Tjerk P. Gutteling
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tjerk P. Gutteling has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
- Denis Schwartz
Lyon Neuroscience Research Center, CRNL, INSERM U1028, CNRS UMR5292, Lyon, France
5 shared publications Etienne Labyt
Mag4Health, Grenoble, France
4 shared publications- Julien Jung
Department of Functional Neurology and Epileptology Hospices Civils de Lyon (Lyon University Hospital), Hospital for Neurology and Neurosurgery Pierre Wertheimer Lyon France
4 shared publications Sébastien Daligault
CERMEP-Imagerie du Vivant, MEG Departement, Lyon, France
4 shared publications- W. Pieter Medendorp
Radboud University
4 shared publications J. Leon Kenemans
Department of Experimental Psychology, Helmholtz Institute, Utrecht University, 3584 CS, Utrecht, the Netherlands
3 shared publications
Latest Publications
- Open Access
- 2 December 2025
- Published by MIT Press in Imaging Neuroscience
- Vol. 3
Novel 4He-OPMs support waveform-specific beta burst analysis comparable to SQUID-MEG
Studying the electrophysiology of motor preparation and execution is challenging due to the restrictions often placed on the experimental paradigm by the imaging modality. MEG is well suited to track temporal brain dynamics while offering good spatial resolution, but requires an absence of head motion due to the fixed helmet and associated cryogenic cooling system. Here, we tested whether novel, room temperature, wearable optically pumped magnetometers using Helium can support waveform-specific beta burst analysis in a visuomotor task, compared directly with SQUID-MEG. Beta band activity (13–30 Hz) is widely associated with motor activity, and understood to occur in bursts rather than sustained oscillations. Here, we used a novel beta burst waveform extraction pipeline to quantify both burst occurrence over time and the modulation of specific burst waveform motifs. We find that particular waveform classes show robust task-relevant modulations of burst rate. Critically, burst waveform shapes and their waveform-specific rate modulations were highly similar for Helium-OPMs and SQUID-MEG data, despite modality differences in overall time-frequency characteristics. These results validate Helium-OPMs for waveform-specific beta burst analysis, and support their use for high-quality electrophysiology in less restricted paradigms.
- 2 December 2025
- Published by MIT Press in Imaging Neuroscience
- Vol. 3
Open AccessNovel 4He-OPMs support waveform-specific beta burst analysis comparable to SQUID-MEG
Studying the electrophysiology of motor preparation and execution is challenging due to the restrictions often placed on the experimental paradigm by the imaging modality. MEG is well suited to track temporal brain dynamics while offering good spatial resolution, but requires an absence of head motion due to the fixed helmet and associated cryogenic cooling system. Here, we tested whether novel, room temperature, wearable optically pumped magnetometers using Helium can support waveform-specific beta burst analysis in a visuomotor task, compared directly with SQUID-MEG. Beta band activity (13–30 Hz) is widely associated with motor activity, and understood to occur in bursts rather than sustained oscillations. Here, we used a novel beta burst waveform extraction pipeline to quantify both burst occurrence over time and the modulation of specific burst waveform motifs. We find that particular waveform classes show robust task-relevant modulations of burst rate. Critically, burst waveform shapes and their waveform-specific rate modulations were highly similar for Helium-OPMs and SQUID-MEG data, despite modality differences in overall time-frequency characteristics. These results validate Helium-OPMs for waveform-specific beta burst analysis, and support their use for high-quality electrophysiology in less restricted paradigms.
