Markus Lindkvist
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Markus Lindkvist has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
C. Grönlund
Department of Radiation Sciences, Biomedical Engineering , Umeå University , Umeå , Sweden ; Centre of Biomedical Engineering and Physics (CMTF) , Umeå University , Umeå , Sweden
2 shared publications- Ronnie Lundström
Umeå University
2 shared publications - Anders Wänman
Department of Clinical Oral Physiology Umeå University Umeå Sweden
1 shared publication Asta Lindmark
Department of Work and the Physical Environment, National Institute for Working Life, Umeå, Sweden
1 shared publication- Birgitta Häggman‐Henrikson
Department of Orofacial Pain and Jaw Function, Faculty of Odontology Malmo University Malmö Sweden
1 shared publication - Björn-Markus Karlsson
Department of Clinical Sciences, Umeå University, Sweden
1 shared publication
Latest Publications
- Open Access
- 9 January 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-9
Precontractile optical response during excitation-contraction in human muscle revealed by non-invasive high-speed spatiotemporal NIR measurement
During muscle contraction the excitation-contraction process mediates the neural input and mechanical output. Proper muscle function and body locomotion depends on the status of the elements in the same process. However, non-invasive and in-vivo methods to study this are not available. Here we show the existence of an optical response occurring during the excitation-contraction process in human biceps brachii muscle. We developed a non-invasive instrument from a photodiode array and light emitting diodes to detect spatially propagating (~5 m/s) and precontractile (~6 ms onset) optical signals closely related to the action potential during electrostimulation. Although this phenomenon was observed 60 years ago on isolated frog muscle cells in the lab, it has not been shown in-vivo before now. We anticipate our results to be a starting point for a new category in-vivo studies, characterising alterations in the excitation-contraction process in patients with neuromuscular disease and to monitor effects of therapy.
- 9 January 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-9
Open AccessPrecontractile optical response during excitation-contraction in human muscle revealed by non-invasive high-speed spatiotemporal NIR measurement
During muscle contraction the excitation-contraction process mediates the neural input and mechanical output. Proper muscle function and body locomotion depends on the status of the elements in the same process. However, non-invasive and in-vivo methods to study this are not available. Here we show the existence of an optical response occurring during the excitation-contraction process in human biceps brachii muscle. We developed a non-invasive instrument from a photodiode array and light emitting diodes to detect spatially propagating (~5 m/s) and precontractile (~6 ms onset) optical signals closely related to the action potential during electrostimulation. Although this phenomenon was observed 60 years ago on isolated frog muscle cells in the lab, it has not been shown in-vivo before now. We anticipate our results to be a starting point for a new category in-vivo studies, characterising alterations in the excitation-contraction process in patients with neuromuscular disease and to monitor effects of therapy.
- 14 October 2014
- Published by Taylor & Francis in Spectroscopy Letters
- Vol. 48 (3) , 170-172
Absolute Quantifications of Oxy- and Deoxyhemoglobin Concentrations by Combination of Differentially Resolved Spectroscopy and Spatially Resolved Spectroscopy
This letter proposes a theoretical framework to calculate absolute concentrations of oxy- and deoxyhemoglobin using continuous-wave near-infrared spectroscopy. While previous methods on this topic require assumptions on constant blood volume, the proposed method does not. Equations for the absolute concentrations were derived from a combination of the modified Beer–Lambert equation and the theory of diffusion of photons in turbid media. The method has an advantage over and is theoretically consistent with previous methods. It needs yet to be evaluated in an experimental study.
- 14 October 2014
- Published by Taylor & Francis in Spectroscopy Letters
- Vol. 48 (3) , 170-172
Absolute Quantifications of Oxy- and Deoxyhemoglobin Concentrations by Combination of Differentially Resolved Spectroscopy and Spatially Resolved Spectroscopy
This letter proposes a theoretical framework to calculate absolute concentrations of oxy- and deoxyhemoglobin using continuous-wave near-infrared spectroscopy. While previous methods on this topic require assumptions on constant blood volume, the proposed method does not. Equations for the absolute concentrations were derived from a combination of the modified Beer–Lambert equation and the theory of diffusion of photons in turbid media. The method has an advantage over and is theoretically consistent with previous methods. It needs yet to be evaluated in an experimental study.
