Elena V. Daboss
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Elena V. Daboss has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Arkady A. Karyakin
Chemistry Faculty of M.V. Lomonosov Moscow State University, 119991, Moscow, Russia
8 shared publications - Maria A. Komkova
Chemistry Department, M.V. Lomonosov Moscow State University, Leninskie Gory, 1/3, Moscow 119991, Russia
3 shared publications Arkady A. Karyakin
2 shared publications- Christine Kranz
Institute of Analytical and Bioanalytical Chemistry Ulm University Ulm Germany
2 shared publications - Darya V. Vokhmyanina
Chemistry Faculty of M.V. Lomonosov, Moscow State University, 119991 Moscow, Russia
2 shared publications Dmitrii V. Tikhonov
2 shared publications
Latest Publications
- Open Access
- 21 August 2026
- Published by American Chemical Society (ACS) in ACS Electrochemistry
- Vol. 2 (9) , 2160-2172
Probing Hot-Carrier and Thermal Contributions to Plasmon-Assisted Electrochemistry at Gold Nanorods
Plasmon-assisted electrochemistry has emerged as a powerful strategy to enhance interfacial charge transfer by exploiting localized surface plasmon resonance (LSPR) in metallic nanostructures. Under resonant illumination, gold nanorods (AuNRs) generate energetic hot electron–hole pair and localized heating, both of which may influence electron transfer kinetics. However, decoupling both contributions remains challenging. Here, we present a plasmonic transducer system based on AuNRs anchored to mercaptopropyl triethoxysilane-modified indium tin oxide electrodes (AuNRs/MPTES-ITO) and investigate the photoelectrochemical behavior under low-intensity near-infrared (780 nm) LED illumination. Using chronoamperometry, in situ fiber-optic thermometry to measure the electrode-bulk surrounding temperature, and COMSOL simulations, we show that faradaic current enhancement does not follow the gradual temperature increase but instead reaches a rapid steady state, indicating hot-electron-driven effects. The heterogeneous electron-transfer rate constant determined via scanning electrochemical microscopy (SECM) approach curves reveals a 45 ± 4% (n = 9) increase under illumination for non-capped-AuNRs/MPTES-ITO, while MPTES-ITO shows only a 15 ± 2% (n = 9) enhancement. SECM mapping further visualizes localized faradaic current amplification on AuNR-rich regions. Together, these results suggest that even at low power densities (307.7 mW·cm–2), longitudinal LSPR excitation in AuNRs efficiently generates hot carriers capable of enhancing electrochemical reactions with a nondominant thermal contribution. This study provides a spatially resolved approach to investigate hot-carrier and photothermal pathways in plasmon-assisted electrochemistry.
- 21 August 2026
- Published by American Chemical Society (ACS) in ACS Electrochemistry
- Vol. 2 (9) , 2160-2172
Open AccessProbing Hot-Carrier and Thermal Contributions to Plasmon-Assisted Electrochemistry at Gold Nanorods
Plasmon-assisted electrochemistry has emerged as a powerful strategy to enhance interfacial charge transfer by exploiting localized surface plasmon resonance (LSPR) in metallic nanostructures. Under resonant illumination, gold nanorods (AuNRs) generate energetic hot electron–hole pair and localized heating, both of which may influence electron transfer kinetics. However, decoupling both contributions remains challenging. Here, we present a plasmonic transducer system based on AuNRs anchored to mercaptopropyl triethoxysilane-modified indium tin oxide electrodes (AuNRs/MPTES-ITO) and investigate the photoelectrochemical behavior under low-intensity near-infrared (780 nm) LED illumination. Using chronoamperometry, in situ fiber-optic thermometry to measure the electrode-bulk surrounding temperature, and COMSOL simulations, we show that faradaic current enhancement does not follow the gradual temperature increase but instead reaches a rapid steady state, indicating hot-electron-driven effects. The heterogeneous electron-transfer rate constant determined via scanning electrochemical microscopy (SECM) approach curves reveals a 45 ± 4% (n = 9) increase under illumination for non-capped-AuNRs/MPTES-ITO, while MPTES-ITO shows only a 15 ± 2% (n = 9) enhancement. SECM mapping further visualizes localized faradaic current amplification on AuNR-rich regions. Together, these results suggest that even at low power densities (307.7 mW·cm–2), longitudinal LSPR excitation in AuNRs efficiently generates hot carriers capable of enhancing electrochemical reactions with a nondominant thermal contribution. This study provides a spatially resolved approach to investigate hot-carrier and photothermal pathways in plasmon-assisted electrochemistry.
