Balázs Vince Nagy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Balázs Vince Nagy has a total of 172 co-authors. Here are the top co-authors by number of shared publications:
- Dora Fix Ventura
Department of Experimental Psychology, Psychology Institute University of São Paulo São Paulo Brazil
17 shared publications - Jan Kremers
Section for Retinal Physiology, Department of Ophthalmology, University Hospital Erlangen, Erlangen, Germany
6 shared publications - Aline de Faria Lemos
Department of Mechatronics, Optics and Mechanical Engineering Informatics, Budapest University of Technology and Economics, Budapest, Hungary
5 shared publications - Marcelo Fernandes Costa
Departamento de Psicologia Experimental, Instituto de Psicologia, Universidade de São Paulo, São Paulo, Brazil
5 shared publications Mirella Telles Salgueiro Barboni
Department of Ophthalmology, Facalty of Health science, Semmelweis University, Vas utca 17, H-1088 Budapest, Hungary
5 shared publications- Gloria Liliana Duque Chica
Faculty of Exact and Applied Sciences University Institution ITM Medellín Colombia
4 shared publications
Latest Publications
- Open Access
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
PolySpect: A compact polychromator concept for charge exchange measurements
Localized measurements of ion temperature and bulk flow velocity using charge-exchange recombination spectroscopy are essential for transport and stability studies on magnetic confinement devices such as the Wendelstein 7-X (W7-X) stellarator. On W7-X, the active C VI signal driven by a diagnostic sodium beam is weak, while conventional dispersion spectrometers discard much of the collected light at their entrance slit, preventing photon-noise-limited performance at high time resolution. We present PolySpect, a compact, slitless polychromator that replaces the dispersing grating with the deterministic angular wavelength shift of a hard-coated ultra-narrowband interference filter. Light reflected by the filter is recycled by off-axis micro-prism pairs and returned at successively shifted incidence angles, so that a single filter samples several wavelength ranges across the line profile and feeds fast detectors. This compact system can process light from a few fibers with a diameter of 600-μm and NA = 0.22. A Python forward model maps the prism geometry onto per-pass incidence angles and predicts the absolute photon count rate per channel, providing the input data for the user for the ion-temperature and velocity inversion. An optical design and an optomechanical prototype were built and tested with a monochromator-narrowed light source. The tests confirmed the recycling principle but showed that the present prism reflectivity is insufficient to drive all channels. After laboratory testing with improved prisms, an optimized filter is planned to be purchased in preparation for the first experimental demonstration.
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Open AccessPolySpect: A compact polychromator concept for charge exchange measurements
Localized measurements of ion temperature and bulk flow velocity using charge-exchange recombination spectroscopy are essential for transport and stability studies on magnetic confinement devices such as the Wendelstein 7-X (W7-X) stellarator. On W7-X, the active C VI signal driven by a diagnostic sodium beam is weak, while conventional dispersion spectrometers discard much of the collected light at their entrance slit, preventing photon-noise-limited performance at high time resolution. We present PolySpect, a compact, slitless polychromator that replaces the dispersing grating with the deterministic angular wavelength shift of a hard-coated ultra-narrowband interference filter. Light reflected by the filter is recycled by off-axis micro-prism pairs and returned at successively shifted incidence angles, so that a single filter samples several wavelength ranges across the line profile and feeds fast detectors. This compact system can process light from a few fibers with a diameter of 600-μm and NA = 0.22. A Python forward model maps the prism geometry onto per-pass incidence angles and predicts the absolute photon count rate per channel, providing the input data for the user for the ion-temperature and velocity inversion. An optical design and an optomechanical prototype were built and tested with a monochromator-narrowed light source. The tests confirmed the recycling principle but showed that the present prism reflectivity is insufficient to drive all channels. After laboratory testing with improved prisms, an optimized filter is planned to be purchased in preparation for the first experimental demonstration.
- 30 August 2026
- Published by Wiley in Color Research & Application
- Vol. 51 (5)
Chromaticity Points of Real Spectra Outside the CIE Chromaticity Diagram
When an expert in colorimetry is asked whether the chromaticity point of a real spectrum can fall outside the CIE xy chromaticity diagram, the immediate answer will probably be something like “No! That is not possible!” Comprehensive investigations revealed that the concept of convexity is violated in several specific regions of the chromaticity diagram. Given that the deviations are only visible at the 5th decimal place, the results do not influence most calculations or practical measurements. However, since a fundamental property—convexity—of the chromaticity diagram relevant to the theory of colorimetry has been disproved, the color matching functions must be revised to maintain theoretical integrity.