- 25 July 2014
- Published by Springer Nature in Experimental Brain Research
- Vol. 232 (11) , 3501-3508
Jaw-opening accuracy is not affected by masseter muscle vibration in healthy men
There is a functional integration between the jaw and neck regions with head extension-flexion movements during jaw-opening/closing tasks. We recently reported that trigeminal nociceptive input by injection of hypertonic saline into the masseter muscle altered this integrated jaw-neck function during jaw-opening/closing tasks. Thus, in jaw-opening to a predefined position, the head-neck component increased during pain. Previous studies have indicated that muscle spindle stimulation by vibration of the masseter muscle may influence jaw movement amplitudes, but the possible effect on the integrated jaw-neck function is unknown. The aim of this study was to investigate the effect of masseter muscle vibration on jaw-head movements during a continuous jaw-opening/closing task to a target position. Sixteen healthy men performed two trials without vibration (Control) and two trials with bilateral masseter muscle vibration (Vibration). Movements of the mandible and the head were registered with a wireless three-dimensional optoelectronic recording system. Differences in jaw-opening and head movement amplitudes between Control and Vibration, as well as achievement of the predefined jaw-opening target position, were analysed with Wilcoxon's matched pairs test. No significant group effects from vibration were found for jaw or head movement amplitudes, or in the achievement of the target jaw-opening position. A covariation between the jaw and head movement amplitudes was observed. The results imply a high stability for the jaw motor system in a target jaw-opening task and that this task was achieved with the head-neck and jaw working as an integrated system.
- 25 July 2014
- Published by Springer Nature in Experimental Brain Research
- Vol. 232 (11) , 3501-3508
Jaw-opening accuracy is not affected by masseter muscle vibration in healthy men
There is a functional integration between the jaw and neck regions with head extension-flexion movements during jaw-opening/closing tasks. We recently reported that trigeminal nociceptive input by injection of hypertonic saline into the masseter muscle altered this integrated jaw-neck function during jaw-opening/closing tasks. Thus, in jaw-opening to a predefined position, the head-neck component increased during pain. Previous studies have indicated that muscle spindle stimulation by vibration of the masseter muscle may influence jaw movement amplitudes, but the possible effect on the integrated jaw-neck function is unknown. The aim of this study was to investigate the effect of masseter muscle vibration on jaw-head movements during a continuous jaw-opening/closing task to a target position. Sixteen healthy men performed two trials without vibration (Control) and two trials with bilateral masseter muscle vibration (Vibration). Movements of the mandible and the head were registered with a wireless three-dimensional optoelectronic recording system. Differences in jaw-opening and head movement amplitudes between Control and Vibration, as well as achievement of the predefined jaw-opening target position, were analysed with Wilcoxon's matched pairs test. No significant group effects from vibration were found for jaw or head movement amplitudes, or in the achievement of the target jaw-opening position. A covariation between the jaw and head movement amplitudes was observed. The results imply a high stability for the jaw motor system in a target jaw-opening task and that this task was achieved with the head-neck and jaw working as an integrated system.
- 22 January 2013
- Published by Taylor & Francis in Spectroscopy Letters
- Vol. 46 (4) , 243-249
Coherent Derivation of Equations for Differential Spectroscopy and Spatially Resolved Spectroscopy: An Undergraduate Tutorial
Near-infrared spectroscopy (NIRS) is a spectroscopic method that is frequently used in health care and sports medicine to monitor oxygenation parameters in biological tissue. This tutorial provides a coherent derivation of equations for differential spectroscopy and spatially resolved spectroscopy, from basic theories to implementable equations. The basic theories are applicable to any kind of tissue oximeter but mainly focus on continuous-wave instruments.
- 22 January 2013
- Published by Taylor & Francis in Spectroscopy Letters
- Vol. 46 (4) , 243-249
Coherent Derivation of Equations for Differential Spectroscopy and Spatially Resolved Spectroscopy: An Undergraduate Tutorial
Near-infrared spectroscopy (NIRS) is a spectroscopic method that is frequently used in health care and sports medicine to monitor oxygenation parameters in biological tissue. This tutorial provides a coherent derivation of equations for differential spectroscopy and spatially resolved spectroscopy, from basic theories to implementable equations. The basic theories are applicable to any kind of tissue oximeter but mainly focus on continuous-wave instruments.
- 23 September 2011
- Published by Wiley in Acta Paediatrica
- Vol. 101 (2) , 148-154
Sound and vibration: effects on infants’ heart rate and heart rate variability during neonatal transport
Aim: To measure the effect of sound and whole‐body vibration on infants’ heart rate and heart rate variability during ground and air ambulance transport.Methods: Sixteen infants were transported by air ambulance with ground ambulance transport to and from the airports. Whole‐body vibration and sound levels were recorded and heart parameters were obtained by ECG signal.Results: Sound and whole‐body vibration levels exceeded the recommended limits. Mean whole‐body vibration and sound levels were 0.19 m/s2 and 73 dBA, respectively. Higher whole‐body vibration was associated with a lower heart rate (p < 0.05), and higher sound level was linked to a higher heart rate (p = 0.05). The heart rate variability was significantly higher at the end of the transport than at the beginning (p < 0.01). Poorer physiological status was associated with lower heart rate variability (p < 0.001) and a lower heart rate (p < 0.01). Infants wearing earmuffs had a lower heart rate (p < 0.05).Conclusions: Sound and whole‐body vibration during neonatal transport exceed recommended levels for adults, and sound seem to have a more stressful effect on the infant than vibrations. Infants should wear earmuffs during neonatal transport because of the stress‐reducing effect.
