Paul Xolin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Paul Xolin has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Marc Engels-Deutsch
Université de Lorraine
2 shared publications - Tarak Ben Zineb
LPMM UMR CNRS 7554 ENSAM CER de Metz, Technopole Metz 2000, 4 rue Augustin Fresnel, 57078 Metz Cedex, France
2 shared publications A-M Gevrey
Université de Lorraine
1 shared publicationF Thiebaud
Université de Lorraine
1 shared publication- Frédéric Thiebaud
CNRS, Arts et Métiers ParisTech, Université de Lorraine, Nancy, France
1 shared publication M Vincent
Université de Lorraine
1 shared publication
Latest Publications
- 3 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Contribution au développement d'une nouvelle génération de limes endodontiques en alliage à mémoire de forme monocristallin cuivreux
Les dernières avancées réalisées dans le domaine de l’instrumentation canalaire ont permis de rendre le traitement endodontique plus rapide et plus efficace. L’amélioration des limes endodontiques au travers des géométries instrumentales, mouvement de travail ou propriétés mécaniques du matériau constitutif de l’instrument ont rendu le traitement plus sûr dans la préservation de l’organe dentaire et des tissus parodontaux environnants. Néanmoins, peu de recherches se sont portées sur l’utilisation d’Alliage à Mémoire de Forme (AMF) différents du Nickel-Titane (Ni-Ti). Ce travail se propose d’étudier une potentielle utilisation en endodontie d’un nouvel AMF doté de propriétés antimicrobiennes très prometteuses : le Cuivre-Aluminium-Béryllium (Cu-Al-Be) monocristallin. Cette étude se fait au travers d’une approche expérimentale, au moyen d’un dispositif d’essais innovant, capable d’appliquer des chargements combinés ou séparés de flexion et de torsion. Ces chargements sont les principales sollicitations appliquées aux limes endodontiques lors du traitement canalaire. Une approche numérique vient compléter les études expérimentales, avec un modèle éléments-finis représentatif des chargements appliqués par le dispositif d’essais. Un programme de génération de modèles géométriques de limes endodontiques est développé et permet de représenter les réponses obtenues expérimentalement à l’aide de deux lois de comportement thermomécaniques adaptées aux AMF polycristallins et monocristallins. Enfin, à l’aide de ces deux outils, un plan d’expérience capable de déterminer l’influence des paramètres géométriques d’une lime endodontique sur sa réponse mécanique est réalisé et apporte une aide précieuse à la décision pour le choix d’une géométrie et d’une utilisation adaptée pour ces limes endodontiques en Cu-Al-Be monocristallin.
- 3 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Contribution au développement d'une nouvelle génération de limes endodontiques en alliage à mémoire de forme monocristallin cuivreux
Les dernières avancées réalisées dans le domaine de l’instrumentation canalaire ont permis de rendre le traitement endodontique plus rapide et plus efficace. L’amélioration des limes endodontiques au travers des géométries instrumentales, mouvement de travail ou propriétés mécaniques du matériau constitutif de l’instrument ont rendu le traitement plus sûr dans la préservation de l’organe dentaire et des tissus parodontaux environnants. Néanmoins, peu de recherches se sont portées sur l’utilisation d’Alliage à Mémoire de Forme (AMF) différents du Nickel-Titane (Ni-Ti). Ce travail se propose d’étudier une potentielle utilisation en endodontie d’un nouvel AMF doté de propriétés antimicrobiennes très prometteuses : le Cuivre-Aluminium-Béryllium (Cu-Al-Be) monocristallin. Cette étude se fait au travers d’une approche expérimentale, au moyen d’un dispositif d’essais innovant, capable d’appliquer des chargements combinés ou séparés de flexion et de torsion. Ces chargements sont les principales sollicitations appliquées aux limes endodontiques lors du traitement canalaire. Une approche numérique vient compléter les études expérimentales, avec un modèle éléments-finis représentatif des chargements appliqués par le dispositif d’essais. Un programme de génération de modèles géométriques de limes endodontiques est développé et permet de représenter les réponses obtenues expérimentalement à l’aide de deux lois de comportement thermomécaniques adaptées aux AMF polycristallins et monocristallins. Enfin, à l’aide de ces deux outils, un plan d’expérience capable de déterminer l’influence des paramètres géométriques d’une lime endodontique sur sa réponse mécanique est réalisé et apporte une aide précieuse à la décision pour le choix d’une géométrie et d’une utilisation adaptée pour ces limes endodontiques en Cu-Al-Be monocristallin.
