Shin-Ichiro Fujii
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shin-Ichiro Fujii has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Akiko Takatsu
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki, 305-8563, Japan
14 shared publications - Kazumi Inagaki
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), AIST Tsukuba Central 3, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8563, Japan
14 shared publications Koichi Chiba
National Metrology Institute of Japan (NMIJ)
9 shared publications- Shin-Ichi Miyashita
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba 305-8563, Ibaraki, Japan
8 shared publications - Alexander S. Groombridge
Echion Technologies
5 shared publications Mitsuru Abo
Department of Applied Biological Chemistry, Graduate School of Agricultural and Life Sciences, The University of Tokyo
5 shared publications
Latest Publications
- Open Access
- 1 June 2023
- Published by The Mass Spectrometry Society of Japan in Journal of the Mass Spectrometry Society of Japan
- Vol. 71 (2) , 46-50
核酸分子を対象とした定量分析のための標準物質開発
- 1 June 2023
- Published by The Mass Spectrometry Society of Japan in Journal of the Mass Spectrometry Society of Japan
- Vol. 71 (2) , 46-50
Open Access核酸分子を対象とした定量分析のための標準物質開発
- 25 February 2022
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 432, 128576
Cell population behavior of the unicellular red alga Galdieria sulphuraria during precious metal biosorption
- 25 February 2022
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 432, 128576
Cell population behavior of the unicellular red alga Galdieria sulphuraria during precious metal biosorption
- Open Access
- 1 November 2021
- Published by Elsevier in Journal of Hazardous Materials Advances
- Vol. 3
Effect of lyophilization on the acid resistance of a unicellular red alga Galdieria sulphuraria during platinum recovery
- 1 November 2021
- Published by Elsevier in Journal of Hazardous Materials Advances
- Vol. 3
Open AccessEffect of lyophilization on the acid resistance of a unicellular red alga Galdieria sulphuraria during platinum recovery
- 24 July 2014
- Published by Springer Nature in Chromatographia
- Vol. 77 (19-20) , 1333-1338
HPLC for Separation and Quantification of Deoxyribonucleic Acid Fragments and Measurement of Deoxyribonucleic Acid Degradation
- 24 July 2014
- Published by Springer Nature in Chromatographia
- Vol. 77 (19-20) , 1333-1338
HPLC for Separation and Quantification of Deoxyribonucleic Acid Fragments and Measurement of Deoxyribonucleic Acid Degradation
- 20 May 2014
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 29 (9) , 1598-1606
Highly efficient single-cell analysis of microbial cells by time-resolved inductively coupled plasma mass spectrometry
To realise highly efficient single-cell analysis of microbial cells by time-resolved inductively coupled plasma mass spectrometry (ICP-MS), we developed a modified high efficiency cell introduction system (HECIS), consisting of a large-bore high performance concentric nebulizer (LB-HPCN) with a centre capillary tube of 150 μm inner diameter and a custom-made small-volume (15 cm3) on-axis spray chamber that uses a sheath gas flow near the chamber exit to suppress cell deposition. We also assembled an external ion pulse counting unit to directly read the ion pulse current from the electron multiplier of the ICP-MS via a function generator with no dead time, in order to obtain data with sufficiently high time resolution (i.e., 0.05–1 ms). As compared to a conventional ICP-MS working at its minimum integration time (10 ms), this assembly led to more than ca. 13-fold higher signal-to-background ratios for 31P, and made higher throughput of cells to the plasma more feasible. By using the modified HECIS and the external ion pulse counting unit for determination of the cell introduction efficiencies of different-sized unicellular microbes, including yeast (Saccharomyces cerevisiae), cyanobacterium (Synechocystis sp. PCC 6803), red algae (Cyanidioschyzon merolae 10D and Galdieria sulphuraria), and green alga (Chlamydomonas reinhardtii CC-125), it was revealed that their cell introduction efficiencies ranged from 86% (for C. reinhardtii CC-125 with a mean cell diameter of 6.4 μm) to ca. 100% (for other microbes with mean cell diameters of 2.0–3.0 μm), implying that by use of the ICP-MS system, the cell introduction efficiencies are able to reach approximately 100% and tend to decrease with increasing cell sizes (at least more than 3.1 μm in mean diameter). A wide range of biologically important elements, such as C, Mg, Al, P, S, K, Ca, Cr, Mn, Fe, and Zn, were tested for reasonable detection using the ICP-MS system. Results likely corresponding to separate cell events were obtained for some elements present in each microbe.
