MGMolly Goodier

Molly Goodier

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Molly Goodier has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Inter‐rater variability in patch test readings and final interpretation using store‐forward teledermatology

    by Molly C. Goodier, Joel G. DeKoven, James S. Taylor, Denis Sasseville, Joseph F. Fowler, Anthony F. Fransway, Vincent A. DeLeo, James G. Marks, Kathryn A. Zug, Sara A. Hylwa, et al.

    Background Data regarding teledermatology for patch testing are limited. Objectives Compare patch test readings and final interpretation by 2 in‐person dermatologists (IPDs) with 8 teledermatologists (TDs). Methods Patch tested patients had photographs taken of 70 screening series allergens at 48‐hour (48H) and second (2nd) readings. 8 TDs reviewed photos and graded reactions (negative, irritant, doubtful, +, ++, +++) at 48H and 2nd readings; in addition, they coded a final interpretation (allergic, indeterminant, irritant, negative) for each reaction. TDs rated overall image quality and confidence level for each patient and patch test reaction, respectively. Percentage of TD‐IPD agreement based on clinical significance (success, indeterminate, and failure) were calculated. Primary outcome was agreement at 2nd reading. Results Data were available for 99, 101, and 66 participants at 48H, 2nd reading, and final interpretation, respectively. Pooled failure (+/++/+++ vs negative) at 2nd reading was 13.6% (range 7.9‐20.4%). Pooled failure at 48H and final interpretation was 5.4% (range 2.9‐6.8%) and 24.6% (range 10.2‐36.8%). Confidence in readings was statistically correlated to quality of images and disagreement. Conclusion For patch testing, teledermatology has significant limitations including clinically significant pooled failure percentages of 13.6% for 2nd readings and 24.6% for final interpretation.


  • Rubber Accelerators in Medical Examination and Surgical Gloves

    by Molly C. Bs Goodier, Sanna D. Ronkainen, Sara A. Hylwa

    Background: Rubber accelerators play a significant role in glove-related occupational contact dermatitis, especially among health care workers. Currently, there is limited information readily available outlining the accelerators used in specific medical examination and surgical gloves. Objective: The aim of this study was to ascertain the accelerators used in medical examination and surgical gloves for major glove manufacturers within the United States. Methods: An initial Internet-based search was performed to establish relevant manufacturers and product lines, with subsequent inquiry with each corresponding company regarding accelerators used in each medical and surgical glove line. Results: Eleven glove manufacturers were identified and contacted. Responses were obtained from all manufacturers, but because of legal limitations, changes in product lines, or inability to supply necessary data, only 8 companies were able to be included in the final analysis, totaling data for 190 gloves. Carbamates were the most common accelerator, used in 90.5% (172/190) of gloves, whereas thiurams were used in only 11 gloves (5.8%). Eight companies surveyed are now advertising and offering touted accelerator-free gloves. Conclusions: Accelerators are used in most examination and surgical gloves; however, manufacturers are now expanding their product offerings to include accelerator-free options.


  • Contact Dermatitis Associated With Skin Cleansers: Retrospective Analysis of North American Contact Dermatitis Group Data 2000–2014

    by Erin M. Warshaw, Molly C. Bs Goodier, Joel G. DeKoven, Howard I. Maibach, James S. Taylor, Denis Sasseville, Donald V. Belsito, Joseph F. Jr Fowler, Anthony F. Fransway, Vincent A. DeLeo, et al.

