Elsi Violeta Mejia-Uriarte
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Elsi Violeta Mejia-Uriarte has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
M. Navarrete
Instituto de Ingeniería, Universidad Nacional Autónoma de México, UNAM, C.U., Distrito Federal 04510, Mexico
10 shared publicationsM. Villagrán-Muniz
CCADET, Universidad Nacional Autónoma de México, Mexico City, Mexico
8 shared publicationsE. Camarillo
5 shared publicationsN. Qureshi
Instituto de Ciencias Aplicadas y Tecnología, Universidad Nacional Autónoma de México, CU 04510, Cd. México, Mexico
5 shared publicationsH. Murrieta S
Instituto de Física, AP 20-364, C.P. 01000, Universidad Nacional Autónoma de México, D. F. Mexico, Mexico
4 shared publicationsO. Kolokoltsev
4 shared publications
Latest Publications
- Open Access
- 31 August 2026
- Published by Universidad Nacional Autonoma de Mexico in Journal of Applied Research and Technology
- Vol. 24 (4) , 619-631
Simultaneous Double Emission of Blue-Cyan Light from Europium Nanostructures in a Solid Host
A sample of potassium bromide, doped with divalent europium ions, was stored at 200 °C for approximately six months and exhibited two emission bands at room temperature: blue and cyan. These emissions are associated with two types of nanostructures (NS) that form during annealing. The localized emission spectra were obtained in a scanning zone (SZ) 46 x 162 μm2 from a selected sample of 900 x 320 μm(2) and 90 μm in thickness using an experimental light-scanning design implemented in our laboratory. While scanning the crystal, several changes in the peak position and intensity of the emission spectra were observed. These changes corresponded to the stable dihalide phase (SDP) and the metastable dihalide phase (MDP). In certain regions, the intensity of the cyan emission band was slightly more significant than that of the blue emission band. The concurrent observation of these two emission bands confirms the coexistence of both phases within the single crystal.
- 31 August 2026
- Published by Universidad Nacional Autonoma de Mexico in Journal of Applied Research and Technology
- Vol. 24 (4) , 619-631
Open AccessSimultaneous Double Emission of Blue-Cyan Light from Europium Nanostructures in a Solid Host
A sample of potassium bromide, doped with divalent europium ions, was stored at 200 °C for approximately six months and exhibited two emission bands at room temperature: blue and cyan. These emissions are associated with two types of nanostructures (NS) that form during annealing. The localized emission spectra were obtained in a scanning zone (SZ) 46 x 162 μm2 from a selected sample of 900 x 320 μm(2) and 90 μm in thickness using an experimental light-scanning design implemented in our laboratory. While scanning the crystal, several changes in the peak position and intensity of the emission spectra were observed. These changes corresponded to the stable dihalide phase (SDP) and the metastable dihalide phase (MDP). In certain regions, the intensity of the cyan emission band was slightly more significant than that of the blue emission band. The concurrent observation of these two emission bands confirms the coexistence of both phases within the single crystal.
- Open Access
- 27 December 2025
- Published by Universidad Nacional Autonoma de Mexico in Journal of Applied Research and Technology
- Vol. 23 (6) , 638-650
TDOCT with Optical Delay Line based on Static Helicoid Mirror
In this work, we described a design of Optical Delay Line (ODL) for Time Domain Optical Coherence Tomography (TDOCT). ODL is based on a static helicoid mirror, integrated with an optical deflector. The delay line can provide up to 10 mm scanning depth range, thanks to its multi-pass configuration. The TDOCT system has been analyzed and optimized to operate in ultrahigh depth resolution regime. The estimated sensitivity of the TDOCT, at the presence of the relatively high level of the photon excess noise, can be of the order of -94 dB.