- 20 May 2014
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 29 (9) , 1598-1606
Highly efficient single-cell analysis of microbial cells by time-resolved inductively coupled plasma mass spectrometry
To realise highly efficient single-cell analysis of microbial cells by time-resolved inductively coupled plasma mass spectrometry (ICP-MS), we developed a modified high efficiency cell introduction system (HECIS), consisting of a large-bore high performance concentric nebulizer (LB-HPCN) with a centre capillary tube of 150 μm inner diameter and a custom-made small-volume (15 cm3) on-axis spray chamber that uses a sheath gas flow near the chamber exit to suppress cell deposition. We also assembled an external ion pulse counting unit to directly read the ion pulse current from the electron multiplier of the ICP-MS via a function generator with no dead time, in order to obtain data with sufficiently high time resolution (i.e., 0.05–1 ms). As compared to a conventional ICP-MS working at its minimum integration time (10 ms), this assembly led to more than ca. 13-fold higher signal-to-background ratios for 31P, and made higher throughput of cells to the plasma more feasible. By using the modified HECIS and the external ion pulse counting unit for determination of the cell introduction efficiencies of different-sized unicellular microbes, including yeast (Saccharomyces cerevisiae), cyanobacterium (Synechocystis sp. PCC 6803), red algae (Cyanidioschyzon merolae 10D and Galdieria sulphuraria), and green alga (Chlamydomonas reinhardtii CC-125), it was revealed that their cell introduction efficiencies ranged from 86% (for C. reinhardtii CC-125 with a mean cell diameter of 6.4 μm) to ca. 100% (for other microbes with mean cell diameters of 2.0–3.0 μm), implying that by use of the ICP-MS system, the cell introduction efficiencies are able to reach approximately 100% and tend to decrease with increasing cell sizes (at least more than 3.1 μm in mean diameter). A wide range of biologically important elements, such as C, Mg, Al, P, S, K, Ca, Cr, Mn, Fe, and Zn, were tested for reasonable detection using the ICP-MS system. Results likely corresponding to separate cell events were obtained for some elements present in each microbe.
- Open Access
- 10 February 2014
- Published by Springer Nature in Analytical Sciences
- Vol. 30 (2) , 219-224
Time-resolved ICP-MS Measurement: a New Method for Elemental and Multiparametric Analysis of Single Cells
Time-resolved inductively coupled plasma mass spectrometry (ICP-MS) has attracted much attention for elemental and multiparametric analysis of single cells, instead of a classical bulk analysis of large amount of cells after a dissolution. In the time-resolved measurement, cells are directly introduced into the plasma via nebulizing or micro drop dispensing, and then ion plumes corresponding to single cells are individually detected with a high time resolution. The sensitivity and cell throughput in the measurement strongly depend on the time resolution. A high cell introduction efficiency into the plasma supports for a reduction of cell consumption. Biomolecules can also be measured through the attachment of elemental tags, and then the amount distribution of elements and biomolecules in single cells can be evaluated, while providing information concerning cell-to-cell variations. By applying ICP time-of-flight mass spectrometry (ICP-TOFMS), multiparametric analysis of elements and biomolecules can be achieved similar to that by a flow cytometer. This article highlights the technical aspects of the time-resolved ICP-MS measurement technique for elemental and multiparametric analysis of single cells.
- 10 February 2014
- Published by Springer Nature in Analytical Sciences
- Vol. 30 (2) , 219-224
Open AccessTime-resolved ICP-MS Measurement: a New Method for Elemental and Multiparametric Analysis of Single Cells
Time-resolved inductively coupled plasma mass spectrometry (ICP-MS) has attracted much attention for elemental and multiparametric analysis of single cells, instead of a classical bulk analysis of large amount of cells after a dissolution. In the time-resolved measurement, cells are directly introduced into the plasma via nebulizing or micro drop dispensing, and then ion plumes corresponding to single cells are individually detected with a high time resolution. The sensitivity and cell throughput in the measurement strongly depend on the time resolution. A high cell introduction efficiency into the plasma supports for a reduction of cell consumption. Biomolecules can also be measured through the attachment of elemental tags, and then the amount distribution of elements and biomolecules in single cells can be evaluated, while providing information concerning cell-to-cell variations. By applying ICP time-of-flight mass spectrometry (ICP-TOFMS), multiparametric analysis of elements and biomolecules can be achieved similar to that by a flow cytometer. This article highlights the technical aspects of the time-resolved ICP-MS measurement technique for elemental and multiparametric analysis of single cells.
