Ricardo Teixeira Abreu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ricardo Teixeira Abreu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Renato Luiz Maia Nogueira
Department of Dental Clinic, Discipline of Oral and Maxillofacial Surgery and Stomatology, Federal University of Ceará, School of Dentistry, Fortaleza, Ceará, Brazil
3 shared publications- Aloísio Oro Spazzin
Atitus Educação, Brazil
2 shared publications Marcelo F. Mesquita
Department of Prosthodontics and Periodontics, Piracicaba Dental School, State University of Campinas, Piracicaba, Brazil
2 shared publicationsPedro Y. Noritomi
Renato Archer Technology Information Center, Products Development Division, Campinas, Brazil
2 shared publicationsRafael Leonardo X. Consani
Department of Prosthodontics and Periodontics, Piracicaba Dental School, State University of Campinas, Piracicaba, Brazil
2 shared publications- Rafael Lima Verde Osterne
Assistant Professor, Department of Pathology, Fortaleza University School of Medicine, Fortaleza, Brazil; PhD Student, Federal University of Ceara School of Dentistry, Fortaleza, Brazil
2 shared publications
Latest Publications
- 30 April 2023
- Published by Dental Press International in Journal of Clinical Dentistry and Research
- Vol. 20 (1)
Reabilitação oral usando planejamento digital e CAD/CAM com blocos de resina composta
Bem vindo ao DentalGO a plataforma online dos melhores dentistas
- 30 April 2023
- Published by Dental Press International in Journal of Clinical Dentistry and Research
- Vol. 20 (1)
Reabilitação oral usando planejamento digital e CAD/CAM com blocos de resina composta
Bem vindo ao DentalGO a plataforma online dos melhores dentistas
- 19 September 2018
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 20 (6) , 915-922
A retrospective study of an alternative technique for implant repositioning in the maxillary esthetic region
Background Implant‐bone block segment repositioning may be an option of treatment for patients with vertical alveolar bone atrophy. Purpose To assess implant‐bone block movement, gingival outcome and the subjective appreciation of patients after an alternative treatment of an implant‐bone block segment repositioning in the maxillary esthetic region. Materials and Methods Patients who underwent implant‐bone block segment relocation in areas of vertical alveolar bone atrophy in the anterior esthetic region were assessed. The outcome measures were implant failure, complications after initial loading, vertical bone augmentation, papilla index, width of the keratinized mucosa, and patient satisfaction. Results Twenty‐five implants in nine consecutive patients were included in this study. During the follow‐up period, only one implant failed. Vertical bone augmentation ranged from 3.0 to 8.4 mm (mean 4.9 mm). A significant improvement (P < .001) in the papilla index was observed, improving the esthetic outcome. Six patients (66.6%) had more than 2 mm of keratinized mucosa and all of the patients were satisfied with the treatment. Conclusions The esthetics and functional gingival outcome of oral rehabilitation in areas with vertical alveolar bone atrophy can be successfully improved with the presented technique, which had a high overall implant survival rate within a short period.
- 19 September 2018
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 20 (6) , 915-922
A retrospective study of an alternative technique for implant repositioning in the maxillary esthetic region
Background Implant‐bone block segment repositioning may be an option of treatment for patients with vertical alveolar bone atrophy. Purpose To assess implant‐bone block movement, gingival outcome and the subjective appreciation of patients after an alternative treatment of an implant‐bone block segment repositioning in the maxillary esthetic region. Materials and Methods Patients who underwent implant‐bone block segment relocation in areas of vertical alveolar bone atrophy in the anterior esthetic region were assessed. The outcome measures were implant failure, complications after initial loading, vertical bone augmentation, papilla index, width of the keratinized mucosa, and patient satisfaction. Results Twenty‐five implants in nine consecutive patients were included in this study. During the follow‐up period, only one implant failed. Vertical bone augmentation ranged from 3.0 to 8.4 mm (mean 4.9 mm). A significant improvement (P < .001) in the papilla index was observed, improving the esthetic outcome. Six patients (66.6%) had more than 2 mm of keratinized mucosa and all of the patients were satisfied with the treatment. Conclusions The esthetics and functional gingival outcome of oral rehabilitation in areas with vertical alveolar bone atrophy can be successfully improved with the presented technique, which had a high overall implant survival rate within a short period.
