CCCarsten Cremers

Carsten Cremers

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Carsten Cremers has a total of 225 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Investigation of the Effect of Ammonia As Ambient Air Contaminant on PEM Fuel Cell Stack Performance and Degradation Using EIS, Thda and Different Gas Analysis Methods

    by Tansu Özel, Stefan Bürger, Carsten Cremers

    The negative effects of airborne contaminants on polymer electrolyte membrane fuel cell (PEMFC) have already been shown in several publications. [1] Among these contaminants, ammonia (NH3) with its multistep reversible and irreversible effects is particularly significant. Recent studies on air quality in urban areas have revealed a notable increase in ammonia levels within a span of two years. [2] This rapid increase can be attributed to the growing prevalence of EURO-6 diesel vehicles equipped with selective catalytic reduction (SCR) cats, which results in ammonia slip during the nitrogen oxide reduction process in diesel engines. [2] Ambient air is the most common used oxidant gas in mobile and stationary PEM fuel cell systems. The performance of fuel cell can suffer beyond the oxygen gain from airborne contaminants, which also have the potential to accelerate degradation. To prevent that airborne contaminants reach the fuel cell cathode, air filter systems consisting of particle filter and specially for fuel cell requirements developed filter are installed at the cathode inlet. Despite the installation of an air filter system, airborne contaminants can still reach the fuel cell cathode. The focus of this investigation is on the effects of ammonia in PEM fuel cell stacks. In contrast to single cell operation, stack operation can introduce additional effects such as cell-to-cell inhomogeneities and varying degrees of ammonia-induced degradation among cells. For the investigation, experiments with a PEMFC stack are going to be done on a fuel cell testbed equipped with an impedance analyzer. Ammonia is going to be mixed into the cathode air in the ppb range. Its effects on PEMFC stack performance are going to be investigated with electrochemical impedance spectroscopy (EIS) and total harmonic distortion analysis (THDA). The cathode exhaust gas is also going to be analyzed by gas analyzers such as FTIR gas analyzer and mass spectrometry. It is planned to test the PEMFC stack under different operating conditions like temperature, relative humidity and pressure of inlet gases, with various parameters and different cathode gas mix ratios while monitoring possible conversion of impurities via FTIR and the stack state of health using THDA and conventional technologies to understand the link between the effect of ammonia on fuel cell stack performance, on its lifetime and to determine possible early indicators. References [1] Misz, U., Talke, A., Heinzel, A., and Konrad, G. 2016. Sensitivity Analyses on the Impact of Air Contaminants on Automotive Fuel Cells. Fuel Cells 16, 4, 444–462. [2] R. Wegener, U. Javed, R. Dubus, and D. Klemp. 2024. Investigations of Air Quality Aspects with the Urban Climate Model PALM4U.

  • Open Access

    A Dynamic Tanks-in-Series Model for a High-Temperature PEM Fuel Cell

    by Valery A. Danilov, Gunther Kolb, Carsten Cremers

    A dynamic tanks-in-series model has been developed for the coupled heat, mass, and charge transfer processes in a high-temperature proton exchange membrane fuel cell. The semi-empirical model includes the heat and mass balance equations in the gas channels and the membrane electrode assembly together with the charge balance at the electrode/membrane interfaces. The outputs of the tanks-in-series model are the concentration, the temperature, and the current density with a step change from tank to tank. The dynamic non-isothermal model is capable of predicting both the transient and steady-state behavior of the fuel cell and reproducing impedance data under harmonic perturbations of the cell potential together with a comprehensive interpretation of experimental data.

  • Investigation of the Effect of Graphite Bipolar Plate Flow Channel Inhomogeneities and Faults on HT-PEM Fuel Cell Stack Performance

