Kazuhiro Hayashi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kazuhiro Hayashi has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
Taiki Saito
7 shared publications- Masayoshi Nakashima
Kobori Research Complex Inc. Minato Ward Tokyo Japan
5 shared publications Masayoshi Nakashima
Professor, Disaster Prevention Research Institute, Kyoto Univ., Kyoto 611-0011, Japan
4 shared publications- Hiroyuki Inamasu
École Polytechnique Fédérale de Lausanne
3 shared publications - Masahiro Kurata
Kyoto Univ
3 shared publications - Po-Chien Hsiao
Department of Civil and Environmental Engineering, University of Washington, Seattle, WA 98195-2700
3 shared publications
Latest Publications
- 19 November 2024
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 54 (2) , 604-617
Insights from large‐scale shake table testing: Key criticisms and potential solutions
This article presents the authors' experience with large‐scale shaking table tests conducted in Japan using the E‐Defense shaking table. The discussion focuses on four criticisms often addressed regarding the utilities of large‐scale shaking table tests. Potential solutions to mitigate such criticisms are discussed based on shaking table tests conducted for a pair of three‐story wooden houses. The first criticism is that the test specimen anchored rigidly to a rigid shaking table is not a reproduction of actual structures supported by soils and foundations. A model ground was developed in a large sandbox, which occupied about 85% of the total specimen weight, supported the house, and the entire soil‐structure system was shaken. Considerable sliding occurred, having lessened the earthquake forces exerted and resultant damage to the superstructure. The second criticism is that a single specimen test, regardless of its size, cannot provide sufficient information for generalizing the behavior and performance. Empirical equations between the maximum story drift and the change in the natural frequency were developed from a series of shaking table tests. Using such empirical equations might promote quick damage assessment of individual houses when suffering from actual earthquakes. The third criticism is the importance of public appeal and eventual support from the general public to secure the budget to operate large‐scale testing facilities. The example test featured two nearly identical specimens placed on the table with different support conditions. The apparent difference in response revealed the effect of support conditions on seismic performance. The fourth criticism is the importance of increasing the number of experimental projects to balance the operation budget. Most of the preparation in the example test was accomplished in an open yard adjacent to the shaking table, and the test specimens were quickly assembled on the table using indoor cranes. The table occupation was four out of 35 weeks of the entire test duration.
- 19 November 2024
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 54 (2) , 604-617
Insights from large‐scale shake table testing: Key criticisms and potential solutions
This article presents the authors' experience with large‐scale shaking table tests conducted in Japan using the E‐Defense shaking table. The discussion focuses on four criticisms often addressed regarding the utilities of large‐scale shaking table tests. Potential solutions to mitigate such criticisms are discussed based on shaking table tests conducted for a pair of three‐story wooden houses. The first criticism is that the test specimen anchored rigidly to a rigid shaking table is not a reproduction of actual structures supported by soils and foundations. A model ground was developed in a large sandbox, which occupied about 85% of the total specimen weight, supported the house, and the entire soil‐structure system was shaken. Considerable sliding occurred, having lessened the earthquake forces exerted and resultant damage to the superstructure. The second criticism is that a single specimen test, regardless of its size, cannot provide sufficient information for generalizing the behavior and performance. Empirical equations between the maximum story drift and the change in the natural frequency were developed from a series of shaking table tests. Using such empirical equations might promote quick damage assessment of individual houses when suffering from actual earthquakes. The third criticism is the importance of public appeal and eventual support from the general public to secure the budget to operate large‐scale testing facilities. The example test featured two nearly identical specimens placed on the table with different support conditions. The apparent difference in response revealed the effect of support conditions on seismic performance. The fourth criticism is the importance of increasing the number of experimental projects to balance the operation budget. Most of the preparation in the example test was accomplished in an open yard adjacent to the shaking table, and the test specimens were quickly assembled on the table using indoor cranes. The table occupation was four out of 35 weeks of the entire test duration.
