Ana Cravo Sá
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ana Cravo Sá has a total of 83 co-authors. Here are the top co-authors by number of shared publications:
Andreia Barateiro
Radiotherapy Department, Portuguese Institute of Oncology Francisco Gentil, Lisbon, Portugal
4 shared publicationsPedro Almeida
Instituto de Biofísica e Engenharia Biomédica, Faculdade de Ciências, Universidade de Lisboa, Lisbon, Portugal
4 shared publicationsTiago Madaleno
Radiotherapy Department, Portuguese Institute of Oncology Francisco Gentil, Lisbon, Portugal
4 shared publicationsBryan P. Bednarz
Department of Medical Physics, Wisconsin Institutes for Medical Research, University of Wisconsin Hospital and Clinics, Madison, WI, United States
3 shared publicationsPedro Vaz
Radiation Protection and Safety Group, Centro de Ciências e Tecnologias Nucleares (C2TN), Bobadela, Portugal
3 shared publicationsCarina Marques Coelho
Área Científica de Radioterapia, Escola Superior de Tecnologia da Saúde de Lisboa - Instituto Politécnico de Lisboa, Avenida D. João II, lote 4.69.01, 1990-096 Lisboa, Portugal
2 shared publications
Latest Publications
- Open Access
- 7 October 2026
- Published by Elsevier in Radiography
- Vol. 32 (7)
Doses in planning computed tomography in one radiotherapy department: Description of exposure parameters and estimation of organ doses, effective doses and typical doses
- 7 October 2026
- Published by Elsevier in Radiography
- Vol. 32 (7)
Open AccessDoses in planning computed tomography in one radiotherapy department: Description of exposure parameters and estimation of organ doses, effective doses and typical doses
- 18 August 2026
- Published by Elsevier in Radiography
- Vol. 32 (6) , 103537
Comparison of Gonadal Dose Estimation Using Treatment Planning Systems and Monte Carlo Methods in Pelvic Radiotherapy
- 18 August 2026
- Published by Elsevier in Radiography
- Vol. 32 (6) , 103537
Comparison of Gonadal Dose Estimation Using Treatment Planning Systems and Monte Carlo Methods in Pelvic Radiotherapy
- 20 July 2026
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 57 (5)
Assessment of the risk of developing second tumors after pediatric craniospinal irradiation
- 20 July 2026
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 57 (5)
Assessment of the risk of developing second tumors after pediatric craniospinal irradiation
- Open Access
- 21 June 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (13) , 7000
Gonad Dose Assessment of Patients Undergoing Pelvic Radiotherapy
Introduction: Radiotherapy can impact on patients’ reproductive organs and fertility. This study aims (i) to assess whether the doses to the gonads of 70 patients met the tolerance doses used in radiotherapy planning; (ii) to compare Three-Dimensional Conformal Radiotherapy (3DCRT) with Volumetric Modulated Arc Therapy (VMAT) techniques; and (iii) to verify if ovarian transposition reduces the dose to the ovaries. Methods: A retrospective analysis of 70 patients aged 45 or under who underwent pelvic radiotherapy between 2014 and 2023 in a radiotherapy department was carried out. The dose constraints considered were derived from the Dose-Volume Constraints for Organs at Risk in Radiotherapy project. Results: The average number of children of all the patients in the study was 1.25 and the standard deviation was 1.40. No statistically significant differences were detected regarding the doses to the left and right gonads between 3DCRT and VMAT (p > 0.05). There were statistically significant differences between female patients who underwent ovarian transposition and those who did not undergo ovarian transposition regarding the maximum and medium doses in both right and left ovaries (p < 0.05), with a dose reduction that could reduce doses by an average of up to 39 Gy. Conclusions: In the total sample, 58.6% of patients were treated with VMAT, only 18.6% met the maximum dose limits, and 22.9% met the average dose constraints. Only five women underwent ovarian transposition, which proved effective in meeting dose constraints and significantly reducing the dose to the ovaries.
