Yasuaki Hori
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yasuaki Hori has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Akiko Hirai
National Institute of Advanced Industrial Science and Technology (Japan)
8 shared publications - Kaoru Minoshima
The University of Electro-Communications (UEC), 1-5-1 Chofugaoka, Chofu, Tokyo, Japan
6 shared publications - Takeshi Yasui
Institute of Post-LED Photonics (pLED) Tokushima University 2-1 Minami- Josanjima 770-8506 Tokushima Tokushima Japan
4 shared publications Tsutomu Araki
Department of Mechanical Science and Bioengineering, Graduate School of Engineering Science, Osaka University, Toyonaka, Osaka, 560-8531, Japan
4 shared publications- Yoshiaki Yasuno
Computational Optics Group, University of Tsukuba, Tsukuba, Japan
4 shared publications - Violeta Madjarova
Institute of Optical Materials and Technologies, Bulgarian Academy of Sciences, 1113 Sofia, Bulgaria
3 shared publications
Latest Publications
- Open Access
- 25 May 2026
- Published by Elsevier in Precision Engineering
- Vol. 102, 942-954
Non-contact absolute measurement of curved surface profiles using a scanning deflectometric profiler
- 25 May 2026
- Published by Elsevier in Precision Engineering
- Vol. 102, 942-954
Open AccessNon-contact absolute measurement of curved surface profiles using a scanning deflectometric profiler
- 15 December 2023
- Published by Elsevier in Measurement
- Vol. 225
Error investigation for SI traceable pitch calibration of one-dimensional grating by grazing-incidence small-angle X-ray scattering
- 15 December 2023
- Published by Elsevier in Measurement
- Vol. 225
Error investigation for SI traceable pitch calibration of one-dimensional grating by grazing-incidence small-angle X-ray scattering
- 11 November 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (2) , 025011
Quantitative evaluation and removal of periodic error caused by ghost reflections in a double-path homodyne interferometer
This paper discusses periodic error caused by ghost reflections in a double-path homodyne interferometer, which is difficult to be removed by so-called Heydemann’s method due to its unique frequency. The mechanism of the periodic error is represented by a theoretical equation established focusing on the number of round trips of a measurement light path. Based on the theory, it was found that specific periodic errors are caused by the measurement light reflected on one surface of an optical element. To evaluate the presence and removal of the periodic error, the self-evaluation method, which was extended to include ghost reflections, was applied. Experimental evidence shows that a wedge provided on that surface prevents unwanted reflections and reduces the periodic error to approximately 2 pm.
- 11 November 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (2) , 025011
Quantitative evaluation and removal of periodic error caused by ghost reflections in a double-path homodyne interferometer
This paper discusses periodic error caused by ghost reflections in a double-path homodyne interferometer, which is difficult to be removed by so-called Heydemann’s method due to its unique frequency. The mechanism of the periodic error is represented by a theoretical equation established focusing on the number of round trips of a measurement light path. Based on the theory, it was found that specific periodic errors are caused by the measurement light reflected on one surface of an optical element. To evaluate the presence and removal of the periodic error, the self-evaluation method, which was extended to include ghost reflections, was applied. Experimental evidence shows that a wedge provided on that surface prevents unwanted reflections and reduces the periodic error to approximately 2 pm.
- 1 October 2018
- Published by Elsevier in Precision Engineering
- Vol. 54, 206-211
A heterodyne interferometer constructed in an integrated optics and its metrological evaluation of a picometre-order periodic error
- 1 October 2018
- Published by Elsevier in Precision Engineering
- Vol. 54, 206-211
A heterodyne interferometer constructed in an integrated optics and its metrological evaluation of a picometre-order periodic error
- 1 January 2018
- Published by Elsevier in Precision Engineering
- Vol. 51, 388-392
Periodic error evaluation system for linear encoders using a homodyne laser interferometer with 10 picometer uncertainty
- 1 January 2018
- Published by Elsevier in Precision Engineering
- Vol. 51, 388-392
Periodic error evaluation system for linear encoders using a homodyne laser interferometer with 10 picometer uncertainty
- 1 January 2016
- Published by IOP Publishing in Metrologia
- Vol. 53 (1A) , 02001
Report on supplementary comparison COOMET.PR-S3: refractive index
The Supplementary Comparison COOMET.PR-S3 was carried out to ensure the correctness and comparability of refractive index of solid transparent materials in visible spectral range measured by the participants of the comparison within the uncertainties claimed for their measuring facility. COOMET.PR-S3 was conducted within the Regional Metrology Organization (RMO) "Euro-Asian Cooperation of National Metrological Institutions" known as COOMET, and has the RMO project number of 438/RU/08. The Comparison was piloted by the All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI). Five NMIs from three RMOs (COOMET, EURAMET and APMP) participated in the comparison. This report describes the measurement results of three prismatic samples made of different types of glass. Three participants, VNIIOFI, PTB and Ukrmetrteststandart have made measurements of the refractive index at the wavelengths of 480 nm, 509 nm, 546 nm, 589.3 nm, 644 nm, and three participants, VNIIOFI, INRiM and AIST at the wavelength of 632.8 nm. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 1 January 2016
- Published by IOP Publishing in Metrologia
- Vol. 53 (1A) , 02001
Report on supplementary comparison COOMET.PR-S3: refractive index