- Open Access
- 9 June 2026
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 418 (23) , 7981-7991
Prussian Blue–based microsensors in short-circuit mode: a simplified approach for localized hydrogen peroxide detection
We report on a Prussian Blue (PB)–based microsensor with an integrated silver quasi-reference electrode (QRE) for selective hydrogen peroxide (H2O2) reduction using the excellent electrocatalytic properties of PB in a so-called short-circuit mode. This “single-electrode” configuration eliminates the need for a potentiostat allowing a simplified read-out. The microsensors are either based on PB or on PB-nickel hexacyanoferrate (PB-NiHCF) and demonstrate high sensitivity (1.8 A M−1 cm−2 and 0.32 A M−1 cm−2 for PB-based and PB-NiHCF-based microsensors, respectively), operational stability (maintaining performance for 4 h under harsh conditions in 1 mM H2O2), and selectivity toward H2O2 with negligible interference from common reductants such as ascorbic acid and catecholamines. By incorporating a platinum-black (Pt-B) sublayer, the PB film deposition could be significantly improved, yielding a threefold sensitivity increase and a 14-fold enhancement in operational stability. The microsensors were successfully applied as probes for scanning electrochemical microscopy (SECM) measurements to map H2O2 evolution. Furthermore, by modification of the PB-modified Pt microelectrode (ME) with glucose oxidase (GOx) and hexokinase (HEX), an adenosine triphosphate (ATP) microbiosensor was developed and applied for extracellular ATP release detection. The ATP determination relies on the competitive GOx- and HEX-catalyzed reactions for glucose. These results highlight the potential of PB-based MEs in short-circuit mode for localized electrochemical studies of not only catalytic systems where monitoring H2O2 concentration is of primary interest, but also various biological systems, such as living cells, where H2O2 is generated as a byproduct of enzymatic reactions. Graphical abstract The alternative text for this image may have been generated using AI.
- 9 June 2026
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 418 (23) , 7981-7991
Open AccessPrussian Blue–based microsensors in short-circuit mode: a simplified approach for localized hydrogen peroxide detection
We report on a Prussian Blue (PB)–based microsensor with an integrated silver quasi-reference electrode (QRE) for selective hydrogen peroxide (H2O2) reduction using the excellent electrocatalytic properties of PB in a so-called short-circuit mode. This “single-electrode” configuration eliminates the need for a potentiostat allowing a simplified read-out. The microsensors are either based on PB or on PB-nickel hexacyanoferrate (PB-NiHCF) and demonstrate high sensitivity (1.8 A M−1 cm−2 and 0.32 A M−1 cm−2 for PB-based and PB-NiHCF-based microsensors, respectively), operational stability (maintaining performance for 4 h under harsh conditions in 1 mM H2O2), and selectivity toward H2O2 with negligible interference from common reductants such as ascorbic acid and catecholamines. By incorporating a platinum-black (Pt-B) sublayer, the PB film deposition could be significantly improved, yielding a threefold sensitivity increase and a 14-fold enhancement in operational stability. The microsensors were successfully applied as probes for scanning electrochemical microscopy (SECM) measurements to map H2O2 evolution. Furthermore, by modification of the PB-modified Pt microelectrode (ME) with glucose oxidase (GOx) and hexokinase (HEX), an adenosine triphosphate (ATP) microbiosensor was developed and applied for extracellular ATP release detection. The ATP determination relies on the competitive GOx- and HEX-catalyzed reactions for glucose. These results highlight the potential of PB-based MEs in short-circuit mode for localized electrochemical studies of not only catalytic systems where monitoring H2O2 concentration is of primary interest, but also various biological systems, such as living cells, where H2O2 is generated as a byproduct of enzymatic reactions. Graphical abstract The alternative text for this image may have been generated using AI.
- Open Access
- 8 October 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (10) , 486
Noninvasive Monitoring of Glycemia Level in Diabetic Patients by Wearable Advanced Biosensors
We report on the possibility of noninvasive diabetes monitoring through continuous analysis of sweat. The prediction of the blood glucose level in diabetic patients is possible on the basis of their sweat glucose content due to the positive correlation discovered. The ratio between the blood glucose and sweat glucose concentrations for a certain diabetic subject is stable within weeks, excluding requirements for frequent blood probing. The glucose variations in sweat display allometric (non-linear) dependence on those in blood, allowing more precise blood glucose estimation. Selective (avoiding false-positive responses) and sensitive (sweat glucose is on average 30–50 times lower) detection is possible with biosensors based on the glucose oxidase enzyme coupled with a Prussian Blue transducer. Reliable glucose detection in just secreted sweat would allow noninvasive monitoring of the glycemia level in diabetic patients.
