Teng Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Teng Zhang has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- Haixing Miao
Tsinghua University
33 shared publications - D. V. Martynov
University of Birmingham
26 shared publications - Andrew Spencer
University of Glasgow
24 shared publications - Borja Sorazu
SUPA, University of Glasgow, Glasgow G12 8QQ, UK
23 shared publications - Bryan Barr
University of Glasgow
23 shared publications - Andreas Freise
NIKHEF
22 shared publications
Latest Publications
- 18 June 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 114 (6)
DC response of an interferometer topology with an L-shaped cavity: A tabletop study
- 18 June 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 114 (6)
DC response of an interferometer topology with an L-shaped cavity: A tabletop study
- Open Access
- 10 June 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 137 (3)
Extending ground-based gravitational-wave sensitivity to 5 Hz
Extending the sensitivity of terrestrial gravitational-wave detectors below 20 Hz is a long-standing challenge, limited by ground motion and inertial sensing noise. In this Letter, we demonstrate ultra-high-vacuum compatible inertial isolation and position sensing technologies that achieve active platform stabilization down to 10 mHz. Our laser position sensors reach a sub − pm / Hz sensitivity above 10 mHz, independent of the input light polarization, representing a 100-fold improvement over the current LIGO position sensors. In addition, our inertial sensors provide at least a factor of 5 improvement in low-frequency sensitivity compared to state-of-the-art commercial seismometers. We integrate these technologies into a LIGO-like interferometer model and predict a low-frequency sensitivity improvement of up to an order of magnitude at 10 Hz, with enhanced linearity and calibration stability. This extension increases the detection horizon for intermediate-mass black hole binaries of mass 10 3 M ⊙ by a factor of 3 and increases the SNR for all lower mass binaries. Our results provide the first experimental demonstration of a practical pathway to sub-10 Hz operation of terrestrial gravitational-wave detectors and establish key technologies for next-generation observatories such as Cosmic Explorer and Einstein Telescope.
- 10 June 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 137 (3)
Open AccessExtending ground-based gravitational-wave sensitivity to 5 Hz
Extending the sensitivity of terrestrial gravitational-wave detectors below 20 Hz is a long-standing challenge, limited by ground motion and inertial sensing noise. In this Letter, we demonstrate ultra-high-vacuum compatible inertial isolation and position sensing technologies that achieve active platform stabilization down to 10 mHz. Our laser position sensors reach a sub − pm / Hz sensitivity above 10 mHz, independent of the input light polarization, representing a 100-fold improvement over the current LIGO position sensors. In addition, our inertial sensors provide at least a factor of 5 improvement in low-frequency sensitivity compared to state-of-the-art commercial seismometers. We integrate these technologies into a LIGO-like interferometer model and predict a low-frequency sensitivity improvement of up to an order of magnitude at 10 Hz, with enhanced linearity and calibration stability. This extension increases the detection horizon for intermediate-mass black hole binaries of mass 10 3 M ⊙ by a factor of 3 and increases the SNR for all lower mass binaries. Our results provide the first experimental demonstration of a practical pathway to sub-10 Hz operation of terrestrial gravitational-wave detectors and establish key technologies for next-generation observatories such as Cosmic Explorer and Einstein Telescope.
- Open Access
- 23 October 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 112 (8)
Demonstrating the velocity response of a table-top EPR speedmeter
The sensitivity of gravitational wave interferometers is fundamentally limited by quantum noise, as dictated by the Heisenberg uncertainty principle, due to their continuous position measurement of the end mirrors. Speedmeter configurations, which measure mirror velocity rather than position, have been proposed as a means to suppress quantum backaction noise, but practical implementations remain at an early stage. In this work, we present a table-top realization of the Einstein-Podolsky-Rosen (EPR) speedmeter concept, employing an optical readout scheme based on two orthogonal polarization modes that probe the interferometer with different effective bandwidths. Using a triangular cavity, we demonstrate that the differential optical response between the linear p- and s-polarized modes exhibits a speedlike frequency dependence: vanishing at DC and increasing linearly with signal frequency, up to the bandwidth of the slower mode. With this we show that an optical system equivalent to the EPR speedmeter indeed performs a velocity readout of the end mirror.
