Orren D. Schneider
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Orren D. Schneider has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Lauren A. Weinrich
American Water Voorhees N.J.
3 shared publicationsDavid M. Hughes
2 shared publicationsJian Yang
2 shared publicationsMark W. LeChevallier
2 shared publications- Mark W. LeChevallier
American Water, 1025 Laurel Oak Road, Voorhees, NJ 08043
2 shared publications Mark W. Lechevallier
American Water Works Co. Voorhees N.J.
2 shared publications
Latest Publications
- 1 March 2017
- Published by Wiley in Journal AWWA
- Vol. 109 (3) , 39-47
A Cost-Effective Treatment Process for Producing High-Quality Drinking Water
- 1 March 2017
- Published by Wiley in Journal AWWA
- Vol. 109 (3) , 39-47
A Cost-Effective Treatment Process for Producing High-Quality Drinking Water
- 1 October 2015
- Published by Wiley in Journal AWWA
- Vol. 107 (10)
Ultrasonic Treatment of Algae in a New Jersey Reservoir
A system of ultrasonic buoys was installed in the Canoe Brook Reservoir 1 in Short Hills, N.J., to assess the impact of the system on controlling algae and cyanobacteria in the reservoir. The four buoys operated for five months in spring/summer 2014. The results of the study indicated that the ultrasonic system was effective for controlling algae when the correct ultrasonic program was used. During the testing period, geosmin and methyl isoborneol concentrations were well controlled. Additionally, the average alum dose used by the plant was reduced by 22% compared with the same period in 2013, with improved dissolved air flotation effluent turbidity and combined filter effluent turbidity and an 83% increase in unit filter run volumes. An economic assessment showed the buoys saved approximately $87,800 in operational costs, with a projected simple payback time of 1.8 years for the system.
- 1 October 2015
- Published by Wiley in Journal AWWA
- Vol. 107 (10)
Ultrasonic Treatment of Algae in a New Jersey Reservoir
A system of ultrasonic buoys was installed in the Canoe Brook Reservoir 1 in Short Hills, N.J., to assess the impact of the system on controlling algae and cyanobacteria in the reservoir. The four buoys operated for five months in spring/summer 2014. The results of the study indicated that the ultrasonic system was effective for controlling algae when the correct ultrasonic program was used. During the testing period, geosmin and methyl isoborneol concentrations were well controlled. Additionally, the average alum dose used by the plant was reduced by 22% compared with the same period in 2013, with improved dissolved air flotation effluent turbidity and combined filter effluent turbidity and an 83% increase in unit filter run volumes. An economic assessment showed the buoys saved approximately $87,800 in operational costs, with a projected simple payback time of 1.8 years for the system.
- 1 February 2015
- Published by Wiley in Journal AWWA
- Vol. 107 (2) , E97-E108
Microbial Risk Modeling for Main Breaks
A microbial risk model was developed for main breaks to evaluate the impact of flushing and disinfection as needed to mitigate the potential contamination risk. Of protozoan, virus, and bacterial risks examined, estimated risks from viruses were the highest, suggesting a 7‐log reduction to achieve a 1/10,000 risk target. To accomplish this level of risk reduction, it was necessary to use a flushing velocity of at least 3 ft/s and disinfection with a free chlorine CT (disinfectant concentration multiplied by time) of at least 100 mg × min/L. The risk model also sheds light on alternative risk management options, the impact of specific field conditions, and potential for future model improvements.
- 1 February 2015
- Published by Wiley in Journal AWWA
- Vol. 107 (2) , E97-E108
Microbial Risk Modeling for Main Breaks
A microbial risk model was developed for main breaks to evaluate the impact of flushing and disinfection as needed to mitigate the potential contamination risk. Of protozoan, virus, and bacterial risks examined, estimated risks from viruses were the highest, suggesting a 7‐log reduction to achieve a 1/10,000 risk target. To accomplish this level of risk reduction, it was necessary to use a flushing velocity of at least 3 ft/s and disinfection with a free chlorine CT (disinfectant concentration multiplied by time) of at least 100 mg × min/L. The risk model also sheds light on alternative risk management options, the impact of specific field conditions, and potential for future model improvements.
- 1 September 2013
- Published by IWA Publishing in Journal of Water Supply: Research and Technology—AQUA
- Vol. 62 (6) , 339-349
Impacts of salt type and concentration on coagulation of humic acid and silica
- 1 September 2013
- Published by IWA Publishing in Journal of Water Supply: Research and Technology—AQUA
- Vol. 62 (6) , 339-349
Impacts of salt type and concentration on coagulation of humic acid and silica
- 1 January 2012
- Published by Wiley in Journal AWWA
- Vol. 104 (1) , 37
Effect of zinc and orthophosphate corrosion inhibitors on cement‐based pipes
- 1 January 2012
- Published by Wiley in Journal AWWA
- Vol. 104 (1) , 37
Effect of zinc and orthophosphate corrosion inhibitors on cement‐based pipes
- Open Access
- 1 February 2011
- Published by American Society for Microbiology in Applied and Environmental Microbiology
- Vol. 77 (3) , 1148-1150
Bioluminescence-Based Method for Measuring Assimilable Organic Carbon in Pretreatment Water for Reverse Osmosis Membrane Desalination
A bioluminescence-based assimilable organic carbon (AOC) test was developed for determining the biological growth potential of seawater within the reverse osmosis desalination pretreatment process. The test uses Vibrio harveyi , a marine organism that exhibits constitutive luminescence and is nutritionally robust. AOC was measured in both a pilot plant and a full-scale desalination plant pretreatment.