- 23 September 2011
- Published by Wiley in Acta Paediatrica
- Vol. 101 (2) , 148-154
Sound and vibration: effects on infants’ heart rate and heart rate variability during neonatal transport
Aim: To measure the effect of sound and whole‐body vibration on infants’ heart rate and heart rate variability during ground and air ambulance transport.Methods: Sixteen infants were transported by air ambulance with ground ambulance transport to and from the airports. Whole‐body vibration and sound levels were recorded and heart parameters were obtained by ECG signal.Results: Sound and whole‐body vibration levels exceeded the recommended limits. Mean whole‐body vibration and sound levels were 0.19 m/s2 and 73 dBA, respectively. Higher whole‐body vibration was associated with a lower heart rate (p < 0.05), and higher sound level was linked to a higher heart rate (p = 0.05). The heart rate variability was significantly higher at the end of the transport than at the beginning (p < 0.01). Poorer physiological status was associated with lower heart rate variability (p < 0.001) and a lower heart rate (p < 0.01). Infants wearing earmuffs had a lower heart rate (p < 0.05).Conclusions: Sound and whole‐body vibration during neonatal transport exceed recommended levels for adults, and sound seem to have a more stressful effect on the infant than vibrations. Infants should wear earmuffs during neonatal transport because of the stress‐reducing effect.
- 1 January 2011
- Published by American Psychological Association (APA) in Journal of Experimental Psychology: Human Perception and Performance
- Vol. 37 (4) , 1134-1139
A behavioral study of distraction by vibrotactile novelty.
Past research has demonstrated that the occurrence of unexpected task-irrelevant changes in the auditory or visual sensory channels captured attention in an obligatory fashion, hindering behavioral performance in ongoing auditory or visual categorization tasks and generating orientation and re-orientation electrophysiological responses. We report the first experiment extending the behavioral study of cross-modal distraction to tactile novelty. Using a vibrotactile-visual cross-modal oddball task and a bespoke hand-arm vibration device, we found that participants were significantly slower at categorizing the parity of visually presented digits following a rare and unexpected change in vibrotactile stimulation (novelty distraction), and that this effect extended to the subsequent trial (postnovelty distraction). These results are in line with past research on auditory and visual novelty and fit the proposition of common and amodal cognitive mechanisms for the involuntary detection of change.
- 1 January 2011
- Published by American Psychological Association (APA) in Journal of Experimental Psychology: Human Perception and Performance
- Vol. 37 (4) , 1134-1139
A behavioral study of distraction by vibrotactile novelty.
Past research has demonstrated that the occurrence of unexpected task-irrelevant changes in the auditory or visual sensory channels captured attention in an obligatory fashion, hindering behavioral performance in ongoing auditory or visual categorization tasks and generating orientation and re-orientation electrophysiological responses. We report the first experiment extending the behavioral study of cross-modal distraction to tactile novelty. Using a vibrotactile-visual cross-modal oddball task and a bespoke hand-arm vibration device, we found that participants were significantly slower at categorizing the parity of visually presented digits following a rare and unexpected change in vibrotactile stimulation (novelty distraction), and that this effect extended to the subsequent trial (postnovelty distraction). These results are in line with past research on auditory and visual novelty and fit the proposition of common and amodal cognitive mechanisms for the involuntary detection of change.
- 1 June 2009
- Published by Elsevier in Journal of Electromyography and Kinesiology
- Vol. 19 (3) , 407-415
Changes in EMG activity in the upper trapezius muscle due to local vibration exposure
- 1 June 2009
- Published by Elsevier in Journal of Electromyography and Kinesiology
- Vol. 19 (3) , 407-415
Changes in EMG activity in the upper trapezius muscle due to local vibration exposure
- 6 October 2007
- Published by Springer Nature in International Archives of Occupational and Environmental Health
- Vol. 81 (5) , 603-611
Acute effects of vibration on thermal perception thresholds
- 6 October 2007
- Published by Springer Nature in International Archives of Occupational and Environmental Health
- Vol. 81 (5) , 603-611
Acute effects of vibration on thermal perception thresholds