- Open Access
- 27 September 2025
- Published by Wiley in Human Brain Mapping
- Vol. 46 (14) , e70368
The Mismatch Negativity Compared: EEG, SQUID‐MEG, and Novel 4Helium‐OPMs
Magneto‐encephalography (MEG) provides a higher spatial resolution than electro‐encephalography (EEG) to measure human auditory responses. However, conventional cryogenic MEG systems (SQUID‐MEG) suffer from severe technological restrictions limiting, for instance, routine clinical use. Fortunately, a new generation of MEG sensors, optically pumped magnetometers (OPMs), has been developed to bridge the gap, combining the wearability of EEG with the benefits of MEG signal acquisition. We aim to assess their potential for studying auditory mismatch processing. The auditory mismatch negativity (MMN) is a well‐characterized evoked component observable using a passive oddball paradigm with two‐tone sound sequences. It has been extensively described using both EEG and MEG and is part of many EEG‐based clinical applications, such as the assessment of patients with disorders of consciousness. MMN is therefore a relevant candidate to evaluate OPM performance. We use recently developed Helium‐OPMs, which are high dynamic range MEG sensors that operate at room temperature. We compare their performance with cryogenic SQUID‐MEG and EEG in a passive frequency oddball paradigm. Results show a significant MMN across subjects in all modalities as well as a high temporal similarity between modalities. Signal‐to‐noise ratios were also similar, and detection of significant individual MMN (within‐subjects) using the OPM system was equal to or better than EEG. Given that the OPM system tested here is a prototype comprised of only five sensors, these results are a promising step towards wearable MEG that combines the advantages of MEG and EEG.
- 27 September 2025
- Published by Wiley in Human Brain Mapping
- Vol. 46 (14) , e70368
Open AccessThe Mismatch Negativity Compared: EEG, SQUID‐MEG, and Novel 4Helium‐OPMs
Magneto‐encephalography (MEG) provides a higher spatial resolution than electro‐encephalography (EEG) to measure human auditory responses. However, conventional cryogenic MEG systems (SQUID‐MEG) suffer from severe technological restrictions limiting, for instance, routine clinical use. Fortunately, a new generation of MEG sensors, optically pumped magnetometers (OPMs), has been developed to bridge the gap, combining the wearability of EEG with the benefits of MEG signal acquisition. We aim to assess their potential for studying auditory mismatch processing. The auditory mismatch negativity (MMN) is a well‐characterized evoked component observable using a passive oddball paradigm with two‐tone sound sequences. It has been extensively described using both EEG and MEG and is part of many EEG‐based clinical applications, such as the assessment of patients with disorders of consciousness. MMN is therefore a relevant candidate to evaluate OPM performance. We use recently developed Helium‐OPMs, which are high dynamic range MEG sensors that operate at room temperature. We compare their performance with cryogenic SQUID‐MEG and EEG in a passive frequency oddball paradigm. Results show a significant MMN across subjects in all modalities as well as a high temporal similarity between modalities. Signal‐to‐noise ratios were also similar, and detection of significant individual MMN (within‐subjects) using the OPM system was equal to or better than EEG. Given that the OPM system tested here is a prototype comprised of only five sensors, these results are a promising step towards wearable MEG that combines the advantages of MEG and EEG.
- Open Access
Beta burst waveform extraction using novel 4 He-OPMs
Studying the electrophysiology of motor preparation and execution is challenging due to the restrictions often placed on the experimental paradigm by the imaging modality. MEG is well suited to track temporal brain dynamics while offering good spatial resolution, but requires an absence of head motion due to the fixed helmet and associated cryogenic cooling system. Here we used novel, room temperature, wearable optically pumped magnetometers using Helium to measure the MEG in a motor preparation and execution task and compare this with ‘classic’ SQUID-MEG. Beta band activity (13-30Hz) is widely associated with motor activity, and it has become widely accepted that beta activity occurs in bursts rather than sustained activity. Here we used a novel beta burst extraction pipeline to look at not only the occurrence of the beta bursts across the timecourse of motor preparation and execution, but at the specific waveforms of the beta burst that evolve over time. Results show that specific beta burst waveforms show strong task relevant modulations of burst rate. Beta burst waveforms extracted using Helium-OPMs were very similar to those extracted using SQUID-MEG, with comparable modulations of burst rate over time for specific waveforms. This shows a promising step to obtaining high quality electrophysiological data in less restricted paradigms.
