Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Daniel Francis has a total of 83 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Methane monitoring in faecal headspace gas using mid-IR laser spectroscopy with a hollow waveguide gas cell

    by Daniel Francis, Jane Hodgkinson, Célia Lourenço, Dawn P. Fowler, Stephen E. Staines, Christopher Walton, Ralph P. Tatam

    The feasibility of using laser spectroscopy for analysis of the headspace gas emanating from biological samples is demonstrated by monitoring the concentration of methane produced by bovine faeces. The spectrometer consists of a 7.8 µm quantum cascade laser operating in the intra-pulse mode and a 4.79 m pathlength hollow silica waveguide gas cell. Concentration measurements using known concentrations of methane demonstrate a limit of detection of 116 ppb, and Allan-Werle deviation analysis indicates a minimum detectable absorbance of 9.5 × 10 −5 at an integration time of 45 s. A custom-designed PTFE enclosure with an embedded heating element was designed to contain the faecal samples. Filtered ambient air pumped through the instrument at a controlled rate of 5 ml/min was used to transfer the headspace gas from the sample container to the gas cell. Methane production was found to vary depending on the sample, with one sample reaching an approximate equilibrium of 13.9 ppm after 40 minutes and another, measured for longer, reaching an equilibrium of 11.4 ppm after 2 hours. These findings demonstrate the potential of laser spectroscopy for volatile biomarker analysis, with significant promise for non-invasive point-of-care diagnostics.

  • Open Access

    Performance of low-coherence and confocal refractometry with reduced index contrast

    by Daniel Francis, Jonathan M. Hallam, Ralph P. Tatam

    This paper looks to evaluate the performance of combined low-coherence and confocal refractometry under conditions of reduced refractive index contrast. The instrument measures the refractive index and thickness of transparent objects using a fibre-based low-coherence interferometer with a line-scan spectrometer. A sample was designed that mimics the on-axis structure of the eye, consisting of a lens tube holding a pair of windows surrounded on either side by fluid chambers and sealed at the far end by a diffuse black metallic plug. Sucrose solutions with a range of concentrations were injected into the fluid chambers, providing a linear variation in refractive index of 1.3330 to 1.4416. The instrument was used to simultaneously measure both the phase and group refractive indices n p and n g , as well as the physical thickness t of the windows and the fluid in the chambers. Although the measurement accuracy is shown to decrease with reduced refractive index contrast, it remains better than 0.6% over all measured components for sucrose concentrations of up to 60.3%, which is close to the saturation limit.

  • Open Access

    Long-wave infrared pulsed external-cavity QCL spectrometer using a hollow waveguide gas cell

    by Daniel Francis, Jane Hodgkinson, Ralph P. Tatam

    A spectrometer built using an external cavity pulsed quantum cascade laser is described. The spectrometer has a tuning range from 10 – 13 µm (1,000 – 769 cm−1) and is designed to target volatile organic compounds (VOCs) which often exhibit water-free molecular absorption within the region. The spectrometer utilizes a hollow silica waveguide gas cell which has an internal volume of a few millilitres, a fast response time (∼1 s), and is advantageous when only low sample volumes, similar to the cell volume, are available. Propane is used as a test gas because it is easy to handle, and its spectral profile is comparable to VOCs of interest. Its absorption in the region is primarily within the ν21 band which spans from 10.55 – 11.16 µm (948 – 896 cm−1). Spectral measurements at a range of concentrations show good linearity and an Allan deviation of absorbance values recorded over a 100-minute period indicates a minimum detectable absorbance of 3.5×10−5 at an integration time of 75 s.


  • Open Access

    Low-coherence and broadband confocal refractometry: reducing the measurement time

    by D Francis, J M Hallam, R P Tatam

    This paper describes the steps taken to improve the measurement speed of a combined low-coherence and confocal refractive index measurement system. The instrument measures the refractive index and thickness of transparent plates using a fibre-based low-coherence interferometer with a line-scan spectrometer. The spectrometer allows on-line dispersion measurement which is necessary to derive the sample thickness t as well as both the phase and group refractive indices n p, n g. The measurements were performed on a sample with six surfaces consisting of three glass windows mounted in a lens tube. Experimental results show that a measurement time of 4.4 s for the multi-layered object, which has a total thickness of approximately 10.5 mm, can be achieved whilst maintaining an accuracy of better than 0.1% for n p, n g, and t. This represents an approximately hundredfold improvement over previously published measurements.


  • Open Access

    Ratiometric pathlength calibration of integrating sphere-based absorption cells

    by Sarah Bergin, Jane Hodgkinson, Dan Francis, R. P. Tatam

    Chemical sensors based on optical absorption require accurate knowledge of the optical pathlength of the sample cell. Integrating spheres offer increased pathlengths compared to single pass cells combined with tolerance to misalignment, making them attractive for use in challenging environments subject to vibration. However, the equivalent optical pathlength can be degraded by dirt and / or condensation on the inner surface of the sphere. We present a new scheme for in-situ calibration that uses a ratiometric two-beam approach. Results are presented for an integrating sphere used in the measurement of methane by tunable diode laser spectroscopy (TDLS) at 1651nm. Reduced sphere reflectivity was simulated by applying small areas of black tape on the inner surface. At methane concentrations of 1500ppm and 3125 ppm, for areas of contamination up to 2.3% of the sphere wall, the technique reduced the error from over 50% to within ±4%. At a concentration of 6250 ppm and the most severe fouling corresponding to 2.9% wall coverage, the technique reduced the error from 55-65% to within ±11%.


