Anıl Özyurt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Anıl Özyurt has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Abdurrahman Galayene
Faculty of Dentistry, Department of Oral and Maxillofacial Surgery, Van Yüzüncü Yıl University, Van, Türkiye
1 shared publication - Ahmet Asan
Trakya Universitesi
1 shared publication - Bülent Altunkaynak
Faculty of Science, Department of Statistics, Gazi University, Ankara, Turkey
1 shared publication Cemile Merve Seymen
Research Assistant, Department of Histology and Embryology, Faculty of Medicine, Gazi University, Ankara, Turkey
1 shared publication- Erkan Çırak
Ballıpınar Dental Polyclinic, Afyon, Turkey
1 shared publication Fatih Üstel
Faculty of Engineering Department of Metallurgical and Materials Engineering Sakarya University Sakarya TURKEY
1 shared publication
Latest Publications
- 20 May 2026
- Published by Academician Publishing
- p. 95-108
Preoperatif Planlama: Komşu Dış, Inferior Alveolar Kanal, Sinüs ve Yumuşak Doku İlişkileri
- 20 May 2026
- Published by Academician Publishing
- p. 95-108
Preoperatif Planlama: Komşu Dış, Inferior Alveolar Kanal, Sinüs ve Yumuşak Doku İlişkileri
- Open Access
- 16 October 2023
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 34 (11) , 1-7
Evaluation of the effects of silk and polyethylene terephthalate sutures on postoperative complications in impacted lower third molar surgery
The aim of this study was to compare the efficacy of silk and Polyethylene Terephthalate (PET) sutures on postoperative complications in impacted lower third molar surgery. This prospective, randomized, split-mouth, double-blind clinical study was performed between January 2021 and June 2022 at the Faculty of Dentistry, Department of Oral and Maxillofacial Surgery, Van Yüzüncü Yıl University. The patients were categorized into two groups in terms of using suture material. PET suture was used in Group 1, and the silk suture in Group 2 for wound closure following impacted lower third molar surgery. The statistical significance level was accepted as p < 0.05 in the study. Forty patients (21 women, 19 men; mean age: 26.1 ± 7.25 years) were included in the study. When values for swelling and trismus evaluation were analyzed, there was no significant intergroup difference (p > 0.05). However, the VAS values of the silk group patients were higher at the 12th and 24th hours (p < 0.05). In addition, the plaque accumulation value in the silk group was higher than that in the PET group on the second postoperative day (p < 0.05). The results indicated that the plaque accumulation in the PET suture was less on the second postoperative day. Also, PET suture group patients felt less pain during the 12th and 24th hours. These results support to use PET sutures in impacted lower third molar surgery. Graphical Abstract
- 16 October 2023
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 34 (11) , 1-7
Open AccessEvaluation of the effects of silk and polyethylene terephthalate sutures on postoperative complications in impacted lower third molar surgery
The aim of this study was to compare the efficacy of silk and Polyethylene Terephthalate (PET) sutures on postoperative complications in impacted lower third molar surgery. This prospective, randomized, split-mouth, double-blind clinical study was performed between January 2021 and June 2022 at the Faculty of Dentistry, Department of Oral and Maxillofacial Surgery, Van Yüzüncü Yıl University. The patients were categorized into two groups in terms of using suture material. PET suture was used in Group 1, and the silk suture in Group 2 for wound closure following impacted lower third molar surgery. The statistical significance level was accepted as p < 0.05 in the study. Forty patients (21 women, 19 men; mean age: 26.1 ± 7.25 years) were included in the study. When values for swelling and trismus evaluation were analyzed, there was no significant intergroup difference (p > 0.05). However, the VAS values of the silk group patients were higher at the 12th and 24th hours (p < 0.05). In addition, the plaque accumulation value in the silk group was higher than that in the PET group on the second postoperative day (p < 0.05). The results indicated that the plaque accumulation in the PET suture was less on the second postoperative day. Also, PET suture group patients felt less pain during the 12th and 24th hours. These results support to use PET sutures in impacted lower third molar surgery. Graphical Abstract
- Open Access
- 15 July 2022
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 33 (7) , 1-7
Does hyperbaric oxygen therapy pressure reduce mechanical stability of implants?