Open AccessBeta burst waveform extraction using novel 4 He-OPMs
Studying the electrophysiology of motor preparation and execution is challenging due to the restrictions often placed on the experimental paradigm by the imaging modality. MEG is well suited to track temporal brain dynamics while offering good spatial resolution, but requires an absence of head motion due to the fixed helmet and associated cryogenic cooling system. Here we used novel, room temperature, wearable optically pumped magnetometers using Helium to measure the MEG in a motor preparation and execution task and compare this with ‘classic’ SQUID-MEG. Beta band activity (13-30Hz) is widely associated with motor activity, and it has become widely accepted that beta activity occurs in bursts rather than sustained activity. Here we used a novel beta burst extraction pipeline to look at not only the occurrence of the beta bursts across the timecourse of motor preparation and execution, but at the specific waveforms of the beta burst that evolve over time. Results show that specific beta burst waveforms show strong task relevant modulations of burst rate. Beta burst waveforms extracted using Helium-OPMs were very similar to those extracted using SQUID-MEG, with comparable modulations of burst rate over time for specific waveforms. This shows a promising step to obtaining high quality electrophysiological data in less restricted paradigms.
- Open Access
Unleashing the Potential of 4 He OPM-MEG: A Comparison with SQUID-MEG for Detecting Interictal Epileptic Activity
Summary: Objectives: Conventional magnetoencephalography (MEG) based on superconducting quantum interference devices sensors (SQUIDs), are the only widely used MEG systems in both clinical and research settings. However, they have limitations that hinder their widespread deployment. Optically pumped magnetometers (OPMs) offer several advantages over SQUIDs, particularly for epilepsy studies: lightweight and flexible, OPMs can be integrated into adaptable motion-tolerant headsets, enabling recordings during seizures or natural head movements, and potentially enhancing the detection of interictal epileptiform discharges (IEDs). In the present study, we assess the capabilities of a 5-sensors MEG system with helium OPMs ( 4 He-OPMs) in detecting IEDs. Methods: First, we compare the performance of SQUID-MEG and 4 He-OPM-MEG in a routine clinical setup with a group of 7 patients. Second, we perform combined intra-cerebral (SEEG) 4 He-OPM-MEG and SQUID-MEG recordings in a single patient to demonstrate the ability of both systems to detect IEDs originating from deep brain structures. Results: The key finding is that, even with a very limited number of sensors, the 4 He-OPM-MEG prototype successfully captured interictal epileptic activity in most patients. This activity was clearly detectable and exhibited the characteristic morphology with strikingly similar time courses between 4 He-OPM-MEG and SQUID-MEG signals. Using combined SEEG and OPM-MEG recordings, we obtained the first direct validation of the ability of 4 He OPM sensors to record epileptic activities originating from deep structures. Significance: These results strongly support the clinical adoption of a lightweight, high-sensitivity, whole-head 4 He OPMs-MEG system, offering new perspectives for epilepsy diagnostics and beyond, and enabling the democratization and spread of MEG in clinical and research settings. Plain language summary: Magnetoencephalography is a non-invasive neuroimaging technique that has been shown to improve surgical outcomes in epileptic patients. However, its use remains limited due to several constraints, which could be overcome by a new generation of sensors: the optically pumped magnetometers (OPMs). Here, we validate the ability of OPM sensors to record epileptic brain activity in a regular clinical setup and thanks to simultaneous intracerebral recordings. These sensors open new venues for the widespread application of magnetoencephalography in the management of epilepsy and other neurological diseases, as well as for fundamental neuroscience. Key points: Epileptic abnormalities are detected by 4 He OPMs as well as with classical magnetoencephalography. Hippocampal interictal activity can be detected by 4 He OPMs as shown by simultaeous SEEG-OPM recordings. This results represents significant step towards the validation of OPM-MEG for epilepsy diagnosis and neuroscience research.
