M. S. Raghu Prasad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
M. S. Raghu Prasad has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Manivannan Muniyandi
Indian Institute of Technology Madras
7 shared publications Govindan Manoharan
Department of Surgical Gastroenterology, Government Stanley Medical College and Hospital, Chennai, Tamil Nadu, India
2 shared publications- Sunny Purswani
Indian Institute of Technology, Madras
2 shared publications S. M. Chandramohan
Rajiv Gandhi Government General Hospital and Madras Medical College
1 shared publicationS.M. Chandramohan
Institute of Surgical Gastroenterology, Madras Medical College and Rajiv Gandhi Government General Hospital, Chennai, Tamil Nadu, India
1 shared publicationServarayan. M. Chandramohan
Institute of Surgical Gastroenterology, Madras Medical College and Rajiv Gandhi Government General Hospital, Chennai, Tamil Nadu, India
1 shared publication
Latest Publications
- 29 May 2018
- Published by SAGE Publications in Surgical Innovation
- Vol. 25 (5) , 499-514
Face and Construct Validity of a Novel Virtual Reality–Based Bimanual Laparoscopic Force-Skills Trainer With Haptics Feedback
Background. The purpose of this study was to examine the face and construct validity of a custom-developed bimanual laparoscopic force-skills trainer with haptics feedback. The study also examined the effect of handedness on fundamental and complex tasks. Methods. Residents (n = 25) and surgeons (n = 25) performed virtual reality–based bimanual fundamental and complex tasks. Tool-tissue reaction forces were summed, recorded, and analysed. Seven different force-based measures and a 1-time measure were used as metrics. Subsequently, participants filled out face validity and demographic questionnaires. Results. Residents and surgeons were positive on the design, workspace, and usefulness of the simulator. Construct validity results showed significant differences between residents and experts during the execution of fundamental and complex tasks. In both tasks, residents applied large forces with higher coefficient of variation and force jerks (P < .001). Experts, with their dominant hand, applied lower forces in complex tasks and higher forces in fundamental tasks (P < .001). The coefficients of force variation (CoV) of residents and experts were higher in complex tasks (P < .001). Strong correlations were observed between CoV and task time for fundamental (r = 0.70) and complex tasks (r = 0.85). Range of smoothness of force was higher for the non-dominant hand in both fundamental and complex tasks. Conclusions. The simulator was able to differentiate the force-skills of residents and surgeons, and objectively evaluate the effects of handedness on laparoscopic force-skills. Competency-based laparoscopic skills assessment curriculum should be updated to meet the requirements of bimanual force-based training.
- 29 May 2018
- Published by SAGE Publications in Surgical Innovation
- Vol. 25 (5) , 499-514
Face and Construct Validity of a Novel Virtual Reality–Based Bimanual Laparoscopic Force-Skills Trainer With Haptics Feedback
Background. The purpose of this study was to examine the face and construct validity of a custom-developed bimanual laparoscopic force-skills trainer with haptics feedback. The study also examined the effect of handedness on fundamental and complex tasks. Methods. Residents (n = 25) and surgeons (n = 25) performed virtual reality–based bimanual fundamental and complex tasks. Tool-tissue reaction forces were summed, recorded, and analysed. Seven different force-based measures and a 1-time measure were used as metrics. Subsequently, participants filled out face validity and demographic questionnaires. Results. Residents and surgeons were positive on the design, workspace, and usefulness of the simulator. Construct validity results showed significant differences between residents and experts during the execution of fundamental and complex tasks. In both tasks, residents applied large forces with higher coefficient of variation and force jerks (P < .001). Experts, with their dominant hand, applied lower forces in complex tasks and higher forces in fundamental tasks (P < .001). The coefficients of force variation (CoV) of residents and experts were higher in complex tasks (P < .001). Strong correlations were observed between CoV and task time for fundamental (r = 0.70) and complex tasks (r = 0.85). Range of smoothness of force was higher for the non-dominant hand in both fundamental and complex tasks. Conclusions. The simulator was able to differentiate the force-skills of residents and surgeons, and objectively evaluate the effects of handedness on laparoscopic force-skills. Competency-based laparoscopic skills assessment curriculum should be updated to meet the requirements of bimanual force-based training.
