendering diameter an insufficient risk discriminator. This study evaluated computed tomography angiography (CTA) morphology to identify predissection radiographic features associated with ATAAD. Methods: Control ( n = 50, CTA for non-aortic indications), aneurysm ( n = 61, thoracic ascending aorta [TAA] ≥ 4.5 cm), and predissection ( n = 13, CTA within 3 years before dissection) groups were studied. Scans were interpreted by thoracic radiologists using predefined measurements. Results: Age and sex distribution differed overall among groups ( P < 0.001 and P = 0.010, respectively). The aneurysm group was older than controls, but the age difference from the predissection group was not significant ( P = 0.084). Maximum TAA diameter (MaxD) was 3.11 ± 0.30, 4.96 ± 0.52, and 3.89 ± 0.60 cm in control, aneurysm, and predissection groups respectively; all predissection MaxD values were below 5.5 cm (maximum, 4.9 cm). Ascending aortic length (AAL) was elevated in both disease groups (aneurysm group, 9.03 ± 1.08 cm; predissection group, 10.73 ± 1.41 cm; P < 0.001 vs. control group, 6.38 ± 0.75 cm). The AAL/MaxD ratio differed significantly between every pair of groups (control group, 2.06 ± 0.22; aneurysm group, 1.83 ± 0.21; predissection group, 2.80 ± 0.50; all pairwise P < 0.001), reflecting disproportionate elongation in predissection aortas. Aneurysm patients demonstrated diffuse thoracic dilation, whereas predissection group patients showed predominantly ascending aortic involvement. Conclusions: In a small exploratory study, predissection aortas displayed a distinct morphological phenotype characterized by disproportionate elongation, moderate dilation, and a relatively nondilated descending aorta—distinct from the diffuse dilation of aneurysm. Ascending aortic length and the AAL/MaxD ratio may provide complementary morphological information beyond maximal diameter alone.
- 27 September 2023
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 69 (10) , e449
Simple, Swift, and Safe for Managing Post Infarction Ventricular Septal Defects
- 27 September 2023
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 69 (10) , e449
Simple, Swift, and Safe for Managing Post Infarction Ventricular Septal Defects
- 27 December 2022
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 69 (6) , e278-e283
Impella Support for Surgical Ventricular Septal Defect Repair
Acute postinfarct ventricular septal defect (VSD) is associated with high mortality due to a combination of cardiogenic shock and a complex repair in recently infarcted fragile myocardium.1 Although the Impella heart pump is established as support for cardiogenic shock, it is relatively contraindicated in postinfarct VSD because of potential right-to-left shunt or stroke due to VSD tissue–related embolus. On autopsy, early repair is technically difficult due to tissue friability and as a result, 38% of surgically repaired patients have evidence of recurrent interventricular septal rupture.2 Delayed surgical repair (>7 days) is associated with superior survival—54% after 7 days versus 18% prior—but hemodynamic instability may prevent delay.3 Case reports have shown successful early left ventricular unloading with Impella patients with acute postinfarct VSD before surgical repair.4,5 We discuss our algorithm for pre-repair Impella support in which we stratify pre-repair support based on the Qp/Qs ratio. For VSD with Qp/Qs >2.5, we use a preoperative Impella heart pump and have not demonstrated reversal in the left-to-right shunt on echocardiography and/or stroke. Our findings are consistent with theoretical models of unloading as demonstrated by shifts in pressure–volume loops.6
- 27 December 2022
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 69 (6) , e278-e283
Impella Support for Surgical Ventricular Septal Defect Repair
Acute postinfarct ventricular septal defect (VSD) is associated with high mortality due to a combination of cardiogenic shock and a complex repair in recently infarcted fragile myocardium.1 Although the Impella heart pump is established as support for cardiogenic shock, it is relatively contraindicated in postinfarct VSD because of potential right-to-left shunt or stroke due to VSD tissue–related embolus. On autopsy, early repair is technically difficult due to tissue friability and as a result, 38% of surgically repaired patients have evidence of recurrent interventricular septal rupture.2 Delayed surgical repair (>7 days) is associated with superior survival—54% after 7 days versus 18% prior—but hemodynamic instability may prevent delay.3 Case reports have shown successful early left ventricular unloading with Impella patients with acute postinfarct VSD before surgical repair.4,5 We discuss our algorithm for pre-repair Impella support in which we stratify pre-repair support based on the Qp/Qs ratio. For VSD with Qp/Qs >2.5, we use a preoperative Impella heart pump and have not demonstrated reversal in the left-to-right shunt on echocardiography and/or stroke. Our findings are consistent with theoretical models of unloading as demonstrated by shifts in pressure–volume loops.6
- Open Access
- 26 April 2022
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 37 (7) , 2086-2089
Concomitant aortic valve repair for aortic insufficiency and implantation of left ventricle mechanical support
Background Moderate to severe aortic valve insufficiency (AI) in patients undergoing left ventricular assist device (LVAD) implantation is a significant complication which occurs in up to 10.7% of patients in the INTERMACS database and has profound consequences for survival. Preoperative Impella use is associaed with greater post-LVAD AI. Case Presentation 56 y/o Caucasian female with acute exacerbation of chronic congestive heart failure who needed urgent Impella placement followed by elective Heartmate III LVAD. Conclusion Patients who have aortic valve regurgitation at the time of implantation have been handled by several methods, including aortic valve leaflets approximation, to aortic valve replacement or even valve closure. We report a case of geometric ring annuloplasty for repair of a regurgitant aortic valve during destination LVAD implantation.