- 30 August 2026
- Published by Wiley in Color Research & Application
- Vol. 51 (5)
Chromaticity Points of Real Spectra Outside the CIE Chromaticity Diagram
When an expert in colorimetry is asked whether the chromaticity point of a real spectrum can fall outside the CIE xy chromaticity diagram, the immediate answer will probably be something like “No! That is not possible!” Comprehensive investigations revealed that the concept of convexity is violated in several specific regions of the chromaticity diagram. Given that the deviations are only visible at the 5th decimal place, the results do not influence most calculations or practical measurements. However, since a fundamental property—convexity—of the chromaticity diagram relevant to the theory of colorimetry has been disproved, the color matching functions must be revised to maintain theoretical integrity.
- Open Access
- 25 June 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 230
Mitigation of first mirror degradation in EU-DEMO optical diagnostics: A coupled ERO2.0 and optical performance analysis
- 25 June 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 230
Open AccessMitigation of first mirror degradation in EU-DEMO optical diagnostics: A coupled ERO2.0 and optical performance analysis
- Open Access
- 21 February 2026
- Published by Elsevier in SSRN Electronic Journal
Mitigation of First Mirror Degradation in EU-DEMO Optical Diagnostics: A Coupled ERO2.0 and Optical Performance Analysis
EU-DEMO is a fusion power plant concept being developed within EUROfusion. Building on experience gained on recent fusion experiments and the development of ITER, its objective is to demonstrate the feasibility of reliable, power-plant-relevant operation of a fusion device. In contrast to ITER, a power plant is expected to host only those diagnostic systems that directly contribute to plant monitoring and control. Several of these systems are based on optical principles, and the condition of the first mirror heavily influences the performance of the systems. Previous studies have investigated how the mirror surface is affected by erosion driven by high-energy neutral particles and the deposition of various impurities. In the present study, it assessed how the expected lifetime and performance of a conceptually designed, gas-flow-protected optical diagnostic system changes as selected design parameters are varied. To this end, the extent of mirror-surface erosion as a function of gas pressure and mirror position was assessed. The results indicate that, for the investigated cases, the imaging quality remains essentially unchanged, and the predicted erosion magnitude suggests only minor first-mirror surface degradation. In addition, a deliberately conservative worst-case scenario was evaluated by introducing a 20% diffuse reflectivity component to represent strong surface roughening; even under this assumption, the system maintains its imaging performance, while the collected power is reduced as expected.
- 21 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMitigation of First Mirror Degradation in EU-DEMO Optical Diagnostics: A Coupled ERO2.0 and Optical Performance Analysis
EU-DEMO is a fusion power plant concept being developed within EUROfusion. Building on experience gained on recent fusion experiments and the development of ITER, its objective is to demonstrate the feasibility of reliable, power-plant-relevant operation of a fusion device. In contrast to ITER, a power plant is expected to host only those diagnostic systems that directly contribute to plant monitoring and control. Several of these systems are based on optical principles, and the condition of the first mirror heavily influences the performance of the systems. Previous studies have investigated how the mirror surface is affected by erosion driven by high-energy neutral particles and the deposition of various impurities. In the present study, it assessed how the expected lifetime and performance of a conceptually designed, gas-flow-protected optical diagnostic system changes as selected design parameters are varied. To this end, the extent of mirror-surface erosion as a function of gas pressure and mirror position was assessed. The results indicate that, for the investigated cases, the imaging quality remains essentially unchanged, and the predicted erosion magnitude suggests only minor first-mirror surface degradation. In addition, a deliberately conservative worst-case scenario was evaluated by introducing a 20% diffuse reflectivity component to represent strong surface roughening; even under this assumption, the system maintains its imaging performance, while the collected power is reduced as expected.