- 27 December 2025
- Published by Universidad Nacional Autonoma de Mexico in Journal of Applied Research and Technology
- Vol. 23 (6) , 638-650
Open AccessTDOCT with Optical Delay Line based on Static Helicoid Mirror
In this work, we described a design of Optical Delay Line (ODL) for Time Domain Optical Coherence Tomography (TDOCT). ODL is based on a static helicoid mirror, integrated with an optical deflector. The delay line can provide up to 10 mm scanning depth range, thanks to its multi-pass configuration. The TDOCT system has been analyzed and optimized to operate in ultrahigh depth resolution regime. The estimated sensitivity of the TDOCT, at the presence of the relatively high level of the photon excess noise, can be of the order of -94 dB.
- Open Access
- 21 February 2023
- Published by Universidad Nacional Autonoma de Mexico in Mundo Nano. Revista Interdisciplinaria en Nanociencias y Nanotecnología
- Vol. 17 (32) , 1e-20e
Efecto de la temperatura en la formación de nanoestructuras luminiscentes en el KBr:Eu2+
Se presenta el estudio del efecto de la temperatura en la formación de nanoestructuras luminiscentes (NsL) en el monocristal de KBr:Eu2+. Las muestras se almacenaron durante 16 semanas a 100 y 200 °C para formar la fase de Suzuki (FS) y fase dihaluro (FD), respectivamente, la concentración de impurezas en ambos casos fue ~380 ppm. La formación de nanoestructuras fue estudiada por espectroscopía óptica (EO) y las imágenes fueron obtenidas por microscopía de fuerza atómica (AFM). Los espectros de absorción y emisión reportan cambios importantes en 10 Dq para la FS a 11365.2 cm–1, con pico de misión a 433 nm y para la FD 10 Dq a 5319.3 cm–1 con dos picos de emisión a 428.5 y 450.7 nm, característicos de la fase dihaluro. Las imágenes observadas por AFM muestran que las NsL para la FS van desde 40 a 435 nm de diámetro con alturas de 2 a 120 nm, en contraste con la FD donde hay dispersión de tamaños es desde 20 nm hasta de 500 nm de diámetro, pero con alturas limitadas en el intervalo de 1 a 7 nm. Estos resultados comprueban suposiciones teóricas que, efectivamente, la FD es de tipo laminar, los resultados obtenidos están de acuerdo con la literatura reportada.
- 21 February 2023
- Published by Universidad Nacional Autonoma de Mexico in Mundo Nano. Revista Interdisciplinaria en Nanociencias y Nanotecnología
- Vol. 17 (32) , 1e-20e
Open AccessEfecto de la temperatura en la formación de nanoestructuras luminiscentes en el KBr:Eu2+
Se presenta el estudio del efecto de la temperatura en la formación de nanoestructuras luminiscentes (NsL) en el monocristal de KBr:Eu2+. Las muestras se almacenaron durante 16 semanas a 100 y 200 °C para formar la fase de Suzuki (FS) y fase dihaluro (FD), respectivamente, la concentración de impurezas en ambos casos fue ~380 ppm. La formación de nanoestructuras fue estudiada por espectroscopía óptica (EO) y las imágenes fueron obtenidas por microscopía de fuerza atómica (AFM). Los espectros de absorción y emisión reportan cambios importantes en 10 Dq para la FS a 11365.2 cm–1, con pico de misión a 433 nm y para la FD 10 Dq a 5319.3 cm–1 con dos picos de emisión a 428.5 y 450.7 nm, característicos de la fase dihaluro. Las imágenes observadas por AFM muestran que las NsL para la FS van desde 40 a 435 nm de diámetro con alturas de 2 a 120 nm, en contraste con la FD donde hay dispersión de tamaños es desde 20 nm hasta de 500 nm de diámetro, pero con alturas limitadas en el intervalo de 1 a 7 nm. Estos resultados comprueban suposiciones teóricas que, efectivamente, la FD es de tipo laminar, los resultados obtenidos están de acuerdo con la literatura reportada.
- Open Access
- 1 September 2022
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Journal of Ecological Engineering
- Vol. 23 (9) , 88-99
Functionalization of Gold Nanoparticles for the Detection of Heavy Metals in Contaminated Water Samples in the Province of Tayacaja
The work consisted in functionalizing gold nanoparticles to analytically detect heavy metals in contaminated water; in Tayacaja-Huancavelica-Peru, using physical method of laser ablation. The 450 mJ/p Nd:YAG was used as a pulsed laser generator for the production of colloids from AuNPs by the...
