Eduardo Maia Paiva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Eduardo Maia Paiva has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Claudete Fernandes Pereira
Department of Fundamental Chemistry, Federal University of Pernambuco, Avenida Jornalista Aníbal Fernandes, Recife, PE CEP: 50740-560, Brazil
3 shared publicationsJarbas José Rodrigues Rohwedder
Institute of Chemistry, State University of Campinas - Unicamp, Rua Monteiro Lobato, 290, Campinas, SP CEP: 13083-862, Brazil
3 shared publications- Celio Pasquini
Institute of Chemistry, State University of Campinas, Rua Monteiro Lobato, 290, 13083-862, Campinas, SP, Brazil
2 shared publications - Claudete Fernandes Pereira
Federal University of Pernambuco (UFPE), Department of Fundamental Chemistry, Recife, PE, Brazil
2 shared publications - Florian Manfred Schmidt
Thermochemical Energy Conversion Laboratory, Department of Applied Physics and Electronics, Umeå University, SE-90187Umeå, Sweden
2 shared publications - Jarbas José Rodrigues Rohwedder
Institute of Chemistry, State University of Campinas-Unicamp, Rua Monteiro Lobato, 290, Campinas 13083-862, SP, Brazil
2 shared publications
Latest Publications
- Open Access
- 30 December 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (2) , 1140-1148
Quantitative Tomographic Laser Absorption Imaging of Atomic Potassium during Combustion of Potassium Chloride Salt and Biomass
- 30 December 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (2) , 1140-1148
Open AccessQuantitative Tomographic Laser Absorption Imaging of Atomic Potassium during Combustion of Potassium Chloride Salt and Biomass
- Open Access
- 5 October 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (41) , 14242-14250
Ultrafast Widefield Mid-Infrared Photothermal Heterodyne Imaging
Mid-infrared photothermal (MIP) microscopy is a valuable tool for sensitive and fast chemical imaging with high spatial resolution beyond the mid-infrared diffraction limit. The highest sensitivity is usually achieved with heterodyne MIP employing photodetector point-scans and lock-in detection, while the fastest systems use camera-based widefield MIP with pulsed probe light. One challenge is to simultaneously achieve high sensitivity, spatial resolution, and speed in a large field of view. Here, we present widefield mid-infrared photothermal heterodyne (WIPH) imaging, where a digital frequency-domain lock-in (DFdLi) filter is used for simultaneous multiharmonic demodulation of MIP signals recorded by individual camera pixels at frame rates up to 200 kHz. The DFdLi filter enables the use of continuous-wave probe light, which, in turn, eliminates the need for synchronization schemes and allows measuring MIP decay curves. The WIPH approach is characterized by imaging potassium ferricyanide microparticles and applied to detect lipid droplets (alkyne-palmitic acid) in 3T3-L1 fibroblast cells, both in the cell-silent spectral region around 2100 cm-1 using an external-cavity quantum cascade laser. The system achieved up to 4000 WIPH images per second at a signal-to-noise ratio of 5.52 and 1 μm spatial resolution in a 128 × 128 μm field of view. The technique opens up for real-time chemical imaging of fast processes in biology, medicine, and material science.
- 5 October 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (41) , 14242-14250
Open AccessUltrafast Widefield Mid-Infrared Photothermal Heterodyne Imaging
Mid-infrared photothermal (MIP) microscopy is a valuable tool for sensitive and fast chemical imaging with high spatial resolution beyond the mid-infrared diffraction limit. The highest sensitivity is usually achieved with heterodyne MIP employing photodetector point-scans and lock-in detection, while the fastest systems use camera-based widefield MIP with pulsed probe light. One challenge is to simultaneously achieve high sensitivity, spatial resolution, and speed in a large field of view. Here, we present widefield mid-infrared photothermal heterodyne (WIPH) imaging, where a digital frequency-domain lock-in (DFdLi) filter is used for simultaneous multiharmonic demodulation of MIP signals recorded by individual camera pixels at frame rates up to 200 kHz. The DFdLi filter enables the use of continuous-wave probe light, which, in turn, eliminates the need for synchronization schemes and allows measuring MIP decay curves. The WIPH approach is characterized by imaging potassium ferricyanide microparticles and applied to detect lipid droplets (alkyne-palmitic acid) in 3T3-L1 fibroblast cells, both in the cell-silent spectral region around 2100 cm-1 using an external-cavity quantum cascade laser. The system achieved up to 4000 WIPH images per second at a signal-to-noise ratio of 5.52 and 1 μm spatial resolution in a 128 × 128 μm field of view. The technique opens up for real-time chemical imaging of fast processes in biology, medicine, and material science.