    Background: There is limited information regarding contact dermatitis (CD) associated with skin cleansers (SCs). Objective: The aim of the study was to evaluate the prevalence of allergic patch test (APT) reactions and irritant CD (ICD) associated with SCs. Methods: A retrospective cross-sectional analysis was performed using North American Contact Dermatitis Group data, 2000–2014. Results: Of 32,945 tested patients, 1069 (3.24%) had either APT reaction or ICD associated with SCs. Of these, 692 (64.7%) had APT reaction only, 350 (32.7%) had ICD only, and 27 (2.5%) had both. Individuals with APT reaction and/or ICD were more likely to have occupationally related skin disease (relative risk [RR] = 3.8 [95% confidence interval {CI} = 3.3–4.5] for APT reaction and 10.0 [95% CI = 8.2–12.2] for ICD, respectively, P < 0.0001). As compared with those without APT reaction to SC, individuals with APT reaction had significantly higher frequencies of hand (RR = 2.4 [95% CI = 2.1–2.7]) and arm dermatitis (RR = 1.3 [95% CI = 1.1–1.6], P ≤ 0.001). Irritant CD was strongly associated with hand dermatitis (RR = 6.2 [95% CI = 5.2–7.3], P < 0.0001). More than 50 allergens were associated with SCs including quaternium-15 (11.2%), cocamidopropyl betaine (9.5%), methylchloroisothiazolinone/methylisothiazolinone (8.4%), coconut diethanolamide (7.9%), fragrance mix I (7.7%), Myroxylon pereirae (5.9%), 4-chloro-3,5-xylenol (5.8%), amidoamine (5.5%), and formaldehyde (4.4%). Conclusions: Many allergens, especially preservatives and surfactants, were associated with SCs. Most cases involved the hands and were occupationally related.


  • Allergic Contact Dermatitis From Methylisothiazolinone in Residential Wall Paint

    by Molly C. Goodier, Linda Ljungberg, Christina Persson, Malin Engfeldt, Magnus Bruze, Erin M. Warshaw

    A 33-year-old woman presented to our clinic for suspected photoallergic contact dermatitis with a recent episode of severe, vesicular dermatitis involving exposed skin and correlating with relocation to a new home. Biopsy results showed spongiotic and lichenoid dermatitis with eosinophils. Patch test results showed a very strong (+++) reaction to methylisothiazolinone (MI), mild (+) reaction to MI/methylchloroisothiazolinone, and no reaction to benzisothiazolinone. These allergens were found in several personal products. However, the patient was suspicious of 4 wall paints recently used in her home. Semiopen patch tests to 3 Behr interior paints showed positive results. Nine controls showed negative results. High-performance liquid chromatography demonstrated MI and benzisothiazolinone in all 4 paints at concentrations ranging from 50 to 100 ppm and 290 to 340 ppm, respectively. Although MI has been reported to cause occupational airborne contact dermatitis in European household painters, to our knowledge, this is the first documented case of paint-related MI allergy in the United States.


    • 1 November 2016
      • Vol. 15  (11) , 1366-1372

    Treatment of Facial Photodamage With Mass Market Topical Products vs Non-ablative Fractional Laser.

    by Hilary Reich, Irmina Wallander, Lacie Schulte, Molly Goodier, Brian Zelickson

    In this split-face, evaluator-blinded study, 18 subjects were randomly assigned to receive either the SSR or NFL treatments on each side of the face. For the SSR facial sides subjects followed two morning-evening regimens. On the NFL sides subjects were treated 3 times with the 1927-nm laser at 4-week intervals. Three physician evaluators were asked to rate hyperpigmentation, global photoaging, and ne lines and wrinkles for each side of the face at baseline and at 3 months using a 5-point scale. The SSR and NFL treatments provided comparable results for each skin attribute. Improvement from baseline was signi - cant in both treatment programs for each skin attribute. The greatest 3-month improvement for both programs was in hyperpigmen- tation. For global photoaging and ne lines and wrinkles, positive responses were slightly greater in the NFL than in the SSR facial sides. Subject preference for the SSR over the NFL was greatest for ne lines around the eyes, ne lines around the mouth, smooth texture, radiant complexion, and overall improvement while the NFL was preferred for skin rmness and evenness. When the study was completed5 of 18 split-face subjects decided to undergo NFR laser treatment on the non laser treated side along with using the SSR product and 13 of the 18 subjects continued to use the SSR products to their full face after the study. The mass market skin care system of the present study provides improvement in hyperpigmentation, global photoaging, and ne lines and wrinkles comparable to that of a series of treatments with a non-ablative fractional laser. J Drugs Dermatol. 2016;15(11):1366-1372..

