Norbert Tarjányi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Norbert Tarjányi has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Daniel Káčik
Univ Zilina, Fac Elect Engn & Informat Technol, Dept Phys, Univ 1, Zilina 01026, Slovakia
8 shared publicationsIvan Turek
8 shared publicationsDaniel Kacik
Department of Physics, Faculty of Electrical Engineering, University of Žilina, Žilina, Slovakia
4 shared publicationsIvan Martinček
4 shared publications- Daniel Kacik
Department of Physics, Faculty of Electrical Engineering, University of Zilina, 010 26 Zilina, Slovakia
3 shared publications Ivan Martincek
Department of Physics, University of Zilina in Zilina, Zilina, Slovakia
3 shared publications
Latest Publications
- Open Access
- 10 February 2025
- Published by Elsevier in Optical Materials
- Vol. 160
Liquid absorption-induced photoelasticity of polydimethylsiloxane
- 10 February 2025
- Published by Elsevier in Optical Materials
- Vol. 160
Open AccessLiquid absorption-induced photoelasticity of polydimethylsiloxane
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2778 (1)
Birefringent material-based optical scales
Based on the knowledge of polycarbonate (PC) birefringence obtained from our previous studies, we designed and realized a scales prototype that can determine the magnitude of the load based on the evaluation of the birefringence of the loaded polycarbonate element. The individual mechanical parts of the scales were manufactured using a 3D printer and combined into one compact unit. After assembling the scales, its calibration was performed by measuring the dependence of the intensity of light passing through the PC element on its load. In this paper, we report the design and realization of the scales and demonstrate their functionality.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2778 (1)
Open AccessBirefringent material-based optical scales
Based on the knowledge of polycarbonate (PC) birefringence obtained from our previous studies, we designed and realized a scales prototype that can determine the magnitude of the load based on the evaluation of the birefringence of the loaded polycarbonate element. The individual mechanical parts of the scales were manufactured using a 3D printer and combined into one compact unit. After assembling the scales, its calibration was performed by measuring the dependence of the intensity of light passing through the PC element on its load. In this paper, we report the design and realization of the scales and demonstrate their functionality.
- 1 March 2021
- Published by Elsevier in Applied Surface Science
- Vol. 542
Birefringence dispersion of 6CHBT liquid crystal determined in VIS-NIR spectral range
- 1 March 2021
- Published by Elsevier in Applied Surface Science
- Vol. 542
Birefringence dispersion of 6CHBT liquid crystal determined in VIS-NIR spectral range
- Open Access
- 1 April 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11354, 93
PMMA birefringence-based optical sensor of load
The results of an investigation of polymethylmetacrylate deformation due to applied high-load utilizing its birefringence are presented in the paper. The sample under the test was placed between two plane polarizers, illuminated by white light and gradually stressed using a machine for fatigue testing of materials. The spectra of transmitted light were measured as function of load and deformation using optical fiber spectral analyzers for visible (VIS) and near infrared (NIR) spectral ranges. The measured spectra were normalized and light intensities for selected wavelengths as function of load and deformation were compared with the dependences according to models describing the stress-induced birefringence of PMMA as function of load and deformation, respectively. A good match between the dependences resulting from the measured data and those calculated according to models implies the models can be used for calculating calibrations curves of PMMA-based sensors of load and/or deformation
- 1 April 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11354, 93
Open AccessPMMA birefringence-based optical sensor of load
The results of an investigation of polymethylmetacrylate deformation due to applied high-load utilizing its birefringence are presented in the paper. The sample under the test was placed between two plane polarizers, illuminated by white light and gradually stressed using a machine for fatigue testing of materials. The spectra of transmitted light were measured as function of load and deformation using optical fiber spectral analyzers for visible (VIS) and near infrared (NIR) spectral ranges. The measured spectra were normalized and light intensities for selected wavelengths as function of load and deformation were compared with the dependences according to models describing the stress-induced birefringence of PMMA as function of load and deformation, respectively. A good match between the dependences resulting from the measured data and those calculated according to models implies the models can be used for calculating calibrations curves of PMMA-based sensors of load and/or deformation
- 5 March 2019
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 58 (03) , 034101-7
Group and phase birefringence dispersion of pure and doped lithium niobate crystals obtained by analysis of interference pattern observed behind a plane polariscope
A sample of lithium niobate crystal with known thickness is set on a vertical rotary stage, placed in between two crossed plane polarizers and illuminated by a collimated beam of white light. The sample is rotated to an appropriate position, and interference fringes observed behind an analyzer are recorded by a fiber-optic spectrometer. The recorded channeled spectrum is then analyzed, and from measured positions of interference minima (dark fringes) and known crystal’s thickness, the group birefringence of the crystal sample is obtained as a function of wavelength. The fringe order versus position of the fringe within the spectrum is fitted by appropriate dispersion function, and as the result phase birefringence as a function of wavelength is found. The measurement is performed for a sample declared as undoped, a sample doped with 0.025 wt. % of Fe, and a sample doped with 0.025 wt. % of Fe and 0.075 wt. % of Mn in the wavelength ranges (470 to 780) nm and (900 to 1700) nm. A good agreement between group birefringence dispersion obtained from positions of interference minima and known sample’s thickness and that calculated from phase birefringence dispersion given by Sellmeier dispersion model (used for undoped sample) and Cauchy model (used for doped samples) is found.
