Gyuyoung Yoon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gyuyoung Yoon has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
Masaya Okumiya
13 shared publicationsYuka Sakai
4 shared publicationsSatoru Iizuka
Assoc. Prof., Graduate School of Environmental Studies, Nagoya Univ., Dr.Eng
3 shared publicationsSaya Yoshioka
Nagoya City University, Aichi, Japan
3 shared publicationsTakeshi Watanabe
3 shared publicationsAndreas Athienitis
2 shared publications
Latest Publications
- 31 December 2025
- Published by Korean Society of Public Health Nursing in Journal of Korean Public Health Nursing
- Vol. 39 (3) , 443-458
Psychometric Evaluation of the Korean Adaptation of the Disaster Preparedness Awareness Scale
- 31 December 2025
- Published by Korean Society of Public Health Nursing in Journal of Korean Public Health Nursing
- Vol. 39 (3) , 443-458
Psychometric Evaluation of the Korean Adaptation of the Disaster Preparedness Awareness Scale
- 23 November 2025
- Published by Springer Nature
- p. 792-800
The Feasibility Study on the Hollow Fiber Membrane Dehumidification System Coupling with Conventional Air Conditioning System
- 23 November 2025
- Published by Springer Nature
- p. 792-800
The Feasibility Study on the Hollow Fiber Membrane Dehumidification System Coupling with Conventional Air Conditioning System
- 16 April 2024
- Published by Elsevier in Energy and Buildings
- Vol. 312
Energy savings evaluation of enhanced classroom daylighting utilization
- 16 April 2024
- Published by Elsevier in Energy and Buildings
- Vol. 312
Energy savings evaluation of enhanced classroom daylighting utilization
- 23 January 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 84
Field experiment on performance of water source heat pump using underground rainwater tank as heat source
- 23 January 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 84
Field experiment on performance of water source heat pump using underground rainwater tank as heat source
- Open Access
- 16 June 2023
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 396, 03012
A study on dedicated outdoor air handling unit systems regarding the widespread of ZEB
ZEB has been promoted in the building sector to realize energy conservation and carbon neutrality. This has caused changes such as a decrease in the room sensible heat load factor and an increase in the outdoor air load ratio. In this study, the systems with a dedicated outdoor air handling unit (OAHU) are evaluated as air conditioning systems that can flexibly respond to a changing heat load, and guidelines for rational design and operation are given. A case study is conducted to evaluate the indoor environment and energy performance of a conventional air handling unit (AHU) system and an OAHU system under the assumption of a reduction in internal heat gain intensity. The study results showed that the OAHU processed latent heat and reduced the number of uncomfortable hours by 78% compared to those for the AHU system during the cooling season for cases with reduced internal heat gain. Regarding system energy consumption, the OAHU system consumed 17% more energy than the AHU-system. Thus, the OAHU system maintained a better indoor environment than the AHU system at the cost of increased energy use. Based on these results, measures for reducing the energy consumption of the OAHU system are discussed.
- 16 June 2023
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 396, 03012
Open AccessA study on dedicated outdoor air handling unit systems regarding the widespread of ZEB
ZEB has been promoted in the building sector to realize energy conservation and carbon neutrality. This has caused changes such as a decrease in the room sensible heat load factor and an increase in the outdoor air load ratio. In this study, the systems with a dedicated outdoor air handling unit (OAHU) are evaluated as air conditioning systems that can flexibly respond to a changing heat load, and guidelines for rational design and operation are given. A case study is conducted to evaluate the indoor environment and energy performance of a conventional air handling unit (AHU) system and an OAHU system under the assumption of a reduction in internal heat gain intensity. The study results showed that the OAHU processed latent heat and reduced the number of uncomfortable hours by 78% compared to those for the AHU system during the cooling season for cases with reduced internal heat gain. Regarding system energy consumption, the OAHU system consumed 17% more energy than the AHU-system. Thus, the OAHU system maintained a better indoor environment than the AHU system at the cost of increased energy use. Based on these results, measures for reducing the energy consumption of the OAHU system are discussed.
- Open Access
- 16 June 2023
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 396, 03021
Fundamental Study on System Efficiency of Vacuum-based Membrane Dehumidification System
In recent years, the sensible heat load of buildings has been decreasing due to the promotion of energy conservation, and the sensible heat factor is expected to decrease. In response, the conventional dehumidification method using overcooled condensation is likely insufficient to handle latent heat, and an advanced dehumidification method is required. The authors have focused these issues and development on a dehumidification method using membranes. Membrane dehumidification systems (MDS) are relatively simple, then it is expected to be next-generation dehumidification system. Therefore, to evaluate the energysaving performance of MDS, this study developed an energy consumption balance equation for a system that uses overcooled & reheating and MDS, and verified energy-saving performance under different conditions. The results of the study quantitatively showed the system efficiency (Specific energy consumption, vacuum pump consumption per unit of dehumidification) of MDS, which is the amount of energy saved by MDS compared to the conventional system under the specified COP of the cooled heat source equipment and reheating equipment. The system efficiency at which MDS is superior under different room sensible heat factors and membrane utilization methods are also clarified. This enables determining the required system efficiency when considering the introduction of a MDS, and understanding the conditions for introducing a system in which MDS is competitive.
