Zhikai Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhikai Zhu has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Zhongping Chen
Beckman Laser Institute, University of California Irvine 1 , Irvine, California 92612
7 shared publications - Yusi Miao
Beckman Laser Institute, University of California Irvine 1 , Irvine, California 92612, USA
4 shared publications - Brian Jet-Fei Wong
Beckman Laser Institute, University of California, Irvine, CA 92697, USA
2 shared publications David Mukai
Beckman Laser Institute, University of California Irvine 1 , Irvine, California 92612
2 shared publicationsDo A. Kim
Univ. of California, Irvine (United States)
2 shared publicationsEllen Hong
Univ. of California, Irvine (United States)
2 shared publications
Latest Publications
- Open Access
- 1 September 2024
- Published by AIP Publishing in APL Photonics
- Vol. 9 (9) , 096109
Quantitative assessment of chlorine gas inhalation injury based on endoscopic OCT and spectral encoded interferometric microscope imaging with deep learning
Chlorine exposure can cause severe airway injuries. While the acute effects of chlorine inhalation are well-documented, the structural changes resulting from the post-acute, high-level chlorine exposure remain less understood. Airway sloughing is one of the standards for doctors to evaluate the lung function. Here, we report the application of a high-resolution swept-source optical coherence tomography system to investigate the progression of injury based on airway sloughing evaluation in a chlorine inhalation rabbit model. This system employs a 1.2 mm diameter flexible fiberoptic endoscopic probe via an endotracheal tube to capture in vivo large airway anatomical changes before and as early as 30 min after acute chlorine exposure. We conducted an animal study using New Zealand white rabbits exposed to acute chlorine gas (800 ppm, 6 min) during ventilation and monitored them using optical coherence tomography (OCT) for 6 h. To measure the volume of airway sloughing induced by chlorine gas, we utilized deep learning for the segmentation task on OCT images. The results showed that the volume of chlorine induced epithelial sloughing on rabbit tracheal walls initially increased, peaked around 30 min, and then decreased. Furthermore, we utilized a spectral encoded interferometric microscopy system to study ex vivo airway cilia beating dynamics based on Doppler shift, aiding in elucidating how chlorine gas affects cilia beating function. Cilia movability and beating frequency were decreased because of the epithelium damage. This quantitative approach has the potential to enhance the diagnosis and monitoring of injuries from toxic gas inhalation and to evaluate the efficacy of antidote treatments for these injuries.
- 1 September 2024
- Published by AIP Publishing in APL Photonics
- Vol. 9 (9) , 096109
Open AccessQuantitative assessment of chlorine gas inhalation injury based on endoscopic OCT and spectral encoded interferometric microscope imaging with deep learning
Chlorine exposure can cause severe airway injuries. While the acute effects of chlorine inhalation are well-documented, the structural changes resulting from the post-acute, high-level chlorine exposure remain less understood. Airway sloughing is one of the standards for doctors to evaluate the lung function. Here, we report the application of a high-resolution swept-source optical coherence tomography system to investigate the progression of injury based on airway sloughing evaluation in a chlorine inhalation rabbit model. This system employs a 1.2 mm diameter flexible fiberoptic endoscopic probe via an endotracheal tube to capture in vivo large airway anatomical changes before and as early as 30 min after acute chlorine exposure. We conducted an animal study using New Zealand white rabbits exposed to acute chlorine gas (800 ppm, 6 min) during ventilation and monitored them using optical coherence tomography (OCT) for 6 h. To measure the volume of airway sloughing induced by chlorine gas, we utilized deep learning for the segmentation task on OCT images. The results showed that the volume of chlorine induced epithelial sloughing on rabbit tracheal walls initially increased, peaked around 30 min, and then decreased. Furthermore, we utilized a spectral encoded interferometric microscopy system to study ex vivo airway cilia beating dynamics based on Doppler shift, aiding in elucidating how chlorine gas affects cilia beating function. Cilia movability and beating frequency were decreased because of the epithelium damage. This quantitative approach has the potential to enhance the diagnosis and monitoring of injuries from toxic gas inhalation and to evaluate the efficacy of antidote treatments for these injuries.