- 21 June 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (13) , 7000
Open AccessGonad Dose Assessment of Patients Undergoing Pelvic Radiotherapy
Introduction: Radiotherapy can impact on patients’ reproductive organs and fertility. This study aims (i) to assess whether the doses to the gonads of 70 patients met the tolerance doses used in radiotherapy planning; (ii) to compare Three-Dimensional Conformal Radiotherapy (3DCRT) with Volumetric Modulated Arc Therapy (VMAT) techniques; and (iii) to verify if ovarian transposition reduces the dose to the ovaries. Methods: A retrospective analysis of 70 patients aged 45 or under who underwent pelvic radiotherapy between 2014 and 2023 in a radiotherapy department was carried out. The dose constraints considered were derived from the Dose-Volume Constraints for Organs at Risk in Radiotherapy project. Results: The average number of children of all the patients in the study was 1.25 and the standard deviation was 1.40. No statistically significant differences were detected regarding the doses to the left and right gonads between 3DCRT and VMAT (p > 0.05). There were statistically significant differences between female patients who underwent ovarian transposition and those who did not undergo ovarian transposition regarding the maximum and medium doses in both right and left ovaries (p < 0.05), with a dose reduction that could reduce doses by an average of up to 39 Gy. Conclusions: In the total sample, 58.6% of patients were treated with VMAT, only 18.6% met the maximum dose limits, and 22.9% met the average dose constraints. Only five women underwent ovarian transposition, which proved effective in meeting dose constraints and significantly reducing the dose to the ovaries.
- 21 February 2025
- Published by Elsevier in Physica Medica
- Vol. 131, 104937
Cone beam CT (CBCT) in radiotherapy: Assessment of doses using a pragmatic setup in an international setting
- 21 February 2025
- Published by Elsevier in Physica Medica
- Vol. 131, 104937
Cone beam CT (CBCT) in radiotherapy: Assessment of doses using a pragmatic setup in an international setting
- Open Access
- 1 August 2024
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 14, 1449082
Corrigendum: Comparison of 3DCRT and IMRT out-of-field doses in pediatric patients using Monte Carlo simulations with treatment planning system calculations and measurements
[This corrects the article DOI: 10.3389/fonc.2022.879167.].
- 1 August 2024
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 14, 1449082
Open AccessCorrigendum: Comparison of 3DCRT and IMRT out-of-field doses in pediatric patients using Monte Carlo simulations with treatment planning system calculations and measurements
[This corrects the article DOI: 10.3389/fonc.2022.879167.].
- Open Access
- 9 October 2023
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 13, 1293922
Corrigendum: Comparison of 3DCRT and IMRT out-of-field doses in pediatric patients using Monte Carlo simulations with treatment planning system calculations and measurements
Corrigendum: Comparison of 3DCRT and IMRT out-of-field doses in pediatric patients using Monte Carlo simulations with treatment planning system calculations and measurements
- 9 October 2023
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 13, 1293922
Open AccessCorrigendum: Comparison of 3DCRT and IMRT out-of-field doses in pediatric patients using Monte Carlo simulations with treatment planning system calculations and measurements
Corrigendum: Comparison of 3DCRT and IMRT out-of-field doses in pediatric patients using Monte Carlo simulations with treatment planning system calculations and measurements
- Open Access
- 5 August 2022
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 12, 879167
Comparison of 3DCRT and IMRT out-of-field doses in pediatric patients using Monte Carlo simulations with treatment planning system calculations and measurements
3DCRT and IMRT out-of-field doses in pediatric patients were compared using Monte Carlo simulations with treatment planning system calculations and measurements.Purpose: Out-of-field doses are given to healthy tissues, which may allow the development of second tumors. The use of IMRT in pediatric patients has been discussed, as it leads to a “bath” of low doses to large volumes of out-of-field organs and tissues. This study aims to compare out-of-field doses in pediatric patients comparing IMRT and 3DCRT techniques using measurements, Monte Carlo (MC) simulations, and treatment planning system (TPS) calculations.Materials and methods: A total dose of 54 Gy was prescribed to a PTV in the brain of a pediatric anthropomorphic