- 16 June 2023
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 396, 03021
Open AccessFundamental Study on System Efficiency of Vacuum-based Membrane Dehumidification System
In recent years, the sensible heat load of buildings has been decreasing due to the promotion of energy conservation, and the sensible heat factor is expected to decrease. In response, the conventional dehumidification method using overcooled condensation is likely insufficient to handle latent heat, and an advanced dehumidification method is required. The authors have focused these issues and development on a dehumidification method using membranes. Membrane dehumidification systems (MDS) are relatively simple, then it is expected to be next-generation dehumidification system. Therefore, to evaluate the energysaving performance of MDS, this study developed an energy consumption balance equation for a system that uses overcooled & reheating and MDS, and verified energy-saving performance under different conditions. The results of the study quantitatively showed the system efficiency (Specific energy consumption, vacuum pump consumption per unit of dehumidification) of MDS, which is the amount of energy saved by MDS compared to the conventional system under the specified COP of the cooled heat source equipment and reheating equipment. The system efficiency at which MDS is superior under different room sensible heat factors and membrane utilization methods are also clarified. This enables determining the required system efficiency when considering the introduction of a MDS, and understanding the conditions for introducing a system in which MDS is competitive.
- Open Access
- 16 June 2023
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 396, 03011
Strategic schematic design process for realization of ultra-low-carbon buildings
The goal of the present research is to support decision-making in the schematic design phase for the realization of ultra-low-carbon buildings by improving the design procedures. Therefore, this research attempts to build an energy model that allows the designer to determine the equipment and specifications based on energy performance at the schematic design stage. Based on the schematic design outline, the present paper investigates whether the numerical targets that represent the energy performance of the building and the evaluation indexes that can be used at the schematic design stage are examined. In addition, recent system trends, decision specifications, and functions are investigated at the schematic design stage for each equipment item, thereby clarifying the decision level.
- 16 June 2023
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 396, 03011
Open AccessStrategic schematic design process for realization of ultra-low-carbon buildings
The goal of the present research is to support decision-making in the schematic design phase for the realization of ultra-low-carbon buildings by improving the design procedures. Therefore, this research attempts to build an energy model that allows the designer to determine the equipment and specifications based on energy performance at the schematic design stage. Based on the schematic design outline, the present paper investigates whether the numerical targets that represent the energy performance of the building and the evaluation indexes that can be used at the schematic design stage are examined. In addition, recent system trends, decision specifications, and functions are investigated at the schematic design stage for each equipment item, thereby clarifying the decision level.
- Open Access
- 9 September 2022
- Published by Wiley in JAPAN ARCHITECTURAL REVIEW
- Vol. 5 (4) , 609-620
Energy savings for a junior high school classroom that actively uses daylighting and sensitivity study on the effect of the building envelope thermal performance
This paper analyzes the energy‐saving potential of lighting, including its effect on heating and cooling, and analyzes the effect of the thermal performance of a building on the annual energy consumption of a classroom actively using daylighting. The subject of this study is M Junior High School, located in Gifu, Japan. This school has a classroom design with a sloping roof, allowing the installation of large windows from north to south. The window‐to‐wall ratio of 56% for the south wall and 41% for the north wall takes advantage of daylight. Simulation results of illuminance in the classroom were validated through comparison with field measurement data. The result demonstrated that daylight utilization decreases lighting electric power consumption by 66.6% when artificial lighting is controlled in the classroom. The results confirmed that there was no significant heat load increase for heating and cooling even though the window surface area was larger than that of a typical classroom. The sensitivity study showed that the thermal performance of the building envelope mainly affects the heating energy consumption, but it has no significant effect on cooling and lighting energy consumption. In terms of the thermal performance of the building envelope and the amount of energy saving by daylight utilization, it is necessary to consider the appropriate thermal performance to determine cost‐effectiveness.
- 9 September 2022
- Published by Wiley in JAPAN ARCHITECTURAL REVIEW
- Vol. 5 (4) , 609-620
Open AccessEnergy savings for a junior high school classroom that actively uses daylighting and sensitivity study on the effect of the building envelope thermal performance
This paper analyzes the energy‐saving potential of lighting, including its effect on heating and cooling, and analyzes the effect of the thermal performance of a building on the annual energy consumption of a classroom actively using daylighting. The subject of this study is M Junior High School, located in Gifu, Japan. This school has a classroom design with a sloping roof, allowing the installation of large windows from north to south. The window‐to‐wall ratio of 56% for the south wall and 41% for the north wall takes advantage of daylight. Simulation results of illuminance in the classroom were validated through comparison with field measurement data. The result demonstrated that daylight utilization decreases lighting electric power consumption by 66.6% when artificial lighting is controlled in the classroom. The results confirmed that there was no significant heat load increase for heating and cooling even though the window surface area was larger than that of a typical classroom. The sensitivity study showed that the thermal performance of the building envelope mainly affects the heating energy consumption, but it has no significant effect on cooling and lighting energy consumption. In terms of the thermal performance of the building envelope and the amount of energy saving by daylight utilization, it is necessary to consider the appropriate thermal performance to determine cost‐effectiveness.
- 1 December 2021
- Published by Elsevier in Energy Policy
- Vol. 159
Policy recommendations for the zero energy building promotion towards carbon neutral in Asia-Pacific Region
- 1 December 2021
- Published by Elsevier in Energy Policy
- Vol. 159
Policy recommendations for the zero energy building promotion towards carbon neutral in Asia-Pacific Region