- 3 April 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12830, 103-77
Fast endoscopic OCTA imaging in mouse rectum using proximal scanning catheter
In recent years, endoscopic optical coherence tomography (OCT) has garnered widespread attention for non-invasive advantages in achieving three-dimensional visualization of internal organ cavities. In early-stage lesions, microvascular alterations occur before morphological tissue changes. Therefore, utilizing endoscopic OCTA for the detection of superficial capillaries serves as an adjunctive method for early disease screening. About ten years ago, the advantages of high-speed and stable operation of distal motorized catheters enabled the realization of endoscopic OCTA. However, the internal micro-motors lead to a larger outer diameter of distal imaging catheters, which restricts their clinical applicability for monitoring diseases in narrow luminal structures. Consequently, proximal imaging catheters, with their smaller size, have found its wide application in the commercial arena. However, due to limitations in external motor speed and susceptibility to external vibrations, there were no reports of proximal imaging catheters achieving endoscopic OCTA for a long time. Recently, we proposed the MB-scan scheme to mitigate the impact of external motion artifacts and achieve endoscopic OCTA based on a proximal catheter. The Singular Value Decomposition (SVD) algorithm was employed to eliminate static tissue information and obtain en face OCTA images of the murine rectum. In this study, we proposed a fast endoscopic OCTA using proximal scanning catheter based on B-scan scheme and a customed image registration algorithm. Image registration based on the similarity between adjacent B-scan frames was utilized to reduce the impact of external motor vibrations and improve image quality. Based on the registered images at the same scanning position, the speckle variance (SVAR) algorithm was employed to calculate variation of OCT intensity signals. Finally, en face OCTA images were generated. Collecting data from the mouse rectum, endoscopic OCTA images were obtained from the registered data using the SVAR algorithm.
- 3 April 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12830, 103-77
Fast endoscopic OCTA imaging in mouse rectum using proximal scanning catheter
In recent years, endoscopic optical coherence tomography (OCT) has garnered widespread attention for non-invasive advantages in achieving three-dimensional visualization of internal organ cavities. In early-stage lesions, microvascular alterations occur before morphological tissue changes. Therefore, utilizing endoscopic OCTA for the detection of superficial capillaries serves as an adjunctive method for early disease screening. About ten years ago, the advantages of high-speed and stable operation of distal motorized catheters enabled the realization of endoscopic OCTA. However, the internal micro-motors lead to a larger outer diameter of distal imaging catheters, which restricts their clinical applicability for monitoring diseases in narrow luminal structures. Consequently, proximal imaging catheters, with their smaller size, have found its wide application in the commercial arena. However, due to limitations in external motor speed and susceptibility to external vibrations, there were no reports of proximal imaging catheters achieving endoscopic OCTA for a long time. Recently, we proposed the MB-scan scheme to mitigate the impact of external motion artifacts and achieve endoscopic OCTA based on a proximal catheter. The Singular Value Decomposition (SVD) algorithm was employed to eliminate static tissue information and obtain en face OCTA images of the murine rectum. In this study, we proposed a fast endoscopic OCTA using proximal scanning catheter based on B-scan scheme and a customed image registration algorithm. Image registration based on the similarity between adjacent B-scan frames was utilized to reduce the impact of external motor vibrations and improve image quality. Based on the registered images at the same scanning position, the speckle variance (SVAR) algorithm was employed to calculate variation of OCT intensity signals. Finally, en face OCTA images were generated. Collecting data from the mouse rectum, endoscopic OCTA images were obtained from the registered data using the SVAR algorithm.
- 13 March 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC12818, 8
Endoscope OCT for 3D imaging of sleep apnea patient's airway and airflow dynamics
We present an early release of our study utilizing a fiber-based Optical Coherence Tomography (OCT) probe to acquire 3D images of the airway in sleep apnea patients. The probe, with a 1.3mm diameter, navigates from the nasal cavity to the vocal cords while rotating within a transparent protective sheath. Long-range OCT imaging (2-30mm) enables comprehensive airway visualization. Our approach facilitates airflow dynamic analysis, aiding in the identification of critical regions prone to collapse during sleep. This non-invasive technique promises to revolutionize sleep apnea diagnostics and personalized treatment planning, offering substantial benefits to patient care.
- 13 March 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC12818, 8
Endoscope OCT for 3D imaging of sleep apnea patient's airway and airflow dynamics
We present an early release of our study utilizing a fiber-based Optical Coherence Tomography (OCT) probe to acquire 3D images of the airway in sleep apnea patients. The probe, with a 1.3mm diameter, navigates from the nasal cavity to the vocal cords while rotating within a transparent protective sheath. Long-range OCT imaging (2-30mm) enables comprehensive airway visualization. Our approach facilitates airflow dynamic analysis, aiding in the identification of critical regions prone to collapse during sleep. This non-invasive technique promises to revolutionize sleep apnea diagnostics and personalized treatment planning, offering substantial benefits to patient care.
