Stéphane Cariou
Research Subjects
Stéphane Cariou has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Jean-Louis Fanlo
LGEI Laboratory
2 shared publicationsBudagwa Assumani
Total Feluy, Zone Industrielle Feluy C
1 shared publicationEvelyne Touraud
Laboratoire Génie de l'Environnement et des Risques Industriels Ecole des mines d'Alès, 6 avenue de Clavières 30319 Ales cedex France
1 shared publicationFrédéric Picard
Hutchinson S.A.
1 shared publicationIsabelle Betremieux
Total S.A
1 shared publicationJacky Montmain
Ecole des Mines d’Alès
1 shared publication
Latest Publications
- 18 May 2018
- Published by Springer Nature
- p. 562-573
Reliability Improvement of Odour Detection Thresholds Bibliographic Data
- 18 May 2018
- Published by Springer Nature
- p. 562-573
Reliability Improvement of Odour Detection Thresholds Bibliographic Data
- 11 June 2016
- Published by Springer Nature
- p. 238-249
Towards a Non-oriented Approach for the Evaluation of Odor Quality
- 11 June 2016
- Published by Springer Nature
- p. 238-249
Towards a Non-oriented Approach for the Evaluation of Odor Quality
- 14 November 2014
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 91 (2) , 426-430
Treatment of complex gaseous emissions emitted by a rendering facility using a semi‐industrial biofilter
BACKGROUND: To improve process design, and scale‐up of gas biofilters, a thorough understanding of compounds degradation mechanisms within model engineering biofilters is needed. The aim of this study is then to investigate the spatial distribution of pollutants removal within an experimental semi‐industrial biofilter fed with industrial emissions from a rendering plant.RESULTS: A stratification pattern of pollutants removal has been highlighted: nitrogenous compounds, esters, volatile fatty acids (VFA), alcohols, ketones and aldehydes are completely or mostly removed especially in the biofilter layers near the gas inlet. In return, the removal of sulphur compounds seems to begin when nitrogenous and oxygenated compounds are almost fully degraded. A sequential degradation of sulphur compounds is also observed: hydrogen sulphide is eliminated in the biofilter section near the gas inlet while methylmercaptan (removal efficiency 87%) and dimethyl disulphide (DMDS) (removal efficiency 73%) are mainly eliminated in the second half of the column.CONCLUSION: An on‐site semi‐industrial biofilter used for waste gas abatement in an animal‐rendering plant exhibited spatial distribution of the compounds removal efficiency. The removal of organic sulphur compounds is not complete. Hence, this work emphasizes the importance of improving gas biofilters to achieve complete elimination of pollutants causing unpleasant odours. © 2014 Society of Chemical Industry
- 14 November 2014
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 91 (2) , 426-430
Treatment of complex gaseous emissions emitted by a rendering facility using a semi‐industrial biofilter
BACKGROUND: To improve process design, and scale‐up of gas biofilters, a thorough understanding of compounds degradation mechanisms within model engineering biofilters is needed. The aim of this study is then to investigate the spatial distribution of pollutants removal within an experimental semi‐industrial biofilter fed with industrial emissions from a rendering plant.RESULTS: A stratification pattern of pollutants removal has been highlighted: nitrogenous compounds, esters, volatile fatty acids (VFA), alcohols, ketones and aldehydes are completely or mostly removed especially in the biofilter layers near the gas inlet. In return, the removal of sulphur compounds seems to begin when nitrogenous and oxygenated compounds are almost fully degraded. A sequential degradation of sulphur compounds is also observed: hydrogen sulphide is eliminated in the biofilter section near the gas inlet while methylmercaptan (removal efficiency 87%) and dimethyl disulphide (DMDS) (removal efficiency 73%) are mainly eliminated in the second half of the column.CONCLUSION: An on‐site semi‐industrial biofilter used for waste gas abatement in an animal‐rendering plant exhibited spatial distribution of the compounds removal efficiency. The removal of organic sulphur compounds is not complete. Hence, this work emphasizes the importance of improving gas biofilters to achieve complete elimination of pollutants causing unpleasant odours. © 2014 Society of Chemical Industry
- 10 December 2005
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 384 (2) , 468-474
Double-layer Tedlar bags: a means to limit humidity evolution of air samples and to dry humid air samples
Tedlar bags, which are widely used to collect air samples, especially VOCs and odorous atmospheres, can allow humidity to diffuse when relative humidity levels differ between the inside and outside. Starting with dry air inside the bag and humid air outside, we monitored equilibrium times under several conditions showing the evolution and influence of collected volumes and exposed surfaces. A double-film Tedlar bag was made, to limit the impact of external humidity on a sample at low humidity level. With the addition of a drying agent between both films, the evolution of humidity of a sample can be stopped for several hours. When a VOC mixture was monitored in a humid atmosphere, humidity was decreased but no significant evolution of VOC concentrations was observed.
- 10 December 2005
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 384 (2) , 468-474
Double-layer Tedlar bags: a means to limit humidity evolution of air samples and to dry humid air samples
Tedlar bags, which are widely used to collect air samples, especially VOCs and odorous atmospheres, can allow humidity to diffuse when relative humidity levels differ between the inside and outside. Starting with dry air inside the bag and humid air outside, we monitored equilibrium times under several conditions showing the evolution and influence of collected volumes and exposed surfaces. A double-film Tedlar bag was made, to limit the impact of external humidity on a sample at low humidity level. With the addition of a drying agent between both films, the evolution of humidity of a sample can be stopped for several hours. When a VOC mixture was monitored in a humid atmosphere, humidity was decreased but no significant evolution of VOC concentrations was observed.