- 14 December 2013
- Published by Wiley in Electrophoresis
- Vol. 35 (9) , 1315-1318
Separation and quantification of RNA molecules using size‐exclusion chromatography hyphenated with inductively coupled plasma‐mass spectrometry
The hyphenation of SEC with ICP-MS was successfully applied to RNA quantification. The developed method combines the separation technique for large biomolecules and element selective detection of ICP-MS. The separation of RNA molecules was performed under the SEC condition without additive reagents such as salts to prevent the adhesion of RNA molecules on the column resin. Fragments of RNA, which were commercially available as a ladder marker solution and certified reference materials, were successfully separated and analyzed by measuring 31P+ with this method. RNA was quantified with good repeatability (RSD of peak area; 2.7%, n = 3) and linearity (R2 = 0.999) using a P standard solution as a calibrant. LOD and absolute detection limit of RNA were 6.7 μg/kg and 67 pg, respectively, which were equal to the values obtained by the analysis of a P standard solution. The accuracy of the proposed measurement was evaluated by measuring certified reference materials of RNA solutions for quantitative analysis (NMIJ CRM 6204-a). The results obtained by this method agreed with the certified values within uncertainty. The proposed analysis method, which demonstrates good accuracy and high precision and is free from interference by nucleotide analogues, qualifies as a method of quality control for the RNA synthesis and extraction process.
- 14 December 2013
- Published by Wiley in Electrophoresis
- Vol. 35 (9) , 1315-1318
Separation and quantification of RNA molecules using size‐exclusion chromatography hyphenated with inductively coupled plasma‐mass spectrometry
The hyphenation of SEC with ICP-MS was successfully applied to RNA quantification. The developed method combines the separation technique for large biomolecules and element selective detection of ICP-MS. The separation of RNA molecules was performed under the SEC condition without additive reagents such as salts to prevent the adhesion of RNA molecules on the column resin. Fragments of RNA, which were commercially available as a ladder marker solution and certified reference materials, were successfully separated and analyzed by measuring 31P+ with this method. RNA was quantified with good repeatability (RSD of peak area; 2.7%, n = 3) and linearity (R2 = 0.999) using a P standard solution as a calibrant. LOD and absolute detection limit of RNA were 6.7 μg/kg and 67 pg, respectively, which were equal to the values obtained by the analysis of a P standard solution. The accuracy of the proposed measurement was evaluated by measuring certified reference materials of RNA solutions for quantitative analysis (NMIJ CRM 6204-a). The results obtained by this method agreed with the certified values within uncertainty. The proposed analysis method, which demonstrates good accuracy and high precision and is free from interference by nucleotide analogues, qualifies as a method of quality control for the RNA synthesis and extraction process.
- Open Access
- 10 June 2013
- Published by Springer Nature in Analytical Sciences
- Vol. 29 (6) , 597-603
High Sensitive Elemental Analysis of Single Yeast Cells (Saccharomyces cerevisiae) by Time-Resolved Inductively-Coupled Plasma Mass Spectrometry Using a High Efficiency Cell Introduction System
Trace elemental analysis of single yeast cells with time-resolved inductively coupled plasma mass spectrometry (ICP-MS) was successfully carried out, where a high efficiency cell introduction system (HECIS) consisting of the high performance concentric nebulizer (HPCN) and a low-volume (15 mL) on-axis spray chamber utilizing a sheath gas flow were used. Cell adsorption to the flow injector and sample tubing was reduced with the addition of a simple 4.3 mmol L−1 of NaCl solution to the cell suspension and cell flowing liquid, allowing consecutive measurements without fear of significant contamination from previous measurements. Initially using a quadrupole mass analyzer ICP-MS (ICP-QMS) at its lowest integration time (10 ms), current spikes corresponding to separate cell events were detected for several elements (Mg, P, Ca, Mn, Fe, Cu, and Zn) on the introduction of the cell suspension. On comparing the number of peaks in the spectrum for phosphorous with the cell count using a haemocytometer, a reproducible cell transport efficiency of 75.0 ± 4.7% was achieved. Preliminary experiments into using time of flight ICP-MS (ICP-TOFMS) for single-cell analysis were carried out, allowing quasi-simultaneous multielement detection. The spectra of Mg, P, Ca, Mn, Fe, Cu, and Zn, with a time resolution of 1 ms were simultaneously obtained in one measurement. A relatively strong correlation was observed for the spectra between P and Zn (correlation factor 0.69), P and Mg (0.63), and Mg and Zn (0.63). These results indicate that the time resolved quasi-simultaneous multielement measurement may be useful for the correlation analysis of multielements in cells.