- 23 October 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 112 (8)
Open AccessDemonstrating the velocity response of a table-top EPR speedmeter
The sensitivity of gravitational wave interferometers is fundamentally limited by quantum noise, as dictated by the Heisenberg uncertainty principle, due to their continuous position measurement of the end mirrors. Speedmeter configurations, which measure mirror velocity rather than position, have been proposed as a means to suppress quantum backaction noise, but practical implementations remain at an early stage. In this work, we present a table-top realization of the Einstein-Podolsky-Rosen (EPR) speedmeter concept, employing an optical readout scheme based on two orthogonal polarization modes that probe the interferometer with different effective bandwidths. Using a triangular cavity, we demonstrate that the differential optical response between the linear p- and s-polarized modes exhibits a speedlike frequency dependence: vanishing at DC and increasing linearly with signal frequency, up to the bandwidth of the slower mode. With this we show that an optical system equivalent to the EPR speedmeter indeed performs a velocity readout of the end mirror.
- Open Access
- 4 May 2025
- Published by Elsevier in Physics Letters A
- Vol. 550
Optical torques in the folding Fabry–Perot cavity
- 4 May 2025
- Published by Elsevier in Physics Letters A
- Vol. 550
Open AccessOptical torques in the folding Fabry–Perot cavity
- 30 April 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 111 (8)
Merging the L-shaped resonator with Michelson configuration for kilohertz gravitational-wave detection
- 30 April 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 111 (8)
Merging the L-shaped resonator with Michelson configuration for kilohertz gravitational-wave detection
- Open Access
- 15 October 2024
- Published by American Physical Society (APS) in Physical Review D
- Vol. 110 (8)
Approaches of frequency-dependent squeezing for the low frequency detector of the Einstein Telescope
The quantum noise in gravitational-wave detectors can be suppressed in a broadband by frequency-dependent squeezing. It usually requires one large scale filter cavity and even two, for example in the low frequency detector of Einstein Telescope, which is a detuned dual recycling Fabry-Perot Michelson interferometer. In this paper, we study the feasibility of replacing two filter cavities with a coupled-cavity, aiming to reduce the optical losses with less number of optics. It turns out this approach is only theoretically valid, however, the required parameters of the optics do not support practical implementation, which is consistent with the results in Jones [Implications of the quantum noise target for the Einstein Telescope infrastructure design, ]. Furthermore, we investigate the viability of utilizing Einstein-Podolsky-Rosen (EPR) squeezing to eliminate either one or two filter cavities in the Einstein Telescope. It turns out EPR squeezing would allow us to eliminate one filter cavity, and can potentially improve the detector sensitivity with the allowance of higher input squeezing level, benefiting from the longer length of the arm cavity which serves as one of the filter cavities for frequency-dependent squeezing. Published by the American Physical Society 2024
- 15 October 2024
- Published by American Physical Society (APS) in Physical Review D
- Vol. 110 (8)
Open AccessApproaches of frequency-dependent squeezing for the low frequency detector of the Einstein Telescope
The quantum noise in gravitational-wave detectors can be suppressed in a broadband by frequency-dependent squeezing. It usually requires one large scale filter cavity and even two, for example in the low frequency detector of Einstein Telescope, which is a detuned dual recycling Fabry-Perot Michelson interferometer. In this paper, we study the feasibility of replacing two filter cavities with a coupled-cavity, aiming to reduce the optical losses with less number of optics. It turns out this approach is only theoretically valid, however, the required parameters of the optics do not support practical implementation, which is consistent with the results in Jones [Implications of the quantum noise target for the Einstein Telescope infrastructure design, ]. Furthermore, we investigate the viability of utilizing Einstein-Podolsky-Rosen (EPR) squeezing to eliminate either one or two filter cavities in the Einstein Telescope. It turns out EPR squeezing would allow us to eliminate one filter cavity, and can potentially improve the detector sensitivity with the allowance of higher input squeezing level, benefiting from the longer length of the arm cavity which serves as one of the filter cavities for frequency-dependent squeezing. Published by the American Physical Society 2024
- 1 August 2024
- Published by American Physical Society (APS) in Physical Review A