- 1 November 2025
- Published by International Commission on Illumination
- p. 903-910
HYPERSPECTRAL IMAGING IN AGRICULTURE – EVALUATING THE SPECTRAL DEPENDENCY OF VEGETATION INDICES
Vegetation indices have been in active use for over five decades. They are remote sensing indicators derived from surface reflectance data to highlight various vegetation-related properties. Their popularity stems partly from their simplicity. Each index is computed by simple formulas using the pixel values of a handful of multispectral bands. However, the loose definition of spectral bands introduces a device-specific discrepancy to the results as the spectral sensitivity can vary significantly between different systems and slightly even between different units of the same model. This paper uses hyperspectral aerial images to investigate the cross-instrument differences of some popular vegetation indices. The spectral characteristics of various multispectral instruments are reconstructed from the much narrower hyperspectral bands, creating the device-specific projections of the dataset. The differences between devices are presented using these transformed values.
- 1 November 2025
- Published by International Commission on Illumination
- p. 903-910
HYPERSPECTRAL IMAGING IN AGRICULTURE – EVALUATING THE SPECTRAL DEPENDENCY OF VEGETATION INDICES
Vegetation indices have been in active use for over five decades. They are remote sensing indicators derived from surface reflectance data to highlight various vegetation-related properties. Their popularity stems partly from their simplicity. Each index is computed by simple formulas using the pixel values of a handful of multispectral bands. However, the loose definition of spectral bands introduces a device-specific discrepancy to the results as the spectral sensitivity can vary significantly between different systems and slightly even between different units of the same model. This paper uses hyperspectral aerial images to investigate the cross-instrument differences of some popular vegetation indices. The spectral characteristics of various multispectral instruments are reconstructed from the much narrower hyperspectral bands, creating the device-specific projections of the dataset. The differences between devices are presented using these transformed values.
- Open Access
- 1 October 2025
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- p. 1-42
Integration of fringe projection and optical flow for 3D surface reconstruction: a novel simulation-based approach
Surface profilometry is essential in manufacturing, quality control, and biomedical imaging, where precise, noncontact surface measurements are required. Traditional techniques such as digital fringe projection (DFP) face limitations in computational efficiency, noise robustness, and handling complex geometries. This paper explores the integration of DFP and optical flow estimation as a novel approach to 3D surface reconstruction, with the aim of advancing noncontact measurement technologies. The proposed method employs phase-shifted DFP to encode surface depth and combined with optical flow techniques that estimate the pixel displacements between captured frames. A custom simulator developed in Blender 3D enables automated DFP and surface validation under controlled, reproducible conditions. Quantitative results show a normalized mean squared error (NMSE) of 0.056 and a mean error of $$6.41\,\text {px}$$ for the Sphere model, 0.126/ $$2.57\,\text {px}$$ for the Dolphin, and 0.139/ $$11.73\,\text {px}$$ for the Face. These results demonstrate competitive accuracy on smooth surfaces and highlight challenges with complex geometries. Reconstruction accuracy declines with surface complexity, primarily due to the fact that current dense optical flow models are not optimized for structured light. High-frequency details, object boundaries, and surface discontinuities often lead to local flow estimation errors, reducing accuracy on intricate shapes. Although the method has not yet exceeded traditional techniques in all metrics, it presents a promising alternative for efficient and robust surface reconstruction. This paper outlines the strengths and limitations of the method and proposes improvements to guide the future development and industrial deployment of this scalable framework.- 1 October 2025
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- p. 1-42
Open AccessIntegration of fringe projection and optical flow for 3D surface reconstruction: a novel simulation-based approach
