LMLewis McMillan

Lewis McMillan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lewis McMillan has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Simulating photodynamic therapy for the treatment of glioblastoma using Monte Carlo radiative transport

    by Louise Finlayson, Lewis McMillan, Szabolcs Suveges, Douglas Steele, Raluca Eftimie, Dumitru Trucu, Christian Thomas A. Brown, Ewan Eadie, Kismet Hossain-Ibrahim, Kenneth Wood

    Glioblastoma (GBM) brain tumors are a rare occurrence with only 3.19-4.1/100,000 people diagnosed globally every year.1 However, due to their aggressive nature and high resistance to treatment, patient prognosis is often poor, with a median overall survival rate of 14.6 months when treated with the current standard of care, which involves resection surgery followed by radiotherapy and chemotherapy.2 An increase in the percentage of tumor removed during resection has been shown to correlate with a positive increase in survival time,3 and so there is interest in finding safe ways to maximize the resection margin.


  • Open Access

    A divide and conquer approach to maximise deep learning mammography classification accuracies

    by Adam Jaamour, Craig Myles, Ashay Patel, Shuen-Jen Chen, Lewis McMillan, David Harris-Birtill

    Breast cancer claims 11,400 lives on average every year in the UK, making it one of the deadliest diseases. Mammography is the gold standard for detecting early signs of breast cancer, which can help cure the disease during its early stages. However, incorrect mammography diagnoses are common and may harm patients through unnecessary treatments and operations (or a lack of treatment). Therefore, systems that can learn to detect breast cancer on their own could help reduce the number of incorrect interpretations and missed cases. Various deep learning techniques, which can be used to implement a system that learns how to detect instances of breast cancer in mammograms, are explored throughout this paper. Convolution Neural Networks (CNNs) are used as part of a pipeline based on deep learning techniques. A divide and conquer approach is followed to analyse the effects on performance and efficiency when utilising diverse deep learning techniques such as varying network architectures (VGG19, ResNet50, InceptionV3, DenseNet121, MobileNetV2), class weights, input sizes, image ratios, pre-processing techniques, transfer learning, dropout rates, and types of mammogram projections. This approach serves as a starting point for model development of mammography classification tasks. Practitioners can benefit from this work by using the divide and conquer results to select the most suitable deep learning techniques for their case out-of-the-box, thus reducing the need for extensive exploratory experimentation. Multiple techniques are found to provide accuracy gains relative to a general baseline (VGG19 model using uncropped 512 × 512 pixels input images with a dropout rate of 0.2 and a learning rate of 1 × 10−3) on the Curated Breast Imaging Subset of DDSM (CBIS-DDSM) dataset. These techniques involve transfer learning pre-trained ImagetNet weights to a MobileNetV2 architecture, with pre-trained weights from a binarised version of the mini Mammography Image Analysis Society (mini-MIAS) dataset applied to the fully connected layers of the model, coupled with using weights to alleviate class imbalance, and splitting CBIS-DDSM samples between images of masses and calcifications. Using these techniques, a 5.6% gain in accuracy over the baseline model was accomplished. Other deep learning techniques from the divide and conquer approach, such as larger image sizes, do not yield increased accuracies without the use of image pre-processing techniques such as Gaussian filtering, histogram equalisation and input cropping.


  • Open Access

    Meshless Monte Carlo radiation transfer method for curved geometries using signed distance functions

    by Lewis McMillan, Graham D. Bruce, Kishan Dholakia

    Significance: Monte Carlo radiation transfer (MCRT) is the gold standard for modeling light transport in turbid media. Typical MCRT models use voxels or meshes to approximate experimental geometry. A voxel-based geometry does not allow for the precise modeling of smooth curved surfaces, such as may be found in biological systems or food and drink packaging. Mesh-based geometry allows arbitrary complex shapes with smooth curved surfaces to be modeled. However, mesh-based models also suffer from issues such as the computational cost of generating meshes and inaccuracies in how meshes handle reflections and refractions.Aim: We present our algorithm, which we term signedMCRT (sMCRT), a geometry-based method that uses signed distance functions (SDF) to represent the geometry of the model. SDFs are capable of modeling smooth curved surfaces precisely while also modeling complex geometries.Approach: We show that using SDFs to represent the problem’s geometry is more precise than voxel and mesh-based methods.Results: sMCRT is validated against theoretical expressions, and voxel and mesh-based MCRT codes. We show that sMCRT can precisely model arbitrary complex geometries such as microvascular vessel network using SDFs. In comparison with the current state-of-the-art in MCRT methods specifically for curved surfaces, sMCRT is more precise for cases where the geometry can be defined using combinations of shapes.Conclusions: We believe that SDF-based MCRT models are a complementary method to voxel and mesh models in terms of being able to model complex geometries and accurately treat curved surfaces, with a focus on precise simulation of reflections and refractions. sMCRT is publicly available at https://github.com/lewisfish/signedMCRT.


