CPChien-Sing Poon

Chien-Sing Poon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chien-Sing Poon has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Depth-sensitive cerebral blood flow and low-frequency oscillations for consciousness assessment using time-domain diffuse correlation spectroscopy

    by Sahar Sabaghian, Chien-Sing Poon, Carsi Kim, Christopher H. Moore, Irfaan Dar, Timothy M. Rambo, Aaron J. Miller, Sujith Swarna, Noah Lubin, Sima Mofakkam, et al.

    Significance: Continuous bedside monitoring of cerebral blood flow (CBF) and neurovascular dynamics is important for assessing brain function and detecting secondary injury in patients with traumatic brain injury (TBI) and disorders of consciousness (DOC). However, most neuroimaging modalities lack portability or depth specificity for use in neurocritical care settings.Aim: This study evaluates the feasibility of using time-domain diffuse correlation spectroscopy (TD-DCS) for depth-sensitive monitoring of cerebral blood flow and low-frequency oscillations (LFOs) in healthy individuals and patients with DOC.Approach: A 1064-nm TD-DCS system equipped with superconducting nanowire single-photon detectors (SNSPDs) was used to acquire resting-state measurements from 25 healthy adults and five TBI patients with DOC. Photon arrival times were temporally gated to separate superficial and cortical-weighted signals. Cerebral blood flow index and LFO characteristics were analyzed using power spectral density within the Slow-5, Slow-4, and Slow-3 frequency bands. Task-evoked responses were also assessed using an auditory “smile” command paradigm.Results: Compared with healthy controls, DOC patients exhibited altered resting-state LFO amplitude and spectral distribution, with a relative shift toward slower oscillatory components. Task-evoked measurements demonstrated clear hemodynamic responses in healthy participants, while responses in DOC patients were attenuated and more transient.Conclusion: TD-DCS provides a noninvasive and depth-resolved approach for monitoring cerebral hemodynamics and spontaneous oscillatory activity, supporting its potential as a portable bedside tool for assessing cerebrovascular dynamics and residual cortical responsiveness in neurocritical-care patients.


  • Open Access

    Depth-sensitive assessment of cerebral blood flow and low-frequency oscillations after traumatic brain injury in mice using time-domain diffuse correlation spectroscopy

    by Sahar Sabaghian, Chien-Sing Poon, Dharminder S. Langri, Timothy M. Rambo, Aaron J. Miller, Brandon Foreman, Ulas Sunar

    Traumatic brain injury (TBI) can lead to long-lasting impairments in cerebral perfusion, making early detection of microvascular changes critical for guiding clinical interventions. We employed time-domain diffuse correlation spectroscopy (TD-DCS) at 1064 nm to noninvasively quantify depth-resolved cerebral blood flow (CBF) and low-frequency oscillations (LFOs) in a mouse model of closed-head injury. By analyzing earlier photon arrivals (with greater superficial weighting) and later photon arrivals (with enhanced sensitivity to deeper tissue), we identified a significant drop in CBF shortly after injury, with partial recovery observed at 2 h post-trauma. Power spectral analysis of the blood flow index (BFI, a diffusion coefficient proportional to CBF) revealed significant alterations in LFO bands, particularly in slow-5 (0.01 to 0.027 Hz) and slow-3 (0.073 to 0.198 Hz) ranges. These differences, assessed using a paired Wilcoxon rank-sum test (p<0.05), were more pronounced than BFI alterations alone, indicating that LFOs may serve as sensitive biomarkers of neurovascular disruption. Our findings demonstrate the feasibility of TD-DCS for relative depth-sensitive monitoring of cerebral hemodynamics and oscillatory dynamics after TBI and highlight its potential utility in translational neurotrauma research.