phantom, for both techniques. To assess the out-of-field organ doses for both techniques, two treatment plans were performed with the 3DCRT and IMRT techniques in TPS. Measurements were carried out in a LINAC using a pediatric anthropomorphic phantom and thermoluminescent dosimeters to recreate the treatment plans, previously performed in the TPS. A computational model of a LINAC, the associated multileaf collimators, and a voxelized pediatric phantom implemented in the Monte Carlo N-Particle 6.1 computer program were also used to perform MC simulations of the out-of-field organ doses, for both techniques.Results: The results obtained by measurements and MC simulations indicate a significant increase in dose using the IMRT technique when compared to the 3DCRT technique. More specifically, measurements show higher doses with IMRT, namely, in right eye (13,041 vs. 593 mGy), left eye (6,525 vs. 475 mGy), thyroid (79 vs. 70 mGy), right lung (37 vs. 28 mGy), left lung (27 vs. 20 mGy), and heart (31 vs. 25 mGy). The obtained results indicate that out-of-field doses can be seriously underestimated by TPS.Discussion: This study presents, for the first time, out-of-field dose measurements in a realistic scenario and calculations for IMRT, centered on a voxelized pediatric phantom and an MC model of a medical LINAC, including MLC with log file-based simulations. The results pinpoint significant discrepancies in out-of-field doses for the two techniques and are a cause of concern because TPS calculations cannot accurately predict such doses. The obtained doses may presumably increase the risk of development of second tumors.
- 5 August 2022
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 12, 879167
Open AccessComparison of 3DCRT and IMRT out-of-field doses in pediatric patients using Monte Carlo simulations with treatment planning system calculations and measurements
3DCRT and IMRT out-of-field doses in pediatric patients were compared using Monte Carlo simulations with treatment planning system calculations and measurements.Purpose: Out-of-field doses are given to healthy tissues, which may allow the development of second tumors. The use of IMRT in pediatric patients has been discussed, as it leads to a “bath” of low doses to large volumes of out-of-field organs and tissues. This study aims to compare out-of-field doses in pediatric patients comparing IMRT and 3DCRT techniques using measurements, Monte Carlo (MC) simulations, and treatment planning system (TPS) calculations.Materials and methods: A total dose of 54 Gy was prescribed to a PTV in the brain of a pediatric anthropomorphic phantom, for both techniques. To assess the out-of-field organ doses for both techniques, two treatment plans were performed with the 3DCRT and IMRT techniques in TPS. Measurements were carried out in a LINAC using a pediatric anthropomorphic phantom and thermoluminescent dosimeters to recreate the treatment plans, previously performed in the TPS. A computational model of a LINAC, the associated multileaf collimators, and a voxelized pediatric phantom implemented in the Monte Carlo N-Particle 6.1 computer program were also used to perform MC simulations of the out-of-field organ doses, for both techniques.Results: The results obtained by measurements and MC simulations indicate a significant increase in dose using the IMRT technique when compared to the 3DCRT technique. More specifically, measurements show higher doses with IMRT, namely, in right eye (13,041 vs. 593 mGy), left eye (6,525 vs. 475 mGy), thyroid (79 vs. 70 mGy), right lung (37 vs. 28 mGy), left lung (27 vs. 20 mGy), and heart (31 vs. 25 mGy). The obtained results indicate that out-of-field doses can be seriously underestimated by TPS.Discussion: This study presents, for the first time, out-of-field dose measurements in a realistic scenario and calculations for IMRT, centered on a voxelized pediatric phantom and an MC model of a medical LINAC, including MLC with log file-based simulations. The results pinpoint significant discrepancies in out-of-field doses for the two techniques and are a cause of concern because TPS calculations cannot accurately predict such doses. The obtained doses may presumably increase the risk of development of second tumors.
- 1 March 2020
- Published by Elsevier in Physica Medica
- Vol. 71, 53-61
Assessment of out-of-field doses in radiotherapy treatments of paediatric patients using Monte Carlo methods and measurements
- 1 March 2020
- Published by Elsevier in Physica Medica
- Vol. 71, 53-61
Assessment of out-of-field doses in radiotherapy treatments of paediatric patients using Monte Carlo methods and measurements