RMRohit Mishra

Rohit Mishra

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rohit Mishra has a total of 106 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Low–High–Low Rotationally Pulse-Actuated Serial Dissolvable Film Valves Applied to Solid Phase Extraction and LAMP Isothermal Amplification for Plant Pathogen Detection on a Lab-on-a-Disc

    by Lourdes An Julius, Muhammad Mubashar Saeed, Tim Kuijpers, Sergei Sandu, Grace Henihan, Tanja Dreo, Cor D Schoen, Rohit Mishra, Nicholas J Dunne, Eadaoin Carthy, et al.

    The ability of the centrifugal Lab-on-a-Disc (LoaD) platform to closely mimic the "on bench" liquid handling steps (laboratory unit operations (LUOs)) such as metering, mixing, and aliquoting supports on-disc automation of bioassay without the need for extensive biological optimization. Thus, well-established bioassays, normally conducted manually using pipettes or using liquid handling robots, can be relatively easily automated in self-contained microfluidic chips suitable for use in point-of-care or point-of-use settings. The LoaD's ease of automation is largely dependent on valves that can control liquid movement on the rotating disc. The optimum valving strategy for a true low-cost and portable device is rotationally actuated valves, which are actuated by changes in the disc spin-speed. However, due to tolerances in disc manufacturing and variations in reagent properties, most of these valving technologies have inherent variation in their actuation spin-speed. Most valves are actuated through stepped increases in disc spin-speed until the motor reaches its maximum speed (rarely more than 6000 rpm). These manufacturing tolerances combined with this "analogue" mechanism of valve actuation limits the number of LUOs that can be placed on-disc. In this work, we present a novel valving mechanism called low-high-low serial dissolvable film (DF) valves. In these valves, a DF membrane is placed in a dead-end pneumatic chamber. Below an actuation spin-speed, the trapped air prevents liquid wetting and dissolving the membrane. Above this spin-speed, the liquid will enter and wet the DF and open the valve. However, as DFs take ∼40 s to dissolve, the membrane can be wetted, and the disc spin-speed reduced before the film opens. Thus, by placing valves in a series, we can govern on which "digital pulse" in spin-speeding a reagent is released; a reservoir with one serial valve will open on the first pulse, a reservoir with two serial valves on the second, and so on. This "digital" flow control mechanism allows the automation of complex assays with high reliability. In this work, we first describe the operation of the valves, outline the theoretical basis for their operation, and support this analysis with an experiment. Next, we demonstrate how these valves can be used to automate the solid-phase extraction of DNA on on-disc LAMP amplification for applications in plant pathogen detection. The disc was successfully used to extract and detect, from a sample lysed off-disc, DNA indicating the presence of thermally inactivated Clavibacter michiganensis ssp. michiganensis (Cmm), a bacterial pathogen on tomato leaf samples.


  • Open Access

    An Automated Centrifugal Microfluidic Platform for Efficient Multistep Blood Sample Preparation and Clean-Up towards Small Ion-Molecule Analysis

    by Yuting Hou, Rohit Mishra, Yufeng Zhao, Jens Ducrée, Jed D. Harrison

    Sample preparation for mass spectroscopy typically involves several liquid and solid phase clean-ups, extractions, and other unit operations, which are labour-intensive and error-prone. We demonstrate a centrifugal microfluidic platform that automates the whole blood sample’s preparation and clean-up by combining traditional liquid-phase and multiple solid-phase extractions for applications in mass spectroscopy (MS)-based small molecule detection. Liquid phase extraction was performed using methanol to precipitate proteins in plasma separated from a blood sample under centrifugal force. The preloaded solid phase composed of C18 beads then removed lipids with a combination of silica particles, which further cleaned up any remaining proteins. We further integrated the application of this sample prep disc with matrix-assisted laser desorption/ionization (MALDI) MS by using glancing angle deposition films, which further cleaned up the processed sample by segregating the electrolyte background from the sample salts. Additionally, hydrophilic interaction liquid chromatography (HILIC) MS was employed for detecting targeted free amino acids. Therefore, several representative ionic metabolites, including several amino acids and organic acids from blood samples, were analysed by both MALDI-MS and HILIC-MS to demonstrate the performance of this sample preparation disc. The fully automated blood sample preparation procedure only took 35 mins, with a throughput of three parallel units.


  • Open Access

    Digital process control of multi-step assays on centrifugal platforms using high-low-high rotational-pulse triggered valving

    by Philip L. Early, Niamh A. Kilcawley, Niamh A. McArdle, Marine Renou, Sinéad M. Kearney, Rohit Mishra, Nikolay Dimov, Macdara T. Glynn, Jens Ducrée, David J. Kinahan

