Olivier Roussette
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Olivier Roussette has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Antoine Dazin
Arts et Métiers ParisTech, Lille, France
15 shared publications - Annie-Claude Bayeul-Lainé
Univ. Lille, CNRS, ONERA, Arts et Metiers Institute of Technology, Centrale Lille, UMR 9014 - LMFL - Laboratoire de Mécanique des fluides de Lille - Kampé de Fériet, F-59000 Lille, France
7 shared publications Patrick Dupont
Ecole Centrale de Lille, Villeneuve d'Ascq, Nord-Pas-de-Calais, FRANCE
4 shared publications- Pierric Joseph
Univ. Lille, CNRS, ONERA, Arts et Metiers Institute of Technology, Centrale Lille, UMR 9014—LMFL—Laboratoire de Mécanique des Fluides de Lille—Kampé de Fériet, F-59000 Lille, France
4 shared publications - Gérard Bois
Key Laboratory of Fluid and Power Machinery, Ministry of Education, Xihua University, No. 9999 Hongguang Avenue, Pidu District, Chengdu 610039, China
3 shared publications - Patrick Dupont
UMR CNRS 8107 Ecole Centrale de Lille/LML 20048 59651 Villeneuve d'Ascq CS France
3 shared publications
Latest Publications
- 11 May 2026
- Published by ASME International in Journal of Fluids Engineering
- Vol. 148 (7) , 1-60
Radial Forces Reconstruction on a Space Inducer From Casing Pressure Measurements
Axial inducers produce significant rotordynamic forces influenced by cavitation and flow rate. The decrease of the cavitation number increases the magnitude of the forces as does the decrease of the flow coefficient in experimental test rigs; these forces can be obtained by a balance mounted in the shaft. This can be expensive and can lead to some problems. This paper proposes a methodology to measure these forces using pressure signals at the casing for different axial and azimuthal locations, postprocessed by continuous wavelet transforms. The results obtained with this process are compared to reference signals coming from a six-components balance on the experimental water test-rig dedicated to the study of the performance and the unsteady phenomena in spatial inducer at the Fluid Mechanics Laboratory of Lille (LMFL). For the validation, different inducer geometries, flow rates, and rotational speeds are used. Finally, a calibration is determined to evaluate the uncertainty of this methodology.
- 11 May 2026
- Published by ASME International in Journal of Fluids Engineering
- Vol. 148 (7) , 1-60
Radial Forces Reconstruction on a Space Inducer From Casing Pressure Measurements
Axial inducers produce significant rotordynamic forces influenced by cavitation and flow rate. The decrease of the cavitation number increases the magnitude of the forces as does the decrease of the flow coefficient in experimental test rigs; these forces can be obtained by a balance mounted in the shaft. This can be expensive and can lead to some problems. This paper proposes a methodology to measure these forces using pressure signals at the casing for different axial and azimuthal locations, postprocessed by continuous wavelet transforms. The results obtained with this process are compared to reference signals coming from a six-components balance on the experimental water test-rig dedicated to the study of the performance and the unsteady phenomena in spatial inducer at the Fluid Mechanics Laboratory of Lille (LMFL). For the validation, different inducer geometries, flow rates, and rotational speeds are used. Finally, a calibration is determined to evaluate the uncertainty of this methodology.
- Open Access
- 3 November 2025
- Published by MDPI AG in International Journal of Turbomachinery, Propulsion and Power
- Vol. 10 (4) , 40
An Experimental Investigation by Particle Image Velocimetry of the Active Flow Control of the Stall Inception of an Axial Compressor
This paper presents results from active flow control experiments carried out on a single stage axial compressor. The flow under various forced conditions has been investigated using 2D 2C particle image velocimetry (PIV) on three radial planes along the blades’ span and two different operating points corresponding to the minimum mass flow at which the compressor naturally stalls, and to the lower stability limit reached with the control system activated. In particular, a control strategy using continuous blowing is compared with a pulsed one using the same injected mass flow. Comparison is performed with the base flow without control (when available), or with each other, based on the PIV results in the form of relative velocity maps or inlet/outlet flow characteristics.