- Vol. 110 (2) , 022601
Frequency-dependent squeezing for gravitational-wave detection through quantum teleportation
Ground-based interferometric gravitational-wave detectors are highly precise sensors for weak forces, limited in sensitivity across their detection band by quantum fluctuations of light. Current and future instruments address this limitation by injecting frequency-dependent squeezed vacuum into the detection port, utilizing narrow-band, low-loss optical filter cavities for optimal rotation of the squeezing ellipse at each signal frequency. This study introduces a scheme of such vacuum injection employing the principles of quantum teleportation which works the same as an arbitrary number of filter cavities without additional kilometer-scale infrastructure. We applied this scheme to a detuned signal-recycled Fabry-Pérot–Michelson interferometer, which is the baseline design of the low-frequency detector within the Einstein Telescope xylophone detector. It is shown that our scheme achieves broadband suppression of quantum noise without requiring additional filter cavities or modifications to the core optics of the main interferometer.
- 1 August 2024
- Published by American Physical Society (APS) in Physical Review A
- Vol. 110 (2) , 022601
Frequency-dependent squeezing for gravitational-wave detection through quantum teleportation
Ground-based interferometric gravitational-wave detectors are highly precise sensors for weak forces, limited in sensitivity across their detection band by quantum fluctuations of light. Current and future instruments address this limitation by injecting frequency-dependent squeezed vacuum into the detection port, utilizing narrow-band, low-loss optical filter cavities for optimal rotation of the squeezing ellipse at each signal frequency. This study introduces a scheme of such vacuum injection employing the principles of quantum teleportation which works the same as an arbitrary number of filter cavities without additional kilometer-scale infrastructure. We applied this scheme to a detuned signal-recycled Fabry-Pérot–Michelson interferometer, which is the baseline design of the low-frequency detector within the Einstein Telescope xylophone detector. It is shown that our scheme achieves broadband suppression of quantum noise without requiring additional filter cavities or modifications to the core optics of the main interferometer.
- Open Access
Approaches of frequency-dependent squeezing for the low frequency detector of Einstein Telescope
The quantum noise in gravitational-wave detectors can be suppressed in a broadband by frequency-dependent squeezing. It usually requires one large scale filter cavity and even two, for example in the low frequency detector of Einstein Telescope, which is a detuned dual recycling Fabry-Perot Michelson interferometer. In this paper, we study the feasibility of replacing two filter cavities with a coupled-cavity, aiming to reduce the optical losses with less number of optics. It turns out this approach is only theoretically valid, however, the required parameters of the optics don't support practical implementation, which is consistent with the results in [Phys. Rev. D {\bf 101}, 082002 (2020)]. Furthermore, we investigate the viability of utilizing EPR squeezing to eliminate either one or two filter cavities in Einstein Telescope. It turns out EPR squeezing would allow to eliminate one filter cavity, and can potentially improve the detector sensitivity with the allowance of higher input squeezing level, benefiting from the longer length of the arm cavity which serves as one of the filter cavities for frequency-dependent squeezing.
Open AccessApproaches of frequency-dependent squeezing for the low frequency detector of Einstein Telescope
The quantum noise in gravitational-wave detectors can be suppressed in a broadband by frequency-dependent squeezing. It usually requires one large scale filter cavity and even two, for example in the low frequency detector of Einstein Telescope, which is a detuned dual recycling Fabry-Perot Michelson interferometer. In this paper, we study the feasibility of replacing two filter cavities with a coupled-cavity, aiming to reduce the optical losses with less number of optics. It turns out this approach is only theoretically valid, however, the required parameters of the optics don't support practical implementation, which is consistent with the results in [Phys. Rev. D {\bf 101}, 082002 (2020)]. Furthermore, we investigate the viability of utilizing EPR squeezing to eliminate either one or two filter cavities in Einstein Telescope. It turns out EPR squeezing would allow to eliminate one filter cavity, and can potentially improve the detector sensitivity with the allowance of higher input squeezing level, benefiting from the longer length of the arm cavity which serves as one of the filter cavities for frequency-dependent squeezing.