    Due to their capability for comprehensive sample-to-answer automation, the interest in centrifugal microfluidic systems has greatly increased in industry and academia over the last quarter century. The main applications of these “Lab-on-a-Disc” (LoaD) platforms are in decentralised bioanalytical point-of-use / point-of-care testing. Due to the unidirectional and omnipresent nature of the centrifugal force, advanced flow control is key to coordinate multi-step / multi-reagent assay formats on the LoaD. Formerly, flow control was often achieved by capillary burst valves which require gradual increments of the spin speed of the system-innate spindle motor. Recent advanced introduced a flow control scheme called ’rotational pulse actuated valves’. In these valves the sequence of valve actuation is determined by the architecture of the disc while actuation is triggered by freely programmable upward spike (i.e. Low-High-Low (LHL)) in the rotational frequency. This paradigm shift from conventional ‘analogue’ burst valves to ‘digital’ pulsing significantly increases the number of sequential while also improving the overall robustness of flow control. In this work, we expand on these LHL valves by introducing High-Low-High (HLH) pulse-actuated (PA) valving which are actuated by ’downward’ spike in the disc spin-rate. These HLH valves are particularly useful for high spin-rate operations such as centrifugation of blood. We introduce two different HLH architectures and then combine the most promising with LHL valves to implement the time-dependent liquid handling protocol underlying a common liver function test panel.


  • Open Access

    Plant pathogen detection on a lab-on-a-disc using solid-phase extraction and isothermal nucleic acid amplification enabled by digital pulse-actuated dissolvable film valves

    by Rohit Mishra, Lourdes An. Julius, Jack Condon, Patricija Pavelskopfa, Philip L. Early, Matthew Dorrian, Katarina Mrvova, Grace Henihan, Faith Mangwanya, Tanya Dreo, et al.


  • Open Access

    Siphon-Controlled Automation on a Lab-on-a-Disc Using Event-Triggered Dissolvable Film Valves

    by Brian D. Henderson, David J. Kinahan, Jeanne Rio, Rohit Mishra, Damien King, Sarai M. Torres-Delgado, Dario Mager, Jan G. Korvink, Jens Ducrée

    Within microfluidic technologies, the centrifugal microfluidic “Lab-on-a-Disc” (LoaD) platform offers great potential for use at the PoC and in low-resource settings due to its robustness and the ability to port and miniaturize ‘wet bench’ laboratory protocols. We present the combination of ‘event-triggered dissolvable film valves’ with a centrifugo-pneumatic siphon structure to enable control and timing, through changes in disc spin-speed, of the release and incubations of eight samples/reagents/wash buffers. Based on these microfluidic techniques, we integrated and automated a chemiluminescent immunoassay for detection of the CVD risk factor marker C-reactive protein displaying a limit of detection (LOD) of 44.87 ng mL−1 and limit of quantitation (LoQ) of 135.87 ng mL−1.


  • Label-free, spatially multiplexed SPR detection of immunoassays on a highly integrated centrifugal Lab-on-a-Disc platform

    by Celina M. Miyazaki, David J. Kinahan, Rohit Mishra, Faith Mangwanya, Niamh Kilcawley, Marystela Ferreira, Jens Ducrée


  • Wirelessly powered and remotely controlled valve-array for highly multiplexed analytical assay automation on a centrifugal microfluidic platform

    by Saraí M. Torres Delgado, David J. Kinahan, Lourdes Albina Nirupa Julius, Adam Mallette, David Sáenz Ardila, Rohit Mishra, Celina M. Miyazaki, Jan G. Korvink, Jens Ducrée, Dario Mager


  • Automation of multi-analyte prostate cancer biomarker immunoassay panel from whole blood by minimum-instrumentation rotational flow control

    by Rohit Mishra, Julia Zapatero-Rodríguez, Shikha Sharma, Domhnall Kelly, Darren McAuley, Sarah Gilgunn, Richard O’kEnnedy, Jens Ducrée


  • Automated assembly of microfluidic "lab-on-a-disc"

    by Marvin Berger, Tobias Müller, Toni Christopher Voebel, Christoph Baum, Christian Brecher, Tom Glennon, Rohit Mishra, Damien King, David Kinahan, Jens Ducrée

    Point-of-care (POC) testing attracts more and more attention in the medical health sector because of their specific property to perform the diagnostic close to the patient. The fast diagnosis right at the hospital or the doctor’s office improves the medical reaction time and the chances for a successful healing process. One of this POC test systems is a “Lab-on-a-Disc” (LoaD) which looks like a compact disc crisscrossed with microfluidic tubes and cavities. The fluid to be analysed is placed in the LoaD and an external device then rotates the LoaD. The cavities inside the LoaD and the centrifugal force ensure a clearly defined sequence of the analysis. Furthermore, we aim for an inexpensive manufacture of the medical product without neglecting its quality and functionality. Therefore, the Fraunhofer IPT works on an assembly cell to implement dissoluble films concisely into the disc. This dissoluble film demonstrates its successful usage as a gate for the fluid, which opens after a predefined moment in the cycle. Furthermore, we investigate to integrate a laser welding process into our gantry system and demonstrate its efficiency with the welding of polymer discs. This procedure is clinically safe because no further laser absorption material is needed in the sealing process, which might pollute the LoaD. Moreover, this process allows the alignment of several discs before the welding and therefore leads to precisely manufactured LoaDs in large quantities. All these methods together enable a fast, costefficient and reliable mass production to bring POC testing among the people.