DSDaisuke Sakota

Daisuke Sakota

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Daisuke Sakota has a total of 68 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Technical challenges and prospects for ex vivo heart perfusion: a republication of the review published in Japanese journal of artificial organs

    by Daisuke Sakota, Ryo Kosaka, Eiki Nagaoka, Tomoki Tahara, Katsuhiro Ohuchi, Tetsuhito Kigata, Ichiro Sakanoue, Tomoyuki Fujita, Toshihiro Okamoto

    Ex vivo heart perfusion (EVHP) has been clinically utilized for the preservation and functional assessment of donor hearts before heart transplantation. In the field of EVHP research, perfusion methods are often referred to as “modes”. This manuscript describes the characteristics of the EVHP modes that have been proposed to date. The resting mode (Langendorff mode) involves cannulation of the aorta and exclusive coronary perfusion. It is the simplest EVHP mode, and all currently available clinical EVHP systems employ this perfusion method. In contrast, the working mode allows perfusate inflow from the left atrium, thereby generating preload and enabling cardiac output. In our experimental studies, the working mode demonstrated enhanced myocardial metabolism compared with the resting mode; however, it was also associated with increased energy consumption due to cardiac contraction. To address this issue, we developed a left ventricular assist device (LVAD) mode, in which cardiac contraction is supported by a LVAD pump operating in the working mode. LVAD mode was associated with significantly better cardiac function than the resting and working mode. The preservation of cardiac function during EVHP is considered to be greatly influenced by the perfusion mode. Further development of optimized modes will be essential for the effective preservation and evaluation of donor hearts in the future. This review was created based on a translation of the Japanese review written in the Japanese Journal of Artificial Organs in 2024 (Vol. 53, No. 3, pp. 210–215).


  • Open Access

    A Whole-body Cooling Strategy in Uncontrolled Donation After Circulatory Death: Insights From a Porcine Ex Vivo Lung Perfusion Model

    by Hiromichi Niikawa, Daisuke Sakota, Ryo Kosaka, Ichiro Sakanoue, Soumei Baba, Katsuhiro Ohuchi, Tetsuhito Kigata, Carol F. Farver, Kenneth R. McCurry, Yoshinori Okada, et al.

    Background.: Prolonged warm ischemia in uncontrolled donation after circulatory death (uDCD) potentially increases the risk of graft dysfunction in lung transplantation. To address this concern, a noninvasive, whole-body cooling approach was developed using a specialized liquid refrigerant at −21 °C. The aim of this study was to investigate whether this method reduces lung temperature and improves lung function in uDCD donors. Methods.: Fifteen pigs were randomly assigned to 3 groups. In the study group (n = 5), the entire donor body was submerged in a basin containing a coolant of −21 °C, and chest compression was performed during 90 min of warm ischemia. In the sham group (n = 5), neither body cooling nor chest compression was performed during 90 min of warm ischemia. Lungs were evaluated by cellular ex vivo lung perfusion (EVLP) after 5 h of additional cold ischemia. Lungs in the donation after brain death (DBD) group (n = 5) were perfused after 1 h of cold ischemia. Results.: Tracheal temperature decreased to 28.5 °C in the study group and remained at 38.1 °C in the sham group. Lungs in the study group showed higher transplant suitability with significantly higher PaO 2 /FiO 2 , and lower peak inspiratory pressure during EVLP than those in the sham group (all P < 0.05). The study group had a significantly higher ATP level, a relatively lower hypoxia-inducible factor-1α level, and lower percentage of apoptotic cells than the sham group. Conclusions.: This novel cooling approach effectively reduced lung temperature during warm ischemia, resulting in improved lung function during EVLP. These data suggest that this method could mitigate ischemia–reperfusion injury in uDCD donors, expanding the donor lung pool.