    by Tansu Özel, Samuel Kraft, Carsten Cremers

    Bipolar plates are a key component of fuel cell stacks. Bipolar plates have multiple functions. They connect the single cells of the stack electrically and must be therefore electrically conductive. They separate oxidant and fuel gases and distribute them on each side over the membrane-electrode-assembly (MEA). Bipolar plates separate coolant liquid too. Fuel cell stack is cooled by coolant liquid which is flowing through the cooling flow channels in the middle of bipolar plates. Especially the bipolar plates for HT-PEM must endure a low pH environment, continuous electrical potential, and higher temperatures up to 200°C. The focus here is on investigations of anode and cathode side flow channels of graphite bipolar plates. Inhomogeneities and faults of flow channels are examined and their effects on fuel cell stack performance are analyzed. The analyses are based on optical scan data of flow channel geometry and measurement data of a HT-PEM fuel cell full stack consisting of 120 cells operated on a testbed under different variations. Inlet pressure and stoichiometry of both anode and cathode were varied, anode was fed with pure hydrogen and with different reformate gas compositions consisting of hydrogen, nitrogen, carbon dioxide and carbon monoxide. For each variation point, polarization curves between 0 A/cm2 – 0,55 A/cm2 in step of 0,05 A/cm2 were recorded. With an on testbed installed cell voltage monitoring (CVM) system voltages of every cell were measured and logged. Enormous amount of optical scan data consisting of width and depth information of flow channels was merged to certain statistical data for anode and cathode bipolar plates. Correlations between statistical data and cell voltages are still being investigated. It is planned to repeat the measurements with another 120 cells HT-PEM fuel cell full stack and compare the results.

  • Challenges of Using Fuel Cells to Deliver Aircraft Propulsion Power

    by Carsten Cremers

    Beside sustainable aviation fuels (SAFs), which offer an easy but expensive drop-in solution the use of hydrogen is discussed as an important way to decarbonise air traffic. According to a study performed by McKenzie on behalf of the “Fuel Cell and Hydrogen 2” and “Clean Sky 2” Joint undertakings hydrogen is the economical more viable option for small and medium range aircrafts1. For the smaller aircrafts electric propulsion using fuel cells to deliver the required electric power are the preferred choice from the economic perspective. Operating fuels cell on board of a flying aircraft is however not necessarily easy. An evident issue is the reduced air pressure at high altitudes. So, the barometric pressure at an altitude of 11,000 m is only 0.29 bar. Oxygen partial pressure is equally reduced to 61 mbar at constant oxygen concentration of 21 vol.%. In order to supply the stack either much higher flow rates are required at reduced pressures or a much higher compression. The former will create challenges regarding water management as a high gas flow in combination with reduced pressure accelerates the drying out of the membrane. Using HT-PEMFC instead would avoid the impact of water evaporation. However, the conditions are also likely to foster evaporation of phosphoric acid from the membrane electrode assembly. Here it will be investigate from published data if new HT-PEMFC membranes e.g. from Los Alamos National Laboratory2 would allow such a low pressure operation. Operating at high pressure will definitively challenge the system efficiency. Also, the characteristics of typical compressors render it difficult to achieve the required air compression rate of about 4.5 to increase pressure from 0.29 bar ambient to 1.3 bar stack pressure. This is, because during typical cruise operation power consumption and thus air need is strongly reduced. The variation of load and subsequently the likely variation of stack pressure can also cause challenges, in particular if after a period of low power requirements, a sudden increase in power demand needs to be answered. Such a situation will regularly be encountered for high load take off acceleration after taxying and potential waiting. Here hybridisation with a battery can be helpful to allow the fuel cell to power-up in time before take-off charging the battery used for electric taxying. More difficult is the irregular but for safety reason important situation of a go-around. During descend engines are typically operated at close to idle condition for a longer period of time. If no measures are taken to maintain stack temperature the temperature will reduce so that the immediate supply of power required for a go-around might not be available. Keeping the temperature at low load may however again cause dry-out or acid evaporation depending on whether the stack is LT- or HT-PEMFC based. In this contribution are more detailed analysis will be presented also striving to assign issues and their potential mitigation to component, stack or system level. Hydrogen-powered aviation: A fact-based study of hydrogen technology, economics, and climate impact by 205 0, Luxembourg, Publications Office of the European Union. K.-S. Lee, S. Maurya, Y. S. Kim, C. R. Kreller, M. S. Wilson, D. Larsen, S. E. Elangovan and R. Mukundan, Energy Environ. Sci., 11(4), 979–987 (2018).


