Soon-Ching Ng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Soon-Ching Ng has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Kaw-Sai Low
4 shared publications- Kaw-Sai Low
Faculty of Engineering & Science, Universiti Tunku Abdul Rahman, Selangor, Malaysia
2 shared publications Ngee-Heng Tioh
2 shared publications- Ngee-Heng Tioh
Faculty of Engineering & Science, Universiti Tunku Abdul Rahman, Selangor, Malaysia
2 shared publications Kaw Sai Low
Universiti Tunku Abdul Rahman
1 shared publicationNgee Heng Tioh
Universiti Tunku Abdul Rahman
1 shared publication
Latest Publications
- Open Access
- 1 January 2014
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 18 (1) , 220-225
Thermal conductivity of soil-based aerated lightweight concrete
- 1 January 2014
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 18 (1) , 220-225
Open AccessThermal conductivity of soil-based aerated lightweight concrete
- Open Access
- 1 July 2012
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 16 (5) , 809-815
Potential use of clayey soil in aerated lightweight concrete
- 1 July 2012
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 16 (5) , 809-815
Open AccessPotential use of clayey soil in aerated lightweight concrete
- 1 October 2011
- Published by Elsevier in Energy and Buildings
- Vol. 43 (10) , 2956-2960
Thermal inertia of newspaper sandwiched aerated lightweight concrete wall panels: Experimental study
- 1 October 2011
- Published by Elsevier in Energy and Buildings
- Vol. 43 (10) , 2956-2960
Thermal inertia of newspaper sandwiched aerated lightweight concrete wall panels: Experimental study
- 1 August 2011
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Construction Materials
- Vol. 164 (4) , 181-189
Thermal insulation performance of aerated lightweight concrete
Building envelopes that insulate buildings against heat and cold are receiving increasing attention as a promising passive energy-efficient measure in building construction. The experimental study reported here evaluates the thermal insulation performance of aerated lightweight concrete of different densities produced by incorporating either 100% sand or 100% soil as filler. Experimental aerated lightweight concrete wall panels (750 mm long, 750 mm wide and 40 mm thick) were cast and tested. Both soil-based and sand-based (control) aerated lightweight concrete panels were cured in a room with a prevailing temperature of approximately 29°C. The temperature gradient for soil-based aerated lightweight concrete panels was found to be superior to that of control aerated lightweight concrete panels of comparable density. The results indicate the potential improvement of soil-based aerated lightweight concrete in terms of thermal insulation compared with sand-based aerated lightweight concrete.
- 1 August 2011
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Construction Materials
- Vol. 164 (4) , 181-189
Thermal insulation performance of aerated lightweight concrete
Building envelopes that insulate buildings against heat and cold are receiving increasing attention as a promising passive energy-efficient measure in building construction. The experimental study reported here evaluates the thermal insulation performance of aerated lightweight concrete of different densities produced by incorporating either 100% sand or 100% soil as filler. Experimental aerated lightweight concrete wall panels (750 mm long, 750 mm wide and 40 mm thick) were cast and tested. Both soil-based and sand-based (control) aerated lightweight concrete panels were cured in a room with a prevailing temperature of approximately 29°C. The temperature gradient for soil-based aerated lightweight concrete panels was found to be superior to that of control aerated lightweight concrete panels of comparable density. The results indicate the potential improvement of soil-based aerated lightweight concrete in terms of thermal insulation compared with sand-based aerated lightweight concrete.
- 1 July 2011
- Published by Elsevier in Energy and Buildings
- Vol. 43 (7) , 1636-1645
Newspaper sandwiched aerated lightweight concrete wall panels—Thermal inertia, transient thermal behavior and surface temperature prediction
- 1 July 2011
- Published by Elsevier in Energy and Buildings
- Vol. 43 (7) , 1636-1645
Newspaper sandwiched aerated lightweight concrete wall panels—Thermal inertia, transient thermal behavior and surface temperature prediction
- 1 May 2011
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 261-263, 783-787
Thermal Insulation Property of Newspaper Membrane Encased Soil-Based Aerated Lightweight Concrete Panels
Roof and wall are known to be responsible for heat entering into a building and should therefore be thermally insulated in order to lessen energy consumption required for air-conditioning. In this study, four soil-based aerated lightweight concrete (ALC) panels each measures 750 mm (length) x 750 mm (breadth) x 70 mm (thick) with different aerial intensity of newspaper membrane encased were produced and tested on their thermal insulation property. For environmental friendly and economy reasons, clayey soil was used in place of sand to produce the ALC panels and they were tested in the Thermal Laboratory for twenty hours. Temperature gradient was computed based on the surface temperature measured during the test. The results obtained indicated that newspaper membrane encased soil-based ALC panels have superior heat insulation performance compared to control panel in terms of temperature gradient. It is found that the temperature gradient increased from 1.92 °C/cm to 2.08 °C/cm or 8.3% higher than control panel with just merely 0.05 g/cm2 of newspaper membrane encased.
- 1 May 2011
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 261-263, 783-787
Thermal Insulation Property of Newspaper Membrane Encased Soil-Based Aerated Lightweight Concrete Panels
Roof and wall are known to be responsible for heat entering into a building and should therefore be thermally insulated in order to lessen energy consumption required for air-conditioning. In this study, four soil-based aerated lightweight concrete (ALC) panels each measures 750 mm (length) x 750 mm (breadth) x 70 mm (thick) with different aerial intensity of newspaper membrane encased were produced and tested on their thermal insulation property. For environmental friendly and economy reasons, clayey soil was used in place of sand to produce the ALC panels and they were tested in the Thermal Laboratory for twenty hours. Temperature gradient was computed based on the surface temperature measured during the test. The results obtained indicated that newspaper membrane encased soil-based ALC panels have superior heat insulation performance compared to control panel in terms of temperature gradient. It is found that the temperature gradient increased from 1.92 °C/cm to 2.08 °C/cm or 8.3% higher than control panel with just merely 0.05 g/cm2 of newspaper membrane encased.
- 1 December 2010
- Published by Elsevier in Energy and Buildings
- Vol. 42 (12) , 2452-2456
Thermal conductivity of newspaper sandwiched aerated lightweight concrete panel
- 1 December 2010
- Published by Elsevier in Energy and Buildings
- Vol. 42 (12) , 2452-2456
Thermal conductivity of newspaper sandwiched aerated lightweight concrete panel