- Open Access
- 7 February 2024
- Published by Springer Nature in Research Square
Frequency-dependent squeezing for gravitational-wave detection through quantum teleportation
Ground-based interferometric gravitational wave detectors are highly precise sensors for weak forces, limited in sensitivity across their detection band by quantum fluctuations of light. Current and future instruments address this limitation by injecting frequency-dependent squeezed vacuum into the detection port, utilizing narrow-band, low-loss optical cavities for optimal rotation of the squeezing ellipse at each signal frequency. This study introduces a novel scheme employing the principles of quantum teleportation and entangled states of light. It allows achieving broadband suppression of quantum noise in detuned signal recycled-Fabry-Perot--Michelson interferometers, which is the baseline design of the low-frequency detector within the Einstein Telescope xylophone detector, without requiring additional filter cavities or modifications to the core optics of the main interferometer.
- 7 February 2024
- Published by Springer Nature in Research Square
Open AccessFrequency-dependent squeezing for gravitational-wave detection through quantum teleportation
Ground-based interferometric gravitational wave detectors are highly precise sensors for weak forces, limited in sensitivity across their detection band by quantum fluctuations of light. Current and future instruments address this limitation by injecting frequency-dependent squeezed vacuum into the detection port, utilizing narrow-band, low-loss optical cavities for optimal rotation of the squeezing ellipse at each signal frequency. This study introduces a novel scheme employing the principles of quantum teleportation and entangled states of light. It allows achieving broadband suppression of quantum noise in detuned signal recycled-Fabry-Perot--Michelson interferometers, which is the baseline design of the low-frequency detector within the Einstein Telescope xylophone detector, without requiring additional filter cavities or modifications to the core optics of the main interferometer.
- Open Access
Sensing and control scheme for the inteferometer configuration with an L-shaped resonator
The detection of high-frequency gravitational waves around kHz is critical to understanding the physics of binary neutron star mergers. A new interferometer design has been proposed in [Phys. Rev. X {\bf 13}, 021019 (2023)], featuring an L-shaped optical resonator as the arm cavity, which resonantly enhances kHz gravitational-wave signals. This new configuration has the potential to achieve better high-frequency sensitivity than the dual-recycled Fabry-Perot Michelson. In this article, we propose a sensing and control scheme for this configuration. Despite having the same number of length degrees of freedom as the dual-recycled Fabry-Perot Michelson, the new configuration requires one less degree of freedom to be controlled due to the degeneracy of two length degrees of freedom at low frequencies. We has also shown that introducing the Schnupp asymmetry is ineffective for controlling the signal-recycling cavity length. Therefore, we propose adding control fields from the dark port to control this auxiliary degree of freedom.
Open AccessSensing and control scheme for the inteferometer configuration with an L-shaped resonator
The detection of high-frequency gravitational waves around kHz is critical to understanding the physics of binary neutron star mergers. A new interferometer design has been proposed in [Phys. Rev. X {\bf 13}, 021019 (2023)], featuring an L-shaped optical resonator as the arm cavity, which resonantly enhances kHz gravitational-wave signals. This new configuration has the potential to achieve better high-frequency sensitivity than the dual-recycled Fabry-Perot Michelson. In this article, we propose a sensing and control scheme for this configuration. Despite having the same number of length degrees of freedom as the dual-recycled Fabry-Perot Michelson, the new configuration requires one less degree of freedom to be controlled due to the degeneracy of two length degrees of freedom at low frequencies. We has also shown that introducing the Schnupp asymmetry is ineffective for controlling the signal-recycling cavity length. Therefore, we propose adding control fields from the dark port to control this auxiliary degree of freedom.