  • Characterizing Reversible and Irreversible Degradation Effects of PEM Water Electrolyzer Stacks

    by Felix Dittmar, Stefan Bürger, Carsten Cremers

    Polymer electrolyte membrane water electrolyzers (PEMEL) have been identified as a key component in a decarbonized large-scale energy system, as they can produce high-purity hydrogen from renewable electricity sources for the chemical industry or energy storage. However, the long-term durability and performance of PEM electrolyzers remain a major challenge, with degradation being a critical factor that limits their lifespan and efficiency. Recent studies have focused on developing accelerated stress test (AST) protocols for PEM electrolyzers to better understand the conditions and mechanisms that lead to degradation.1, 2 Especially the reversible rise in cell potential, which in the literature is often regarded as apparent or reversible degradation, must be further investigated to find mitigation strategies for operation.3, 4 We present our research on the development of two testing protocols (static, dynamic) characterizing reversible and irreversible degradation effects for PEMEL stacks in different operation modes. Our aim is to gain a better understanding of the variance of these phenomena in general and the recovery of reversible effects across PEMEL stacks. The measurements are carried out on a commercialized Greenlight E400 test bench equipped with a 7kW 8 cell PEMEL stack (Hydrogen Innovation GmbH). The potential of all cells will be monitored during testing. The measurements include repeated electrochemical characterization protocols measuring i/E-curves, HFR and impedance spectroscopy (EIS) of the PEMEL stack and if possible, every single cell. These protocols include the introduction of low potential regeneration phases before every characterization during the test protocol to distinguish between reversible effects and the irreversible cell degradation. This was seen to be effective for potential recovery by Suermann et al. 2019 for single PEMEL cells.4 The results consist of a description of the two testing procedures and the used equipment. Due to the duration of each test protocol (3000 h) only results of the static test protocol can be presented. The contribution of the presented research is threefold. Firstly, we break down the degradation across a whole stack. Giving valuable insights regarding the distribution of cell efficiency and degradation effects. Secondly, the presented test protocols characterize and account for the reversible rise in cell/stack potential. Thirdly, the characterization of the recovery time of the cell potential across the stack will have implications for the operation of stacks to mitigate or recover these performance losses. We address both static and dynamic operation modes aiming to simulate the application of PEMEL stacks for a constant production of hydrogen used in downstream processes and the volatile operation due to a direct coupling with renewable energy sources. This publication is to be seen as presentation of first results in our ongoing research to find test protocols for short stack systems to develop operation strategies, which can be applied to large scale electrolyzer systems. Furthermore, we try to deepen the understanding of the reversible cell potential rise as well as standardize the general testing of PEMEL stacks. This work is funded by the Federal Ministry of Education and Research (BMBF) in the project “hyBit” under the grant 03SF0687E. The authors declare that the opinions expressed in this submission are their own and are based on a thorough review of existing scientific literature. Sources 1. G. Tsotridis and A. Pilenga, EU harmonized protocols for testing of low temperature water electrolysis, Publications Office of the European Union, Luxembourg (2021). 2. A. Voronova, H.-J. Kim, J. H. Jang, H.-Y. Park and B. Seo, International Journal of Energy Research, 46 (2022) 11867. 3. C. Rakousky, U. Reimer, K. Wippermann, S. Kuhri, M. Carmo, W. Lueke and D. Stolten, Journal of Power Sources, 342 (2017) 38. 4. M. Suermann, B. Bensmann and R. Hanke-Rauschenbach, Journal of The Electrochemical Society, 166 (2019) F645-F652.


  • Towards Reliable Stability Measurements of OER Catalysts

    by Aline Bornet, Simon Pitscheider, Erlend Bertheussen, Christoffer Mølleskov Pedersen, Annabelle Maletzko, Nedjeljko Seselj, Gustav Karl Henrik Wiberg, Christian Kallesøe, Julia Melke, Carsten Cremers, et al.