- 10 June 2013
- Published by Springer Nature in Analytical Sciences
- Vol. 29 (6) , 597-603
Open AccessHigh Sensitive Elemental Analysis of Single Yeast Cells (Saccharomyces cerevisiae) by Time-Resolved Inductively-Coupled Plasma Mass Spectrometry Using a High Efficiency Cell Introduction System
Trace elemental analysis of single yeast cells with time-resolved inductively coupled plasma mass spectrometry (ICP-MS) was successfully carried out, where a high efficiency cell introduction system (HECIS) consisting of the high performance concentric nebulizer (HPCN) and a low-volume (15 mL) on-axis spray chamber utilizing a sheath gas flow were used. Cell adsorption to the flow injector and sample tubing was reduced with the addition of a simple 4.3 mmol L−1 of NaCl solution to the cell suspension and cell flowing liquid, allowing consecutive measurements without fear of significant contamination from previous measurements. Initially using a quadrupole mass analyzer ICP-MS (ICP-QMS) at its lowest integration time (10 ms), current spikes corresponding to separate cell events were detected for several elements (Mg, P, Ca, Mn, Fe, Cu, and Zn) on the introduction of the cell suspension. On comparing the number of peaks in the spectrum for phosphorous with the cell count using a haemocytometer, a reproducible cell transport efficiency of 75.0 ± 4.7% was achieved. Preliminary experiments into using time of flight ICP-MS (ICP-TOFMS) for single-cell analysis were carried out, allowing quasi-simultaneous multielement detection. The spectra of Mg, P, Ca, Mn, Fe, Cu, and Zn, with a time resolution of 1 ms were simultaneously obtained in one measurement. A relatively strong correlation was observed for the spectra between P and Zn (correlation factor 0.69), P and Mg (0.63), and Mg and Zn (0.63). These results indicate that the time resolved quasi-simultaneous multielement measurement may be useful for the correlation analysis of multielements in cells.
- Open Access
- 1 January 2013
- Published by Oxford University Press (OUP) in Metallomics
- Vol. 5 (5) , 424-428
A coupling system of capillary gel electrophoresis with inductively coupled plasma-mass spectrometry for the determination of double stranded DNA fragments
The coupling system of capillary gel electrophoresis (CGE) and inductively coupled plasma-mass spectrometry (ICP-MS) was newly developed and successfully applied to the double-stranded (ds) DNA quantification. The developed system combines the separation technique for large biomolecules and element selective detection of ICP-MS. This coupling was achieved by using the modified high performance concentric nebulizer (HPCN) with the PTFE tube (HPCN-PT), which can produce the liquid jet by the flow focusing effect. The HPCN-PT effectively nebulizes the highly viscous solution containing gel buffer even at a low flow rate. At a liquid flow rate of 0.010 mL min−1 and a nebulizer gas flow rate of 1 L min−1, the Sauter mean diameter (D3,2) of primary aerosols generated by the HPCN-PT was 3.4 μm, and over 90% (v/v) of the aerosol droplets were less than 10 μm in diameter. The electrophoresis capillary filled with gel buffer was connected to the HPCN-PT via the interface. This interface has two connectors and an electrode that can connect CE and ICP-MS. After the electrophoretic separation at atmospheric pressure, the samples were transferred to the ICP-MS through the interface by applying additional pressure. Fragments of dsDNA, which were commercially available as a ladder marker solution, were successfully separated and analyzed by measuring 31P+ with CGE-ICP-MS, and a linear calibration curve of the phosphorus standard solution (R2 = 0.999) was obtained from 2.7 to 27 mg kg−1. The detection limit (LOD) and absolute detection limit of P were 3.7 μg kg−1 and 0.6 pg (equivalent to 6 pg of DNA), respectively. This absolute detection limit value was equal to the conventional fluorescence determination of DNA.
- 1 January 2013
- Published by Oxford University Press (OUP) in Metallomics
- Vol. 5 (5) , 424-428
Open AccessA coupling system of capillary gel electrophoresis with inductively coupled plasma-mass spectrometry for the determination of double stranded DNA fragments
The coupling system of capillary gel electrophoresis (CGE) and inductively coupled plasma-mass spectrometry (ICP-MS) was newly developed and successfully applied to the double-stranded (ds) DNA quantification. The developed system combines the separation technique for large biomolecules and element selective detection of ICP-MS. This coupling was achieved by using the modified high performance concentric nebulizer (HPCN) with the PTFE tube (HPCN-PT), which can produce the liquid jet by the flow focusing effect. The HPCN-PT effectively nebulizes the highly viscous solution containing gel buffer even at a low flow rate. At a liquid flow rate of 0.010 mL min−1 and a nebulizer gas flow rate of 1 L min−1, the Sauter mean diameter (D3,2) of primary aerosols generated by the HPCN-PT was 3.4 μm, and over 90% (v/v) of the aerosol droplets were less than 10 μm in diameter. The electrophoresis capillary filled with gel buffer was connected to the HPCN-PT via the interface. This interface has two connectors and an electrode that can connect CE and ICP-MS. After the electrophoretic separation at atmospheric pressure, the samples were transferred to the ICP-MS through the interface by applying additional pressure. Fragments of dsDNA, which were commercially available as a ladder marker solution, were successfully separated and analyzed by measuring 31P+ with CGE-ICP-MS, and a linear calibration curve of the phosphorus standard solution (R2 = 0.999) was obtained from 2.7 to 27 mg kg−1. The detection limit (LOD) and absolute detection limit of P were 3.7 μg kg−1 and 0.6 pg (equivalent to 6 pg of DNA), respectively. This absolute detection limit value was equal to the conventional fluorescence determination of DNA.