Svjetlana Grbac Ivankovic
Svjetlana Grbac Ivankovic has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Neva Girotto
Department of Nuclear Medicine, Clinical Hospital Centre Rijeka, Faculty of Medicine, University of Rijeka, Croatia
2 shared publications - Aleksandar Smokvina
Department of Nuclear Medicine, University Hospital Center Rijeka, Rijeka, Croatia
1 shared publication Anita Tabain
1 shared publicationAntonija Balenovic
1 shared publicationDavor Jurisic
Clin Hosp Ctr Rijeka, Dept Surg, Rijeka, Croatia
1 shared publication- Gordana Brumini
University of Rijeka
1 shared publication
Latest Publications
- 1 March 2019
- Published by University of Rijeka, Faculty of Medicine in Medicina Fluminensis
- Vol. 55 (1) , 59-64
The role of 99mTc-MIBI in the evaluation of non-functional thyroid gland nodules
- 1 March 2019
- Published by University of Rijeka, Faculty of Medicine in Medicina Fluminensis
- Vol. 55 (1) , 59-64
The role of 99mTc-MIBI in the evaluation of non-functional thyroid gland nodules
- 1 January 2017
- Vol. 25 (2) , 99-106
Predictive Value of Intraoperative Sentinel Lymph Node Imprint Cytology Analysis fir Metastasis in Patients with Melanoma
Since there are no standardized protocols regarding the detection of microscopic melanoma deposits in sentinel lymph nodes (SLN), the aim of this study was to present our experience with intraoperative cytological evaluation of SLN in patients with melanoma. The study included 475 SLN biopsies (SLNB) from 201 patients with primary cutaneous melanoma of intermediate thickness. Each lymph node was cut in half; touch imprint cytology (TIC) preparations of all cut surfaces were performed and stained according to a modified May-Grunwald-Giemsa method. The results were compared to definitive postoperative histology. Twenty of 25 SLNB positive on TIC proved to be metastatic when compared to definitive histology. Most of 32 SLN that were suspicious but not diagnostic on TIC were proven negative (23/32, 71.8%), while 7 nodes had metastases (one micrometastasis and one with isolated tumor cells only). The majority (94%) of SLNBs negative on TIC remained negative on final histology, while 6% or 25 nodes were positive, mostly with micrometastases or isolated tumor cells (17/25). In frozen sections performed in cases of suspicious or positive SLN cytology, metastasis was confirmed in 80% of positive and in 21.9% of suspicious TIC. Altogether, 49% (27/55) of positive SLNB were identified intraoperatively in 57% (24/42) of patients, and in those cases a complete regional lymph node dissection was performed in the first step. TIC assessment of SLNB with 99% specificity and 57% sensitivity for intraoperative identification of metastasis is useful and beneficial for avoiding a second operative procedure.
- 1 January 2017
- Vol. 25 (2) , 99-106
Predictive Value of Intraoperative Sentinel Lymph Node Imprint Cytology Analysis fir Metastasis in Patients with Melanoma
Since there are no standardized protocols regarding the detection of microscopic melanoma deposits in sentinel lymph nodes (SLN), the aim of this study was to present our experience with intraoperative cytological evaluation of SLN in patients with melanoma. The study included 475 SLN biopsies (SLNB) from 201 patients with primary cutaneous melanoma of intermediate thickness. Each lymph node was cut in half; touch imprint cytology (TIC) preparations of all cut surfaces were performed and stained according to a modified May-Grunwald-Giemsa method. The results were compared to definitive postoperative histology. Twenty of 25 SLNB positive on TIC proved to be metastatic when compared to definitive histology. Most of 32 SLN that were suspicious but not diagnostic on TIC were proven negative (23/32, 71.8%), while 7 nodes had metastases (one micrometastasis and one with isolated tumor cells only). The majority (94%) of SLNBs negative on TIC remained negative on final histology, while 6% or 25 nodes were positive, mostly with micrometastases or isolated tumor cells (17/25). In frozen sections performed in cases of suspicious or positive SLN cytology, metastasis was confirmed in 80% of positive and in 21.9% of suspicious TIC. Altogether, 49% (27/55) of positive SLNB were identified intraoperatively in 57% (24/42) of patients, and in those cases a complete regional lymph node dissection was performed in the first step. TIC assessment of SLNB with 99% specificity and 57% sensitivity for intraoperative identification of metastasis is useful and beneficial for avoiding a second operative procedure.