Surface profilometry is essential in manufacturing, quality control, and biomedical imaging, where precise, noncontact surface measurements are required. Traditional techniques such as digital fringe projection (DFP) face limitations in computational efficiency, noise robustness, and handling complex geometries. This paper explores the integration of DFP and optical flow estimation as a novel approach to 3D surface reconstruction, with the aim of advancing noncontact measurement technologies. The proposed method employs phase-shifted DFP to encode surface depth and combined with optical flow techniques that estimate the pixel displacements between captured frames. A custom simulator developed in Blender 3D enables automated DFP and surface validation under controlled, reproducible conditions. Quantitative results show a normalized mean squared error (NMSE) of 0.056 and a mean error of $$6.41\,\text {px}$$ for the Sphere model, 0.126/ $$2.57\,\text {px}$$ for the Dolphin, and 0.139/ $$11.73\,\text {px}$$ for the Face. These results demonstrate competitive accuracy on smooth surfaces and highlight challenges with complex geometries. Reconstruction accuracy declines with surface complexity, primarily due to the fact that current dense optical flow models are not optimized for structured light. High-frequency details, object boundaries, and surface discontinuities often lead to local flow estimation errors, reducing accuracy on intricate shapes. Although the method has not yet exceeded traditional techniques in all metrics, it presents a promising alternative for efficient and robust surface reconstruction. This paper outlines the strengths and limitations of the method and proposes improvements to guide the future development and industrial deployment of this scalable framework. - Open Access
- 19 September 2024
- Published by Springer Nature in Experimental Mechanics
- Vol. 64 (9) , 1557-1578
Biomechanical Hand Model: Modeling and Simulating the Lateral Pinch Movement
Background: Hand movements are crucial in daily activities, sparking extensive interest and research in biomechanical models. While existing models offer valuable insights, their complexity and processing costs may limit their suitability for all applications, sometimes impeding research efficiency. Objectives: This study aimed to develop a biomechanical model of the human hand for analyzing the physiology of lateral pinch movement. Unlike conventional methodologies, this approach focuses on delivering a computationally efficient model while incorporating the trapeziometacarpal joint into the analysis. Methods: The model, which operates in a multibody environment, simulates lateral pinching movement by applying external time-varying torques to digit joints, emulating musculature, tendons, and ligaments. Torque estimation was achieved through the Euler-Lagrange approach. The model generates animated representations of the movement, aiding pathology identification and outputting dynamic variables. The model’s was validated through data acquired from asymptomatic subjects via an OptiTrack system. Results: The average disparity between the expected and obtained joint angular displacements was $$\varvec{6.06~\%}$$ and $$\varvec{1.90~\%}$$ during validation and verification stages, suggesting high fidelity in the model performance. Correlation analysis revealed strong positive linear relationships and robust correlations between the obtained and expected configuration data. Model-generated pinch postures closely resembled expected physiological patterns, with results falling within the range for asymptomatic individuals documented in the scientific literature. Conclusion: The system efficiently analyzes dynamic variables at a low computational cost, offering animated representations for pathology identification. The model’s potential for rehabilitation solutions and adaptability, coupled with its accuracy and versatility, make it an asset for advancing hand biomechanics research.- 19 September 2024
- Published by Springer Nature in Experimental Mechanics
- Vol. 64 (9) , 1557-1578
Open AccessBiomechanical Hand Model: Modeling and Simulating the Lateral Pinch Movement
Background: Hand movements are crucial in daily activities, sparking extensive interest and research in biomechanical models. While existing models offer valuable insights, their complexity and processing costs may limit their suitability for all applications, sometimes impeding research efficiency. Objectives: This study aimed to develop a biomechanical model of the human hand for analyzing the physiology of lateral pinch movement. Unlike conventional methodologies, this approach focuses on delivering a computationally efficient model while incorporating the trapeziometacarpal joint into the analysis. Methods: The model, which operates in a multibody environment, simulates lateral pinching movement by applying external time-varying torques to digit joints, emulating musculature, tendons, and ligaments. Torque estimation was achieved through the Euler-Lagrange approach. The model generates animated representations of the movement, aiding pathology identification and outputting dynamic variables. The model’s was validated through data acquired from asymptomatic subjects via an OptiTrack system. Results: The average disparity between the expected and obtained joint angular displacements was $$\varvec{6.06~\%}$$ and $$\varvec{1.90~\%}$$ during validation and verification stages, suggesting high fidelity in the model performance. Correlation analysis revealed strong positive linear relationships and robust correlations between the obtained and expected configuration data. Model-generated pinch postures closely resembled expected physiological patterns, with results falling within the range for asymptomatic individuals documented in the scientific literature. Conclusion: The system efficiently analyzes dynamic variables at a low computational cost, offering animated representations for pathology identification. The model’s potential for rehabilitation solutions and adaptability, coupled with its accuracy and versatility, make it an asset for advancing hand biomechanics research. - Open Access