  • In-situ pathlength calibration of integrating spheres used in measurement of absorbance

    by Nicholas M. Davis, Stephen E. Staines, Jane Hodgkinson, Sarah Bergin, Daniel Francis, Ralph P. Tatam, Dackson Masiyano

    When used as samples cells for optical absorbance measurements, integrating spheres offer increased pathlengths compared to single pass cells combined with tolerance to misalignment. This makes them attractive during alignment of optical instruments and in challenging environments subject to vibration. However, integrating spheres can suffer problems when used in sensitive and / or accurate absorbance measurement. We present our work to date to address these issues in high resolution laser spectroscopy. Firstly, optical interference effects include both random laser speckle and structured interference fringes created by optical feedback to the laser. Secondly, the sphere’s optical pathlength is a combination of multiple paths that take an exponential pathlength distribution. At low values of absorbance, the measured signal is linear with concentration, but at higher absorbances signals follow a nonlinear but predictable function of absorbance. Thirdly, our most recent work concerns calibration of the optical pathlength, which is a sensitive function of its internal reflectivity. In-situ calibration is needed if the sphere is to be used in dirty environments or with condensing samples. Measurements from multiple independent sources and / or detectors are combined to provide compensation from fouling of the sphere walls and windows. Results are presented for an integrating sphere used in the measurement of methane. The emission from a tunable DFB laser at 1651nm was tuned across the gas absorption line to measure its concentration. Reduced sphere reflectivity was simulated by applying small areas of black tape on the inner surface. Finally, we give an example of one application where our results are being put into practice: use of an integrating sphere with a tunable laser at 3.3μm to measure atmospheric methane, installed on a two seater light aircraft.


  • Refractive index and dispersion measurement using low-coherence interferometry with broadband confocal scanning

    by Daniel Francis, Helen D. Ford, Ralph P. Tatam

    Measurement of the refractive index and thickness of transparent plates is demonstrated using combined low-coherence interferometry and confocal scanning. The low-coherence measurement provides a quantity related to the group index and the confocal scan provides a parameter related to the phase index. Calculation of both the phase and group indices also requires a measurement of the confocal parameter at multiple wavelengths. This is achieved using a broadband source and a line-scan spectrometer to interrogate different regions of the spectrum. Measurements are made on a range of transparent optical materials with the mean percentage errors of each measurand being 0.08%, 0.06%, and 0.12% for np, ng, and thickness t respectively.

  • Open Access

    Spectrometer-based refractive index and dispersion measurement using low-coherence interferometry with confocal scanning

    by Daniel Francis, Helen D. Ford, Ralph P. Tatam

    This paper describes a technique for measuring refractive index and thickness of transparent plates using a fibre-optic low-coherence interferometer. The interferometer is used to independently measure quantities related to the phase and group refractive indices, np and ng, of the material under investigation. Additionally, the dispersion of the phase index dependent quantity is measured by taking advantage of the range of wavelengths available from a broadband source. These three quantities are related to simultaneously yield np and ng as well as the geometrical thickness t of the sample. Measurements are presented for a range of transparent materials including measurements of the ordinary and extraordinary refractive indices of a birefringent sapphire window. The mean percentage errors across all the samples tested were 0.09% for np, 0.08% for np, and 0.11% for t.


  • Mid-IR spectroscopic instrumentation for point-of-care diagnosis using a hollow silica waveguide gas cell

    by Daniel Francis, Jane Hodgkinson, Christopher Walton, Jeremy Sizer, Paul Black, Beth Livingstone, Dawn P. Fowler, Mitesh K. Patel, Ralph P. Tatam


  • Open Access

    Low-volume, fast response-time hollow silica waveguide gas cells for mid-IR spectroscopy

    by Daniel Francis, Jane Hodgkinson, Beth Livingstone, Paul Black, Ralph P. Tatam

    Hollow silica waveguides (HSWs) are used to produce long path length, low-volume gas cells, and are demonstrated with quantum cascade laser spectroscopy. Absorption measurements are made using the intrapulse technique, which allows measurements to be made across a single laser pulse. Simultaneous laser light and gas coupling is achieved through the modification of commercially available gas fittings with low dead volume. Three HSW gas cell configurations with different path lengths and internal diameters are analyzed and compared with a 30 m path length astigmatic Herriott cell. Limit of detection measurements are made for the gas cells using methane at a wavelength 7.82 μm. The lowest limit of detection was provided by HSW with a bore diameter of 1000 μm and a path length of 5 m and was measured to be 0.26 ppm, with a noise equivalent absorbance of 4.1×10−4. The long-term stability of the HSW and Herriott cells is compared through analysis of the Allan–Werle variance of data collected over a 24 h period. The response times of the HSW and Herriott cells are measured to be 0.8 s and 36 s, respectively.