- 10 December 2022
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 26 (12) , 2160-2171
Seismic performance of concrete-filled steel tube columns using ultra-high-strength steel under long-period ground motion demands
The long-period ground motions observed in recent subduction-zone earthquake events (e.g., 2011 Tohoku earthquake in Japan) have subjected high-rise buildings to large numbers of lateral cyclic deformations. Concrete-filled steel tube (CFT) columns, which are often utilized in high-rise buildings in Japan, have been studied under lateral demands with a few loading cycles. However, their seismic performance under a larger number of repeated loading cycles is a considerable concern for future seismic events. Moreover, the use of ultra-high-strength steel materials in CFT columns has recently gained popularity. However, studies on CFT columns made using ultra-high-strength steel materials are still limited. In this study, the seismic performance of CFT columns made using conventional steel or ultra-high-strength steel were investigated experimentally under repeated lateral loading cycles. Four cantilever CFT column specimens were tested with a combined constant compressive axial loading and cyclic symmetric lateral loading. Each specimen was tested with two different lateral loading protocols: the conventional protocol with two cycles at each drift amplitude level, and a second protocol with twenty cycles at each amplitude level to represent the lateral drift demand under a long-period ground motion. The effects of the number of loading cycles on the seismic performance of the CFT columns are discussed. Based on the experimental observations, design recommendations are also presented. Moreover, an approach is proposed to estimate the onset of local buckling of the CFT columns under seismic loading.
- 10 December 2022
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 26 (12) , 2160-2171
Seismic performance of concrete-filled steel tube columns using ultra-high-strength steel under long-period ground motion demands
The long-period ground motions observed in recent subduction-zone earthquake events (e.g., 2011 Tohoku earthquake in Japan) have subjected high-rise buildings to large numbers of lateral cyclic deformations. Concrete-filled steel tube (CFT) columns, which are often utilized in high-rise buildings in Japan, have been studied under lateral demands with a few loading cycles. However, their seismic performance under a larger number of repeated loading cycles is a considerable concern for future seismic events. Moreover, the use of ultra-high-strength steel materials in CFT columns has recently gained popularity. However, studies on CFT columns made using ultra-high-strength steel materials are still limited. In this study, the seismic performance of CFT columns made using conventional steel or ultra-high-strength steel were investigated experimentally under repeated lateral loading cycles. Four cantilever CFT column specimens were tested with a combined constant compressive axial loading and cyclic symmetric lateral loading. Each specimen was tested with two different lateral loading protocols: the conventional protocol with two cycles at each drift amplitude level, and a second protocol with twenty cycles at each amplitude level to represent the lateral drift demand under a long-period ground motion. The effects of the number of loading cycles on the seismic performance of the CFT columns are discussed. Based on the experimental observations, design recommendations are also presented. Moreover, an approach is proposed to estimate the onset of local buckling of the CFT columns under seismic loading.
- 24 May 2022
- Published by Elsevier in Soil Dynamics and Earthquake Engineering
- Vol. 159
Development of new passive vibration control system in coupled structures with block and tackle
- 24 May 2022
- Published by Elsevier in Soil Dynamics and Earthquake Engineering
- Vol. 159
Development of new passive vibration control system in coupled structures with block and tackle
- Open Access
- 1 January 2022
- Published by Japan Association for Earthquake Engineering in Journal of Japan Association for Earthquake Engineering
- Vol. 22 (5) , 5_1-5_24
Simple Estimation Method of Building Deformation Using Two Seismometers without Precise Time Synchronization
本論は,建物の1階と上階に設置した2台の地震計を用いた地震計間の最大変形角を算定する一手法を提案する.実用時の汎用性を念頭に置き,建物の構造詳細情報は不要,2台の地震計の有線接続とロガーによる時刻同期は不要,地震計はスマホ内蔵などの加速度センサの計測精度でも評価可能なことを目指す.但し,地震計は,NTPサーバとの交信による内部時計間の時刻差程度の同期精度があること,所定のサンプリング周波数に補正されていることを必要要件とする.建物の応答を等価1質点モデルで推定する.地震計間の水平変形を算定する基本式の未知数である最大応答時の1次固有円振動数と減衰定数を,上下階の加速度記録のフーリエ振幅比のピークから求解する.前回地震時の終動部で評価した弾性1次固有振動数を利用すること,加速度記録を一定間隔で分割することで多数のピークから最大応答時の1次固有振動数を絞り込むことが本論の特徴である.E-ディフェンスでのRC造,S造の4つの実大加振実験結果を用いて,提案方法による評価精度を検証した.検証の結果,弾性域から塑性域に至る範囲において,実験に用いたレーザー変位計の測定値と提案手法の評価結果が概ね整合していることを確認した.なお,この検証は,1次モードが励起されやすい整形な建物,残留変形やねじれ変形が小さい場合の検証に留まるものである.主要動が長時間継続する地震動への適用,地盤との相互作用による影響が大きい建物への適用,様々な形状の建物への適用,加えて被災度判定の重要な指標である最大層間変形角の求解については本論の対象外とする.