- 13 July 2024
- Published by Periodica Polytechnica Budapest University of Technology and Economics in Periodica Polytechnica Mechanical Engineering
- Vol. 68 (3) , 187-195
Oscillatory Potential-based Characterization of the Human Light-adapted Electroretinogram Using Discrete Wavelet Transform
Purpose: Our aim was to apply multiple discrete wavelet transformation (DWT) types to healthy light-adapted (cone) electroretinogram (ERG) signals in order to optimize DWT analysy in ERG. Oscillatory potentials (OP) were individually extracted from the signals and used to calculate an indicator for ERG analysis.Methods: Light-adapted (LA) 3.0 cd.s/m2 ISCEV standard ERGs were recorded from both eyes of 15 healthy volunteers (mean age: 36.9 ± 13.0 years old; 13 females). LA ERG signal components, such as b-wave and OPs, were analyzed using the discrete wavelet transformation (DWT). An index (%OPi) was proposed to estimate the individual oscillatory potentials (OP1-OP5) by calculating the coefficient ratio of the OP to b-wave. Multiple mother wavelet functions (i.e., Daubechies, Symlet, and Coiflet) with five orders were applied and compared statistically using Wilcoxon tests and paired t-test comparisons with Bonferroni posthoc analyses (p < 0.005). Results: OP4 shows the most energy at both low and high-frequency bands (80Hz and 160Hz), while OP2 has lower energy at the low-frequency band (80Hz) and higher energy at the high-frequency band (160Hz). The %OP2 is the largest among the five individual OPs. %OPs obtained with different wavelet functions differ from each other. Db2 and sym2 seem to be the optimal wavelets for analyzing light-adapted ERG components.Conclusion: Individual OPs of the light-adapted ERG obtained with the DWT analysis may characterize different levels of retinal dysfunction. The %OPi may serve as an indicator in ERG analysis.
- 13 July 2024
- Published by Periodica Polytechnica Budapest University of Technology and Economics in Periodica Polytechnica Mechanical Engineering
- Vol. 68 (3) , 187-195
Open AccessOscillatory Potential-based Characterization of the Human Light-adapted Electroretinogram Using Discrete Wavelet Transform
Purpose: Our aim was to apply multiple discrete wavelet transformation (DWT) types to healthy light-adapted (cone) electroretinogram (ERG) signals in order to optimize DWT analysy in ERG. Oscillatory potentials (OP) were individually extracted from the signals and used to calculate an indicator for ERG analysis.Methods: Light-adapted (LA) 3.0 cd.s/m2 ISCEV standard ERGs were recorded from both eyes of 15 healthy volunteers (mean age: 36.9 ± 13.0 years old; 13 females). LA ERG signal components, such as b-wave and OPs, were analyzed using the discrete wavelet transformation (DWT). An index (%OPi) was proposed to estimate the individual oscillatory potentials (OP1-OP5) by calculating the coefficient ratio of the OP to b-wave. Multiple mother wavelet functions (i.e., Daubechies, Symlet, and Coiflet) with five orders were applied and compared statistically using Wilcoxon tests and paired t-test comparisons with Bonferroni posthoc analyses (p < 0.005). Results: OP4 shows the most energy at both low and high-frequency bands (80Hz and 160Hz), while OP2 has lower energy at the low-frequency band (80Hz) and higher energy at the high-frequency band (160Hz). The %OP2 is the largest among the five individual OPs. %OPs obtained with different wavelet functions differ from each other. Db2 and sym2 seem to be the optimal wavelets for analyzing light-adapted ERG components.Conclusion: Individual OPs of the light-adapted ERG obtained with the DWT analysis may characterize different levels of retinal dysfunction. The %OPi may serve as an indicator in ERG analysis.
- Open Access
- 1 April 2022
- Published by Muszaki Tudomanyos Kozlemenyek in Műszaki Tudományos Közlemények
- Vol. 16 (1) , 58-63
Chromatic Discrimination Towards the Confusion Points
In this paper chromatic discrimination thresholds of normal colour-observers are analysed. Measurements were obtained with the Cambridge Colour Test, in different reference points. The results show differences in terms of the reference chromaticities. Reference points within the gamut of a CRT display were found where thresholds of normal colour observers measured towards the confusion points exceeded the normative upper threshold limit of normal colour observers. The discrimination thresholds estimated towards the confusion lines based on Trivector measurements exceeded the thresholds estimated by the Ellipse tests. Our results indicate that in case of determination of discrimination ellipses, measurements towards the confusion points are recommended.
