D. G. Leo Samuel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
D. G. Leo Samuel has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Mp Maiya
Indian Institute of Technology Madras
9 shared publications S. M. Shiva Nagendra
Indian Institute of Technology Madras
3 shared publicationsS.M. Shiva Nagendra
2 shared publicationsAdil Eshack
1 shared publicationK. Dharmasastha
1 shared publicationS M Shiva Nagendra
Indian Institute of Technology Madras
1 shared publication
Latest Publications
- 1 February 2019
- Published by Springer Nature in Sādhanā
- Vol. 44 (2) , 48
A sensitivity analysis of the design parameters for thermal comfort of thermally activated building system
- 1 February 2019
- Published by Springer Nature in Sādhanā
- Vol. 44 (2) , 48
A sensitivity analysis of the design parameters for thermal comfort of thermally activated building system
- 22 December 2017
- Published by Springer Nature in MAPAN
- Vol. 33 (2) , 147-158
Cooling Performance and Indoor Air Quality Characteristics of an Earth Air Tunnel Cooled Building
- 22 December 2017
- Published by Springer Nature in MAPAN
- Vol. 33 (2) , 147-158
Cooling Performance and Indoor Air Quality Characteristics of an Earth Air Tunnel Cooled Building
- Open Access
- 1 December 2017
- Published by Elsevier in International Journal of Sustainable Built Environment
- Vol. 6 (2) , 463-475
Thermal comfort in traditional buildings composed of local and modern construction materials
- 1 December 2017
- Published by Elsevier in International Journal of Sustainable Built Environment
- Vol. 6 (2) , 463-475
Open AccessThermal comfort in traditional buildings composed of local and modern construction materials
- 1 November 2017
- Published by Elsevier in Energy and Buildings
- Vol. 155, 352-363
Feasibility analysis of passive thermally activated building system for various climatic regions in India
- 1 November 2017
- Published by Elsevier in Energy and Buildings
- Vol. 155, 352-363
Feasibility analysis of passive thermally activated building system for various climatic regions in India
- 10 May 2017
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 27 (9) , 1175-1186
An analysis of operating parameters in the cooling tower-based thermally activated building system
Thermally activated building system is not only energy efficient but also provides better thermal comfort compared to the conventional cooling systems. In this paper, COMSOL Multiphysics, a computational fluid dynamics tool, is used to simulate the performance of a cooling tower coupled with thermally activated building system for the hot and dry summer climatic conditions of New Delhi. The effects of three operating parameters, namely, temperature and inlet velocity of water and the number of cooling surfaces (area), on the performance of the system have been investigated. The results indicate that increasing the water inlet temperature from wet bulb temperature (WBT) to WBT + 6℃ would increase the operative temperature of the indoor space, a thermal comfort index, by 2℃. The increase in water inlet velocity from 0.2 to 1 m/s would decrease the diurnal average of operative temperature by 1.4℃. If only the roof was cooled, the diurnal average of operative temperature was 36.7℃. The diurnal average of operative temperature was reduced by 5.7℃ if all the building fabrics were cooled. In this case, with pipes connected in series from the floor first to walls and then to roof resulted in 2.9℃ lower operative temperature compared to that in the reverse sequence. Hence, the sequence in which the fabrics are cooled would have an appreciable influence on the performance of thermally activated building system.
- 10 May 2017
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 27 (9) , 1175-1186
An analysis of operating parameters in the cooling tower-based thermally activated building system
Thermally activated building system is not only energy efficient but also provides better thermal comfort compared to the conventional cooling systems. In this paper, COMSOL Multiphysics, a computational fluid dynamics tool, is used to simulate the performance of a cooling tower coupled with thermally activated building system for the hot and dry summer climatic conditions of New Delhi. The effects of three operating parameters, namely, temperature and inlet velocity of water and the number of cooling surfaces (area), on the performance of the system have been investigated. The results indicate that increasing the water inlet temperature from wet bulb temperature (WBT) to WBT + 6℃ would increase the operative temperature of the indoor space, a thermal comfort index, by 2℃. The increase in water inlet velocity from 0.2 to 1 m/s would decrease the diurnal average of operative temperature by 1.4℃. If only the roof was cooled, the diurnal average of operative temperature was 36.7℃. The diurnal average of operative temperature was reduced by 5.7℃ if all the building fabrics were cooled. In this case, with pipes connected in series from the floor first to walls and then to roof resulted in 2.9℃ lower operative temperature compared to that in the reverse sequence. Hence, the sequence in which the fabrics are cooled would have an appreciable influence on the performance of thermally activated building system.
