Mohd Ikhwan Muhammad Ridzuan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mohd Ikhwan Muhammad Ridzuan has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Nur Nabihah Rusyda Roslan
4 shared publicationsAhmad Zairi Mohd Zain
Faculty of Electrical and Electronics Engineering Technology Universiti Malaysia Pahang Al-Sultan Abdullah 26600 Pekan Pahang Malaysia
3 shared publicationsNoorFatin Farhanie Mohd Fauzi
Universiti Malaysia Pahang
3 shared publications- NoorFatin Farhanie Mohd Fauzi
Universiti Malaysia Pahang
3 shared publications - Nur Nabihah Rusyda Roslan
Universiti Malaysia Pahang
3 shared publications Norhafidzah Mohd Saad
2 shared publications
Latest Publications
- Open Access
- 30 January 2026
- Published by Penerbit Universiti Malaysia Perlis in Journal of Engineering Research and Education (JERE)
- Vol. 17, 140-153
Determined the Worst Served Customer using Regulatory-based Monte Carlo Simulation
Electric utilities typically present their network performance regarding System AverageInterruption Frequency Index (SAIFI), System Average Interruption Duration Index (SAIDI),and Customer Average Interruption Duration Index (CAIDI) indices. These indices are meanvalues for the fictitious types of customers. The report presents No values for the best,average, and worst types of customers. Normally, the best customer should have a highperformancevalue, while the worst customer should have a low-performance value.However, with the performance standards introduced by the energy regulator, theclassification of best- and worst-served customers (WSC) should differ. Energy regulators inmost countries regulate the electricity customers' minimum standard performance in termsof the number of interruptions and duration of the interruptions. These requirements areto protect customers from experiencing excessive interruption and duration. The methodused to assess customer performance is Monte Carlo simulation, which incorporatesperformance standard limits. The network used in this simulation is an IEEE 30 bus, and theoutput of the simulation is the number of interruptions and duration of interruption for eachcustomer in the network. The WSC is the customer that able to refined both it lowed its owninterruption and duration of interruption specifically and improved SAIFI/CAIDI of networkperformance generally. Plus, the electric utility company may pay fewer penalties if WSC isserved better.
- 30 January 2026
- Published by Penerbit Universiti Malaysia Perlis in Journal of Engineering Research and Education (JERE)
- Vol. 17, 140-153
Open AccessDetermined the Worst Served Customer using Regulatory-based Monte Carlo Simulation
Electric utilities typically present their network performance regarding System AverageInterruption Frequency Index (SAIFI), System Average Interruption Duration Index (SAIDI),and Customer Average Interruption Duration Index (CAIDI) indices. These indices are meanvalues for the fictitious types of customers. The report presents No values for the best,average, and worst types of customers. Normally, the best customer should have a highperformancevalue, while the worst customer should have a low-performance value.However, with the performance standards introduced by the energy regulator, theclassification of best- and worst-served customers (WSC) should differ. Energy regulators inmost countries regulate the electricity customers' minimum standard performance in termsof the number of interruptions and duration of the interruptions. These requirements areto protect customers from experiencing excessive interruption and duration. The methodused to assess customer performance is Monte Carlo simulation, which incorporatesperformance standard limits. The network used in this simulation is an IEEE 30 bus, and theoutput of the simulation is the number of interruptions and duration of interruption for eachcustomer in the network. The WSC is the customer that able to refined both it lowed its owninterruption and duration of interruption specifically and improved SAIFI/CAIDI of networkperformance generally. Plus, the electric utility company may pay fewer penalties if WSC isserved better.
- Open Access
- 12 December 2025
- Published by Elsevier in Cleaner Engineering and Technology
- Vol. 30
Fault Rates Alpha-Tolerance of Monte Carlo Simulation (FRAT-MCS) for Reliability Performance of Power System Network
- 12 December 2025
- Published by Elsevier in Cleaner Engineering and Technology
- Vol. 30
Open AccessFault Rates Alpha-Tolerance of Monte Carlo Simulation (FRAT-MCS) for Reliability Performance of Power System Network
- 2 October 2024
- Published by Springer Nature
- p. 483-496
Reliability Assessments of Distributed Generation Penetration Level on Power System Networks
- 2 October 2024
- Published by Springer Nature
- p. 483-496
Reliability Assessments of Distributed Generation Penetration Level on Power System Networks
- Open Access
- 1 June 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (3) , 1267-1275
Widespread compact fluorescent lamp evaluations in 50 Hz electrical network
Rapid development in electrical technology has imposed strong challenges to modern power system. Power quality has become a great concern due to proliferation of power electronic technology in modern electrical loads. Specifically for lighting load such as compact fluorescent lamps (CFLs), one of the concerning issues is harmonics. CFL is a cost-competitive and energy efficient compared to incandescent lamp. Inevitably, CFL produces harmonics current due to nonlinearity behaviour of the electronic ballast circuit. This paper presents a study on the widespread installation of CFL lamps in electrical power network. Initially, the harmonic current characteristics of local-branded CFL was identified from laboratory measurement. Then, a simulated CFL model was developed in MATLAB/Simulink to replicate the identified characteristics. The same step was repeated for other two different brands where eventually all models were embedded into a distribution network. The results show that at low voltage level, with installation more than 50 units for each type of CFL, the harmonic voltage distortion exceeded the 8% total harmonic distortion (THD) limit as stipulated in EN50160 standard. However, at higher voltage, the amount of THD decreased to average 0.94% and further down to average 0.28% at small transmission voltage level.