- 13 March 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC12818, PC1281804
Multimodal imaging of ciliary dynamics using optical coherence tomography and phase-resolved spectrally encoded interferometric microscopy
Proper ciliary dynamics is vital for effective mucociliary transport, the primary defense mechanism for the upper respiratory tract. Abnormal cilia behavior could lead to chronic respiratory disease, making it essential to conduct more detailed studies. In this study we present a multimodality system, specifically using optical coherence tomography (OCT) and phase-resolved spectrally encoded interferometric microscopy (PR-SEIM). We have already shown that PR-SEIM is capable of measuring cilia beat frequency ex vivo. Although we were able to visually identify the ciliary motion in the nasal cavity of rabbits in vivo, due to its sensitivity to motion artifacts, it has been difficult to quantitatively analyze ciliary dynamics. To overcome this obstacle, we incorporated OCT along with a high-speed laser source to compensate for bulk motion. Ultimately, this system will provide a way to study ciliary dynamics in its natural environment, thus allowing more in-depth understanding of ciliary functions.
- 13 March 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC12818, PC1281804
Multimodal imaging of ciliary dynamics using optical coherence tomography and phase-resolved spectrally encoded interferometric microscopy
Proper ciliary dynamics is vital for effective mucociliary transport, the primary defense mechanism for the upper respiratory tract. Abnormal cilia behavior could lead to chronic respiratory disease, making it essential to conduct more detailed studies. In this study we present a multimodality system, specifically using optical coherence tomography (OCT) and phase-resolved spectrally encoded interferometric microscopy (PR-SEIM). We have already shown that PR-SEIM is capable of measuring cilia beat frequency ex vivo. Although we were able to visually identify the ciliary motion in the nasal cavity of rabbits in vivo, due to its sensitivity to motion artifacts, it has been difficult to quantitatively analyze ciliary dynamics. To overcome this obstacle, we incorporated OCT along with a high-speed laser source to compensate for bulk motion. Ultimately, this system will provide a way to study ciliary dynamics in its natural environment, thus allowing more in-depth understanding of ciliary functions.
- 18 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (3) , 732-737
Quantitative Optical Coherence Elastography of the Optic Nerve Head In Vivo
Objective: Optical coherence elastography (OCE) was used to demonstrate the relationship between the elasticity of the optic nerve head (ONH) and different intraocular pressure (IOP) levels in an in-vivo rabbit model for the first time. Method: Both ex-vivo and in-vivo rabbit ONH were imaged using OCE system. A mechanical shaker initiated the propagation of elastic waves, and the elasticity of the ONH was determined by tracking the wave propagation speed. The elasticity of the ONH under varying IOP levels was reconstructed based on the wave speed. Notably, the ONH exhibited increased stiffness with elevated IOP. Results: In the in-vivo rabbit models, the Young's modulus of ONH increased from 14 kPa to 81 kPa with the IOP increased from 15 mmHg to 35 mmHg. This revealed a positive correlation between the Young's modulus of the ONH and intraocular pressure. Conclusion: The OCE system proved effective in measuring the mechanical properties of ONH at different IOP levels, with validation in an in-vivo rabbit model. Significance: Considering ONH plays a critical role in vision and eye diseases, the capability to image and quantify in vivo ONH biomechanical properties has great potential to advance vision science research and improve the clinical management of glaucoma patients.
- 18 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (3) , 732-737
Quantitative Optical Coherence Elastography of the Optic Nerve Head In Vivo
Objective: Optical coherence elastography (OCE) was used to demonstrate the relationship between the elasticity of the optic nerve head (ONH) and different intraocular pressure (IOP) levels in an in-vivo rabbit model for the first time. Method: Both ex-vivo and in-vivo rabbit ONH were imaged using OCE system. A mechanical shaker initiated the propagation of elastic waves, and the elasticity of the ONH was determined by tracking the wave propagation speed. The elasticity of the ONH under varying IOP levels was reconstructed based on the wave speed. Notably, the ONH exhibited increased stiffness with elevated IOP. Results: In the in-vivo rabbit models, the Young's modulus of ONH increased from 14 kPa to 81 kPa with the IOP increased from 15 mmHg to 35 mmHg. This revealed a positive correlation between the Young's modulus of the ONH and intraocular pressure. Conclusion: The OCE system proved effective in measuring the mechanical properties of ONH at different IOP levels, with validation in an in-vivo rabbit model. Significance: Considering ONH plays a critical role in vision and eye diseases, the capability to image and quantify in vivo ONH biomechanical properties has great potential to advance vision science research and improve the clinical management of glaucoma patients.