    Currently, significant efforts are taken to find the most active and stable electrochemical oxygen evolution reaction (OER) catalyst diverting from critical raw material. However, one also needs to consider new catalyst screening methods, especially with respect to stability investigations where rotating disk electrode (RDE) studies are not suitable.1 Recently, we introduced a gas diffusion electrode (GDE) setup as a new testing platform for OER catalysts.2 This methodology stems from fuel cell studies where carbon gas diffusion layer (GDL) is used as a transport layer to bring the reactant to the catalyst. Since carbon is not stable under the harsh OER conditions, water electrolyser uses titanium-based porous transport layers (PTLs). In the current work, we utilized the GDE setup to test the influence of the transport layer on the stability of a highly active Ir0.7Ru0.3Ox nanoparticle catalyst immobilized on homemade antimony-doped tin oxide (ATO) support. The test was conducted potentiostatically (@ 1.6 V vs RHE) for 2 h at 60 °C. The stability of the catalyst was then compared when deposited on GDL vs PTL. Rapid decline of the GDL-deposited catalyst activity was observed, while the PTL-deposited catalyst demonstrates a rather stable behavior (Fig. 1). We attribute this fast activity drop to the carbon oxidation of the GDL. Moreover, the activity at 30 °C of the PTL-deposited catalyst was compared to literature data on RDE setup [1]. In the RDE setup, a breakdown is observed after only 30 min when applying a constant current density. In contrast, PTL-deposited catalyst exhibits no activity loss during 2 h under similar conditions. [1] H. A. El-Sayed. Journal of The Electrochemical Society, 166 (8), F458-F464 (2019) [2] J. Schröder. JACS Au, 1, 247-251 (2021) Figure 1 . Potentiostatic stability transients at 1.6 V vs RHE of Ir0.7Ru0.3Ox/ATO deposited on C-based GDL (green full) and on Ti-based PTL at 60 °C (black full) and 30 °C (blue dashed). Figure 1

  • Relevance of GDL Properties Regarding GDL Quality Assurance

    by Carsten Cremers

    Gas diffusion layers are an important part of all types of polymer electrolyte membrane fuel cells (LT-PEMFC, HT-PEMFC or AEMFC). Albeit the conversion reaction is not taking place in the GDL the contributions of the GDL to the function of the cell are essential. So, the GDL needs to homogenise the distribution of reacting gases over the electrode area compensating inhomogeneities created by the channel fin structure of the flow-field of the bipolar plate and at the same time cause a focussing of product streams towards the channels. The GDL needs to conduct electric current between the catalyst layer and the bipolar plate at high current density and transport released thermal energy. The GDL also needs to distribute mechanical pressure of the stack compression. In order to accomplish all those tasks, the GDL needs to feature the right properties with high homogeneity through-out its area and with high reproducibility batch to batch. Unfortunately, a rather high number of properties can be assigned to a GDL. So, the review paper by Yuan et al. on properties for different LT-PEMFC components1 lists about 15 different properties for GDL which influence their function. As many of these properties are difficult to measure measuring all of them is not a viable approach to the quality assurance of GDL as part of their industrial production. Within the project QM-GDL Fraunhofer ICT together with the other partners of the project is analysing the relevance of the different properties, comparing the expected impact of deviation from the designed values and the effort, and determining the actual values. The goal is to determine the most relevant parameters which will allow to assure proper functioning of the GDL if their values are controlled keeping the effort for measurements at a reasonable value. In the presentation the approach for the selection of relevant parameters will be explained at a number of examples. Also, a tentative list of parameters will be presented and discussed. The presented work is part of the project QM-GDL which receives financial support by the German Federal Ministry of Digital Infrastructures and Traffic under Grant Agreement 03B11016E. The content of the presentation is in the sole responsibility of the author. X.-Z. Yuan, C. Nayoze-Coynel, N. Shaigan, D. Fisher, N. Zhao, N. Zamel, P. Gazdzicki, M. Ulsh, K. A. Friedrich, F. Girard and U. Groos, Journal of Power Sources, 491 (2021).