- 1 September 2022
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Journal of Ecological Engineering
- Vol. 23 (9) , 88-99
Open AccessFunctionalization of Gold Nanoparticles for the Detection of Heavy Metals in Contaminated Water Samples in the Province of Tayacaja
The work consisted in functionalizing gold nanoparticles to analytically detect heavy metals in contaminated water; in Tayacaja-Huancavelica-Peru, using physical method of laser ablation. The 450 mJ/p Nd:YAG was used as a pulsed laser generator for the production of colloids from AuNPs by the...
- 18 May 2018
- Published by Springer Nature in Journal of Cluster Science
- Vol. 29 (4) , 719-724
Synthesis of Silver Colloids with a Homemade Light Source
- 18 May 2018
- Published by Springer Nature in Journal of Cluster Science
- Vol. 29 (4) , 719-724
Synthesis of Silver Colloids with a Homemade Light Source
- 1 March 2017
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 240, 497-502
Magnonic sensor array based on magnetic nanoparticles to detect, discriminate and classify toxic gases
- 1 March 2017
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 240, 497-502
Magnonic sensor array based on magnetic nanoparticles to detect, discriminate and classify toxic gases
- 3 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 22 (3) , 222-227
Swept Source OCT Beyond the Coherence Length Limit
We present a simple modification to a swept source optical system that overcomes the limitations in the depth range associated with the short coherence length of fast swept lasers. It is based on a wavelength dependent delay induced by a diffraction grating pair with negative dispersion incorporated in a reference arm of a Mach-Zehnder optical coherence tomography interferometer. The experimental depth range in air obtained was as large as 1.6 cm for a source coherence length of 4 mm.
- 3 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 22 (3) , 222-227
Swept Source OCT Beyond the Coherence Length Limit
We present a simple modification to a swept source optical system that overcomes the limitations in the depth range associated with the short coherence length of fast swept lasers. It is based on a wavelength dependent delay induced by a diffraction grating pair with negative dispersion incorporated in a reference arm of a Mach-Zehnder optical coherence tomography interferometer. The experimental depth range in air obtained was as large as 1.6 cm for a source coherence length of 4 mm.
- Open Access
- 20 September 2015
- Published by Universidad Nacional Autonoma de Mexico in Mundo Nano. Revista Interdisciplinaria en Nanociencias y Nanotecnología
- Vol. 8 (14) , 81-91
Autorganización de nanoestructuras luminiscentes: sus formas y dimensiones
El autoensamble es el proceso por el cual los elementos participantes se agrupan en estructuras ordenadas y funcionales. Por las propiedades intrínsecas de los componentes y condiciones del medio, estas nuevas estructuras sólo pueden crecer hasta cierto tamaño, siendo del orden nanométrico, se conocen como nanoestructuras (NS), y, en consecuencia, pueden configurarse en diferentes formas geométricas bi y tridimensionales como: esferas, anillos, cubos, prismas, barras y otras formas más.Los halogenuros alcalinos son materiales que permiten la difusión de los iones en su estructura, por ello los utilizamos como matriz para la formación de NS luminiscentes, las cuales se han formado por la impurificación con impurezas divalentes como los iones de europio (Eu²+) o manganeso (Mn²+), por ejemplo. La forma y el tamaño de las NS influencian fuertemente en la longitud de onda de absorción, emisión y excitación. Siendo de este modo muy importante el estudio sobre el tipo de impureza y las condiciones en la que se autorganizan para formar diferentes NS, las cuales pueden ser utilizadas como sensores o emisores de luz para potenciales dispositivos en nanoptoelectrónica.