Open AccessUnleashing the Potential of 4 He OPM-MEG: A Comparison with SQUID-MEG for Detecting Interictal Epileptic Activity
Summary: Objectives: Conventional magnetoencephalography (MEG) based on superconducting quantum interference devices sensors (SQUIDs), are the only widely used MEG systems in both clinical and research settings. However, they have limitations that hinder their widespread deployment. Optically pumped magnetometers (OPMs) offer several advantages over SQUIDs, particularly for epilepsy studies: lightweight and flexible, OPMs can be integrated into adaptable motion-tolerant headsets, enabling recordings during seizures or natural head movements, and potentially enhancing the detection of interictal epileptiform discharges (IEDs). In the present study, we assess the capabilities of a 5-sensors MEG system with helium OPMs ( 4 He-OPMs) in detecting IEDs. Methods: First, we compare the performance of SQUID-MEG and 4 He-OPM-MEG in a routine clinical setup with a group of 7 patients. Second, we perform combined intra-cerebral (SEEG) 4 He-OPM-MEG and SQUID-MEG recordings in a single patient to demonstrate the ability of both systems to detect IEDs originating from deep brain structures. Results: The key finding is that, even with a very limited number of sensors, the 4 He-OPM-MEG prototype successfully captured interictal epileptic activity in most patients. This activity was clearly detectable and exhibited the characteristic morphology with strikingly similar time courses between 4 He-OPM-MEG and SQUID-MEG signals. Using combined SEEG and OPM-MEG recordings, we obtained the first direct validation of the ability of 4 He OPM sensors to record epileptic activities originating from deep structures. Significance: These results strongly support the clinical adoption of a lightweight, high-sensitivity, whole-head 4 He OPMs-MEG system, offering new perspectives for epilepsy diagnostics and beyond, and enabling the democratization and spread of MEG in clinical and research settings. Plain language summary: Magnetoencephalography is a non-invasive neuroimaging technique that has been shown to improve surgical outcomes in epileptic patients. However, its use remains limited due to several constraints, which could be overcome by a new generation of sensors: the optically pumped magnetometers (OPMs). Here, we validate the ability of OPM sensors to record epileptic brain activity in a regular clinical setup and thanks to simultaneous intracerebral recordings. These sensors open new venues for the widespread application of magnetoencephalography in the management of epilepsy and other neurological diseases, as well as for fundamental neuroscience. Key points: Epileptic abnormalities are detected by 4 He OPMs as well as with classical magnetoencephalography. Hippocampal interictal activity can be detected by 4 He OPMs as shown by simultaeous SEEG-OPM recordings. This results represents significant step towards the validation of OPM-MEG for epilepsy diagnosis and neuroscience research.
- Open Access
The Mismatch Negativity compared: EEG, SQUID-MEG and novel 4 Helium-OPMs
Magneto-encephalography (MEG) provides a higher spatial resolution than electro-encephalography (EEG) to measure human auditory responses. However, conventional cryogenic MEG systems (SQUID-MEG) suffer from severe technological restrictions limiting, for instance, routine clinical use. Fortunately, a new generation of MEG sensors, optically pumped magnetometers (OPMs), have been developed to bridge the gap, combining the wearability of EEG with the benefits of MEG signal acquisition. We aim to assess their potential for studying auditory mismatch processing. The auditory Mismatch Negativity (MMN) is a well-characterized evoked component observable using a passive oddball paradigm with two-tone sound sequences. It has been extensively described using both EEG and MEG and is part of many EEG-based clinical applications, such as the assessment of patients with disorders of consciousness. MMN is therefore a relevant candidate to evaluate OPM performance. We use recently developed Helium-OPMs, which are high dynamic range MEG sensors that operate at room temperature. We compare their performance with cryogenic SQUID-MEG and EEG in a passive frequency oddball paradigm. Results show a significant MMN across subjects in all modalities as well as a high temporal similarity between modalities. Signal-to-noise ratios were also similar, and detection of significant individual MMN (within-subjects) using the OPM system was equal or better than EEG. Given that the OPM system tested here is a prototype comprised of only five sensors, these results are a promising step towards wearable MEG that combines the advantages of MEG and EEG.