- 5 March 2019
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 58 (03) , 034101-7
Group and phase birefringence dispersion of pure and doped lithium niobate crystals obtained by analysis of interference pattern observed behind a plane polariscope
A sample of lithium niobate crystal with known thickness is set on a vertical rotary stage, placed in between two crossed plane polarizers and illuminated by a collimated beam of white light. The sample is rotated to an appropriate position, and interference fringes observed behind an analyzer are recorded by a fiber-optic spectrometer. The recorded channeled spectrum is then analyzed, and from measured positions of interference minima (dark fringes) and known crystal’s thickness, the group birefringence of the crystal sample is obtained as a function of wavelength. The fringe order versus position of the fringe within the spectrum is fitted by appropriate dispersion function, and as the result phase birefringence as a function of wavelength is found. The measurement is performed for a sample declared as undoped, a sample doped with 0.025 wt. % of Fe, and a sample doped with 0.025 wt. % of Fe and 0.075 wt. % of Mn in the wavelength ranges (470 to 780) nm and (900 to 1700) nm. A good agreement between group birefringence dispersion obtained from positions of interference minima and known sample’s thickness and that calculated from phase birefringence dispersion given by Sellmeier dispersion model (used for undoped sample) and Cauchy model (used for doped samples) is found.
- 1 December 2018
- Published by Elsevier in Applied Surface Science
- Vol. 461, 139-142
Determination of sub-nanometer distance from reflective surface by Fabry-Perot interferometer
- 1 December 2018
- Published by Elsevier in Applied Surface Science
- Vol. 461, 139-142
Determination of sub-nanometer distance from reflective surface by Fabry-Perot interferometer
- 1 August 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1996 (1) , 020048
Photoelastic birefringence of polycarbonate as a basis for optical sensors of load
In the paper we present the results of an experimental investigation of birefringence of polycarbonate specimens that are subject to compressive stress. A plane polariscope setup is used for investigation and the so called residual birefringence of unloaded samples is determined in VIS, first. After that a load within the range of elastic deformation is gradually applied to the specimen under investigation and the spectra of light transmitted through the polarizer – compressed sample – analyzer are recorded and the loading head displacement is measured. Normalized intensity of light as function of strain is obtained and analyzed in order to get the photoelastic birefringence as function of strain. The obtained results are discussed in terms of suitability of polycarbonate material for constructing optical sensors of load.
- 1 August 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1996 (1) , 020048
Photoelastic birefringence of polycarbonate as a basis for optical sensors of load
In the paper we present the results of an experimental investigation of birefringence of polycarbonate specimens that are subject to compressive stress. A plane polariscope setup is used for investigation and the so called residual birefringence of unloaded samples is determined in VIS, first. After that a load within the range of elastic deformation is gradually applied to the specimen under investigation and the spectra of light transmitted through the polarizer – compressed sample – analyzer are recorded and the loading head displacement is measured. Normalized intensity of light as function of strain is obtained and analyzed in order to get the photoelastic birefringence as function of strain. The obtained results are discussed in terms of suitability of polycarbonate material for constructing optical sensors of load.
- 9 May 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10680, 106801X
Polydimethylsiloxane Fabry-Perot interferometer and its sensing application
A preparation of polydimethylsiloxane (PDMS) interferometer located at the end of a single-mode optical fiber is presented. For preparation of Fabry-Perot interferometer (FPI) we used the PDMS Sylgard 184 (Dow Corning). During fabrication process of FPI the length of micro-cavity in PDMS can be set to required size. After the setting the length of microcavity was fixed by encapsulating of another layer of PDMS. By measuring the transmission characteristic under the constant conditions of environments we observe a periodic change of signal depending on the wavelength – interference pattern. When the measurand is applied on FPI, PDMS changes its volume and also its refractive index resulting in a change in length of microcavity. The change of length of FPI modifies the interference pattern. For evaluation of influence of measurands change, we chose one maximum (wavelength of the maximum) as a reference wavelength at the reflected spectra. Then we changed the amount of measurand and we observed wavelength shift of the maximum and compared it with the wavelength of reference maximum of reflected spectra. We investigated the sensitivity of PDMS FPI on temperature and pressure. The dependencies to temperature and pressure have linear character. The temperature sensitivity of fabricated PDMS FPI is 5.76 nm/°C. In free spectral range of FPI it is possible to determine the difference of temperature 2.7 °C. After that 2π jump in reflected spectra occurs. The pressure sensitivity is -0.64 nm/kPa and free spectral range of FPI corresponds to 11 kPa.