- Open Access
- 10 April 2017
- Published by ASME International
Design and Analysis of a Novel 5-DoF Bimanual Laparoscopic Impedance Skills Trainer With Haptics Feedback
Laparoscopic surgery has widely replaced open surgery due to the advantages it has for patients both during surgery and post-surgery recovery. Due to inversion and remote access to the surgical site, haptics feedback is altered with laparoscopic surgical instruments [1]. This leads to excessive exertion of force [2]. Many intra operative errors like tissue injury in laparoscopic surgery are due to texertion of large forces [2]. Over the years, virtual reality (VR) based laparoscopic surgical simulators with haptics feedback have been instrumental in teaching basic and advanced laparoscopic skills to residents and surgeons [3]. However, a major limitation in modern day VR based simulator training systems is that they do not effectively teach the bimanual impedance-based laparoscopic skills. Past studies on VR based laparoscopic training have captured the skills sets of residents and surgeons using force and psychomotor metrics [3, 4]. However, till date none have explored the effects of experience on impedance based training. In this study, we analyze the impedance skills of residents and surgeons using custom developed novel bimanual laparoscopic skills trainer.
- 10 April 2017
- Published by ASME International
Open AccessDesign and Analysis of a Novel 5-DoF Bimanual Laparoscopic Impedance Skills Trainer With Haptics Feedback
Laparoscopic surgery has widely replaced open surgery due to the advantages it has for patients both during surgery and post-surgery recovery. Due to inversion and remote access to the surgical site, haptics feedback is altered with laparoscopic surgical instruments [1]. This leads to excessive exertion of force [2]. Many intra operative errors like tissue injury in laparoscopic surgery are due to texertion of large forces [2]. Over the years, virtual reality (VR) based laparoscopic surgical simulators with haptics feedback have been instrumental in teaching basic and advanced laparoscopic skills to residents and surgeons [3]. However, a major limitation in modern day VR based simulator training systems is that they do not effectively teach the bimanual impedance-based laparoscopic skills. Past studies on VR based laparoscopic training have captured the skills sets of residents and surgeons using force and psychomotor metrics [3, 4]. However, till date none have explored the effects of experience on impedance based training. In this study, we analyze the impedance skills of residents and surgeons using custom developed novel bimanual laparoscopic skills trainer.
- 1 September 2016
- Published by Elsevier in Journal of Surgical Education
- Vol. 73 (5) , 858-869
Objective Assessment of Laparoscopic Force and Psychomotor Skills in a Novel Virtual Reality-Based Haptic Simulator
- 1 September 2016
- Published by Elsevier in Journal of Surgical Education
- Vol. 73 (5) , 858-869
Objective Assessment of Laparoscopic Force and Psychomotor Skills in a Novel Virtual Reality-Based Haptic Simulator
- 16 October 2014
- Published by Springer Nature in Surgical Endoscopy
- Vol. 29 (7) , 1927-1943
Effects of laparoscopic instrument and finger on force perception: a first step towards laparoscopic force-skills training
In laparoscopic surgery, no external feedback on the magnitude of the force exerted is available. Hence, surgeons and residents tend to exert excessive force, which leads to tissue trauma. Ability of surgeons and residents to perceive their own force output without external feedback is a critical factor in laparoscopic force-skills training. Additionally, existing methods of laparoscopic training do not effectively train residents and novices on force-skills. Hence, there is growing need for the development of force-based training curriculum. As a first step towards force-based laparoscopic skills training, this study analysed force perception difference between laparoscopic instrument and finger in contralateral bimanual passive probing task. The study compared the isometric force matching performance of novices, residents and surgeons with finger and laparoscopic instrument. Contralateral force matching paradigm was employed to analyse the force perception capability in terms of relative (accuracy), and constant errors in force matching. Force perception of experts was found to be better than novices and residents. Interestingly, laparoscopic instrument was more accurate in discriminating the forces than finger. The dominant hand attempted to match the forces accurately, whereas non-dominant hand (NH) overestimated the forces. Further, the NH of experts was found to be most accurate. Furthermore, excessive forces were applied at lower force levels and at very high force levels. Due to misperception of force, novices and residents applied excessive forces. However, experts had good control over force with both dominant and NHs. These findings suggest that force-based training curricula should not only have proprioception tasks, but should also include bimanual force-skills training exercises in order to improve force perception ability and hand skills of novices and residents. The results can be used as a performance metric in both box and virtual reality based force-skills training.