  • Open Access

    Left ventricular assist device mode: Co-pulse left ventricular unloading in a working mode of ex vivo heart perfusion

    by Daisuke Sakota, Ryo Kosaka, Eiki Nagaoka, Katsuhiro Ohuchi, Tomoki Tahara, Hirokuni Arai, Ichiro Sakanoue, Kenneth R. McCurry, Toshihiro Okamoto


  • Open Access

    Lung thermography during the initial reperfusion period to assess pulmonary function in cellular ex vivo lung perfusion

    by Ryo Kosaka, Daisuke Sakota, Hiromichi Niikawa, Katsuhiro Ohuchi, Hirokuni Arai, Kenneth R. McCurry, Toshihiro Okamoto

    Background: Thermography is a noninvasive technology to detect low temperatures in poorly circulated areas. In ex vivo lung perfusion (EVLP), lungs are rewarmed to body temperature during the initial 1 h. Currently, the effect of graft thermal changes during the rewarming phase on pulmonary function is unknown. In this study, we evaluated the correlation of lung surface temperature with physiological parameters, wet/dry ratio, and transplant suitability in Lund‐type EVLP.Methods: Fifteen pigs were divided into three groups: control group (no warm ischemia) or donation after circulatory death groups with 60 or 90 min of warm ischemia (n = 5, each). Thermal images of the lower lobes were continuously collected from the bottom of an organ chamber using infrared thermography throughout EVLP.Results: At 8 min, lung surface temperatures of nonsuitable cases were significantly lower than in suitable cases (25.1 ± 0.6 vs. 27.8 ± 1.2°C, p < 0.001), while there was no difference in lung surface temperatures between the two groups at 0–4 min and 12–120 min. There was a significant negative correlation between lung surface temperatures at 8 min and wet/dry ratio at 2 h in the lower lobes (R = −0.769, p < 0.001, cutoff = 26°C, area under the curve = 1.0). A lung surface temperature of <26°C was significantly correlated with poor pulmonary function and transplant nonsuitability.Conclusion: A lung surface temperature of ≥26°C at 8 min is a good early predictor of transplant suitability in cellular EVLP and might be applicable in clinical EVLP.


  • Impact of gap size and groove design of hydrodynamic bearing on plasma skimming effect for use in rotary blood pump

    by Ming Jiang, Daisuke Sakota, Ryo Kosaka, Wataru Hijikata

    Plasma skimming can exclude red blood cells from high shear regions in the gaps formed by hydrodynamic bearings in rotary blood pumps. We investigated the effect of the gap size and groove design on the plasma skimming efficiency. Spiral groove bearings (SGBs) were installed into a specially designed test rig for in vitro experiments performed using human blood. The measured gap between the ridges of the bearing and the rotor surface was 17–26 µm at a flow rate of 150 ml/min and a rotor speed of 2400 rpm. Three different patterns of SGBs were designed (SGB-0, SGB-30, and SGB-60) with various degrees of the circumferential component. The hematocrit measured by a high-speed camera was compared with the hematocrit in the circuit, and the plasma skimming efficiency for the three bearing patterns was evaluated at hematocrits of 20%, 25%, and 30%. SGB-60, which had the strongest circumferential component, provided the best plasma skimming efficiency. When the gap size was less than 20 µm, the red blood cells in the gaps between the ridges of the bearing and rotor surface reduced significantly and the efficiency became higher than 90%. The gap size had the strongest effect on producing a significant plasma skimming. The plasma skimming efficiency can be significantly improved by optimizing the bearing gap size and groove design, which facilitates the further development of SGBs for use in applications such as rotary blood pumps.