- 26 April 2022
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 37 (7) , 2086-2089
Open AccessConcomitant aortic valve repair for aortic insufficiency and implantation of left ventricle mechanical support
Background Moderate to severe aortic valve insufficiency (AI) in patients undergoing left ventricular assist device (LVAD) implantation is a significant complication which occurs in up to 10.7% of patients in the INTERMACS database and has profound consequences for survival. Preoperative Impella use is associaed with greater post-LVAD AI. Case Presentation 56 y/o Caucasian female with acute exacerbation of chronic congestive heart failure who needed urgent Impella placement followed by elective Heartmate III LVAD. Conclusion Patients who have aortic valve regurgitation at the time of implantation have been handled by several methods, including aortic valve leaflets approximation, to aortic valve replacement or even valve closure. We report a case of geometric ring annuloplasty for repair of a regurgitant aortic valve during destination LVAD implantation.
- Open Access
- 6 January 2022
- Published by Wiley
Concomitant Repair For Mild Aortic Insufficiency And Implantation Of Left Ventricle Mechanical Support
Aortic valve regurgitation in patients undergoing LVAD implantation is a significant complication which occurs in up to 10% of patients in the INTERMACS database. Patients who have aortic valve regurgitation at the time of implant have been handled by several methods, including aortic valve leaflets approximation, to aortic valve replacement or even valve closure. We report a case where we used HAART Ring to repair a regurgitant aortic valve during LAVD implant for destination therapy.
- 6 January 2022
- Published by Wiley
Open AccessConcomitant Repair For Mild Aortic Insufficiency And Implantation Of Left Ventricle Mechanical Support
Aortic valve regurgitation in patients undergoing LVAD implantation is a significant complication which occurs in up to 10% of patients in the INTERMACS database. Patients who have aortic valve regurgitation at the time of implant have been handled by several methods, including aortic valve leaflets approximation, to aortic valve replacement or even valve closure. We report a case where we used HAART Ring to repair a regurgitant aortic valve during LAVD implant for destination therapy.
- 1 October 2010
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 29 (10) , 1198-1200
Prolonged allograft ischemic time is not associated with higher incidence of antibody-mediated rejection
- 1 October 2010
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 29 (10) , 1198-1200
Prolonged allograft ischemic time is not associated with higher incidence of antibody-mediated rejection
- 1 March 2010
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 29 (3) , 235-239
Effects of the 2006 U.S. thoracic organ allocation change: Analysis of local impact on organ procurement and heart transplantation
- 1 March 2010
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 29 (3) , 235-239
Effects of the 2006 U.S. thoracic organ allocation change: Analysis of local impact on organ procurement and heart transplantation
- 1 November 2009
- Published by Elsevier in Transplantation Proceedings
- Vol. 41 (9) , 3539-3544
Impact of Donor Cause of Death on Transplant Outcomes: UNOS Registry Analysis
- 1 November 2009
- Published by Elsevier in Transplantation Proceedings
- Vol. 41 (9) , 3539-3544
Impact of Donor Cause of Death on Transplant Outcomes: UNOS Registry Analysis