- 16 October 2014
- Published by Springer Nature in Surgical Endoscopy
- Vol. 29 (7) , 1927-1943
Effects of laparoscopic instrument and finger on force perception: a first step towards laparoscopic force-skills training
In laparoscopic surgery, no external feedback on the magnitude of the force exerted is available. Hence, surgeons and residents tend to exert excessive force, which leads to tissue trauma. Ability of surgeons and residents to perceive their own force output without external feedback is a critical factor in laparoscopic force-skills training. Additionally, existing methods of laparoscopic training do not effectively train residents and novices on force-skills. Hence, there is growing need for the development of force-based training curriculum. As a first step towards force-based laparoscopic skills training, this study analysed force perception difference between laparoscopic instrument and finger in contralateral bimanual passive probing task. The study compared the isometric force matching performance of novices, residents and surgeons with finger and laparoscopic instrument. Contralateral force matching paradigm was employed to analyse the force perception capability in terms of relative (accuracy), and constant errors in force matching. Force perception of experts was found to be better than novices and residents. Interestingly, laparoscopic instrument was more accurate in discriminating the forces than finger. The dominant hand attempted to match the forces accurately, whereas non-dominant hand (NH) overestimated the forces. Further, the NH of experts was found to be most accurate. Furthermore, excessive forces were applied at lower force levels and at very high force levels. Due to misperception of force, novices and residents applied excessive forces. However, experts had good control over force with both dominant and NHs. These findings suggest that force-based training curricula should not only have proprioception tasks, but should also include bimanual force-skills training exercises in order to improve force perception ability and hand skills of novices and residents. The results can be used as a performance metric in both box and virtual reality based force-skills training.
- 1 September 2014
- Published by SAGE Publications in Proceedings of the Human Factors and Ergonomics Society Annual Meeting
- Vol. 58 (1) , 683-687
Comparison of Force Matching Performance in Conventional and Laparoscopic Force-Based Task
Laparoscopic instruments have limited haptics feedback. Hence, novices tend to exert excessive force which leads to tissue trauma. In laparoscopic surgery, no external information is available on the magnitude of excessive force. Therefore, novices should be trained to accurately perceive their own force output. This study analyzed the force perception of 18 novices in the absence of external information, by comparing the isometric force matching performance of index finger (i.e. used in conventional procedures) in extended arm posture with that of laparoscopic instrument in a force-based probing task. The study also examined the effect of handedness on force perception. A contra-lateral force matching paradigm was employed to analyze the matching performance of the novice subjects. Interestingly, matching error was found to be lower for laparoscopic instrument. An effect of handedness was visible for laparoscopic instrument only. The dominant hand overestimated the forces of non-dominant hand. The results can be used as a performance metric to evaluate the force perception of novices in laparoscopic force skills-training tasks.
- 1 September 2014
- Published by SAGE Publications in Proceedings of the Human Factors and Ergonomics Society Annual Meeting
- Vol. 58 (1) , 683-687
Comparison of Force Matching Performance in Conventional and Laparoscopic Force-Based Task
Laparoscopic instruments have limited haptics feedback. Hence, novices tend to exert excessive force which leads to tissue trauma. In laparoscopic surgery, no external information is available on the magnitude of excessive force. Therefore, novices should be trained to accurately perceive their own force output. This study analyzed the force perception of 18 novices in the absence of external information, by comparing the isometric force matching performance of index finger (i.e. used in conventional procedures) in extended arm posture with that of laparoscopic instrument in a force-based probing task. The study also examined the effect of handedness on force perception. A contra-lateral force matching paradigm was employed to analyze the matching performance of the novice subjects. Interestingly, matching error was found to be lower for laparoscopic instrument. An effect of handedness was visible for laparoscopic instrument only. The dominant hand overestimated the forces of non-dominant hand. The results can be used as a performance metric to evaluate the force perception of novices in laparoscopic force skills-training tasks.
- 12 January 2013
- Published by Springer Nature
- p. 377-386
Modeling of Human Hand Force Based Tasks Using Fitts’s Law
- 12 January 2013
- Published by Springer Nature
- p. 377-386
Modeling of Human Hand Force Based Tasks Using Fitts’s Law
- 12 January 2013
- Published by Springer Nature
- p. 365-375
Force JND for Right Index Finger Using Contra Lateral Force Matching Paradigm
- 12 January 2013
- Published by Springer Nature
- p. 365-375
Force JND for Right Index Finger Using Contra Lateral Force Matching Paradigm