- 1 January 2022
- Published by Japan Association for Earthquake Engineering in Journal of Japan Association for Earthquake Engineering
- Vol. 22 (5) , 5_1-5_24
Open AccessSimple Estimation Method of Building Deformation Using Two Seismometers without Precise Time Synchronization
本論は,建物の1階と上階に設置した2台の地震計を用いた地震計間の最大変形角を算定する一手法を提案する.実用時の汎用性を念頭に置き,建物の構造詳細情報は不要,2台の地震計の有線接続とロガーによる時刻同期は不要,地震計はスマホ内蔵などの加速度センサの計測精度でも評価可能なことを目指す.但し,地震計は,NTPサーバとの交信による内部時計間の時刻差程度の同期精度があること,所定のサンプリング周波数に補正されていることを必要要件とする.建物の応答を等価1質点モデルで推定する.地震計間の水平変形を算定する基本式の未知数である最大応答時の1次固有円振動数と減衰定数を,上下階の加速度記録のフーリエ振幅比のピークから求解する.前回地震時の終動部で評価した弾性1次固有振動数を利用すること,加速度記録を一定間隔で分割することで多数のピークから最大応答時の1次固有振動数を絞り込むことが本論の特徴である.E-ディフェンスでのRC造,S造の4つの実大加振実験結果を用いて,提案方法による評価精度を検証した.検証の結果,弾性域から塑性域に至る範囲において,実験に用いたレーザー変位計の測定値と提案手法の評価結果が概ね整合していることを確認した.なお,この検証は,1次モードが励起されやすい整形な建物,残留変形やねじれ変形が小さい場合の検証に留まるものである.主要動が長時間継続する地震動への適用,地盤との相互作用による影響が大きい建物への適用,様々な形状の建物への適用,加えて被災度判定の重要な指標である最大層間変形角の求解については本論の対象外とする.
- Open Access
- 1 January 2020
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2020 (1)
Fundamental Investigation on Seismic Retrofitting Method of Aging Concrete Structural Wall Using Carbon Fiber Sheet‐Constitutive Law of Rectangular Section
Aging building structure has become a world problem. This problem is particularly serious in developing and underdeveloped countries. The multihazard resilience and sustainability (e.g., seismic performance) decrease at the aging building. A construction method for strengthening aging‐reinforced concrete buildings by wrapping structural members with carbon fiber sheets has been proposed and implemented in recent years. Authors aim to develop a seismic retrofitting method of aging concrete structural wall with a rectangular cross section using carbon fiber sheets. In this paper, authors examined the stress‐strain relationship of concrete elements with rectangular cross sections reinforced by wrapping with carbon fiber sheets. Monotonic uniaxial compression tests were performed on 21 specimens using the ratio of the long side to the short side and the ratio of the element height to the short side of the concrete cross section, the weight of the carbon fiber sheet, and the chamfer radius of section corners as variables. The tests revealed that (1) the compressive strength decreases and ultimate strain increases as the ratio of the long to short side (longitudinal ratio) of the cross section increases even in a range the ratio exceeds 2 and (2) the ratio of the element height to the short side does not significantly affect the stress‐strain relationship. Furthermore, authors proposed evaluation formulas for the constitutive law of concrete elements with rectangular cross sections including the longitudinal ratio which exceeds 2 reinforced by carbon fiber sheets and confirmed that the formulas can reproduce the test results with good accuracy.