Hyperbaric oxygen therapy (HBOT) has beneficial effects for patients complaining of poor bone healing such as related to diabetes mellitus. However, it is known that changing pressure conditions might cause dental barotrauma in the oral cavity. The aim of this study was to evaluate implant mechanical stability under HBOT pressure. Thirty-five implants were placed in bone blocks divided into five groups as control, 1, 3, 5, 7 HBOT cycles. In one cycle, 2.4 bar 100% oxygen pressure was performed. Implants’ stabilities were measured with resonance frequency analysis (RFA) and removal torque (RT) meter device. Data were analyzed using Shapiro Wilk, ANOVA, and Tukey HSD tests for RFA and RT values considering p < 0.05 as the statistical significance level. RFA and RT values were compared by Pearson correlation coefficiency. RFA values of 5 and 7 HBOT cycles were significantly lower than 1, 3 HBOT and control group (p < 0.001). There was no statistical difference between 5 and 7 HBOT cycles RFA values. HBOT pressure simulation slightly but statistically decreased the stability for the implants exposed to 5 and 7 HBOT cycles.
- 15 July 2022
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 33 (7) , 1-7
Open AccessDoes hyperbaric oxygen therapy pressure reduce mechanical stability of implants?
Hyperbaric oxygen therapy (HBOT) has beneficial effects for patients complaining of poor bone healing such as related to diabetes mellitus. However, it is known that changing pressure conditions might cause dental barotrauma in the oral cavity. The aim of this study was to evaluate implant mechanical stability under HBOT pressure. Thirty-five implants were placed in bone blocks divided into five groups as control, 1, 3, 5, 7 HBOT cycles. In one cycle, 2.4 bar 100% oxygen pressure was performed. Implants’ stabilities were measured with resonance frequency analysis (RFA) and removal torque (RT) meter device. Data were analyzed using Shapiro Wilk, ANOVA, and Tukey HSD tests for RFA and RT values considering p < 0.05 as the statistical significance level. RFA and RT values were compared by Pearson correlation coefficiency. RFA values of 5 and 7 HBOT cycles were significantly lower than 1, 3 HBOT and control group (p < 0.001). There was no statistical difference between 5 and 7 HBOT cycles RFA values. HBOT pressure simulation slightly but statistically decreased the stability for the implants exposed to 5 and 7 HBOT cycles.
- 4 April 2021
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 23 (3) , 417-422
Investigation of implant internal screw loosening under hyperbaric conditions: An in vitro study
Background and purpose The internal screw has an essential role in carrying abutment and prosthesis loading. Some dental implant patients such as scuba divers, mineworkers, and hyperbaric oxygen patients are exposed to hyperbaric atmospheres. The aim of this study was to investigate internal screw loosening under hyperbaric conditions. Materials and methods Forty‐two dental implants were placed into plexiglass blocks. Abutments were fixed with internal screws by 25 Ncm torque force. Groups were set as control, 2.8‐bar air pressure, and 4‐bar air pressure groups. Hyperbaric groups were subdivided and exposed to either one or six cycles. Removal torque values were measured with a digital torque meter. Data were analyzed statistically using analysis of variance and Tamhane's T2 tests, considering p < 0.05 as the level of statistical significance. Internal screw threads were qualitatively observed under magnification. Results Four‐bar groups showed the lowest removal torque values among all groups (p < 0.001). 2.8‐Bar groups did not show significant differences compared with control groups. There was no statistically significant difference between the one and six pressure cycle subgroups in each group. All internal screw threads had various deformations. Conclusion Four‐bar air pressure had a significant effect on internal screw loosening. Internal screw tightening protocols should be reconsidered for patients exposed to advanced hyperbaric conditions.
- 4 April 2021
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 23 (3) , 417-422
Investigation of implant internal screw loosening under hyperbaric conditions: An in vitro study
Background and purpose The internal screw has an essential role in carrying abutment and prosthesis loading. Some dental implant patients such as scuba divers, mineworkers, and hyperbaric oxygen patients are exposed to hyperbaric atmospheres. The aim of this study was to investigate internal screw loosening under hyperbaric conditions. Materials and methods Forty‐two dental implants were placed into plexiglass blocks. Abutments were fixed with internal screws by 25 Ncm torque force. Groups were set as control, 2.8‐bar air pressure, and 4‐bar air pressure groups. Hyperbaric groups were subdivided and exposed to either one or six cycles. Removal torque values were measured with a digital torque meter. Data were analyzed statistically using analysis of variance and Tamhane's T2 tests, considering p < 0.05 as the level of statistical significance. Internal screw threads were qualitatively observed under magnification. Results Four‐bar groups showed the lowest removal torque values among all groups (p < 0.001). 2.8‐Bar groups did not show significant differences compared with control groups. There was no statistically significant difference between the one and six pressure cycle subgroups in each group. All internal screw threads had various deformations. Conclusion Four‐bar air pressure had a significant effect on internal screw loosening. Internal screw tightening protocols should be reconsidered for patients exposed to advanced hyperbaric conditions.