  • Design and Construction of a LT-PEM Fuel Cell System for Aviation Application

    by Stefan Bürger, Carsten Cremers, Niels Urban

    Fuel cell technology has gained considerable attention as an alternative power source for mobility applications. Fuel cell systems are already integrated in ground applications like trucks, cars, and busses. One reason is, that they have the potential to provide an environmentally friendly power supply solution compared to traditional combustion engines. Moreover, fuel cell drive trains offer several potential benefits, such as improved energy efficiency, noise reduction and no local emissions and even zero CO2 emission if they are fueled with green hydrogen. On the other hand, there are several key challenges associated with the integration of fuel cell technology into mobility applications, such as safety, durability, weight, and cost. These challenges become even more difficult when flight applications are considered, due to the higher . We present our research of a fuel cell system design, which is constructed to power a one seat airplane, the Antares E2. This system will utilize compressed Hydrogen as fuel to power up to six electronic motors via an electric bus. The airplane needs 90 kW of power mainly for its electric propulsion and can be operated up to a ceiling altitude of 6500 m (21,300 ft). For redundancy and safety, it is necessary to split the power output to at least two systems. Therefore, each system must have a power output of 45 kW. The fuel cell system's design takes various factors into account, such as lightweight and compact components as well as safety analysis to ensure the operation in flight. To reach aviation standards a full FMEA analysis is conducted, to calculate the risks of operating the systems on an airplane. The goal is to have a fuel cell system which is eligible for operating an aircraft. We want to present first results of our research, consisting of first design to ground operation and include some simulations for flight conditions. A successful development and certification of this fuel cell system would represent a significant milestone in the pursuit of sustainable aviation technologies, since it would be one of the first system which features approved airworthiness. This technology has the potential to reduce emissions and noise pollution associated with traditional combustion engines. Further research and development efforts are required to optimize the performance and reduce the cost of this fuel cell system. This work is funded by the Federal Ministry for Digital and Transport (BMDV) in the project “H2GA” under the grant 03B10707. The authors declare that the opinions expressed in this submission are their own and are based on a thorough review of existing scientific literature.

  • Investigation of the Effect of Airborne Contaminants on PEM Fuel Cell Stack Performance and Degradation Using Electrochemical Impedance Spectroscopy, AVL Thda™ and FTIR Gas Analyzer

    by Tansu Özel, Stefan Bürger, Carsten Cremers

    Air pollution is still a bitter truth in many locations in the world. In highly populated regions like metropolitan areas as well as in agricultural areas there are various airborne contaminants which can be harmful to organisms. Also fuel cells, especially PEMFC are sensitive to airborne contaminants. In most mobile and stationary PEM fuel cell systems, ambient air is used as oxidant gas at the cathode of the fuel cell. It is cost and weight saving because there is no need to install additional tank for pure oxygen and to refill it, but the performance of fuel cell can suffer beyond the oxygen gain from airborne contaminants, which also have the potential to accelerate degradation. To prevent that airborne contaminants reach the fuel cell cathode, air filter systems consisting of particle filter and additional activated carbon filter are installed at the cathode inlet. The focus here is on the investigation of the use of AVL THDAtm method to detect effects of airborne contaminants. THDA (total harmonic distortion analysis) is a patented online fuel cell monitoring method based on analyzing harmonic distortion effects of voltage drifts instead of single cell voltage measurement. So far it was successfully demonstrated for the detection of water issues like flooding and drying, and for low media supply issues on both cathode and anode side [1, 2]. For the development and validation of the method, experiments with a PEMFC stack are going to be done on a fuel cell testbed equipped with an AVL X-Ion impedance analyzer. Specific air pollutant gases ammonia (NH3), sulfur dioxide (SO2) and nitrogen oxides (NOx) are going to be mixed into the cathode air in the ppb range. Their effects on PEMFC stack performance are going to be investigated with electrochemical impedance spectroscopy (EIS) and total harmonic distortion analysis. The cathode exhaust gas is also going to be analyzed by an FTIR gas analyzer. It is planned to test the PEMFC stack under different operating conditions, with various parameters and different cathode gas mix ratios while monitoring possible conversion of impurities via FTIR and the stack state of health using THDA and conventional technologies to understand the link between the effect of airborne contaminants on fuel cell stack performance, on its lifetime and to determine possible early indicators in the THDA signals. References [1] Mitzel, J., Sanchez‐Monreal, J., Garcia‐Sanchez, D., Gazdzicki, P., Schulze, M., Häußler, F., Hunger, J., Schlumberger, G., Janicka, E., Mielniczek, M., and Gawel, L. 2020. Fault Diagnostics in PEMFC Stacks by Evaluation of Local Performance and Cell Impedance Analysis. Fuel Cells 20, 4, 403–412. [2] Ramschak, E., Peinecke, V., Prenninger, P., Schaffer, T., and Hacker, V. 2006. Detection of fuel cell critical status by stack voltage analysis. Journal of Power Sources 157, 2, 837–840.