- 1 June 2014
- Vol. 38 (2) , 547-52
The evolvement of the renographic curve pattern in early childhood.
The purpose of this study was to evaluate renographic parameters obtained from healthy renal units (RUs) in newborns and infants with unilateral kidney condition. Thirty three children including twenty newborns, referred to Technetium-99m mercaptoacetyltriglycine (Tc-99m MAG3) diuretic scintigraphy due to unilateral kidney condition entered the study. Only contralateral, healthy RUs were analyzed. Since many children returned for follow up, there were altogether 78 dynamic studies included. Kidney length was compared to ultrasound measurements. Renographic curve parameters (time to maximum counts, T max and time to half maximum counts, T1/2 max) were evaluated. The results showed that the kidney length measured on Tc-99m MAG3 scintigraphy correlated well with ultrasound measurements. Regarding the renographic curve parameters, in the newborn period a significantly shorter T max (mean T max 3.65 +/- 1.2 min, p = 0.026) was found compared to the group of two months old infants (5.12 +/- 2.2 min). In older age groups mean T max gradually shortened again. On the contrary, T1/2 max was significantly longer in newborn and early infant period than in older age groups (16.7 +/- 8.2 min, p = 0.018), but generally showed variable values until the age of three years. It can be concluded that it is important to be aware of possible diversities of renographic curve pattern of healthy kidneys in early childhood, especially in the elimination part. Therefore, when interpreting a dynamic renal study, one should also consider other parameters like kidney growth, morphology and differential function, which can be reliably monitored with repeated Tc-99m MAG3 scintigraphy, to discern between normal and pathologic finding.
- 1 June 2014
- Vol. 38 (2) , 547-52
The evolvement of the renographic curve pattern in early childhood.
The purpose of this study was to evaluate renographic parameters obtained from healthy renal units (RUs) in newborns and infants with unilateral kidney condition. Thirty three children including twenty newborns, referred to Technetium-99m mercaptoacetyltriglycine (Tc-99m MAG3) diuretic scintigraphy due to unilateral kidney condition entered the study. Only contralateral, healthy RUs were analyzed. Since many children returned for follow up, there were altogether 78 dynamic studies included. Kidney length was compared to ultrasound measurements. Renographic curve parameters (time to maximum counts, T max and time to half maximum counts, T1/2 max) were evaluated. The results showed that the kidney length measured on Tc-99m MAG3 scintigraphy correlated well with ultrasound measurements. Regarding the renographic curve parameters, in the newborn period a significantly shorter T max (mean T max 3.65 +/- 1.2 min, p = 0.026) was found compared to the group of two months old infants (5.12 +/- 2.2 min). In older age groups mean T max gradually shortened again. On the contrary, T1/2 max was significantly longer in newborn and early infant period than in older age groups (16.7 +/- 8.2 min, p = 0.018), but generally showed variable values until the age of three years. It can be concluded that it is important to be aware of possible diversities of renographic curve pattern of healthy kidneys in early childhood, especially in the elimination part. Therefore, when interpreting a dynamic renal study, one should also consider other parameters like kidney growth, morphology and differential function, which can be reliably monitored with repeated Tc-99m MAG3 scintigraphy, to discern between normal and pathologic finding.
- 1 January 2012
- Published by National Library of Serbia in Archive of Oncology
- Vol. 20 (3-4) , 97-102
PET/CT in renal and bladder cancers
- 1 January 2012
- Published by National Library of Serbia in Archive of Oncology
- Vol. 20 (3-4) , 97-102
PET/CT in renal and bladder cancers