Jorge Manuel De Nicolás-Jiménez
Research Subjects
Jorge Manuel De Nicolás-Jiménez has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Ana González García
Adult Congenital Heart Disease Unit, Department of Cardiology, Hospital Universitario La Paz, Madrid, Spain
2 shared publications - Jesús González de Buitrago Amigo
Servicio de Pediatría, Hospital San Pedro de Alcántara, Cáceres, España
2 shared publications - Marta Ferrer Lozano
Pediatric Endocrinology Unit, Miguel Servet Children's University Hospital, Zaragoza, Spain
2 shared publications María Luz Tejado Bravo
Servicio de Pediatría, Hospital San Pedro de Alcántara, Cáceres, España
2 shared publicationsMercedes Fernández Llamas
Servicio de Pediatría, Hospital San Pedro de Alcántara, Cáceres, España
2 shared publicationsPaula Díaz Fernández
Servicio de Pediatría, Hospital Virgen del Puerto, Plasencia, Spain
2 shared publications
Latest Publications
- Open Access
- 1 November 2021
- Published by Elsevier in Anales de Pediatría (English Edition)
- Vol. 95 (5) , 321-329
The impact of “faster aspart” on blood glucose control in children and adolescents with type 1 diabetes treated using a sensor-augmented insulin pump
- 1 November 2021
- Published by Elsevier in Anales de Pediatría (English Edition)
- Vol. 95 (5) , 321-329
Open AccessThe impact of “faster aspart” on blood glucose control in children and adolescents with type 1 diabetes treated using a sensor-augmented insulin pump
- Open Access
- 1 November 2021
- Published by Elsevier in Anales de Pediatría
- Vol. 95 (5) , 321-329
Impacto de faster aspart sobre el control glucémico en niños y adolescentes con diabetes tipo 1 en tratamiento con un sistema integrado
- 1 November 2021
- Published by Elsevier in Anales de Pediatría
- Vol. 95 (5) , 321-329
Open AccessImpacto de faster aspart sobre el control glucémico en niños y adolescentes con diabetes tipo 1 en tratamiento con un sistema integrado
- Open Access
- 1 October 2019
- Published by Wolters Kluwer Health in Journal of Nursing Research
- Vol. 27 (5) , e46
Effects of Smoking and Physical Activity on the Pulmonary Function of Young University Nursing Students in Cáceres (Spain)
Background: The simultaneous effect of physical activity (PA) and smoking on pulmonary function in young people remains unclear. Propose: The aim of this study was to determine the influence of smoking and PA on pulmonary function in young university students in Cáceres, Spain. Methods: A sample of 120 young nursing students was studied (60 smokers and 60 nonsmokers). All subjects underwent spirometry with a COPD-6 portable device, and their level of PA was quantified using the International Physical Activity Questionnaire. The influence of PA and smoking on pulmonary function was determined by comparing hypotheses. Results: Significant differences were observed between smokers and nonsmokers in terms of percent forced expiratory volume in 1 second, percent forced expiratory volume in 6 seconds, lung age, and the difference between lung age and chronological age (LA–CA) in those who practiced mild PA. In the subjects who performed moderate and vigorous PA, these differences were not noted. In the intragroup analysis, significant differences were observed in smokers in terms of percent forced expiratory volume in 1 second, percent forced expiratory volume in 6 seconds, lung age, and LA–CA; however, in the control group, differences were only observed in terms of lung age and LA–CA. These findings were confirmed in the multivariate analysis. Conclusions/Implications for Practice: Our findings confirmed a deterioration in pulmonary function in smokers who did not perform moderate or vigorous PA. The level of PA performed was positively related to pulmonary function in smokers, whereas in nonsmokers, improvements were only significant in LA–CA.