- Open Access
- 14 March 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12354, 18-21
The effects of epinephrine on ciliary beat frequency in human sinonasal mucosa
Mucociliary clearance is an important physiological mechanism for clearing the upper airways. Previously, it has been shown that different disease processes and drugs affect ciliary beat frequency (CBF). Namely, epinephrine has been shown to accelerate CBF in various animal models. Additionally, phase contrast microscopy (PCM) and spectrally encoded interferometric microscopy (SEIM) have been used to image dynamic tissue of the upper airway. Herein, we explore the effects of epinephrine on human sinonasal mucosa through PCM and SEIM. Sinonasal mucosa was harvested from patients undergoing endoscopic sinus surgery (ESS). Tissue was imaged using PCM and SEIM, maintaining physiological temperature through the use of warmed HBSS and a heating plate. Videos were taken before addition of any drugs as baseline. Epinephrine was diluted to 1 mg/mL (1:1000) and 1mL of solution was introduced to the sinonasal mucosa. PCM and SEIM was performed after to determine effects of epinephrine on CBF. Data analysis was performed using MATLAB (Mathworks, Natick, Massachusetts). Human sinonasal mucosa, taken from various anatomic locations, showed CBF values on PCM and SEIM consistent with what has been shown in previous literature. Upon addition of epinephrine to sinonasal mucosa, a marked increase in CBF was observed in both PCM and SEIM. In conclusion, the addition of epinephrine to sinonasal mucosa increased ciliary beat frequency. This validates the use of SEIM for determining CBF in sinonasal tissues. Further studies include adding to our sample size to determine a more accurate magnitude of increase of CBF.
- 14 March 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12354, 18-21
Open AccessThe effects of epinephrine on ciliary beat frequency in human sinonasal mucosa
Mucociliary clearance is an important physiological mechanism for clearing the upper airways. Previously, it has been shown that different disease processes and drugs affect ciliary beat frequency (CBF). Namely, epinephrine has been shown to accelerate CBF in various animal models. Additionally, phase contrast microscopy (PCM) and spectrally encoded interferometric microscopy (SEIM) have been used to image dynamic tissue of the upper airway. Herein, we explore the effects of epinephrine on human sinonasal mucosa through PCM and SEIM. Sinonasal mucosa was harvested from patients undergoing endoscopic sinus surgery (ESS). Tissue was imaged using PCM and SEIM, maintaining physiological temperature through the use of warmed HBSS and a heating plate. Videos were taken before addition of any drugs as baseline. Epinephrine was diluted to 1 mg/mL (1:1000) and 1mL of solution was introduced to the sinonasal mucosa. PCM and SEIM was performed after to determine effects of epinephrine on CBF. Data analysis was performed using MATLAB (Mathworks, Natick, Massachusetts). Human sinonasal mucosa, taken from various anatomic locations, showed CBF values on PCM and SEIM consistent with what has been shown in previous literature. Upon addition of epinephrine to sinonasal mucosa, a marked increase in CBF was observed in both PCM and SEIM. In conclusion, the addition of epinephrine to sinonasal mucosa increased ciliary beat frequency. This validates the use of SEIM for determining CBF in sinonasal tissues. Further studies include adding to our sample size to determine a more accurate magnitude of increase of CBF.
- 5 March 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11620, 1162007-5
In-vivo analysis of acute chlorine gas inhalation injury using optical coherence tomography (OCT) in rabbit model
In this work, we demonstrate the ability to image and quantify airway changes, edema, and epithelial layer separation using OCT and automated tissue boundary identification in the rabbit large airways as early as 30-minutes post-chlorine gas exposure. We propose this novel approach will enable further investigations into using OCT for pre-hospital and point-of-care diagnostics of large airway injury due to airway toxic chemical exposure. With enhanced portability over conventional bronchoscopy, we believe our system is capable of field hospital deployment and investigating airway conditions in warfighters. Combining OCT with bronchoscopy would enhance the assessment and treatment of large airway chemical injury.