Open AccessThe Mismatch Negativity compared: EEG, SQUID-MEG and novel 4 Helium-OPMs
Magneto-encephalography (MEG) provides a higher spatial resolution than electro-encephalography (EEG) to measure human auditory responses. However, conventional cryogenic MEG systems (SQUID-MEG) suffer from severe technological restrictions limiting, for instance, routine clinical use. Fortunately, a new generation of MEG sensors, optically pumped magnetometers (OPMs), have been developed to bridge the gap, combining the wearability of EEG with the benefits of MEG signal acquisition. We aim to assess their potential for studying auditory mismatch processing. The auditory Mismatch Negativity (MMN) is a well-characterized evoked component observable using a passive oddball paradigm with two-tone sound sequences. It has been extensively described using both EEG and MEG and is part of many EEG-based clinical applications, such as the assessment of patients with disorders of consciousness. MMN is therefore a relevant candidate to evaluate OPM performance. We use recently developed Helium-OPMs, which are high dynamic range MEG sensors that operate at room temperature. We compare their performance with cryogenic SQUID-MEG and EEG in a passive frequency oddball paradigm. Results show a significant MMN across subjects in all modalities as well as a high temporal similarity between modalities. Signal-to-noise ratios were also similar, and detection of significant individual MMN (within-subjects) using the OPM system was equal or better than EEG. Given that the OPM system tested here is a prototype comprised of only five sensors, these results are a promising step towards wearable MEG that combines the advantages of MEG and EEG.
- Open Access
A New Generation of OPM for High Dynamic and Large Bandwidth MEG: The 4He OPMs—First Applications in Healthy Volunteers
MagnetoEncephaloGraphy (MEG) provides a measure of electrical activity in the brain at a millisecond time scale. From these signals, one can non-invasively derive the dynamics of brain activity. Conventional MEG systems (SQUID-MEG) use very low temperatures to achieve the necessary sensitivity. This leads to severe experimental and economical limitations. A new generation of MEG sensors is emerging: the optically pumped magnetometers (OPM). In OPM, an atomic gas enclosed in a glass cell is traversed by a laser beam whose modulation depends on the local magnetic field. MAG4Health is developing OPMs using Helium gas (4He-OPM). They operate at room temperature with a large dynamic range and a large frequency bandwidth and output natively a 3D vectorial measure of the magnetic field. In this study, five 4He-OPMs were compared to a classical SQUID-MEG system in a group of 18 volunteers to evaluate their experimental performances. Considering that the 4He-OPMs operate at real room temperature and can be placed directly on the head, our assumption was that 4He-OPMs would provide a reliable recording of physiological magnetic brain activity. Indeed, the results showed that the 4He-OPMs showed very similar results to the classical SQUID-MEG system by taking advantage of a shorter distance to the brain, despite having a lower sensitivity.
Open AccessA New Generation of OPM for High Dynamic and Large Bandwidth MEG: The 4He OPMs—First Applications in Healthy Volunteers
MagnetoEncephaloGraphy (MEG) provides a measure of electrical activity in the brain at a millisecond time scale. From these signals, one can non-invasively derive the dynamics of brain activity. Conventional MEG systems (SQUID-MEG) use very low temperatures to achieve the necessary sensitivity. This leads to severe experimental and economical limitations. A new generation of MEG sensors is emerging: the optically pumped magnetometers (OPM). In OPM, an atomic gas enclosed in a glass cell is traversed by a laser beam whose modulation depends on the local magnetic field. MAG4Health is developing OPMs using Helium gas (4He-OPM). They operate at room temperature with a large dynamic range and a large frequency bandwidth and output natively a 3D vectorial measure of the magnetic field. In this study, five 4He-OPMs were compared to a classical SQUID-MEG system in a group of 18 volunteers to evaluate their experimental performances. Considering that the 4He-OPMs operate at real room temperature and can be placed directly on the head, our assumption was that 4He-OPMs would provide a reliable recording of physiological magnetic brain activity. Indeed, the results showed that the 4He-OPMs showed very similar results to the classical SQUID-MEG system by taking advantage of a shorter distance to the brain, despite having a lower sensitivity.