- 3 November 2025
- Published by MDPI AG in International Journal of Turbomachinery, Propulsion and Power
- Vol. 10 (4) , 40
Open AccessAn Experimental Investigation by Particle Image Velocimetry of the Active Flow Control of the Stall Inception of an Axial Compressor
This paper presents results from active flow control experiments carried out on a single stage axial compressor. The flow under various forced conditions has been investigated using 2D 2C particle image velocimetry (PIV) on three radial planes along the blades’ span and two different operating points corresponding to the minimum mass flow at which the compressor naturally stalls, and to the lower stability limit reached with the control system activated. In particular, a control strategy using continuous blowing is compared with a pulsed one using the same injected mass flow. Comparison is performed with the base flow without control (when available), or with each other, based on the PIV results in the form of relative velocity maps or inlet/outlet flow characteristics.
- Open Access
- 16 March 2022
- Published by MDPI AG in International Journal of Turbomachinery, Propulsion and Power
- Vol. 7 (1) , 10
Stall Margin Improvement in an Axial Compressor by Continuous and Pulsed Tip Injection
Stall and surge are strong limitations in the operating range of compressors and thus one of the major limits of jet engine performance. A promising way to push the stability limit of compression machines is to inject a small amount of flow at the blade tip to alter the physical mechanism responsible for stall onset. This study focuses on the experimental performance of such a system. To do so, an axial compressor test bench was equipped with 40 actuators connected to an auxiliary pressurised air supply system. They were able to generate high-speed jet blowing just at the tip of the rotor blades. The opening of each actuator was controlled by an electromagnetic valve. This allowed generating continuous or pulsed jets with frequencies up to 500 Hz at different duty cycles. The performance of the control system was investigated for various control strategies, where the injected flow rate, the injection angle, the number of injectors, the jet frequency and the duty cycle were systematically varied. This paper is concluded by a study of the energy balance of the system for various configurations. To the best of the authors’ knowledge, this constitutes a rarely seen analysis in the literature.
- 16 March 2022
- Published by MDPI AG in International Journal of Turbomachinery, Propulsion and Power
- Vol. 7 (1) , 10
Open AccessStall Margin Improvement in an Axial Compressor by Continuous and Pulsed Tip Injection
Stall and surge are strong limitations in the operating range of compressors and thus one of the major limits of jet engine performance. A promising way to push the stability limit of compression machines is to inject a small amount of flow at the blade tip to alter the physical mechanism responsible for stall onset. This study focuses on the experimental performance of such a system. To do so, an axial compressor test bench was equipped with 40 actuators connected to an auxiliary pressurised air supply system. They were able to generate high-speed jet blowing just at the tip of the rotor blades. The opening of each actuator was controlled by an electromagnetic valve. This allowed generating continuous or pulsed jets with frequencies up to 500 Hz at different duty cycles. The performance of the control system was investigated for various control strategies, where the injected flow rate, the injection angle, the number of injectors, the jet frequency and the duty cycle were systematically varied. This paper is concluded by a study of the energy balance of the system for various configurations. To the best of the authors’ knowledge, this constitutes a rarely seen analysis in the literature.
- Open Access
- 23 November 2021
- Published by MDPI AG in International Journal of Turbomachinery, Propulsion and Power
- Vol. 6 (4) , 43
Experimental and Numerical Analysis of a Compressor Stage under Flow Distortion
On many occasions, fan or compressor stages have to face azimuthal flow distortion at inlet, which affects their performance and stability. These flow distortions can be caused by external events or by some particular geometrical features. The aim of this work is to propose a joined numerical and experimental analysis of the flow behavior in a single axial compressor stage under flow distortion. The distortions are generated by different grids that are placed upstream to the rotor. Experimentally, the flow analysis is based on the measurements obtained by a series of unsteady pressure sensors flush-mounted at the casing of the machine rotor. URANS computations are conducted using the elsA software. The flow distortion is simulated by a drop of stagnation pressure ratio at the inlet boundary condition. The study is focusing first on the ability of a pressure drop, imposed as an inlet boundary condition in CFD, to reproduce accurately the effect of a flow distortion. The analysis is conducted using singular value decomposition (SVD) and dynamic mode decomposition (DMD). A special attention is then paid, on the experimental level, to the arising of rotating stall, from the onset of the instability up to completely developed stall cells.