  • Individual Variability in von Willebrand Factor Fragility in Response to Shear Stress: A Possible Clue for Predicting Bleeding Risk

    by Ko Sakatsume, Masatoshi Akiyama, Daisuke Sakota, Wataru Hijikata, Hisanori Horiuchi, Osamu Maruyama, Yoshikatsu Saiki

    Acquired von Willebrand syndrome (AVWS), characterized by reduced von Willebrand factor (VWF) large multimers, has recently been implicated as the principal mechanism underlying bleeding in patients implanted with left ventricular assist devices (LVADs). Hematological severity of AVWS varies among patients, even if an identical device is implanted. We investigated whether this diversity in hematological severity is due to individual variability in VWF fragility, according to responses to incremental shear stress. Whole-blood samples were sheared at 20,000–40,000 s–1 shear rate, an index of shear stress, using a custom-made shear stressor that could generate shear stress compatible with that produced by an LVAD. The degree of VWF large multimers degradation was evaluated using the VWF large multimer index. A significant inverse correlation was observed between the VWF large multimer index and LVAD-compatible magnitudes of shear stress: the VWF large multimer indices were 68.5 ± 18.3, 48.0 ± 13.9, 33.9 ± 12.1, 23.7 ± 7.9, and 18.7% ± 8.7% at 20,000, 25,000, 30,000, 35,000, and 40,000 s–1 of shear rates, respectively (P < 0.0001). Furthermore, experimental VWF large multimer index values were compatible with those derived from patients with implanted LVADs (median; 28.9%). Finally, reduction in the VWF large multimer index corresponding to shear stress showed individual variation. We demonstrated that the combined use of a novel high shear stress loading device and quantitative evaluation of VWF large multimers may predict risk of bleeding before LVAD implantation.


  • Optical oxygen saturation imaging in cellular ex vivo lung perfusion to assess lobular pulmonary function

    by Daisuke Sakota, Ryo Kosaka, Hiromichi Niikawa, Katsuhiro Ohuchi, Hirokuni Arai, Kenneth R. McCurry, Toshihiro Okamoto

    Ex vivo lung perfusion (EVLP) is an emerging tool to evaluate marginal lungs in lung transplantation. However, there is no objective metric to monitor lobular regional oxygenation during EVLP. In this study, we developed oxygen saturation (SaO2) imaging to quantitatively assess the regional gas exchange potential of the lower lobes. Ten porcine lungs were randomly divided into control and donation after circulatory death (DCD) groups (n = 5, each). Lungs were perfused in cellular EVLP for 2 h, and multispectral images were continuously collected from the dorsal sides of the lower lobes. We examined whether lower lobe SaO2 correlated with PaO2/FiO2 (P/F) ratios in lower pulmonary veins (PV). The wet/dry ratio in lower lobes was measured and Monte Carlo simulations were performed to investigate the method’s feasibility. There was a significant correlation between lower lobe SaO2 and the P/F ratio in lower PV (r = 0.855, P < 0.001). The DCD group was associated with lower SaO2 and higher wet/dry ratio than the control group (P < 0.001). The error of estimated SaO2 was limited according to Monte Carlo simulations. The developed technology provides a noninvasive and regional evaluative tool of quantitative lobular function in EVLP.


  • In vitro hemocompatibility investigation for the development of low-flow centrifugal blood pumps with less platelet clogging

    by Akiko Oota-Ishigaki, Takashi Yamane, Daisuke Sakota, Ryo Kosaka, Osamu Maruyama, Masahiro Nishida

    Low-flow blood pumps rated under 1 L/min are emerging for new medical applications, such as hemofiltration in acute use. In those pumps, platelet adhesion and aggregation have to be carefully considered because of clogging risk in the filter part. To find an acceptable hemocompatibility that can be applied to low-flow centrifugal blood pump design, the platelet aggregation index, clogging on a micromesh filter, and the hemolysis index were investigated using a low-flow blood pump designed for hemofiltration use. We conducted circulation testing in vitro using fresh porcine blood and two centrifugal pumps with different impeller inlet shapes. The Negative Log Platelet Aggregation Threshold Index (NL-PATI), which reflects the ability of residual platelets to aggregate, and flow rate were measured during reflux for 60 min, and the Normalized Index of Hemolysis (NIH (g/20 min)) was calculated. In addition, blood cell clogging after reflux was observed on the micromesh filter by SEM, and the adhesion rate was calculated. Our results showed that the platelet clogging on the micromesh filter occurred when the average NL-PATI was greater than 0.28 and the average NIH (g/20 min) was greater than 0.01. In contrast, platelet clogging on the micromesh was suppressed when NL-PATI was less than 0.17 and the NIH (g/20 min) was less than 0.003. These values might be used as acceptable hemocompatibility of low-flow centrifugal blood pumps with suppressed platelet clogging for hemofiltration pumps.