  • Oxygen and Carbon Dioxide Separation at Cathodes of Anion Exchange Membrane Cells

    by Martin Florian Groß, Niklas Röttgen, Sabrina Volz, Carsten Cremers

    From the development of anion exchange membrane fuel cells it is known that airborne CO2 is easily absorbed in this type of membranes and has a detrimental effect on the conductivity of the membrane1. It was also found, however, that at sufficiently high current densities carbonate and hydrogen carbonate ions are flushed out of the membrane and ion conduction occurs predominantly via hydroxyl ions1. This behavior led to the idea of using AEM based cells for gas separation for two different type of applications. So, during the first waves of COVID-19 medical oxygen became a scarce resource. Local production of oxygen by separation from air is an interesting approach to overcome this issue. This should be feasible using an anion exchange membrane cell with an air side oxygen reduction electrode and an oxygen evolution electrode. The hope is that in combination of these two reactions the required cell voltage can be kept much below typical water electrolysis voltages so that operation with simple PV cells or modules is possible. At the same time the question is if current densities can be achieved at which the OH- transport and thus the anodic release of O2 dominates, as an enrichment of CO2 must be avoided for this application. On the opposite there are worries about the effect of increasing CO2 concentration in occupied confined rooms like vehicles. Here a device that removes CO2 from air without consuming much oxygen is desirable. The removal of CO2 from the air supply to AEM fuel cells by an additional cell placed upstream of the cathode inlet and downstream of the anode outlet was demonstrated by Matz at al.2. As for CO2 separation only, no hydrogen is available for the anode reaction here again the operation against an oxygen evolution electrode is required, optimized, however, towards the CO2 transport minimizing O2 transport. In this study for one type of AEM membrane and ionomer, namely Fumapem FAA3 and Fumion (both Fumatech BWT, Germany) the effect of different cathode electrodes and electrode materials as well as the effect of operation conditions towards the selectivity of oxygen or CO2 transport were investigated. For that purpose, test set-ups were used were the cathode side was supplied with synthetic air, compressed air or synthetic air with added CO2 and the anode side with an inert gas N2 or helium. Nass spectrometry and dedicated CO2 concentration sensors were used to determine the anodic release of O2 and CO2 as well as the reduction of O2 and CO2 concentrations on the cathode side. First measurements of the oxygen transfer using a cell with a silver cathode (Oxag, Gaskatel, Germany) and a nickel foam anode (Gaskatel, Germany) it was found that the oxygen transfer had a promising faradaic efficiency exceeding 80% (cf. Fig. 1). The cell voltage of 1.5 V at 90 mA cm-2 was however still too high for the application. Replacing the Oxag silver electrode by an industrial ORR electrode for alkaline cells did not yield an improvement (cf. fig 2). Increasing humidification to 100 % r.H. improved the current density (cf. Fig 3). Using high humidification conditions, the CO2 effect was studied by switching from synthetic air to pressured air and back and 160 mA cm-2. A rapid increase of the anodic CO2 concentration to values exceeding 2000 ppm was observed (cf. Fig. 4). Comparing CO2 transfer for cells with Oxag cathode and the commercial ORR cathode again showed that the latter would not improve the situation. It proves however, that the CO2 transfer rate can be influenced by the cathode catalyst. Regarding the CO2 separation test with synthetic air with added 3.85 Vol% of CO2 as cathode feed have shown that under such conditions, mainly CO2 is transported (cf. Fig. 5). In total it will be shown that CO2 separation with state-of-the-art materials is already possible. The use of O2 separation regarding onside production of medical O2 today fails due to still too high CO2 selectivity. The fact that CO2 selectivity seems to be dependent on the cathode catalyst may allow further optimization also valuable for AEMFC fuel cell developments. Acknowledgment: The work received financial support in parts from the Fraunhofer-Gesellschaft by the Demo-medVer project part project e3C-O2 as part of the Fraunhofer cs. Corona program. M. Inaba, Y. Matsui, M. Saito, A. Tasaka, K. Fukuta, S. Watanabe and H. Yanagi, Electrochemistry, 79, 322–325 (2011). 2. S. Matz, B. Setzler, C. M. Weiss, L. Shi, S. Gottesfeld and Y. Yan, Meet. Abstr., MA2020-02(34), 2227 (2020). Figure 1