- 23 November 2021
- Published by MDPI AG in International Journal of Turbomachinery, Propulsion and Power
- Vol. 6 (4) , 43
Open AccessExperimental and Numerical Analysis of a Compressor Stage under Flow Distortion
On many occasions, fan or compressor stages have to face azimuthal flow distortion at inlet, which affects their performance and stability. These flow distortions can be caused by external events or by some particular geometrical features. The aim of this work is to propose a joined numerical and experimental analysis of the flow behavior in a single axial compressor stage under flow distortion. The distortions are generated by different grids that are placed upstream to the rotor. Experimentally, the flow analysis is based on the measurements obtained by a series of unsteady pressure sensors flush-mounted at the casing of the machine rotor. URANS computations are conducted using the elsA software. The flow distortion is simulated by a drop of stagnation pressure ratio at the inlet boundary condition. The study is focusing first on the ability of a pressure drop, imposed as an inlet boundary condition in CFD, to reproduce accurately the effect of a flow distortion. The analysis is conducted using singular value decomposition (SVD) and dynamic mode decomposition (DMD). A special attention is then paid, on the experimental level, to the arising of rotating stall, from the onset of the instability up to completely developed stall cells.
- Open Access
- 7 July 2020
- Published by MDPI AG in International Journal of Turbomachinery, Propulsion and Power
- Vol. 5 (3) , 16
Comparison and Sensibility Analysis of Warning Parameters for Rotating Stall Detection in an Axial Compressor
The present paper aims at evaluating the surveillance parameters used for early stall warning in axial compressors, and is based on unsteady pressure measurements at the casing of a single stage axial compressor. Two parameters—Correlation and Root Mean Square (RMS)—are first compared and their relative performances discussed. The influence of sensor locations (in both radial and axial directions) is then considered, and the role of the compressor’s geometrical irregularities in the behavior of the indicators is clearly highlighted. The influence of the throttling process is also carefully analyzed. This aspect of the experiment’s process appears to have a non-negligible impact on the stall warning parameters, despite being poorly documented in the literature. This last part of this research work allow us to get a different vision of the alert parameters compared to what is classically done in the literature, as the level of irregularity that is reflected by the magnitude of the parameters appears to be an image of a given flow rate value, and not a clear indicator of the stall inception.
- 7 July 2020
- Published by MDPI AG in International Journal of Turbomachinery, Propulsion and Power
- Vol. 5 (3) , 16
Open AccessComparison and Sensibility Analysis of Warning Parameters for Rotating Stall Detection in an Axial Compressor
The present paper aims at evaluating the surveillance parameters used for early stall warning in axial compressors, and is based on unsteady pressure measurements at the casing of a single stage axial compressor. Two parameters—Correlation and Root Mean Square (RMS)—are first compared and their relative performances discussed. The influence of sensor locations (in both radial and axial directions) is then considered, and the role of the compressor’s geometrical irregularities in the behavior of the indicators is clearly highlighted. The influence of the throttling process is also carefully analyzed. This aspect of the experiment’s process appears to have a non-negligible impact on the stall warning parameters, despite being poorly documented in the literature. This last part of this research work allow us to get a different vision of the alert parameters compared to what is classically done in the literature, as the level of irregularity that is reflected by the magnitude of the parameters appears to be an image of a given flow rate value, and not a clear indicator of the stall inception.