- Open Access
- 24 August 2021
- Published by American Chemical Society (ACS) in Molecular Pharmaceutics
- Vol. 18 (9) , 3578-3587
Understanding the Metastability of Theophylline FIII by Means of Low-Frequency Vibrational Spectroscopy
While theophylline has been extensively studied with multiple polymorphs discovered, there is still currently no conclusive structure for the metastable theophylline form III. In this present work, by combining more widely used techniques such as X-ray diffraction and thermogravimetric analysis with more emerging techniques like low-frequency Raman and terahertz time-domain spectroscopy, to analyze the structure and dynamics of a crystalline system, it was possible to provide further evidence that the form III structure has a theophylline monohydrate structure with the water molecules removed. Solid-state density functional theory simulations were paramount in proving that this proposed structure is correct and explain how vibrational modes within the crystal structures feature and govern polymorphic transitions and the metastable form III. Through the insight provided by both simulated and experimental results, it was possible to decisively conclude the elusive crystal structure of theophylline form III. It was also shown that the correct space group for theophylline monohydrate is not P21/n but, in fact, Pc.
- 24 August 2021
- Published by American Chemical Society (ACS) in Molecular Pharmaceutics
- Vol. 18 (9) , 3578-3587
Open AccessUnderstanding the Metastability of Theophylline FIII by Means of Low-Frequency Vibrational Spectroscopy
While theophylline has been extensively studied with multiple polymorphs discovered, there is still currently no conclusive structure for the metastable theophylline form III. In this present work, by combining more widely used techniques such as X-ray diffraction and thermogravimetric analysis with more emerging techniques like low-frequency Raman and terahertz time-domain spectroscopy, to analyze the structure and dynamics of a crystalline system, it was possible to provide further evidence that the form III structure has a theophylline monohydrate structure with the water molecules removed. Solid-state density functional theory simulations were paramount in proving that this proposed structure is correct and explain how vibrational modes within the crystal structures feature and govern polymorphic transitions and the metastable form III. Through the insight provided by both simulated and experimental results, it was possible to decisively conclude the elusive crystal structure of theophylline form III. It was also shown that the correct space group for theophylline monohydrate is not P21/n but, in fact, Pc.
- 12 February 2021
- Published by Wiley in International Endodontic Journal
- Vol. 54 (7) , 1175-1188
Heating stability, physical and chemical analysis of calcium silicate‐based endodontic sealers
Aim: To evaluate possible modifications in root canal sealers subjected to a variety of heating conditions using vibrational spectroscopy and analysis of physical and chemical properties.Methodology: EndoSequence BC Sealer HiFlow, Bio‐C Sealer, BioRoot RCS and AH Plus were analysed chemically using Raman spectroscopy (25–220 °C) and Fourier‐transform infrared spectroscopy (FT‐IR) (37–100 °C ). For FT‐IR, the materials were tested individually and mixed with root dentine powder. Scanning electron microscopy (SEM) and coupled energy dispersive spectroscopy (EDS) were used to evaluate surface and chemical elements. ISO 6876‐2012 and ASTM‐C266‐07 specifications were followed to evaluate flow, setting time (moist and dry), solubility and radiopacity. Also, pH analysis at 37 and 100 °C was performed. Shapiro–Wilk and Mixed ANOVA (within and between the effects of the subjects), Levene, and a post hoc analyses with Bonferroni correction were performed (P < 0.05).Results: Vibrational spectroscopy revealed peaks of tricalcium silicate, dicalcium silicate and zirconium dioxide. Chemical changes in the Raman spectra during heating were discrete, as the inorganic content predominated the signalling for all root canal sealers. FT‐IR analysis exhibited spectral changes in water absorption for EndoSequence BC Sealer HiFlow and Bio‐C Sealer, probably related to dehydration. For BioRoot RCS and AH Plus, no significant chemical changes were observed. Bio‐C Sealer exhibited a band of polyethylene glycol only after heating to 100 °C, probably related to its thermal decomposition. SEM/EDS analysis corroborated the composition results observed in vibrational spectroscopy for all materials. Heating to 100 °C significantly changed the flowability of all calcium silicate‐based sealers with a wide variation in setting times at both temperatures, along with solubility levels above ISO standards. For all tested sealers, radiopacity fulfilled the requirements, and pH exhibited alkaline values.Conclusions: The tested calcium silicate‐based sealers were affected by heating. Calcium silicate‐based root canal sealers had high solubility which is a concern for their clinical use. AH Plus was the only root canal sealer that was stable after heating.