    • 1 January 2016
      • Vol. 15  (1) , 37-44

    Comparative Study of Professional vs Mass Market Topical Products for Treatment of Facial Photodamage.

    by Hilary Reich, Irmina Wallander, Lacie Schulte, Molly Goodier, Brian Zelickson

    Many over the counter topical products claim to reverse the signs of cutaneous photo-damage. To date, the two most studied ingredients for improving the texture, tone, and pigmentation of the skin are topical retinoids and hydroquinone. This split face study compares a mass market skincare regimen with a prescription skin care regimen for improvement in photo damaged skin. Twenty-seven subjects with moderate photo damaged facial skin were enrolled. Each subject was consented and assigned with the mass market anti-aging system (Treatment A) to one side of the face and the prescription anti-aging system (Treatment B or Treatment C) to the other side of the face. Treatment B contained 13 subjects whom did not use 0.025% Retinol cream. Treatment C contained 14 subjects who used a 0.025% Retinol Cream. Subjects had 4 visits over 12 weeks for digital photography and surveys. Photographs were evaluated by blinded physicians. Physician objective analysis showed all three systems to have a statistically significant clinical improvement in photoaged skin seen in as little as 4 weeks of use. Participant's surveys rated the mass market system higher than both of the professional systems for visible skin changes, ease of use, and likelihood to recommend to a friend. Twelve of twenty-seven subjects preferred the mass market system for overall improvement while twelve thought each system gave the same improvement. This study demonstrates that a mass marketed skin care system can give similar clinical improvements in photo-aged skin as a professionally dispensed prescription system and the majority of participants preferred the mass-marketed system.

  • Normal and Aging Hair Biology and Structure ‘Aging and Hair'

    by Molly Goodier, Maria Hordinsky

    Much like an individual's hairstyle, hair fibers along the scalp see a number of changes over the course of one's lifetime. As the decades pass, the shine and volume synonymous with youthful hair may give way to thin, dull, and brittle hair commonly associated with aging. These changes are a result of a compilation of genetic and environmental elements influencing the cells of the hair follicle, specifically the hair follicle stem cells and melanocytes. Telomere shortening, decrease in cell numbers, and particular transcription factors have all been implicated in this process. In turn, these molecular alterations lead to structural modifications of the hair fiber, decrease in melanin production, and lengthening of the telogen phase of the hair cycle. Despite this inevitable progression with aging, there exists an array of treatments such as light therapy, minoxidil, and finasteride which have been designed to mitigate the effects of aging, particularly balding and thinning hair. Although each works through a different mechanism, all aim to maintain or potentially restore the youthful quality of hair.


  • A randomized comparison of the efficacy of low volume deep placement cheek injection vs. mid‐ to deep dermal nasolabial fold injection technique for the correction of nasolabial folds

    by Molly Goodier, Kendra Elm, Irmina Wallander, Brian Zelickson, Sarah Schram

    Summary: Background: Hyaluronic acid (HA) fillers are FDA approved for improving the appearance of the nasolabial folds. Previous reports on the use of HA for this treatment have focused on injections directly into the location of the desired correction. To our knowledge, a study has not been done evaluating the efficacy of injecting a low volume of HA into the adjacent area of volume loss to correct both volume loss and adjacent lines.Objective: The objective of this study was to compare the effectiveness and safety of three HA injection protocols including deep dermal cheek injection, mid‐ to deep dermal local nasolabial fold injection, and both injections for the correction of nasolabial folds.Methods: This was a split‐face, randomized study evaluating the use of three injection techniques – (i) deep bolus injection into the mid‐ to lateral cheek, (ii) local mid‐ to deep dermal injection into the nasolabial fold, and (iii) both deep injection into the mid‐ to lateral cheek and local mid‐ to deep dermal injection into the nasolabial fold – for the treatment of moderate to severe nasolabial folds. Wrinkle severity and Global Aesthetic Improvement Scales were measured before and 4–6 weeks after treatment as assessed by a blinded investigator.Results: Patient and physician observations showed improvement both globally and in wrinkle severity score with each technique used with no statistical difference between techniques. Patients showed a slight preference for injection to both the mid‐ to lateral cheek and nasolabial fold, which was associated with the greatest amount of filler product administered. No serious adverse events were reported.Conclusion: Injection of a dermal filler, at low volumes, into either the nasolabial fold or mid‐ to lateral cheek results in similar improvement to the correction of the nasolabial folds.