- 8 October 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (10) , 486
Open AccessNoninvasive Monitoring of Glycemia Level in Diabetic Patients by Wearable Advanced Biosensors
We report on the possibility of noninvasive diabetes monitoring through continuous analysis of sweat. The prediction of the blood glucose level in diabetic patients is possible on the basis of their sweat glucose content due to the positive correlation discovered. The ratio between the blood glucose and sweat glucose concentrations for a certain diabetic subject is stable within weeks, excluding requirements for frequent blood probing. The glucose variations in sweat display allometric (non-linear) dependence on those in blood, allowing more precise blood glucose estimation. Selective (avoiding false-positive responses) and sensitive (sweat glucose is on average 30–50 times lower) detection is possible with biosensors based on the glucose oxidase enzyme coupled with a Prussian Blue transducer. Reliable glucose detection in just secreted sweat would allow noninvasive monitoring of the glycemia level in diabetic patients.
- Open Access
- 8 May 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 35 (1) , 2
Novel Electrochemical Lactate Biosensors Based on Prussian Blue Nanoparticles
We report on the novel electrochemical lactate biosensors based on Prussian blue nanoparticles. The immobilization of lactate oxidase was performed through drop-casting on the sensor surface of a mixture containing enzyme, (3-aminopropyl)triethoxysilane and isopropyl alcohol. The apparent Michaelis constant and inactivation constant were determined (0.29 ± 0.03 mM and 0.042 ± 0.002 min−1, respectively) and compared with values obtained for biosensors based on Prussian blue films. The developed lactate biosensors are not inferior in characteristics to those previously known, while the manufacturing process is less laborious. Obtained values also indicate that lactate biosensors based on Prussian blue nanoparticles and lactate oxidase have sufficient sensitivity and operational stability for analytical application in medical and biological research.
- 8 May 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 35 (1) , 2
Open AccessNovel Electrochemical Lactate Biosensors Based on Prussian Blue Nanoparticles
We report on the novel electrochemical lactate biosensors based on Prussian blue nanoparticles. The immobilization of lactate oxidase was performed through drop-casting on the sensor surface of a mixture containing enzyme, (3-aminopropyl)triethoxysilane and isopropyl alcohol. The apparent Michaelis constant and inactivation constant were determined (0.29 ± 0.03 mM and 0.042 ± 0.002 min−1, respectively) and compared with values obtained for biosensors based on Prussian blue films. The developed lactate biosensors are not inferior in characteristics to those previously known, while the manufacturing process is less laborious. Obtained values also indicate that lactate biosensors based on Prussian blue nanoparticles and lactate oxidase have sufficient sensitivity and operational stability for analytical application in medical and biological research.
- 15 March 2023
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 935
On-body hypoxia monitor based on lactate biosensors with a tunable concentration range
- 15 March 2023
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 935
On-body hypoxia monitor based on lactate biosensors with a tunable concentration range
- Open Access
- 9 February 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (2) , 250
Single Printing Step Prussian Blue Bulk-Modified Transducers for Oxidase-Based Biosensors
We report on hydrogen peroxide sensors made through a single printing step with carbon ink containing catalytically synthesized Prussian blue nanoparticles. Despite their reduced sensitivity, the resulting bulk-modified sensors displayed both a wider linear calibration range (5 × 10−7–1 × 10−3 M) and an approximately four times lower detection limit versus the surface-modified sensors due to the dramatically decreased noise resulting in, on average, a six times higher signal-to-noise ratio. The corresponding glucose and lactate biosensors demonstrated similar and even higher sensitivities compared to those of biosensors based on surface-modified transducers. The biosensors have been validated through analysis of human serum. The decreased time and cost for production of single printing step bulk-modified transducers, as well as their analytical performance characteristics, which are advantageous over conventional surface-modified ones, would be expected to enable their wide use in (bio)sensorics.
- 9 February 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (2) , 250
Open AccessSingle Printing Step Prussian Blue Bulk-Modified Transducers for Oxidase-Based Biosensors
We report on hydrogen peroxide sensors made through a single printing step with carbon ink containing catalytically synthesized Prussian blue nanoparticles. Despite their reduced sensitivity, the resulting bulk-modified sensors displayed both a wider linear calibration range (5 × 10−7–1 × 10−3 M) and an approximately four times lower detection limit versus the surface-modified sensors due to the dramatically decreased noise resulting in, on average, a six times higher signal-to-noise ratio. The corresponding glucose and lactate biosensors demonstrated similar and even higher sensitivities compared to those of biosensors based on surface-modified transducers. The biosensors have been validated through analysis of human serum. The decreased time and cost for production of single printing step bulk-modified transducers, as well as their analytical performance characteristics, which are advantageous over conventional surface-modified ones, would be expected to enable their wide use in (bio)sensorics.