- 26 June 2020
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 31 (15) , 1763-1781
Combined bending–torsion testing device for characterization of shape memory alloy endodontic files
Design has an important influence on mechanical response of endodontic instruments made of shape memory alloys. The experimental and numerical prediction of their thermomechanical response is necessary to improve their behavior during operating inside root canal. Due to the curved and tapered shape of the dental canal, endodontic files are subjected to rotating bending during the root canal preparation phase. These rotative bending could ever be combined with torsion when the instruments are engined in the root canal. Bending and torsion tests available in the standard ISO 3630-1 do not take into account this combined loading leading to a response different from the one obtained by superposition of separated bending and torsion loadings. This article details the design and the realization of bending–torsion testing device particularly adapted to shape memory alloy endodontic files. It allows to control the torsion and the bending rotations in a separate or a combined way. Qualification tests using this bending–torsion testing device on NiTi wires showed a good agreement between the experimental and the simulated responses. Finally, this bending–torsion testing device allowed to analyze the response of various NiTi endodontic files, currently used in endodontics, subjected to bending, torsion, and combined bending–torsion loadings. Obtained results showed clearly that combined bending–torsion loading changes significantly the shape memory alloy file response.
- 26 June 2020
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 31 (15) , 1763-1781
Combined bending–torsion testing device for characterization of shape memory alloy endodontic files
Design has an important influence on mechanical response of endodontic instruments made of shape memory alloys. The experimental and numerical prediction of their thermomechanical response is necessary to improve their behavior during operating inside root canal. Due to the curved and tapered shape of the dental canal, endodontic files are subjected to rotating bending during the root canal preparation phase. These rotative bending could ever be combined with torsion when the instruments are engined in the root canal. Bending and torsion tests available in the standard ISO 3630-1 do not take into account this combined loading leading to a response different from the one obtained by superposition of separated bending and torsion loadings. This article details the design and the realization of bending–torsion testing device particularly adapted to shape memory alloy endodontic files. It allows to control the torsion and the bending rotations in a separate or a combined way. Qualification tests using this bending–torsion testing device on NiTi wires showed a good agreement between the experimental and the simulated responses. Finally, this bending–torsion testing device allowed to analyze the response of various NiTi endodontic files, currently used in endodontics, subjected to bending, torsion, and combined bending–torsion loadings. Obtained results showed clearly that combined bending–torsion loading changes significantly the shape memory alloy file response.
- 7 March 2017
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 26 (4) , 045014
Experimental and numerical analysis of penetration/removal response of endodontic instrument made of single crystal Cu-based SMA: comparison with NiTi SMA instruments
This paper presents an experimental and numerical study showing that single crystal shape memory alloy (SMA) Cu-based endodontic instruments can lead to equivalent mechanical performances compared to NiTi-based instruments besides their interesting biological properties. Following a previous finite element analysis (FEA) of single crystal CuAlBe endodontic instruments (Vincent et al 2015 J. Mater. Eng. Perform . 24 4128–39), prototypes with the determined geometrical parameters were machined and experimentally characterized in continuous rotation during a penetration/removal (P/R) protocol in artificial canals. The obtained mechanical responses were compared to responses of NiTi endodontic files in the same conditions. In addition, FEA was conducted and compared with the experimental results to validate the adopted modeling and to evaluate the local quantities inside the instrument as the stress state and the distribution of volume fraction of martensite. The obtained results highlight that single crystal CuAlBe SMA prototypes show equivalent mechanical responses to its NiTi homologous prototypes in the same P/R experimental conditions.
- 7 March 2017
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 26 (4) , 045014
Experimental and numerical analysis of penetration/removal response of endodontic instrument made of single crystal Cu-based SMA: comparison with NiTi SMA instruments
This paper presents an experimental and numerical study showing that single crystal shape memory alloy (SMA) Cu-based endodontic instruments can lead to equivalent mechanical performances compared to NiTi-based instruments besides their interesting biological properties. Following a previous finite element analysis (FEA) of single crystal CuAlBe endodontic instruments (Vincent et al 2015 J. Mater. Eng. Perform . 24 4128–39), prototypes with the determined geometrical parameters were machined and experimentally characterized in continuous rotation during a penetration/removal (P/R) protocol in artificial canals. The obtained mechanical responses were compared to responses of NiTi endodontic files in the same conditions. In addition, FEA was conducted and compared with the experimental results to validate the adopted modeling and to evaluate the local quantities inside the instrument as the stress state and the distribution of volume fraction of martensite. The obtained results highlight that single crystal CuAlBe SMA prototypes show equivalent mechanical responses to its NiTi homologous prototypes in the same P/R experimental conditions.