The Supplementary Comparison COOMET.PR-S3 was carried out to ensure the correctness and comparability of refractive index of solid transparent materials in visible spectral range measured by the participants of the comparison within the uncertainties claimed for their measuring facility. COOMET.PR-S3 was conducted within the Regional Metrology Organization (RMO) "Euro-Asian Cooperation of National Metrological Institutions" known as COOMET, and has the RMO project number of 438/RU/08. The Comparison was piloted by the All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI). Five NMIs from three RMOs (COOMET, EURAMET and APMP) participated in the comparison. This report describes the measurement results of three prismatic samples made of different types of glass. Three participants, VNIIOFI, PTB and Ukrmetrteststandart have made measurements of the refractive index at the wavelengths of 480 nm, 509 nm, 546 nm, 589.3 nm, 644 nm, and three participants, VNIIOFI, INRiM and AIST at the wavelength of 632.8 nm. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 24 April 2014
- Published by Optica Publishing Group in Applied Optics
- Vol. 53 (13) , 2793-2801
Prism-pair interferometer for precise measurement of the refractive index of optical glass by using a spectrum lamp
A prism-pair interferometer for a spectrum lamp was developed for precise measurement of the refractive index of a prism of optical glass. Previously we reported the prism-pair interferometer with a He–Ne laser light source, resulting in a measurement uncertainty of . However, most of the refractive-index values managed by optical glass manufacturers are conventionally measured with spectrum lamps. We have optimized the prism-pair interferometer for spectrum lamps and implemented a signal-processing technique from Fourier-transform spectroscopy. When the refractive index is measured, the wavelength of the spectrum lamp is simultaneously calibrated by part of the interferometer, so that the resulting refractive index is traceable to a national standard of length. The combined standard uncertainty for a refractive index measured with the e-line (546 nm) of a Hg lamp is .- 24 April 2014
- Published by Optica Publishing Group in Applied Optics
- Vol. 53 (13) , 2793-2801
Prism-pair interferometer for precise measurement of the refractive index of optical glass by using a spectrum lamp
A prism-pair interferometer for a spectrum lamp was developed for precise measurement of the refractive index of a prism of optical glass. Previously we reported the prism-pair interferometer with a He–Ne laser light source, resulting in a measurement uncertainty of . However, most of the refractive-index values managed by optical glass manufacturers are conventionally measured with spectrum lamps. We have optimized the prism-pair interferometer for spectrum lamps and implemented a signal-processing technique from Fourier-transform spectroscopy. When the refractive index is measured, the wavelength of the spectrum lamp is simultaneously calibrated by part of the interferometer, so that the resulting refractive index is traceable to a national standard of length. The combined standard uncertainty for a refractive index measured with the e-line (546 nm) of a Hg lamp is .- 16 March 2012
- Published by IOP Publishing in Metrologia
- Vol. 49 (3)
A bilateral comparison of optical glass refractive index between NMIJ and INRiM for the validation of the measuring systems
- 16 March 2012
- Published by IOP Publishing in Metrologia
- Vol. 49 (3)
A bilateral comparison of optical glass refractive index between NMIJ and INRiM for the validation of the measuring systems
- 9 March 2011
- Published by Optica Publishing Group in Applied Optics
- Vol. 50 (8) , 1190-1196
Prism-pair interferometry by homodyne interferometers with a common light source for high-accuracy measurement of the absolute refractive index of glasses.
A prism-pair interferometer comprising two homodyne interferometers with a common light source was developed for high-precision measurements of the refractive index of optical glasses with an uncertainty of the order of . The two interferometers measure changes in the optical path length in the glass sample and in air, respectively. Uncertainties in the absolute wavelength of the common light source are cancelled out by calculating a ratio between the results from the interferometers. Uncertainties in phase measurement are suppressed by a quadrature detection system. The combined standard uncertainty of the developed system is evaluated as .- 9 March 2011
- Published by Optica Publishing Group in Applied Optics
- Vol. 50 (8) , 1190-1196
Prism-pair interferometry by homodyne interferometers with a common light source for high-accuracy measurement of the absolute refractive index of glasses.
A prism-pair interferometer comprising two homodyne interferometers with a common light source was developed for high-precision measurements of the refractive index of optical glasses with an uncertainty of the order of . The two interferometers measure changes in the optical path length in the glass sample and in air, respectively. Uncertainties in the absolute wavelength of the common light source are cancelled out by calculating a ratio between the results from the interferometers. Uncertainties in phase measurement are suppressed by a quadrature detection system. The combined standard uncertainty of the developed system is evaluated as .- 1 January 2010
- Published by Optica Publishing Group
- p. CTuOO4
Prism-pair Interferometer for Precise Refractive Index Measurement using Spectral Lamp Radiation with Simultaneous Wavelength Calibration
We developed a prism-pair interferometer which measures precise refractive index of glasses while ensuring the SI-traceability of a lamp wavelength. The measurement result agrees with manufacture’s value within 1×10-5.
- 1 January 2010
- Published by Optica Publishing Group
- p. CTuOO4
Prism-pair Interferometer for Precise Refractive Index Measurement using Spectral Lamp Radiation with Simultaneous Wavelength Calibration
We developed a prism-pair interferometer which measures precise refractive index of glasses while ensuring the SI-traceability of a lamp wavelength. The measurement result agrees with manufacture’s value within 1×10-5.