- Open Access
- 6 May 2022
- Published by Elsevier in Progress in Neurobiology
- Vol. 214, 102285
Alpha oscillations reflect suppression of distractors with increased perceptual load
- 6 May 2022
- Published by Elsevier in Progress in Neurobiology
- Vol. 214, 102285
Open AccessAlpha oscillations reflect suppression of distractors with increased perceptual load
- Open Access
- 6 July 2021
- Published by Society for Neuroscience in The Journal of Neuroscience
- Vol. 41 (31) , 6684-6698
No Evidence for Entrainment: Endogenous Gamma Oscillations and Rhythmic Flicker Responses Coexist in Visual Cortex
Over the past decades, numerous studies have linked cortical gamma oscillations (∼30–100 Hz) to neurocomputational mechanisms. Their functional relevance, however, is still passionately debated. Here, we asked whether endogenous gamma oscillations in the human brain can be entrained by a rhythmic photic drive >50 Hz. Such a noninvasive modulation of endogenous brain rhythms would allow conclusions about their causal involvement in neurocognition. To this end, we systematically investigated oscillatory responses to a rapid sinusoidal flicker in the absence and presence of endogenous gamma oscillations using magnetoencephalography (MEG) in combination with a high-frequency projector. The photic drive produced a robust response over visual cortex to stimulation frequencies of up to 80 Hz. Strong, endogenous gamma oscillations were induced using moving grating stimuli as repeatedly done in previous research. When superimposing the flicker and the gratings, there was no evidence for phase or frequency entrainment of the endogenous gamma oscillations by the photic drive. Unexpectedly, we did not observe an amplification of the flicker response around participants9 individual gamma frequencies (IGFs); rather, the magnitude of the response decreased monotonically with increasing frequency. Source reconstruction suggests that the flicker response and the gamma oscillations were produced by separate, coexistent generators in visual cortex. The presented findings challenge the notion that cortical gamma oscillations can be entrained by rhythmic visual stimulation. Instead, the mechanism generating endogenous gamma oscillations seems to be resilient to external perturbation. SIGNIFICANCE STATEMENT We aimed to investigate to what extent ongoing, high-frequency oscillations in the gamma-band (30–100 Hz) in the human brain can be entrained by a visual flicker. Gamma oscillations have long been suggested to coordinate neuronal firing and enable interregional communication. Our results demonstrate that rhythmic visual stimulation cannot hijack the dynamics of ongoing gamma oscillations; rather, the flicker response and the endogenous gamma oscillations coexist in different visual areas. Therefore, while a visual flicker evokes a strong neuronal response even at high frequencies in the gamma-band, it does not entrain endogenous gamma oscillations in visual cortex. This has important implications for interpreting studies investigating the causal and neuroprotective effects of rhythmic sensory stimulation in the gamma-band.