- 1 July 2017
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 75 (7) , 1402.e1-1402.e8
Alternative Distraction Osteogenesis Technique After Implant Placement for Alveolar Ridge Augmentation of the Maxilla
- 1 July 2017
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 75 (7) , 1402.e1-1402.e8
Alternative Distraction Osteogenesis Technique After Implant Placement for Alveolar Ridge Augmentation of the Maxilla
- 1 December 2016
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 74 (12) , 2567.e1-2567.e10
Surgical Treatment, Oral Rehabilitation, and Orthognathic Surgery After Failure of Pharmacologic Treatment of Central Giant Cell Lesion: A Case Report
- 1 December 2016
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 74 (12) , 2567.e1-2567.e10
Surgical Treatment, Oral Rehabilitation, and Orthognathic Surgery After Failure of Pharmacologic Treatment of Central Giant Cell Lesion: A Case Report
- 9 June 2011
- Published by Wiley in Journal of Prosthodontics
- Vol. 20 (4) , 280-285
Evaluation of Stress Distribution in Overdenture-Retaining Bar with Different Levels of Vertical Misfit
To evaluate the effects of different levels of vertical misfit between implant and bar framework on distribution of static stresses in an overdenture-retaining bar system using finite element analysis. A 3D finite element model (11,718 elements and 21,625 nodes) was created and included two titanium implants and a bar framework placed in the medial region of the anterior part of a severely reabsorbed-jaw. All materials were presumed to be linear elastic, homogenous, and isotropic. Mechanical simulation software (NEiNastran 9.0) was used, where displacements were applied on the end of the bar framework to simulate the closure of the vertical misfits (5, 25, 50, 100, 200, and 300 μm) after tightening of the screws. Data were qualitatively evaluated using Von Mises stress given by the software. The models showed stress concentration in cortical bone, corresponding to the cervical part of the implant, and in cancellous bone, corresponding to the apical part of the implant; however, in these regions few changes were observed in stress to the misfits studied. While in the bar framework, retaining-screw neck, and implant platform, a considerable stress increase proportional to the misfit amplification was observed. The different levels of vertical misfit did not considerably influence the static stress levels in the peri-implant bone tissue; however, the mechanical components of the overdenture-retaining bar system are more sensitive to lack of passive fit.
- 9 June 2011
- Published by Wiley in Journal of Prosthodontics
- Vol. 20 (4) , 280-285
Evaluation of Stress Distribution in Overdenture-Retaining Bar with Different Levels of Vertical Misfit
To evaluate the effects of different levels of vertical misfit between implant and bar framework on distribution of static stresses in an overdenture-retaining bar system using finite element analysis. A 3D finite element model (11,718 elements and 21,625 nodes) was created and included two titanium implants and a bar framework placed in the medial region of the anterior part of a severely reabsorbed-jaw. All materials were presumed to be linear elastic, homogenous, and isotropic. Mechanical simulation software (NEiNastran 9.0) was used, where displacements were applied on the end of the bar framework to simulate the closure of the vertical misfits (5, 25, 50, 100, 200, and 300 μm) after tightening of the screws. Data were qualitatively evaluated using Von Mises stress given by the software. The models showed stress concentration in cortical bone, corresponding to the cervical part of the implant, and in cancellous bone, corresponding to the apical part of the implant; however, in these regions few changes were observed in stress to the misfits studied. While in the bar framework, retaining-screw neck, and implant platform, a considerable stress increase proportional to the misfit amplification was observed. The different levels of vertical misfit did not considerably influence the static stress levels in the peri-implant bone tissue; however, the mechanical components of the overdenture-retaining bar system are more sensitive to lack of passive fit.
- 2 August 2010
- Published by Wiley in Journal of Prosthodontics
- Vol. 19 (6) , 425-431
Influence of Material of Overdenture‐Retaining Bar with Vertical Misfit on Three‐Dimensional Stress Distribution
Purpose: This study evaluated the effects of different bar materials on stress distribution in an overdenture‐retaining bar system with a vertical misfit between implant and bar framework. Materials and Methods: A three‐dimentional finite element model was created including two titanium implants and a bar framework placed in the anterior part of a severely reabsorbed jaw. The model set was exported to mechanical simulation software, where displacement was applied to simulate the screw torque limited by 100‐μm vertical misfit. Four bar materials (gold alloy, silver‐palladium alloy, commercially pure titanium, cobalt‐chromium alloy) were simulated in the analysis. Data were qualitatively evaluated using Von Mises stress given by the software. Results: The models showed stress concentration in cortical bone corresponding to the cervical part of the implant, and in cancellous bone corresponding to the apical part of the implant; however, in these regions few changes were observed in the levels of stress on the different bar materials analyzed. In the bar framework, screw, and implant, considerable increase in stress was observed when the elastic modulus of the bar material was increased. Conclusions: The different materials of the overdenture‐retaining bar did not present considerable influence on the stress levels in the periimplant bone tissue, while the mechanical components of the system were more sensitive to the material stiffness.
- 2 August 2010
- Published by Wiley in Journal of Prosthodontics
- Vol. 19 (6) , 425-431
Influence of Material of Overdenture‐Retaining Bar with Vertical Misfit on Three‐Dimensional Stress Distribution
Purpose: This study evaluated the effects of different bar materials on stress distribution in an overdenture‐retaining bar system with a vertical misfit between implant and bar framework. Materials and Methods: A three‐dimentional finite element model was created including two titanium implants and a bar framework placed in the anterior part of a severely reabsorbed jaw. The model set was exported to mechanical simulation software, where displacement was applied to simulate the screw torque limited by 100‐μm vertical misfit. Four bar materials (gold alloy, silver‐palladium alloy, commercially pure titanium, cobalt‐chromium alloy) were simulated in the analysis. Data were qualitatively evaluated using Von Mises stress given by the software. Results: The models showed stress concentration in cortical bone corresponding to the cervical part of the implant, and in cancellous bone corresponding to the apical part of the implant; however, in these regions few changes were observed in the levels of stress on the different bar materials analyzed. In the bar framework, screw, and implant, considerable increase in stress was observed when the elastic modulus of the bar material was increased. Conclusions: The different materials of the overdenture‐retaining bar did not present considerable influence on the stress levels in the periimplant bone tissue, while the mechanical components of the system were more sensitive to the material stiffness.