- 20 September 2015
- Published by Universidad Nacional Autonoma de Mexico in Mundo Nano. Revista Interdisciplinaria en Nanociencias y Nanotecnología
- Vol. 8 (14) , 81-91
Open AccessAutorganización de nanoestructuras luminiscentes: sus formas y dimensiones
El autoensamble es el proceso por el cual los elementos participantes se agrupan en estructuras ordenadas y funcionales. Por las propiedades intrínsecas de los componentes y condiciones del medio, estas nuevas estructuras sólo pueden crecer hasta cierto tamaño, siendo del orden nanométrico, se conocen como nanoestructuras (NS), y, en consecuencia, pueden configurarse en diferentes formas geométricas bi y tridimensionales como: esferas, anillos, cubos, prismas, barras y otras formas más.Los halogenuros alcalinos son materiales que permiten la difusión de los iones en su estructura, por ello los utilizamos como matriz para la formación de NS luminiscentes, las cuales se han formado por la impurificación con impurezas divalentes como los iones de europio (Eu²+) o manganeso (Mn²+), por ejemplo. La forma y el tamaño de las NS influencian fuertemente en la longitud de onda de absorción, emisión y excitación. Siendo de este modo muy importante el estudio sobre el tipo de impureza y las condiciones en la que se autorganizan para formar diferentes NS, las cuales pueden ser utilizadas como sensores o emisores de luz para potenciales dispositivos en nanoptoelectrónica.
- 26 June 2015
- Published by Elsevier in International Journal of Multiphase Flow
- Vol. 76, 86-100
Dynamics and acoustic energy dissipation in conical bubble collapse
- 26 June 2015
- Published by Elsevier in International Journal of Multiphase Flow
- Vol. 76, 86-100
Dynamics and acoustic energy dissipation in conical bubble collapse
- 22 April 2015
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 7 (21) , 9607-9613
A magnonic gas sensor based on magnetic nanoparticles
In this paper, we propose an innovative, simple and inexpensive gas sensor based on the variation in the magnetic properties of nanoparticles due to their interaction with gases. To measure the nanoparticle response a magnetostatic spin wave (MSW) tunable oscillator has been developed using an yttrium iron garnet (YIG) epitaxial thin film as a delay line (DL). The sensor has been prepared by coating a uniform layer of CuFe2O4 nanoparticles on the YIG film. The unperturbed frequency of the oscillator is determined by a bias magnetic field, which is applied parallel to the YIG film and perpendicularly to the wave propagation direction. In this device, the total bias magnetic field is the superposition of the field of a permanent magnet and the field associated with the layer of magnetic nanoparticles. The perturbation produced in the magnetic properties of the nanoparticle layer due to its interaction with gases induces a frequency shift in the oscillator, allowing the detection of low concentrations of gases. In order to demonstrate the ability of the sensor to detect gases, it has been tested with organic volatile compounds (VOCs) which have harmful effects on human health, such as dimethylformamide, isopropanol and ethanol, or the aromatic hydrocarbons like benzene, toluene and xylene more commonly known by its abbreviation (BTX). All of these were detected with high sensitivity, short response time, and good reproducibility.
- 22 April 2015
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 7 (21) , 9607-9613
A magnonic gas sensor based on magnetic nanoparticles
In this paper, we propose an innovative, simple and inexpensive gas sensor based on the variation in the magnetic properties of nanoparticles due to their interaction with gases. To measure the nanoparticle response a magnetostatic spin wave (MSW) tunable oscillator has been developed using an yttrium iron garnet (YIG) epitaxial thin film as a delay line (DL). The sensor has been prepared by coating a uniform layer of CuFe2O4 nanoparticles on the YIG film. The unperturbed frequency of the oscillator is determined by a bias magnetic field, which is applied parallel to the YIG film and perpendicularly to the wave propagation direction. In this device, the total bias magnetic field is the superposition of the field of a permanent magnet and the field associated with the layer of magnetic nanoparticles. The perturbation produced in the magnetic properties of the nanoparticle layer due to its interaction with gases induces a frequency shift in the oscillator, allowing the detection of low concentrations of gases. In order to demonstrate the ability of the sensor to detect gases, it has been tested with organic volatile compounds (VOCs) which have harmful effects on human health, such as dimethylformamide, isopropanol and ethanol, or the aromatic hydrocarbons like benzene, toluene and xylene more commonly known by its abbreviation (BTX). All of these were detected with high sensitivity, short response time, and good reproducibility.