- 6 July 2021
- Published by Society for Neuroscience in The Journal of Neuroscience
- Vol. 41 (31) , 6684-6698
Open AccessNo Evidence for Entrainment: Endogenous Gamma Oscillations and Rhythmic Flicker Responses Coexist in Visual Cortex
Over the past decades, numerous studies have linked cortical gamma oscillations (∼30–100 Hz) to neurocomputational mechanisms. Their functional relevance, however, is still passionately debated. Here, we asked whether endogenous gamma oscillations in the human brain can be entrained by a rhythmic photic drive >50 Hz. Such a noninvasive modulation of endogenous brain rhythms would allow conclusions about their causal involvement in neurocognition. To this end, we systematically investigated oscillatory responses to a rapid sinusoidal flicker in the absence and presence of endogenous gamma oscillations using magnetoencephalography (MEG) in combination with a high-frequency projector. The photic drive produced a robust response over visual cortex to stimulation frequencies of up to 80 Hz. Strong, endogenous gamma oscillations were induced using moving grating stimuli as repeatedly done in previous research. When superimposing the flicker and the gratings, there was no evidence for phase or frequency entrainment of the endogenous gamma oscillations by the photic drive. Unexpectedly, we did not observe an amplification of the flicker response around participants9 individual gamma frequencies (IGFs); rather, the magnitude of the response decreased monotonically with increasing frequency. Source reconstruction suggests that the flicker response and the gamma oscillations were produced by separate, coexistent generators in visual cortex. The presented findings challenge the notion that cortical gamma oscillations can be entrained by rhythmic visual stimulation. Instead, the mechanism generating endogenous gamma oscillations seems to be resilient to external perturbation. SIGNIFICANCE STATEMENT We aimed to investigate to what extent ongoing, high-frequency oscillations in the gamma-band (30–100 Hz) in the human brain can be entrained by a visual flicker. Gamma oscillations have long been suggested to coordinate neuronal firing and enable interregional communication. Our results demonstrate that rhythmic visual stimulation cannot hijack the dynamics of ongoing gamma oscillations; rather, the flicker response and the endogenous gamma oscillations coexist in different visual areas. Therefore, while a visual flicker evokes a strong neuronal response even at high frequencies in the gamma-band, it does not entrain endogenous gamma oscillations in visual cortex. This has important implications for interpreting studies investigating the causal and neuroprotective effects of rhythmic sensory stimulation in the gamma-band.
- Open Access
Alpha oscillations reflect suppression of distractors with increased perceptual load
Summary: Attention serves an essential role in cognition and behaviour allowing us to focus on behaviourally-relevant objects while ignoring distraction. Perceptual load theory states that attentional resources are allocated according to the requirements of the task, i.e. its ‘load’. The theory predicts that the resources left to process irrelevant, possibly distracting stimuli, are reduced when the perceptual load is high. However, it remains unclear how this allocation of attentional resources specifically relates to neural excitability and suppression mechanisms. In this magnetoencephalography (MEG) study, we show that brain oscillations in the alpha band (8-13Hz) implement the suppression of distracting objects when the perceptual load is high. In parallel, high load increased neuronal excitability for target objects, as reflected by rapid frequency tagging. We suggest that the allocation of resources in tasks with high perceptual load is implemented by a gain increase for targets, complemented by distractor suppression reflected by alpha band oscillations closing the ‘gate’ for interference.
Open AccessAlpha oscillations reflect suppression of distractors with increased perceptual load
Summary: Attention serves an essential role in cognition and behaviour allowing us to focus on behaviourally-relevant objects while ignoring distraction. Perceptual load theory states that attentional resources are allocated according to the requirements of the task, i.e. its ‘load’. The theory predicts that the resources left to process irrelevant, possibly distracting stimuli, are reduced when the perceptual load is high. However, it remains unclear how this allocation of attentional resources specifically relates to neural excitability and suppression mechanisms. In this magnetoencephalography (MEG) study, we show that brain oscillations in the alpha band (8-13Hz) implement the suppression of distracting objects when the perceptual load is high. In parallel, high load increased neuronal excitability for target objects, as reflected by rapid frequency tagging. We suggest that the allocation of resources in tasks with high perceptual load is implemented by a gain increase for targets, complemented by distractor suppression reflected by alpha band oscillations closing the ‘gate’ for interference.