- 9 May 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10680, 106801X
Polydimethylsiloxane Fabry-Perot interferometer and its sensing application
A preparation of polydimethylsiloxane (PDMS) interferometer located at the end of a single-mode optical fiber is presented. For preparation of Fabry-Perot interferometer (FPI) we used the PDMS Sylgard 184 (Dow Corning). During fabrication process of FPI the length of micro-cavity in PDMS can be set to required size. After the setting the length of microcavity was fixed by encapsulating of another layer of PDMS. By measuring the transmission characteristic under the constant conditions of environments we observe a periodic change of signal depending on the wavelength – interference pattern. When the measurand is applied on FPI, PDMS changes its volume and also its refractive index resulting in a change in length of microcavity. The change of length of FPI modifies the interference pattern. For evaluation of influence of measurands change, we chose one maximum (wavelength of the maximum) as a reference wavelength at the reflected spectra. Then we changed the amount of measurand and we observed wavelength shift of the maximum and compared it with the wavelength of reference maximum of reflected spectra. We investigated the sensitivity of PDMS FPI on temperature and pressure. The dependencies to temperature and pressure have linear character. The temperature sensitivity of fabricated PDMS FPI is 5.76 nm/°C. In free spectral range of FPI it is possible to determine the difference of temperature 2.7 °C. After that 2π jump in reflected spectra occurs. The pressure sensitivity is -0.64 nm/kPa and free spectral range of FPI corresponds to 11 kPa.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Investigation of birefringence of elastically deformed poly(methyl methacrylate)
In the paper we present the results of an experimental investigation of birefringence of a poly(methyl methacrylate) small blocks that are subject to applied mechanical stress. First, the investigated sample is placed between two crossed linear polarizers that effectively polarize visible light within the range from 470 nm to 750 nm, and birefringence of the unloaded sample is measured. After that a load causing elastic deformation is gradually applied to the sample. A white-light source is used for investigation and response of the polarizer-stressed sample-analyzer optical system is detected via optical fiber connected to an optical spectral analyzer. The measured intensity of light transmitted through the optical system is plotted as function of wavelength for various loads. Analysis of the obtained spectra led to the dependences of the normalized intensity of light on the load as well as the birefringence on the load for various wavelengths. The character of the dependences indicates the possibility of utilization the material as a basis for an element of a sensor of pressure, stress, small deformations or for weight measuring.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Investigation of birefringence of elastically deformed poly(methyl methacrylate)
In the paper we present the results of an experimental investigation of birefringence of a poly(methyl methacrylate) small blocks that are subject to applied mechanical stress. First, the investigated sample is placed between two crossed linear polarizers that effectively polarize visible light within the range from 470 nm to 750 nm, and birefringence of the unloaded sample is measured. After that a load causing elastic deformation is gradually applied to the sample. A white-light source is used for investigation and response of the polarizer-stressed sample-analyzer optical system is detected via optical fiber connected to an optical spectral analyzer. The measured intensity of light transmitted through the optical system is plotted as function of wavelength for various loads. Analysis of the obtained spectra led to the dependences of the normalized intensity of light on the load as well as the birefringence on the load for various wavelengths. The character of the dependences indicates the possibility of utilization the material as a basis for an element of a sensor of pressure, stress, small deformations or for weight measuring.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Enhanced sensitivity of polydimethylsiloxane Fabry-Perot interferometer temperature sensor
A polydimethylsiloxane (PDMS) Fabry-Perot interferometer placed at the end of single-mode optical fiber is proposed and demonstrated experimentally. The temperature sensitivity of the interferometer 2.5 nm /°C in the range 28 °C to 35 °C was achieved. To enhance the sensitivity of the temperature sensor another interferometer (in Mach-Zehnder configuration) was used. In this case the sensitivity is enhanced by Vernier effect. The temperature sensitivity was enhanced to 14.8 nm/°C what is almost 6 times higher. Interesting attribute of such configuration is possibility to change free spectral range (FSR) of the second interferometer due to optical path difference settings. So, it is possible to change the sensitivity of the sensor.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Enhanced sensitivity of polydimethylsiloxane Fabry-Perot interferometer temperature sensor
A polydimethylsiloxane (PDMS) Fabry-Perot interferometer placed at the end of single-mode optical fiber is proposed and demonstrated experimentally. The temperature sensitivity of the interferometer 2.5 nm /°C in the range 28 °C to 35 °C was achieved. To enhance the sensitivity of the temperature sensor another interferometer (in Mach-Zehnder configuration) was used. In this case the sensitivity is enhanced by Vernier effect. The temperature sensitivity was enhanced to 14.8 nm/°C what is almost 6 times higher. Interesting attribute of such configuration is possibility to change free spectral range (FSR) of the second interferometer due to optical path difference settings. So, it is possible to change the sensitivity of the sensor.