  • First-in-clinical application of a time-gated diffuse correlation spectroscopy system at 1064 nm using superconducting nanowire single photon detectors in a neuro intensive care unit

    by Chien-Sing Poon, Dharminder S. Langri, Benjamin Rinehart, Timothy M. Rambo, Aaron J. Miller, Brandon Foreman, Ulas Sunar

    Recently proposed time-gated diffuse correlation spectroscopy (TG-DCS) has significant advantages compared to conventional continuous wave (CW)-DCS, but it is still in an early stage and clinical capability has yet to be established. The main challenge for TG-DCS is the lower signal-to-noise ratio (SNR) when gating for the deeper traveling late photons. Longer wavelengths, such as 1064 nm have a smaller effective attenuation coefficient and a higher power threshold in humans, which significantly increases the SNR. Here, we demonstrate the clinical utility of TG-DCS at 1064 nm in a case study on a patient with severe traumatic brain injury admitted to the neuro-intensive care unit (neuroICU). We showed a significant correlation between TG-DCS early (ρ = 0.67) and late (ρ = 0.76) gated against invasive thermal diffusion flowmetry. We also analyzed TG-DCS at high temporal resolution (50 Hz) to elucidate pulsatile flow data. Overall, this study demonstrates the first clinical translation capability of the TG-DCS system at 1064 nm using a superconducting nanowire single-photon detector.


  • Open Access

    First-in-clinical application of a time-gated diffuse correlation spectroscopy system at 1064nm using superconducting nanowire single photon detectors

    by Chien-Sing Poon, Dharminder S. Langri, Benjamin Rinehart, Timothy M. Rambo, Aaron J. Miller, Brandon Foreman, Ulas Sunar

    Recently proposed time-gated DCS (TG-DCS) has significant advantages compared to conventional CW-DCS, but it is still in an early stage and clinical capability has yet to be established. The main challenge for TG-DCS is the lower SNR when gating for the deeper travelling late photons. Longer wavelengths, such as 1064nm have a smaller effective attenuation coefficient and a higher power threshold in humans, which significantly increases the SNR. Here, we demonstrate the clinical utility of TG-DCS at 1064nm in a case study on a patient with severe traumatic brain injury admitted to the neuroscience intensive care unit (NSICU). We showed a significant correlation between TG-DCS early (ρ = 0.67) and late (ρ = 0.76) gated against invasive thermal diffusion flowmetry. We also analyzed TG-DCS at high temporal resolution (50 Hz) to elucidate pulsatile flow data. Overall, this study demonstrates the first clinical translation capability of the TG-DCS system at 1064nm using superconducting nanowire single photon detector.

  • Open Access

    Noninvasive optical monitoring of cerebral blood flow and EEG Spectral responses after Severe Traumatic Brain Injury: A Case Report

    by Chien-Sing Poon, Benjamin Rinehart, Dharminder S. Langri, Timothy M. Rambo, Aaron J. Miller, Brandon Foreman, Ulas Sunar

    Survivors of severe brain injury may require care in a neurointensive care unit (neuro-ICU), where the brain is vulnerable to secondary brain injury. Thus, there is a need for noninvasive, bedside, continuous cerebral blood flow monitoring approaches in the neuro-ICU. Our goal is to address this need through combined measurements of EEG and functional optical spectroscopy (EEG-Optical) instrumentation and analysis to provide a complementary fusion of data about brain activity and function. The present case demonstrates in a patient with traumatic brain injury, noninvasive cerebral blood flow transients can be recorded that correlate with gold-standard invasive measurements and with the frequency content changes in the EEG data during clinical care.


  • Deep learning model for ultrafast quantification of blood flow in diffuse correlation spectroscopy

    by Chien-Sing Poon, Feixiao Long, Ulas Sunar

    Diffuse correlation spectroscopy (DCS) is increasingly used in the optical imaging field to assess blood flow in humans due to its non-invasive, real-time characteristics and its ability to provide label-free, bedside monitoring of blood flow changes. Previous DCS studies have utilized a traditional curve fitting of the analytical or Monte Carlo models to extract the blood flow changes, which are computationally demanding and less accurate when the signal to noise ratio decreases. Here, we present a deep learning model that eliminates this bottleneck by solving the inverse problem more than 2300% faster, with equivalent or improved accuracy compared to the nonlinear fitting with an analytical method. The proposed deep learning inverse model will enable real-time and accurate tissue blood flow quantification with the DCS technique.