  • Quantitative investigation of platelet aggregation under high shear force for anti-platelet aggregation in vitro tests

    by Akiko Oota-Ishigaki, Osamu Maruyama, Daisuke Sakota, Ryo Kosaka, Wataru Hijikata, Masahiro Nishida

    Blood pumps are often used for hemofiltration in patients with renal failure. To design effective centrifugal blood pumps for hemofiltration, it is important to suppress clogging caused by platelet aggregation. However, the optimal conditions for conducting anti-platelet aggregation tests in vitro have not yet been established. This study aimed to quantify the effect of the shear loading value and shear loading time on platelet aggregation and determine the optimal conditions for anti-platelet aggregation testing in vitro. To quantitatively evaluate platelet aggregation in terms of the negative logarithm-platelet aggregation threshold index (NL-PATI), which reflects the propensity of residual platelets to aggregate after shear loading, the following parameters were examined: blood collection method (collected from porcine vein using a syringe or collected from a slaughterhouse), type of anticoagulant (sodium citrate or heparin), shear rate, and shear time. The results showed that platelet aggregation in porcine blood increased under a high shear load applied at shear rates of approximately 20,000 s−1 or higher for 30 s. Platelet aggregation propensity was 2–3 times higher in heparin-anticoagulated blood than in sodium citrate-anticoagulated blood. Moreover, platelet aggregation was 1.5–2 times more in blood collected from the slaughterhouse than in syringe-collected blood. Testing with an integrated shear time of 30 s or less in relation to the total blood volume may be effective for conducting in vitro circulation experiments using hemofiltration blood pumps. The conditions established in this study may be useful for hemocompatibility testing of cardiovascular devices based on NL-PATI.


  • Open Access

    Real-time, non-invasive thrombus detection in an extracorporeal circuit using micro-optical thrombus sensors

    by Nobutomo Morita, Daisuke Sakota, Akiko Oota-Ishigaki, Ryo Kosaka, Osamu Maruyama, Masahiro Nishida, Kazuki Kondo, Toshihiro Takeshita, Wataru Iwasaki

    Introduction: Real-time, non-invasive monitoring of thrombus formation in extracorporeal circuits has yet to be achieved. To address the challenges of conventional optical thrombus detection methods requiring large devices that limit detection capacity, we developed a micro-optical thrombus sensor. Methods: The proposed micro-optical thrombus sensor can detect the intensity of light scattered by blood at wavelengths of 660 and 855 nm. Two thrombus sensors were installed on in vitro circuit: one at the rotary blood pump and one at a flow channel. To evaluate the variation in the ratio of incident light intensity at each wavelength of the two sensors, Rfluct (for 660 nm) and Ifluct (for 855 nm) were defined. Using fresh porcine blood as a working fluid, we performed in vitro tests of haematocrit (Hct) and oxygen saturation (SaO2) variation and thrombus detection. Thrombus tests were terminated after Rfluct or Ifluct showed a larger change than the maximum range of those in the Hct and SaO2 variation test. Results: In all three thrombus detection tests, Ifluct showed a larger change than the maximum range of those in the Hct and SaO2 variation test. After the tests, thrombus formation was confirmed in the pump, and there was no thrombus in the flow channel. The results indicate that Ifluct is an effective parameter for identifying the presence of a thrombus. Conclusion: Thrombus detection in an extracorporeal circuit using the developed micro-optical sensors was successfully demonstrated in an in vitro test.