- 1 June 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (3) , 1267-1275
Open AccessWidespread compact fluorescent lamp evaluations in 50 Hz electrical network
Rapid development in electrical technology has imposed strong challenges to modern power system. Power quality has become a great concern due to proliferation of power electronic technology in modern electrical loads. Specifically for lighting load such as compact fluorescent lamps (CFLs), one of the concerning issues is harmonics. CFL is a cost-competitive and energy efficient compared to incandescent lamp. Inevitably, CFL produces harmonics current due to nonlinearity behaviour of the electronic ballast circuit. This paper presents a study on the widespread installation of CFL lamps in electrical power network. Initially, the harmonic current characteristics of local-branded CFL was identified from laboratory measurement. Then, a simulated CFL model was developed in MATLAB/Simulink to replicate the identified characteristics. The same step was repeated for other two different brands where eventually all models were embedded into a distribution network. The results show that at low voltage level, with installation more than 50 units for each type of CFL, the harmonic voltage distortion exceeded the 8% total harmonic distortion (THD) limit as stipulated in EN50160 standard. However, at higher voltage, the amount of THD decreased to average 0.94% and further down to average 0.28% at small transmission voltage level.
- Open Access
- 1 April 2023
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 13 (2) , 2316-2325
Reliability performance of distribution network by various probability distribution functions
Electricity is one of the essential sources for the daily basis activities. The continuous electricity supplied to the customers is one of the main goals for electricity provider. Reliability is one of the main aspects that is focused more on the planning of the power system especially in distribution network. The performance of reliability in the system is evaluated with three main reliability indices: system average interruption frequency index, system average interruption duration index, and customer average interruption duration index. These indices will only give information about the overall condition of the power system without showing the details about the specific of the consumers such as the amount interruptions experienced by customer in the system. In this paper, probability distribution function (PDF) observing the behavior of the components in the system is used in the reliability analysis. Weibull distribution, also known as Weibull family, is one of the most common PDF used in reliability analysis. As Weibull distribution is also related to several distributions, such as exponential and Rayleigh, these types of distributions are applied in the output reliability analysis to observe the performance of reliability in the system. IEEE 9-bus is used as distribution network and carried out using Monte-Carlo simulation.
- 1 April 2023
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 13 (2) , 2316-2325
Open AccessReliability performance of distribution network by various probability distribution functions
Electricity is one of the essential sources for the daily basis activities. The continuous electricity supplied to the customers is one of the main goals for electricity provider. Reliability is one of the main aspects that is focused more on the planning of the power system especially in distribution network. The performance of reliability in the system is evaluated with three main reliability indices: system average interruption frequency index, system average interruption duration index, and customer average interruption duration index. These indices will only give information about the overall condition of the power system without showing the details about the specific of the consumers such as the amount interruptions experienced by customer in the system. In this paper, probability distribution function (PDF) observing the behavior of the components in the system is used in the reliability analysis. Weibull distribution, also known as Weibull family, is one of the most common PDF used in reliability analysis. As Weibull distribution is also related to several distributions, such as exponential and Rayleigh, these types of distributions are applied in the output reliability analysis to observe the performance of reliability in the system. IEEE 9-bus is used as distribution network and carried out using Monte-Carlo simulation.
- Open Access
- 1 December 2022
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 11 (6) , 3061-3068
Variance reduction technique in reliability evaluation for distribution system by using sequential Monte Carlo simulation
This paper discusses the need for variance reduction in simulations in order to reduce the time required to compute a simulation. The large and complex network is commonly evaluated using a large-scale Monte Carlo simulation. Unfortunately, due to the different sizes of the network, it takes some time to complete a simulation. However, variance reduction techniques (VRT) can help to solve the issues. The effect of VRT changes the behaviors of a simulation, particularly the time required to run the simulation. To evaluate the reliability indices, two sequential Monte Carlo (SMC) methods are used. SMC with VRT and SMC without VRT are the two options. The presence of VRT in the simulation distinguishes the two simulations. Finally, reliability indices: system average interruption frequency index (SAIFI), system average interruption duration index (SAIDI), and customer average interruption duration index (CAIDI) will be calculated at the end of the simulation to determine the efficiency for the SMC with and without VRT. Overall, the SMC with VRT is more efficient because it is more convenient and saves time than the SMC without VRT.