- 1 February 2011
- Published by American Society for Microbiology in Applied and Environmental Microbiology
- Vol. 77 (3) , 1148-1150
Open AccessBioluminescence-Based Method for Measuring Assimilable Organic Carbon in Pretreatment Water for Reverse Osmosis Membrane Desalination
A bioluminescence-based assimilable organic carbon (AOC) test was developed for determining the biological growth potential of seawater within the reverse osmosis desalination pretreatment process. The test uses Vibrio harveyi , a marine organism that exhibits constitutive luminescence and is nutritionally robust. AOC was measured in both a pilot plant and a full-scale desalination plant pretreatment.
- 1 August 2010
- Published by Wiley in Journal AWWA
- Vol. 102 (8) , 52-63
Determining vulnerability and occurrence of residential backflow
- 1 August 2010
- Published by Wiley in Journal AWWA
- Vol. 102 (8) , 52-63
Determining vulnerability and occurrence of residential backflow
- 1 November 2007
- Published by Wiley in Journal AWWA
- Vol. 99 (11) , 103-113
A comparison of zinc and nonzinc orthophosphate‐based corrosion control
American Water has orthophosphate‐based corrosion control programs at 78 treatment facilities, with zinc orthophosphate accounting for 88% of these programs. Many communities nationwide use zinc orthophosphate despite its expense and environmental concerns about zinc in wastewater sludge. The yearly use of zinc‐containing corrosion inhibitors in American Water systems accounts for more than 500,000 lb of zinc. Corrosion inhibitors that contain orthophosphate but offer an alternative to zinc orthophosphate include orthophosphoric acid and calcium or sodium orthophosphate salts. In this study, pilot‐testing of corrosion inhibitors with and without zinc was conducted using new metal coupons; results indicated that zinc does not play an important role in corrosion control. This testing indicates that a change from zinc orthophosphate to reduced concentrations of zinc in orthophosphate‐based corrosion inhibitors or orthophosphoric acid will not affect corrosion rates of lead or copper piping, will reduce the burden of removing excessive zinc from wastewater, and can reduce operational costs.
- 1 November 2007
- Published by Wiley in Journal AWWA
- Vol. 99 (11) , 103-113
A comparison of zinc and nonzinc orthophosphate‐based corrosion control
American Water has orthophosphate‐based corrosion control programs at 78 treatment facilities, with zinc orthophosphate accounting for 88% of these programs. Many communities nationwide use zinc orthophosphate despite its expense and environmental concerns about zinc in wastewater sludge. The yearly use of zinc‐containing corrosion inhibitors in American Water systems accounts for more than 500,000 lb of zinc. Corrosion inhibitors that contain orthophosphate but offer an alternative to zinc orthophosphate include orthophosphoric acid and calcium or sodium orthophosphate salts. In this study, pilot‐testing of corrosion inhibitors with and without zinc was conducted using new metal coupons; results indicated that zinc does not play an important role in corrosion control. This testing indicates that a change from zinc orthophosphate to reduced concentrations of zinc in orthophosphate‐based corrosion inhibitors or orthophosphoric acid will not affect corrosion rates of lead or copper piping, will reduce the burden of removing excessive zinc from wastewater, and can reduce operational costs.
- 1 July 2004
- Published by Wiley in Journal AWWA
- Vol. 96 (7) , 66-74
Hindsight Is 20/20: Using History to Avoid Waterborne Disease Outbreaks
Despite strenuous efforts to prevent them, waterborne disease outbreaks continue to occur from time to time in countries that have the knowledge and capability to prevent them. This article presents the concept that multiple adverse events or changes can often be associated with waterborne disease outbreaks. The information in this article is designed to encourage water treatment plant operators, water quality supervisors, and plant managers to maintain vigilance at all times so circumstances that might lead to a treatment failure and a disease outbreak can be avoided. The authors discuss the importance of water treatment plant personnel being alert at all times and remaining watchful for changes in source water quality, changes in treated water quality, or both to help minimize the likelihood of future waterborne disease outbreaks.
- 1 July 2004
- Published by Wiley in Journal AWWA
- Vol. 96 (7) , 66-74
Hindsight Is 20/20: Using History to Avoid Waterborne Disease Outbreaks
Despite strenuous efforts to prevent them, waterborne disease outbreaks continue to occur from time to time in countries that have the knowledge and capability to prevent them. This article presents the concept that multiple adverse events or changes can often be associated with waterborne disease outbreaks. The information in this article is designed to encourage water treatment plant operators, water quality supervisors, and plant managers to maintain vigilance at all times so circumstances that might lead to a treatment failure and a disease outbreak can be avoided. The authors discuss the importance of water treatment plant personnel being alert at all times and remaining watchful for changes in source water quality, changes in treated water quality, or both to help minimize the likelihood of future waterborne disease outbreaks.