- 9 January 2023
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 380, 133337
Simultaneous noninvasive monitoring of diabetes and hypoxia using core-shell nanozyme – oxidase enzyme biosensors
- 9 January 2023
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 380, 133337
Simultaneous noninvasive monitoring of diabetes and hypoxia using core-shell nanozyme – oxidase enzyme biosensors
- 10 June 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (25) , 9201-9207
Ultrastable Lactate Biosensor Linearly Responding in Whole Sweat for Noninvasive Monitoring of Hypoxia
We report on the lactate biosensor with linear calibration range from 0.5 to 100 mM, which encircles possible levels of this metabolite concentration in both human sweat and blood. The linear calibration range at high analyte concentrations, which exceeds the Michaelis constant of lactate oxidase by several orders of magnitude, is provided by an additional perfluorosulfonated ionomer diffusion membrane. In contrast to the known lactate biosensors, which retain their response within less than a couple of hours, the reported system displays 100% response for dozens of hours even upon high analyte concentrations. The biosensors with an additional diffusion-limiting membrane have been validated for lactate detection both in human blood serum and in undiluted human sweat shortly after its secretion. Both linear response in the entire range of blood and sweat lactate concentrations and ultrahigh operational stability would provide the use of the elaborated biosensor in wearable devices for the monitoring of hypoxia.
- 10 June 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (25) , 9201-9207
Ultrastable Lactate Biosensor Linearly Responding in Whole Sweat for Noninvasive Monitoring of Hypoxia
We report on the lactate biosensor with linear calibration range from 0.5 to 100 mM, which encircles possible levels of this metabolite concentration in both human sweat and blood. The linear calibration range at high analyte concentrations, which exceeds the Michaelis constant of lactate oxidase by several orders of magnitude, is provided by an additional perfluorosulfonated ionomer diffusion membrane. In contrast to the known lactate biosensors, which retain their response within less than a couple of hours, the reported system displays 100% response for dozens of hours even upon high analyte concentrations. The biosensors with an additional diffusion-limiting membrane have been validated for lactate detection both in human blood serum and in undiluted human sweat shortly after its secretion. Both linear response in the entire range of blood and sweat lactate concentrations and ultrahigh operational stability would provide the use of the elaborated biosensor in wearable devices for the monitoring of hypoxia.
- 6 January 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 202, 113970
Simultaneous monitoring of sweat lactate content and sweat secretion rate by wearable remote biosensors
- 6 January 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 202, 113970
Simultaneous monitoring of sweat lactate content and sweat secretion rate by wearable remote biosensors
- Open Access
- 6 December 2021
- Published by MDPI AG in Chemosensors
- Vol. 9 (12) , 344
Core-Shell Iron-Nickel Hexacyanoferrate Nanoparticle-Based Sensors for Hydrogen Peroxide Scavenging Activity
To access hydrogen peroxide scavenging activity, we propose a sensor based on core-shell iron-nickel hexacyanoferrate nanoparticles. On the one hand, the sensor preparation procedure is simple: syringing the nanoparticles suspension with subsequent annealing. On the other hand, the sensor demonstrates a stable response to 0.05 mM of H2O2 within one hour, which is sufficient for the evaluation of antioxidant activity (AO). The analytical performance characteristics of the sensor (0.5–0.6 A M−1 cm−2, detection limit 1.5 × 10−7 M and linear dynamic range 1–1000 µM) are leads to advantages over the sensor based on Prussian Blue films. The pseudo-first-order constant of hydrogen peroxide scavenging was chosen as a characteristic value of AO. The latter for trolox (standard antioxidant) was found to be linearly dependent on its concentration, thus allowing for the evaluation of antioxidant activity in trolox equivalents. The approach was validated by analyzing real beverage samples. Both the simplicity of sensor preparation and an expressiveness of analytical procedure would obviously provide a wide use of the proposed approach in the evaluation of antioxidant activity.
- 6 December 2021
- Published by MDPI AG in Chemosensors
- Vol. 9 (12) , 344
Open AccessCore-Shell Iron-Nickel Hexacyanoferrate Nanoparticle-Based Sensors for Hydrogen Peroxide Scavenging Activity
To access hydrogen peroxide scavenging activity, we propose a sensor based on core-shell iron-nickel hexacyanoferrate nanoparticles. On the one hand, the sensor preparation procedure is simple: syringing the nanoparticles suspension with subsequent annealing. On the other hand, the sensor demonstrates a stable response to 0.05 mM of H2O2 within one hour, which is sufficient for the evaluation of antioxidant activity (AO). The analytical performance characteristics of the sensor (0.5–0.6 A M−1 cm−2, detection limit 1.5 × 10−7 M and linear dynamic range 1–1000 µM) are leads to advantages over the sensor based on Prussian Blue films. The pseudo-first-order constant of hydrogen peroxide scavenging was chosen as a characteristic value of AO. The latter for trolox (standard antioxidant) was found to be linearly dependent on its concentration, thus allowing for the evaluation of antioxidant activity in trolox equivalents. The approach was validated by analyzing real beverage samples. Both the simplicity of sensor preparation and an expressiveness of analytical procedure would obviously provide a wide use of the proposed approach in the evaluation of antioxidant activity.