  • Open Access

    Deep learning model for ultrafast quantification of blood flow in diffuse correlation spectroscopy

    by Chien-Sing Poon, Feixiao Long, Ulas Sunar

    Diffuse correlation spectroscopy (DCS) is increasingly used in the optical imaging field to assess blood flow in humans due to its non-invasive, real-time characteristics and its ability to provide label-free, bedside monitoring of blood flow changes. Previous DCS studies have utilized a traditional curve fitting of the analytical or Monte Carlo models to extract the blood flow changes, which are computationally demanding and less accurate when the signal to noise ratio decreases. Here, we present a deep learning model that eliminates this bottleneck by solving the inverse problem more than 2300% faster, with equivalent or improved accuracy compared to the nonlinear fitting with an analytical method. The proposed deep learning inverse model will enable real-time and accurate tissue blood flow quantification with the DCS technique.


  • Time-resolved mesoscopic imaging of a whole animal by FastFLIM

    by Yuansheng Sun, Chien Sing Poon, Hailin Qiu, Ulas C. Coskun, Shih-Chu Jeff Liao, Sunil Shah, Beniamino Barbieri, Ulas Sunar

    The mesoscopic scale is between microscopic and macroscopic scales. In life sciences, mesoscopic imaging allows scientists to record, track and study details of biological systems in the context of an organ, body part, or organism. Mesoscopic imaging techniques have been developed for medical and clinical research, such as drug delivery, cancer diagnosis, etc. Especially when combined with novel nanoparticles and organic dyes in the near-infrared spectral regime, the mesoscopic imaging can probe deeper parts of the animal body. Here, we describe a timeresolved mesoscopic imaging approach, which can image deep inside of the whole mouse noninvasively. In addition, it uses the FastFLIM technique to measure the lifetime of the fluorescent probe. Since the lifetime carries information about the probe’s local microenvironment such as temperature, pH, ion concentration, etc., the lifetime imaging map obtained by the FastFLIM-mesoscope allows tracking quantitative dynamics of the probes in the whole animal body. The technique can also be used for quantitative intrinsic NADH metabolism mapping for real time monitoring of mitochondrial function. Here, we will show mesoscopic-scale NADH imaging in an oral cancer model.

  • Resting‐state functional connectivity measured by diffuse correlation spectroscopy

    by Jun Li, Chien‐Sing Poon, Jeremy Kress, Daniel J. Rohrbach, Ulas Sunar

    Near‐infrared diffuse correlation spectroscopy (DCS) is used to record spontaneous cerebral blood flow fluctuations in the frontal cortex. Nine adult subjects participated in the experiments, in which 8‐minute spontaneous fluctuations were simultaneously recorded from the left and right dorsolateral and inferior frontal regions. Resting‐state functional connectivity (RSFC) was measured by the temporal correlation of the low frequency fluctuations. Our data shows the RSFC within the dorsolateral region is significantly stronger than that between the inferior and dorsolateral regions, in line with previous observations with functional near‐infrared spectroscopy. This indicates that DCS is capable of investigating brain functional connectivity in terms of cerebral blood flow.


  • Open Access

    Noninvasive mesoscopic imaging of actinic skin damage using spatial frequency domain imaging

    by Jeffrey B. Travers, Chien Poon, Daniel J. Rohrbach, Nathan M. Weir, Elizabeth Cates, Faye Hager, Ulas Sunar

    For prevention and accurate intervention planning, it is crucial to predict if lesions will progress towards cancer. In this study, we investigated the change in optical properties and vascular parameters to characterize skin tissue from mild photodamage to actinic keratosis (AK). Multi-wavelength spatial frequency domain imaging (SFDI) measurements were performed on three patients with clinically normal skin, as well as pre-cancerous actinic keratosis lesions. Our results indicate that there exist significant differences in both optical and vascular parameters between these patients, and that these parameters can be early biomarkers of neoplasia. Ultimately, clinicians can use this noninvasive approach for frequent monitoring of high-risk population.