- 1 April 2022
- Published by Muszaki Tudomanyos Kozlemenyek in Műszaki Tudományos Közlemények
- Vol. 16 (1) , 58-63
Open AccessChromatic Discrimination Towards the Confusion Points
In this paper chromatic discrimination thresholds of normal colour-observers are analysed. Measurements were obtained with the Cambridge Colour Test, in different reference points. The results show differences in terms of the reference chromaticities. Reference points within the gamut of a CRT display were found where thresholds of normal colour observers measured towards the confusion points exceeded the normative upper threshold limit of normal colour observers. The discrimination thresholds estimated towards the confusion lines based on Trivector measurements exceeded the thresholds estimated by the Ellipse tests. Our results indicate that in case of determination of discrimination ellipses, measurements towards the confusion points are recommended.
- Open Access
- 24 September 2021
- Published by Springer Nature in Documenta Ophthalmologica
- Vol. 144 (3) , 191-202
Effects of fixed cutoff filtering on dark- and light-adapted ERG components and the application of variable cutoff filter
Purpose: Human oscillatory potentials (OPs) are derived from dark-adapted (DA) electroretinograms (ERGs) with fixed frequency cutoff filters while light-adapted (LA) OPs are generally not isolated from ERGs. Our purpose was to analyze the effect of cutoff frequencies on DA and LA ERG components using a series of fixed and variable filters. Methods: DA and LA ERGs were recorded from 10 healthy eyes of 10 subjects (mean age = 20.5 ± 6.7 years) following ISCEV standards. Each signal was filtered in the Fourier domain to acquire slow (a- and b-waves; below cutoff frequency) and fast (OPs; above cutoff frequency) components. Fixed cutoff frequencies ranged from 60 to 105 Hz and a variable cutoff frequency was calculated. Results were analyzed with statistical tests and specific models. Results: DA ERG components were slightly influenced by the filter cutoff frequency. In contrast, fixed and variable filters significantly changed LA components: the lower the cutoff frequency the smaller the b-wave and OP3 and the higher the OP2/OP4 amplitudes. Analyzing the filter frequency limits a transition range between 68.9 Hz and 83.9 Hz was observed where amplitudes vary. Conclusions: The present report shows that DA OPs may be isolated from ERGs using filtering procedures with high-pass cutoff frequency at about 75 Hz as recommended by ISCEV. On the other hand, the spectral distribution of low-frequency and high-frequency LA ERG components may overlap. Accordingly, filtering the signal using different cutoff frequencies is not necessarily separating b-wave and OPs.
- 24 September 2021
- Published by Springer Nature in Documenta Ophthalmologica
- Vol. 144 (3) , 191-202
Open AccessEffects of fixed cutoff filtering on dark- and light-adapted ERG components and the application of variable cutoff filter
Purpose: Human oscillatory potentials (OPs) are derived from dark-adapted (DA) electroretinograms (ERGs) with fixed frequency cutoff filters while light-adapted (LA) OPs are generally not isolated from ERGs. Our purpose was to analyze the effect of cutoff frequencies on DA and LA ERG components using a series of fixed and variable filters. Methods: DA and LA ERGs were recorded from 10 healthy eyes of 10 subjects (mean age = 20.5 ± 6.7 years) following ISCEV standards. Each signal was filtered in the Fourier domain to acquire slow (a- and b-waves; below cutoff frequency) and fast (OPs; above cutoff frequency) components. Fixed cutoff frequencies ranged from 60 to 105 Hz and a variable cutoff frequency was calculated. Results were analyzed with statistical tests and specific models. Results: DA ERG components were slightly influenced by the filter cutoff frequency. In contrast, fixed and variable filters significantly changed LA components: the lower the cutoff frequency the smaller the b-wave and OP3 and the higher the OP2/OP4 amplitudes. Analyzing the filter frequency limits a transition range between 68.9 Hz and 83.9 Hz was observed where amplitudes vary. Conclusions: The present report shows that DA OPs may be isolated from ERGs using filtering procedures with high-pass cutoff frequency at about 75 Hz as recommended by ISCEV. On the other hand, the spectral distribution of low-frequency and high-frequency LA ERG components may overlap. Accordingly, filtering the signal using different cutoff frequencies is not necessarily separating b-wave and OPs.