- 15 July 2018
- Published by ASME International
Detailed Pressure Measurements During the Transition to Rotating Stall in an Axial Compressor: Influence of the Throttling Process
This paper presents experimental unsteady pressure measurements gathered on a single stage axial compressor during pre-stall and transition to stall operations. The aim of this study is to analyze the transition from a stable operating point to the fully developed rotating stall regime, and more specifically, the effect of the throttling process on the development of the instabilities. To do so, experiments have been repeated leading the compressor to stall operations with various throttling speed. On one hand, this paper analyses the effect of the throttling speed on the dynamic of the instability development from the first detection of spike type precursors to completely developed rotating stall. On the other hand, a stall warning signal based on the correlation of the instantaneous pressure signal with a reference pressure signal is built. The influence of the location of the pressure transducer used for the warning signal is first analyzed. Then an analysis of the effect of the throttling process on the time between the warning signal and the effective stall development is proposed.
- 15 July 2018
- Published by ASME International
Detailed Pressure Measurements During the Transition to Rotating Stall in an Axial Compressor: Influence of the Throttling Process
This paper presents experimental unsteady pressure measurements gathered on a single stage axial compressor during pre-stall and transition to stall operations. The aim of this study is to analyze the transition from a stable operating point to the fully developed rotating stall regime, and more specifically, the effect of the throttling process on the development of the instabilities. To do so, experiments have been repeated leading the compressor to stall operations with various throttling speed. On one hand, this paper analyses the effect of the throttling speed on the dynamic of the instability development from the first detection of spike type precursors to completely developed rotating stall. On the other hand, a stall warning signal based on the correlation of the instantaneous pressure signal with a reference pressure signal is built. The influence of the location of the pressure transducer used for the warning signal is first analyzed. Then an analysis of the effect of the throttling process on the time between the warning signal and the effective stall development is proposed.
- 14 March 2018
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 29 (4) , 045303
Experimental validation of an ultrasonic flowmeter for unsteady flows
An ultrasonic flowmeter was developed for further applications in cryogenic conditions and for measuring flow rate fluctuations in the range of 0 to 70 Hz. The prototype was installed in a flow test rig, and was validated experimentally both in steady and unsteady water flow conditions. A Coriolis flowmeter was used for the calibration under steady state conditions, whereas in the unsteady case the validation was done simultaneously against two methods: particle image velocimetry (PIV), and with pressure transducers installed flush on the wall of the pipe. The results show that the developed flowmeter and the proposed methodology can accurately measure the frequency and amplitude of unsteady fluctuations in the experimental range of 0–9 l s −1 of the mean main flow rate and 0–70 Hz of the imposed disturbances.
- 14 March 2018
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 29 (4) , 045303
Experimental validation of an ultrasonic flowmeter for unsteady flows
An ultrasonic flowmeter was developed for further applications in cryogenic conditions and for measuring flow rate fluctuations in the range of 0 to 70 Hz. The prototype was installed in a flow test rig, and was validated experimentally both in steady and unsteady water flow conditions. A Coriolis flowmeter was used for the calibration under steady state conditions, whereas in the unsteady case the validation was done simultaneously against two methods: particle image velocimetry (PIV), and with pressure transducers installed flush on the wall of the pipe. The results show that the developed flowmeter and the proposed methodology can accurately measure the frequency and amplitude of unsteady fluctuations in the experimental range of 0–9 l s −1 of the mean main flow rate and 0–70 Hz of the imposed disturbances.
- 20 October 2017
- Published by Springer Nature in Experiments in Fluids
- Vol. 58 (11) , 157
Fast X-ray imaging of cavitating flows
- 20 October 2017
- Published by Springer Nature in Experiments in Fluids
- Vol. 58 (11) , 157
Fast X-ray imaging of cavitating flows
- 10 February 2016
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 30 (2) , 549-556
Static pressure recovery analysis in the vane island diffuser of a centrifugal pump
- 10 February 2016
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 30 (2) , 549-556
Static pressure recovery analysis in the vane island diffuser of a centrifugal pump
- 31 December 2015
- Published by Korean Fluid Machinery Association in International Journal of Fluid Machinery and Systems
- Vol. 8 (4) , 274-282
Leakage Flow Influence on SHF pump model performances
- 31 December 2015
- Published by Korean Fluid Machinery Association in International Journal of Fluid Machinery and Systems
- Vol. 8 (4) , 274-282
Leakage Flow Influence on SHF pump model performances