- 1 January 2020
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2020 (1)
Open AccessFundamental Investigation on Seismic Retrofitting Method of Aging Concrete Structural Wall Using Carbon Fiber Sheet‐Constitutive Law of Rectangular Section
Aging building structure has become a world problem. This problem is particularly serious in developing and underdeveloped countries. The multihazard resilience and sustainability (e.g., seismic performance) decrease at the aging building. A construction method for strengthening aging‐reinforced concrete buildings by wrapping structural members with carbon fiber sheets has been proposed and implemented in recent years. Authors aim to develop a seismic retrofitting method of aging concrete structural wall with a rectangular cross section using carbon fiber sheets. In this paper, authors examined the stress‐strain relationship of concrete elements with rectangular cross sections reinforced by wrapping with carbon fiber sheets. Monotonic uniaxial compression tests were performed on 21 specimens using the ratio of the long side to the short side and the ratio of the element height to the short side of the concrete cross section, the weight of the carbon fiber sheet, and the chamfer radius of section corners as variables. The tests revealed that (1) the compressive strength decreases and ultimate strain increases as the ratio of the long to short side (longitudinal ratio) of the cross section increases even in a range the ratio exceeds 2 and (2) the ratio of the element height to the short side does not significantly affect the stress‐strain relationship. Furthermore, authors proposed evaluation formulas for the constitutive law of concrete elements with rectangular cross sections including the longitudinal ratio which exceeds 2 reinforced by carbon fiber sheets and confirmed that the formulas can reproduce the test results with good accuracy.
- 23 April 2019
- Published by Taylor & Francis in Structural Engineering International
- Vol. 29 (3) , 370-376
Nonlinear Response and Damage Monitoring of a Concrete Pile as a Result of Soil Liquefaction
In past earthquake disasters, numerous building structure piles were damaged due to soil liquefaction occurring during the earthquake. Damage to these piles, because they are underground, is difficult to find. The authors aim to develop a monitoring method for pile damage based on superstructure dynamic response. This paper investigated the basic relationship between the damage of large cross section cementitious piles and the dynamic response of the super structure using a centrifuge test apparatus. A dynamically excited specimen used simple cross section pile models consisting of aluminum rod and mortar, saturated soil (Toyoura sand) of a relative density of 40% and a super-structure model of a natural period of 0.63 s. In the shaking table test under a 50G field, excitation was a total of 3 Rinkai waves at different amplitudes. The maximum acceleration of each of the excitations was 602, 336 and 299 gal. The centrifuge test demonstrated the liquefaction of saturated soil and the failure behavior of piles. In the test results, the damage to the piles affected the predominant period of acceleration response spectrum on the footing of the superstructure.
- 23 April 2019
- Published by Taylor & Francis in Structural Engineering International
- Vol. 29 (3) , 370-376
Nonlinear Response and Damage Monitoring of a Concrete Pile as a Result of Soil Liquefaction
In past earthquake disasters, numerous building structure piles were damaged due to soil liquefaction occurring during the earthquake. Damage to these piles, because they are underground, is difficult to find. The authors aim to develop a monitoring method for pile damage based on superstructure dynamic response. This paper investigated the basic relationship between the damage of large cross section cementitious piles and the dynamic response of the super structure using a centrifuge test apparatus. A dynamically excited specimen used simple cross section pile models consisting of aluminum rod and mortar, saturated soil (Toyoura sand) of a relative density of 40% and a super-structure model of a natural period of 0.63 s. In the shaking table test under a 50G field, excitation was a total of 3 Rinkai waves at different amplitudes. The maximum acceleration of each of the excitations was 602, 336 and 299 gal. The centrifuge test demonstrated the liquefaction of saturated soil and the failure behavior of piles. In the test results, the damage to the piles affected the predominant period of acceleration response spectrum on the footing of the superstructure.