- Open Access
No evidence for entrainment: endogenous gamma oscillations and rhythmic flicker responses coexist in visual cortex
Over the past decades, a plethora of studies have linked cortical gamma oscillations ( ∼ 30-100 Hz) to neuro-computational mechanisms. Their functional relevance, however, is still passionately debated. Here, we asked if endogenous gamma oscillations in the human brain can be entrained by a rhythmic photic drive > 50 Hz. A noninvasive modulation of endogenous brain rhythms allows conclusions about their causal involvement in neurocognition. To this end, we systematically investigated oscillatory responses to a rapid sinusoidal flicker in the absence and presence of endogenous gamma oscillations using magnetoencephalography (MEG) in combination with a high-frequency projector. The photic drive produced a robust response over visual cortex to stimulation frequencies of up to 80 Hz. Strong, endogenous gamma oscillations were induced using moving grating stimuli as repeatedly done in previous research. When superimposing the flicker and the gratings, there was no evidence for phase or frequency entrainment of the endogenous gamma oscillations by the photic drive. Unexpectedly, we did not observe an amplification of the flicker response around participants’ individual gamma frequencies; rather, the magnitude of the response decreased monotonically with increasing frequency. Source reconstruction suggests that the flicker response and the gamma oscillations were produced by separate, coexistent generators in visual cortex. The presented findings challenge the notion that cortical gamma oscillations can be entrained by rhythmic visual stimulation. Instead, the mechanism generating endogenous gamma oscillations seems to be resilient to external perturbation. Significance Statement: We aimed to investigate to what extent ongoing, high-frequency oscillations in the gamma band (30-100 Hz) in the human brain can be entrained by a visual flicker. Gamma oscillations have long been suggested to coordinate neuronal firing and enable inter-regional communication. Our results demonstrate that rhythmic visual stimulation cannot hijack the dynamics of ongoing gamma oscillations; rather, the flicker response and the endogenous gamma oscillations coexist in different visual areas. Therefore, while a visual flicker evokes a strong neuronal response even at high frequencies in the gamma-band, it does not entrain endogenous gamma oscillations in visual cortex. This has important implications for interpreting studies investigating the causal and neuroprotective effects of rhythmic sensory stimulation in the gamma band.
Open AccessNo evidence for entrainment: endogenous gamma oscillations and rhythmic flicker responses coexist in visual cortex
Over the past decades, a plethora of studies have linked cortical gamma oscillations ( ∼ 30-100 Hz) to neuro-computational mechanisms. Their functional relevance, however, is still passionately debated. Here, we asked if endogenous gamma oscillations in the human brain can be entrained by a rhythmic photic drive > 50 Hz. A noninvasive modulation of endogenous brain rhythms allows conclusions about their causal involvement in neurocognition. To this end, we systematically investigated oscillatory responses to a rapid sinusoidal flicker in the absence and presence of endogenous gamma oscillations using magnetoencephalography (MEG) in combination with a high-frequency projector. The photic drive produced a robust response over visual cortex to stimulation frequencies of up to 80 Hz. Strong, endogenous gamma oscillations were induced using moving grating stimuli as repeatedly done in previous research. When superimposing the flicker and the gratings, there was no evidence for phase or frequency entrainment of the endogenous gamma oscillations by the photic drive. Unexpectedly, we did not observe an amplification of the flicker response around participants’ individual gamma frequencies; rather, the magnitude of the response decreased monotonically with increasing frequency. Source reconstruction suggests that the flicker response and the gamma oscillations were produced by separate, coexistent generators in visual cortex. The presented findings challenge the notion that cortical gamma oscillations can be entrained by rhythmic visual stimulation. Instead, the mechanism generating endogenous gamma oscillations seems to be resilient to external perturbation. Significance Statement: We aimed to investigate to what extent ongoing, high-frequency oscillations in the gamma band (30-100 Hz) in the human brain can be entrained by a visual flicker. Gamma oscillations have long been suggested to coordinate neuronal firing and enable inter-regional communication. Our results demonstrate that rhythmic visual stimulation cannot hijack the dynamics of ongoing gamma oscillations; rather, the flicker response and the endogenous gamma oscillations coexist in different visual areas. Therefore, while a visual flicker evokes a strong neuronal response even at high frequencies in the gamma-band, it does not entrain endogenous gamma oscillations in visual cortex. This has important implications for interpreting studies investigating the causal and neuroprotective effects of rhythmic sensory stimulation in the gamma band.