  • Open Access

    To focus-match or not to focus-match inverse spatially offset Raman spectroscopy: a question of light penetration

    by Georgina E. Shillito, Lewis Mcmillan, Graham D. Bruce, Kishan Dholakia

    The ability to identify the contents of a sealed container, without the need to extract a sample, is desirable in applications ranging from forensics to product quality control. One technique suited to this is inverse spatially offset Raman spectroscopy (ISORS) which illuminates a sample of interest with an annular beam of light and collects Raman scattering from the center of the ring, thereby retrieving the chemical signature of the contents while suppressing signal from the container. Here we explore in detail the relative benefits of a recently developed variant of ISORS, called focus-matched ISORS. In this variant, the Fourier relationship between the annular beam and a tightly focused Bessel beam is exploited to focus the excitation light inside the sample and to match the focal point of excitation and collection optics to increase the signal from the contents without compromising the suppression of the container signal. Using a flexible experimental setup which can realize both traditional and focus-matched ISORS, and Monte-Carlo simulations, we elucidate the relative advantages of the two techniques for a range of optical properties of sample and container.


  • Open Access

    Imaging in thick samples, a phased Monte Carlo radiation transfer algorithm

    by Lewis McMillan, Sascha L. Reidt, Cameron McNicol, Isla R. M. Barnard, Michael P. MacDonald, Christian T. A. Brown, Kenneth Wood

    Imaging in thick samples is key to understanding more complex samples, such as developing embryos, organoids, or tissues. Optical imaging is a powerful tool for quantitative and functional imaging but has traditionally struggled with thicker samples where scattering dominates. For example, imaging of zebrafish embryos using lightsheet microscopy is very successful due in large part to the high transparency and low scattering in those particular embryos.1,2 Achieving a greater depth of focus can be achieved using more sophisticated illumination geometries, such as Airy or Bessel beam illumination in lightsheet microscopy.3 However, imaging of samples such as chick embyros, which constitutes a more physiologically relevant model for human embryonic development, is greatly hindered by greater levels of scattering in the embryonic tissue.4


  • Open Access

    Development of a Predictive Monte Carlo Radiative Transfer Model for Ablative Fractional Skin Lasers

    by Lewis McMillan, Paul O'MAhoney, Kairui Feng, Kanheng Zheng, Isla R.M. Barnard, Chunhui Li, Sally Ibbotson, Ewan Eadie, C. Tom. A. Brown, Kenneth Wood

    It is possible to enhance topical drug delivery by pretreatment of the skin with ablative fractional lasers (AFLs). However, the parameters to use for a given AFL to achieve the desired depth of ablation or the desired therapeutic or cosmetic outcome are hard to predict. This leaves open the real possibility of overapplication or underapplication of laser energy to the skin. In this study, we developed a numerical model consisting of a Monte Carlo radiative transfer (MCRT) code coupled to a heat transfer and tissue damage algorithm. The simulation is designed to predict the depth effects of AFL on the skin, verified with in vitro experiments in porcine skin via optical coherence tomography (OCT) imaging. Ex vivo porcine skin is irradiated with increasing energies (50–400 mJ/pixel) from a CO2 AFL. The depth of microscopic treatment zones is measured and compared with our numerical model. The data from the OCT images and MCRT model complement each other well. Nonablative thermal effects on surrounding tissue are also discussed. This model, therefore, provides an initial step toward a predictive determination of the effects of AFL on the skin. Lasers Surg. Med. © 2020 The Authors. Lasers in Surgery and Medicine published by Wiley Periodicals LLC


  • Could psoralen plus ultraviolet A1 (‘ PUVA 1’) work? Depth penetration achieved by phototherapy lamps

    by I.R.M. Barnard, E. Eadie, L. McMillan, H. Moseley, T. Brown, K. Wood, R. Dawe


  • Quantifying Direct DNA Damage in the Basal Layer of Skin Exposed to UV Radiation from Sunbeds

    by Isla Rose Mary Barnard, Patrick Tierney, Catherine Louise Campbell, Lewis McMillan, Harry Moseley, Ewan Eadie, Christian Thomas Alcuin Brown, Kenneth Wood

    Nonmelanoma and melanoma skin cancers are attributable to DNA damage caused by ultraviolet (UV) radiation exposure. One DNA photoproduct, the cyclobutane pyrimidine dimer (CPD), is believed to lead to DNA mutations caused by UV radiation. Using radiative transfer simulations, we compare the number of CPDs directly induced by UV irradiation from artificial and natural UV sources (a standard sunbed and the midday summer Mediterranean sun) for skin types I and II on the Fitzpatrick scale. We use Monte Carlo radiative transfer (MCRT) modeling to track the progression of UV photons through a multilayered three dimensional (3D) grid that simulates the upper layers of the skin. By recording the energy deposited in the DNA‐containing cells of the basal layer, the number of CPDs formed can be quantified. The aim of this work was to compare the number of CPDs formed in the basal layer of the skin and by implication the risk of developing cancer, as a consequence of irradiation by artificial and natural sources. Our simulations show that the number of CPDs formed per second during sunbed irradiation is almost three times that formed during solar irradiation.