- 12 February 2021
- Published by Wiley in International Endodontic Journal
- Vol. 54 (7) , 1175-1188
Heating stability, physical and chemical analysis of calcium silicate‐based endodontic sealers
Aim: To evaluate possible modifications in root canal sealers subjected to a variety of heating conditions using vibrational spectroscopy and analysis of physical and chemical properties.Methodology: EndoSequence BC Sealer HiFlow, Bio‐C Sealer, BioRoot RCS and AH Plus were analysed chemically using Raman spectroscopy (25–220 °C) and Fourier‐transform infrared spectroscopy (FT‐IR) (37–100 °C ). For FT‐IR, the materials were tested individually and mixed with root dentine powder. Scanning electron microscopy (SEM) and coupled energy dispersive spectroscopy (EDS) were used to evaluate surface and chemical elements. ISO 6876‐2012 and ASTM‐C266‐07 specifications were followed to evaluate flow, setting time (moist and dry), solubility and radiopacity. Also, pH analysis at 37 and 100 °C was performed. Shapiro–Wilk and Mixed ANOVA (within and between the effects of the subjects), Levene, and a post hoc analyses with Bonferroni correction were performed (P < 0.05).Results: Vibrational spectroscopy revealed peaks of tricalcium silicate, dicalcium silicate and zirconium dioxide. Chemical changes in the Raman spectra during heating were discrete, as the inorganic content predominated the signalling for all root canal sealers. FT‐IR analysis exhibited spectral changes in water absorption for EndoSequence BC Sealer HiFlow and Bio‐C Sealer, probably related to dehydration. For BioRoot RCS and AH Plus, no significant chemical changes were observed. Bio‐C Sealer exhibited a band of polyethylene glycol only after heating to 100 °C, probably related to its thermal decomposition. SEM/EDS analysis corroborated the composition results observed in vibrational spectroscopy for all materials. Heating to 100 °C significantly changed the flowability of all calcium silicate‐based sealers with a wide variation in setting times at both temperatures, along with solubility levels above ISO standards. For all tested sealers, radiopacity fulfilled the requirements, and pH exhibited alkaline values.Conclusions: The tested calcium silicate‐based sealers were affected by heating. Calcium silicate‐based root canal sealers had high solubility which is a concern for their clinical use. AH Plus was the only root canal sealer that was stable after heating.
- 1 May 2019
- Published by Elsevier in Microchemical Journal
- Vol. 146, 842-849
Method for building a portable near infrared photometer based on LEDs and interference filters chosen by a spectral variable selection algorithm
- 1 May 2019
- Published by Elsevier in Microchemical Journal
- Vol. 146, 842-849
Method for building a portable near infrared photometer based on LEDs and interference filters chosen by a spectral variable selection algorithm
- 1 August 2018
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 157, 107-115
Comparison of macro and micro Raman measurement for reliable quantitative analysis of pharmaceutical polymorphs
- 1 August 2018
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 157, 107-115
Comparison of macro and micro Raman measurement for reliable quantitative analysis of pharmaceutical polymorphs