- Open Access
- 31 December 2020
- Published by Istanbul University in İstanbul Journal of Pharmacy
- Vol. 50 (3) , 216-223
Effect of gel formulation obtained from Fomes fomentarius on bleeding and clotting time: A pilot study
İstanbul Üniversitesi Yayın Projesi
- 31 December 2020
- Published by Istanbul University in İstanbul Journal of Pharmacy
- Vol. 50 (3) , 216-223
Open AccessEffect of gel formulation obtained from Fomes fomentarius on bleeding and clotting time: A pilot study
İstanbul Üniversitesi Yayın Projesi
- Open Access
- 1 January 2020
- Published by Turkiye Klinikleri in Turkiye Klinikleri Journal of Dental Sciences
- Vol. 26 (3) , 331-347
Evaluation of the Resistance and Bioactivity of Wollastonite and Hydroxyapatite Coated Zirconia Dental Implant Material
Objective: Zirconia dental implants are an alternative to titanium. Various studies have been carried out in order to improve the surface properties of zirconia implants like titanium implants. The aim of this study is to evaluate the resistance and bioactivity of zirconia dental implant materials coated with different ratios of hydroxyapatite and wollastonite powders by plasma spray method. Material and Methods: The bond strength between the zirconia and the coatings was measured according to the ASTM C-633 standard. The data were obtained by using one-way analysis of variance. Differences between the groups were determined by Post Hoc Tukey HSD test. Examples prepared for bioactivity testing were kept in 37 oC simulated body fluid for 2, 7, 14- and 21-day periods. Changes in the sample surfaces were analyzed by scanning electron microscopy using energy distribution x-ray spectrometry and x-ray diffraction device. Result: Bonding values of coatings containing different ratios of W were found to be significantly higher than pure HA coatings (p<0.05). Conclusion: All sample groups used in the study showed bioactive properties in simulated body fluid.
- 1 January 2020
- Published by Turkiye Klinikleri in Turkiye Klinikleri Journal of Dental Sciences
- Vol. 26 (3) , 331-347
Open AccessEvaluation of the Resistance and Bioactivity of Wollastonite and Hydroxyapatite Coated Zirconia Dental Implant Material
Objective: Zirconia dental implants are an alternative to titanium. Various studies have been carried out in order to improve the surface properties of zirconia implants like titanium implants. The aim of this study is to evaluate the resistance and bioactivity of zirconia dental implant materials coated with different ratios of hydroxyapatite and wollastonite powders by plasma spray method. Material and Methods: The bond strength between the zirconia and the coatings was measured according to the ASTM C-633 standard. The data were obtained by using one-way analysis of variance. Differences between the groups were determined by Post Hoc Tukey HSD test. Examples prepared for bioactivity testing were kept in 37 oC simulated body fluid for 2, 7, 14- and 21-day periods. Changes in the sample surfaces were analyzed by scanning electron microscopy using energy distribution x-ray spectrometry and x-ray diffraction device. Result: Bonding values of coatings containing different ratios of W were found to be significantly higher than pure HA coatings (p<0.05). Conclusion: All sample groups used in the study showed bioactive properties in simulated body fluid.
- 1 July 2018
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 46 (7) , 1147-1152
Comparative evaluation of various low-level laser therapies on bone healing following tooth extraction: An experimental animal study
- 1 July 2018
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 46 (7) , 1147-1152
Comparative evaluation of various low-level laser therapies on bone healing following tooth extraction: An experimental animal study
- 1 February 2018
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 76 (2) , 287.e1-287.e10
Effects of Low-Level Laser Therapy With a Herbal Extract on Alveolar Bone Healing
- 1 February 2018
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 76 (2) , 287.e1-287.e10
Effects of Low-Level Laser Therapy With a Herbal Extract on Alveolar Bone Healing