- 5 March 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11620, 1162007-5
In-vivo analysis of acute chlorine gas inhalation injury using optical coherence tomography (OCT) in rabbit model
In this work, we demonstrate the ability to image and quantify airway changes, edema, and epithelial layer separation using OCT and automated tissue boundary identification in the rabbit large airways as early as 30-minutes post-chlorine gas exposure. We propose this novel approach will enable further investigations into using OCT for pre-hospital and point-of-care diagnostics of large airway injury due to airway toxic chemical exposure. With enhanced portability over conventional bronchoscopy, we believe our system is capable of field hospital deployment and investigating airway conditions in warfighters. Combining OCT with bronchoscopy would enhance the assessment and treatment of large airway chemical injury.
- 1 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1983-1989
A Partial Sparsification Scheme for Visual-Inertial Odometry
In this paper, we present a partial sparsification scheme for the marginalization of visual inertial odometry (VIO) systems. Sliding window optimization is widely used in VIO systems to guarantee constant complexity by optimizing over a set of recent states and marginalizing out past ones. The marginalization step introduces fill-in between variables incident to the marginalized ones, and most VIO systems discard measurements targeted at active landmark points to maintain sparsity of the marginalized information matrix, at the expense of potential information loss. The scheme is to first retain the dense prior from the marginalization excluding visual measurements, followed by a dense marginalization step that connects landmarks. The dense marginalization prior is then partially sparsified to extract pseudo factors that maintain the overall sparsity while minimizing the information loss. The proposed scheme is tested on public datasets and achieves appreciable results compared with several state-of-the-art approaches. The test also demonstrates that our scheme is applicable to real-time operations.
- 1 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1983-1989
A Partial Sparsification Scheme for Visual-Inertial Odometry
In this paper, we present a partial sparsification scheme for the marginalization of visual inertial odometry (VIO) systems. Sliding window optimization is widely used in VIO systems to guarantee constant complexity by optimizing over a set of recent states and marginalizing out past ones. The marginalization step introduces fill-in between variables incident to the marginalized ones, and most VIO systems discard measurements targeted at active landmark points to maintain sparsity of the marginalized information matrix, at the expense of potential information loss. The scheme is to first retain the dense prior from the marginalization excluding visual measurements, followed by a dense marginalization step that connects landmarks. The dense marginalization prior is then partially sparsified to extract pseudo factors that maintain the overall sparsity while minimizing the information loss. The proposed scheme is tested on public datasets and achieves appreciable results compared with several state-of-the-art approaches. The test also demonstrates that our scheme is applicable to real-time operations.
- Open Access
Integrated pulse scope for tunable generation and intrinsic characterization of structured femtosecond laser
Numerous techniques have been demonstrated for effective generation of orbital angular momentum-carrying radiation, but intracavity generation of continuously tunable pulses in the femtosecond regime remains challenging. Even if such a creation was realized, the generated pulses, like all pulses in reality, are complex and transitory objects that can only be comprehensively characterized via multidimensional spaces. An integrated lasing system that generates pulses while simultaneously quantifies them can achieve adaptive pulse tailoring. Here, we report a femtosecond pulse scope that unifies vector vortex mode-locked lasing and vectorial quantification. With intracavity-controlled Pancharatnam-Berry phase modulation, continuous and ergodic generation of spirally polarized states along a broadband higher-order Poincare sphere was realized. By intrinsically coupling a two-dimensional polarization-sensitive time-scanning interferometer to the laser, multidimensional spatiotemporal features of the pulse were further visualized. The proposed methodology paves the way for design optimization of ultrafast optics by integrating complex femtosecond pulse generation and structural customization, facilitating its applications in optical physics research and laser-based manufacturing.
Open AccessIntegrated pulse scope for tunable generation and intrinsic characterization of structured femtosecond laser
Numerous techniques have been demonstrated for effective generation of orbital angular momentum-carrying radiation, but intracavity generation of continuously tunable pulses in the femtosecond regime remains challenging. Even if such a creation was realized, the generated pulses, like all pulses in reality, are complex and transitory objects that can only be comprehensively characterized via multidimensional spaces. An integrated lasing system that generates pulses while simultaneously quantifies them can achieve adaptive pulse tailoring. Here, we report a femtosecond pulse scope that unifies vector vortex mode-locked lasing and vectorial quantification. With intracavity-controlled Pancharatnam-Berry phase modulation, continuous and ergodic generation of spirally polarized states along a broadband higher-order Poincare sphere was realized. By intrinsically coupling a two-dimensional polarization-sensitive time-scanning interferometer to the laser, multidimensional spatiotemporal features of the pulse were further visualized. The proposed methodology paves the way for design optimization of ultrafast optics by integrating complex femtosecond pulse generation and structural customization, facilitating its applications in optical physics research and laser-based manufacturing.