- 1 October 2019
- Published by Wolters Kluwer Health in Journal of Nursing Research
- Vol. 27 (5) , e46
Open AccessEffects of Smoking and Physical Activity on the Pulmonary Function of Young University Nursing Students in Cáceres (Spain)
Background: The simultaneous effect of physical activity (PA) and smoking on pulmonary function in young people remains unclear. Propose: The aim of this study was to determine the influence of smoking and PA on pulmonary function in young university students in Cáceres, Spain. Methods: A sample of 120 young nursing students was studied (60 smokers and 60 nonsmokers). All subjects underwent spirometry with a COPD-6 portable device, and their level of PA was quantified using the International Physical Activity Questionnaire. The influence of PA and smoking on pulmonary function was determined by comparing hypotheses. Results: Significant differences were observed between smokers and nonsmokers in terms of percent forced expiratory volume in 1 second, percent forced expiratory volume in 6 seconds, lung age, and the difference between lung age and chronological age (LA–CA) in those who practiced mild PA. In the subjects who performed moderate and vigorous PA, these differences were not noted. In the intragroup analysis, significant differences were observed in smokers in terms of percent forced expiratory volume in 1 second, percent forced expiratory volume in 6 seconds, lung age, and LA–CA; however, in the control group, differences were only observed in terms of lung age and LA–CA. These findings were confirmed in the multivariate analysis. Conclusions/Implications for Practice: Our findings confirmed a deterioration in pulmonary function in smokers who did not perform moderate or vigorous PA. The level of PA performed was positively related to pulmonary function in smokers, whereas in nonsmokers, improvements were only significant in LA–CA.
- Open Access
- 1 November 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (11) , e0206434
Automatic or manual arterial path for the ankle-brachial differences pulse wave velocity
An automated method for measuring arterial path length with devices that determine pulse wave velocity (PWV) in peripheral arteries is frequently applied. We aimed to compare arterial path length measurements based on mathematical height-based formulas with those measured manually and to assess whether the ankle-brachial difference (abD-PWV) measured with the VOPITB device is comparable to that obtained by manual measurements. In 245 patients, a metric measuring tape was used to determine the arterial path length from the suprasternal notch to the midpoint of the VOPITB cuffs wrapped around the extremities, and the results were compared with those obtained with height-based formulas. We examined the relationship between the abD-PWV measured with both methods. The arterial path length measured manually was shorter than that calculated automatically by 5 ± 2 and 30 ± 4 cm—of 13% and 21% for the arms and legs, respectively (difference of 13% and 21%). As a result, the abD-PWV calculated with the automatic method was greater (automatic abD-PWV vs. manual: 462 ± 90 vs. 346 ± 79 cm/s). The Blant Altman plot showed a percentage error of: 15,2%, 7,5% and 17,3% for heart-brachial, heart-ankle length and abD-PWV respectively. In conclusion there were significant differences between manual and automated arterial length measurements and it translates into difference abD-PWV calculate from both methods. However, the Bland-Alman plot showed that abD-PWV was comparable for both techniques. The advantages of height-based formulas for the calculation of arterial path lengths suggest that they may be the recommended method for measuring the abD-PWV.
- 1 November 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (11) , e0206434
Open AccessAutomatic or manual arterial path for the ankle-brachial differences pulse wave velocity
An automated method for measuring arterial path length with devices that determine pulse wave velocity (PWV) in peripheral arteries is frequently applied. We aimed to compare arterial path length measurements based on mathematical height-based formulas with those measured manually and to assess whether the ankle-brachial difference (abD-PWV) measured with the VOPITB device is comparable to that obtained by manual measurements. In 245 patients, a metric measuring tape was used to determine the arterial path length from the suprasternal notch to the midpoint of the VOPITB cuffs wrapped around the extremities, and the results were compared with those obtained with height-based formulas. We examined the relationship between the abD-PWV measured with both methods. The arterial path length measured manually was shorter than that calculated automatically by 5 ± 2 and 30 ± 4 cm—of 13% and 21% for the arms and legs, respectively (difference of 13% and 21%). As a result, the abD-PWV calculated with the automatic method was greater (automatic abD-PWV vs. manual: 462 ± 90 vs. 346 ± 79 cm/s). The Blant Altman plot showed a percentage error of: 15,2%, 7,5% and 17,3% for heart-brachial, heart-ankle length and abD-PWV respectively. In conclusion there were significant differences between manual and automated arterial length measurements and it translates into difference abD-PWV calculate from both methods. However, the Bland-Alman plot showed that abD-PWV was comparable for both techniques. The advantages of height-based formulas for the calculation of arterial path lengths suggest that they may be the recommended method for measuring the abD-PWV.
- 1 May 2016
- Published by Elsevier in Revista Clínica Española (English Edition)
- Vol. 216 (4) , 191-197
Pulse wave velocity of the leg minus that of the arm measured with a custom device correlates to the coronary calcium quantification
- 1 May 2016
- Published by Elsevier in Revista Clínica Española (English Edition)
- Vol. 216 (4) , 191-197
Pulse wave velocity of the leg minus that of the arm measured with a custom device correlates to the coronary calcium quantification