- 27 September 2016
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 27 (2) , 219-232
A study of pipe parameters on the performance of cooling tower-based thermally activated building system
Passive cooling systems are energy efficient and eco-friendly alternatives to mechanical cooling systems. In this paper, the cooling tower-based thermally activated building system, which acts as an indirect evaporative cooling system, has been investigated using a computational fluid dynamics tool for the hot semi-arid climate of New Delhi. Three design parameters namely spacing, vertical position and arrangement of pipes embedded in the roof and floor were analysed for their influence on the cooling performance of the system. The results indicate that reducing pipe spacing from 0.3 to 0.1 m and moving the pipes closer to the inner surface from 0.135 to 0.015 m could reduce the operative temperatures by 1.6 and 2.7℃, respectively. For the same total water flow rate, a change in pipe arrangement from serpentine to parallel showed insignificant influence on the indoor comfort indices. The best combination of these three parameters can achieve an average operative temperature of 29℃, which is comfortable for the hot semi-arid climate of New Delhi where the adaptive neutral temperature was found to be 29.4℃. This study will contribute to heating, ventilating, air-conditioning designers’ understanding of the importance of these parameters for achieving the required comfort in buildings in India.
- 27 September 2016
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 27 (2) , 219-232
A study of pipe parameters on the performance of cooling tower-based thermally activated building system
Passive cooling systems are energy efficient and eco-friendly alternatives to mechanical cooling systems. In this paper, the cooling tower-based thermally activated building system, which acts as an indirect evaporative cooling system, has been investigated using a computational fluid dynamics tool for the hot semi-arid climate of New Delhi. Three design parameters namely spacing, vertical position and arrangement of pipes embedded in the roof and floor were analysed for their influence on the cooling performance of the system. The results indicate that reducing pipe spacing from 0.3 to 0.1 m and moving the pipes closer to the inner surface from 0.135 to 0.015 m could reduce the operative temperatures by 1.6 and 2.7℃, respectively. For the same total water flow rate, a change in pipe arrangement from serpentine to parallel showed insignificant influence on the indoor comfort indices. The best combination of these three parameters can achieve an average operative temperature of 29℃, which is comfortable for the hot semi-arid climate of New Delhi where the adaptive neutral temperature was found to be 29.4℃. This study will contribute to heating, ventilating, air-conditioning designers’ understanding of the importance of these parameters for achieving the required comfort in buildings in India.
- 2 March 2016
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 26 (5) , 680-693
Simulation of indoor comfort level in a building cooled by a cooling tower–concrete core cooling system under hot–semiarid climatic conditions
Concrete core cooling system is an energy efficient alternative to the conventional mechanical cooling system. It provides better comfort due to direct absorption of radiation load, low indoor air velocity, apt vertical temperature gradient and absence of noise. It can be operated at relatively higher water temperature, which facilitates the use of passive cooling strategies. In this study, a cooling tower, which is an ‘evaporative cooling system’, is preferred over other passive cooling options due to its better cooling performance in dry regions and its ability to operate all through the day. This paper presents the results of computational fluid dynamic analysis of a room cooled by concrete core cooling system supported by a cooling tower. The study reveals that for a typical hot–semiarid summer climatic condition in India, the system reduces the average indoor air temperature to a comfortable range of 23.5 to 28℃ from an uncomfortable range of 35.3 to 41℃ in a building without cooling. The average predicted percentage of dissatisfied falls from 99.7% in a building without cooling, to 37.3% if roof and floor of a building are cooled with concrete core cooling system and further to 6.3% if all surfaces are cooled with concrete core cooling system.
- 2 March 2016
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 26 (5) , 680-693
Simulation of indoor comfort level in a building cooled by a cooling tower–concrete core cooling system under hot–semiarid climatic conditions
Concrete core cooling system is an energy efficient alternative to the conventional mechanical cooling system. It provides better comfort due to direct absorption of radiation load, low indoor air velocity, apt vertical temperature gradient and absence of noise. It can be operated at relatively higher water temperature, which facilitates the use of passive cooling strategies. In this study, a cooling tower, which is an ‘evaporative cooling system’, is preferred over other passive cooling options due to its better cooling performance in dry regions and its ability to operate all through the day. This paper presents the results of computational fluid dynamic analysis of a room cooled by concrete core cooling system supported by a cooling tower. The study reveals that for a typical hot–semiarid summer climatic condition in India, the system reduces the average indoor air temperature to a comfortable range of 23.5 to 28℃ from an uncomfortable range of 35.3 to 41℃ in a building without cooling. The average predicted percentage of dissatisfied falls from 99.7% in a building without cooling, to 37.3% if roof and floor of a building are cooled with concrete core cooling system and further to 6.3% if all surfaces are cooled with concrete core cooling system.
- Open Access
- 1 May 2015
- Published by Yildiz Technical University in Journal of Thermal Engineering
- Vol. 1 (5) , 295
Monitoring and Simulation of Mechanically Ventilated Underground Car Parks
- 1 May 2015
- Published by Yildiz Technical University in Journal of Thermal Engineering
- Vol. 1 (5) , 295
Open AccessMonitoring and Simulation of Mechanically Ventilated Underground Car Parks
- 1 August 2013
- Published by Elsevier in Building and Environment
- Vol. 66, 54-64
Passive alternatives to mechanical air conditioning of building: A review
- 1 August 2013
- Published by Elsevier in Building and Environment
- Vol. 66, 54-64
Passive alternatives to mechanical air conditioning of building: A review