- 1 December 2022
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 11 (6) , 3061-3068
Open AccessVariance reduction technique in reliability evaluation for distribution system by using sequential Monte Carlo simulation
This paper discusses the need for variance reduction in simulations in order to reduce the time required to compute a simulation. The large and complex network is commonly evaluated using a large-scale Monte Carlo simulation. Unfortunately, due to the different sizes of the network, it takes some time to complete a simulation. However, variance reduction techniques (VRT) can help to solve the issues. The effect of VRT changes the behaviors of a simulation, particularly the time required to run the simulation. To evaluate the reliability indices, two sequential Monte Carlo (SMC) methods are used. SMC with VRT and SMC without VRT are the two options. The presence of VRT in the simulation distinguishes the two simulations. Finally, reliability indices: system average interruption frequency index (SAIFI), system average interruption duration index (SAIDI), and customer average interruption duration index (CAIDI) will be calculated at the end of the simulation to determine the efficiency for the SMC with and without VRT. Overall, the SMC with VRT is more efficient because it is more convenient and saves time than the SMC without VRT.
- Open Access
- 1 December 2022
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 12 (6) , 6218-6227
Monte Carlo simulation convergences’ percentage and position in future reliability evaluation
Reliability assessment is a needed assessment in today's world. It is required not only for system design but also to ensure the power delivered reaches the consumer. It is usual for fault to occur, but it is best if the fault can be predicted and the way to overcome it can be prepared in advance. Monte Carlo simulation is a standard method of assessing reliability since it is a time-based evaluation that nearly represents the actual situation. However, sequential Monte Carlo (SMC) typically took long-time simulation. A convergence element can be implemented into the simulation to ensure that the time taken to compute the simulation can be reduced. The SMC can be done with and without convergence. SMC with convergence has high accuracy compared to the SMC without convergence, as it takes a long time and has a high possibility of not getting accurate output. In this research, the SMC is subjected to five different convergence items to determine which converge simulation is the fastest while providing better performance for reliability evaluation. There are two types of convergence positions, namely input convergence and output convergence. Overall, output convergence shows the best result compared to input convergence.
- 1 December 2022
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 12 (6) , 6218-6227
Open AccessMonte Carlo simulation convergences’ percentage and position in future reliability evaluation
Reliability assessment is a needed assessment in today's world. It is required not only for system design but also to ensure the power delivered reaches the consumer. It is usual for fault to occur, but it is best if the fault can be predicted and the way to overcome it can be prepared in advance. Monte Carlo simulation is a standard method of assessing reliability since it is a time-based evaluation that nearly represents the actual situation. However, sequential Monte Carlo (SMC) typically took long-time simulation. A convergence element can be implemented into the simulation to ensure that the time taken to compute the simulation can be reduced. The SMC can be done with and without convergence. SMC with convergence has high accuracy compared to the SMC without convergence, as it takes a long time and has a high possibility of not getting accurate output. In this research, the SMC is subjected to five different convergence items to determine which converge simulation is the fastest while providing better performance for reliability evaluation. There are two types of convergence positions, namely input convergence and output convergence. Overall, output convergence shows the best result compared to input convergence.
- Open Access
- 1 May 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 863 (1) , 012042
Low voltage reliability equivalent using monte-carlo simulation technique
Reliability is the ability of a system to supply continuous electricity to customer which ends with zero fault that occurs under a specific period of time. Most of the literature focus more on medium voltage (MV) and high voltage (HV) compared to the low voltage (LV) due to the general absence of exact data in LV network and sizing of LV network. In addition, an increament in size of the LV network makes the network more complex and difficult to assess. Therefore, in this paper, the performance of reliability in LV network will be evaluated in detailed network model. To reduce simulation time, methodology of reducing detailed network into an equivalent network is introduced. This equivalent network is obtained by simplifying the complex network using Monte-Carlo Simulation technique. The results in this research are quantified and compared between these detailed and equivalent networks in reliability indices; SAIFI, SAIDI and CAIDI. The values of SAIFI, SAIDI and CAIDI in detailed network are slightly higher than in equivalent network.
- 1 May 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 863 (1) , 012042
Open AccessLow voltage reliability equivalent using monte-carlo simulation technique
Reliability is the ability of a system to supply continuous electricity to customer which ends with zero fault that occurs under a specific period of time. Most of the literature focus more on medium voltage (MV) and high voltage (HV) compared to the low voltage (LV) due to the general absence of exact data in LV network and sizing of LV network. In addition, an increament in size of the LV network makes the network more complex and difficult to assess. Therefore, in this paper, the performance of reliability in LV network will be evaluated in detailed network model. To reduce simulation time, methodology of reducing detailed network into an equivalent network is introduced. This equivalent network is obtained by simplifying the complex network using Monte-Carlo Simulation technique. The results in this research are quantified and compared between these detailed and equivalent networks in reliability indices; SAIFI, SAIDI and CAIDI. The values of SAIFI, SAIDI and CAIDI in detailed network are slightly higher than in equivalent network.
- 24 March 2020
- Published by Springer Nature
- p. 783-793
Reliability Performance of Low Voltage (LV) Network Configuration
- 24 March 2020
- Published by Springer Nature
- p. 783-793
Reliability Performance of Low Voltage (LV) Network Configuration