Julia Wróblewska
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Julia Wróblewska has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Robert Kowalski
Warsaw University of Technology, Faculty of Civil Engineering, Al. Armii Ludowej 16,00-637 Warsaw, Poland
3 shared publications - Michał Głowacki
Politechnika Warszawska Wydział Inżynierii Lądowej
1 shared publication
Latest Publications
- 3 September 2025
- Published by Polish Academy of Sciences Chancellery in Archives of Civil Engineering
- p. 63-76
Strains, thermal relaxation and strength loss of prestressing steel at fire temperature. Guidance on the practical use of the Eurocode 2-1-2 model
The paper gives guidance on the use of the EC2-1-2 model of degradation of the mechanical properties of prestressing steel at high temperature useful for estimating the loss of prestressing force in members exposed to fire. Adequate estimation of this force is crucial when calculating the fire resistance of prestressed members. If only the reduction in steel strength determined on the basis of the EC2-1-2 model is considered for the analysis, it may cause a significant underestimation of the prestress loss under fire conditions. In order to adequately estimate this force, it is necessary to sum up the strain of the prestressing tendons resulting from the degradation of their mechanical properties under the influence of high temperature and the free thermal elongation of the steel. The paper points out the existence of analogies between the elongation of prestressing steel heated under fire conditions and concrete creep under ordinary conditions. The guidelines for estimating thermal stress relaxation in tendons and determining the reduction in the secant modulus of prestressing steel under fire conditions are also provided.
- 3 September 2025
- Published by Polish Academy of Sciences Chancellery in Archives of Civil Engineering
- p. 63-76
Strains, thermal relaxation and strength loss of prestressing steel at fire temperature. Guidance on the practical use of the Eurocode 2-1-2 model
The paper gives guidance on the use of the EC2-1-2 model of degradation of the mechanical properties of prestressing steel at high temperature useful for estimating the loss of prestressing force in members exposed to fire. Adequate estimation of this force is crucial when calculating the fire resistance of prestressed members. If only the reduction in steel strength determined on the basis of the EC2-1-2 model is considered for the analysis, it may cause a significant underestimation of the prestress loss under fire conditions. In order to adequately estimate this force, it is necessary to sum up the strain of the prestressing tendons resulting from the degradation of their mechanical properties under the influence of high temperature and the free thermal elongation of the steel. The paper points out the existence of analogies between the elongation of prestressing steel heated under fire conditions and concrete creep under ordinary conditions. The guidelines for estimating thermal stress relaxation in tendons and determining the reduction in the secant modulus of prestressing steel under fire conditions are also provided.
- Open Access
- 1 December 2018
- Published by Polish Academy of Sciences Chancellery in Archives of Civil Engineering
- Vol. 64 (4) , 171-186
Application of a Sclerometer to the Preliminary Assessment of Concrete Quality in Structures After Fire
The paper presents a description and results of a study focused on the applicability of the sclerometric method to the preliminary assessment of concrete quality in structures after fire. Due to the high thermal inertia, concrete has non-uniform properties in the heated element cross-section. The greatest reduction of concrete compressive strength occurs on the heated surface. When assessing a structure after a fire, it is particularly important to determine the thickness of the damaged external concrete layer. Reinforced concrete beams exposed to high temperature on one side (a one-way heat transfer in the cross-section) for 0 (unheated element), 60, 120, 180 and 240 minutes were examined. A significant decrease of the rebound number on the elements heated surface was observed, depending on the heating duration. The obtained values of the relative rebound number reduction were comparable to the values of relative compressive strength decrease (determined on the basis of temperature) of concrete situated 15 mm from the heated surface.
- 1 December 2018
- Published by Polish Academy of Sciences Chancellery in Archives of Civil Engineering
- Vol. 64 (4) , 171-186
Open AccessApplication of a Sclerometer to the Preliminary Assessment of Concrete Quality in Structures After Fire
The paper presents a description and results of a study focused on the applicability of the sclerometric method to the preliminary assessment of concrete quality in structures after fire. Due to the high thermal inertia, concrete has non-uniform properties in the heated element cross-section. The greatest reduction of concrete compressive strength occurs on the heated surface. When assessing a structure after a fire, it is particularly important to determine the thickness of the damaged external concrete layer. Reinforced concrete beams exposed to high temperature on one side (a one-way heat transfer in the cross-section) for 0 (unheated element), 60, 120, 180 and 240 minutes were examined. A significant decrease of the rebound number on the elements heated surface was observed, depending on the heating duration. The obtained values of the relative rebound number reduction were comparable to the values of relative compressive strength decrease (determined on the basis of temperature) of concrete situated 15 mm from the heated surface.
- Open Access
- 1 December 2018
- Published by Polish Academy of Sciences Chancellery in Archives of Civil Engineering
- Vol. 64 (4) , 247-264
Thermal Bowing of Reinforced Concrete Elements Exposed to Non-Uniform Heating
The paper presents the test description and results of thermal bowing of RC beams exposed to non-uniform heating at high temperature. Bending of a non-uniformly heated element is caused by free thermal elongation of the material it is made of. The higher the temperature gradient, the greater the bending. In the case when an element is exposed to load and high temperature simultaneously, apart from free bending also deformation of the RC element may occur, which is caused by the decrease of the concrete or reinforcing steel mechanical properties. In order to examine the contribution of the deflection caused by thermal bowing to the total deformation of the bent element with a heated tension zone, an experimental study of freely heated (unloaded) beams was performed. RC beams were heated: (1) on three sides of the cross-section or (2) only on the bottom side. Deflection of elements loaded by a substitute temperature gradient was calculated using the Maxwell–Mohr formula. The test results show that deflection of freely heated RC beams (caused by the thermal bowing phenomenon) can be 10 to 20% of the total deflection of loaded RC beams with a heated tension zone.
- 1 December 2018
- Published by Polish Academy of Sciences Chancellery in Archives of Civil Engineering
- Vol. 64 (4) , 247-264
Open AccessThermal Bowing of Reinforced Concrete Elements Exposed to Non-Uniform Heating
The paper presents the test description and results of thermal bowing of RC beams exposed to non-uniform heating at high temperature. Bending of a non-uniformly heated element is caused by free thermal elongation of the material it is made of. The higher the temperature gradient, the greater the bending. In the case when an element is exposed to load and high temperature simultaneously, apart from free bending also deformation of the RC element may occur, which is caused by the decrease of the concrete or reinforcing steel mechanical properties. In order to examine the contribution of the deflection caused by thermal bowing to the total deformation of the bent element with a heated tension zone, an experimental study of freely heated (unloaded) beams was performed. RC beams were heated: (1) on three sides of the cross-section or (2) only on the bottom side. Deflection of elements loaded by a substitute temperature gradient was calculated using the Maxwell–Mohr formula. The test results show that deflection of freely heated RC beams (caused by the thermal bowing phenomenon) can be 10 to 20% of the total deflection of loaded RC beams with a heated tension zone.
- 5 December 2017
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in MATERIAŁY BUDOWLANE
- Vol. 1 (12) , 76-77
Nieniszczące metody oceny betonu w konstrukcji po pożarze
- 5 December 2017
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in MATERIAŁY BUDOWLANE
- Vol. 1 (12) , 76-77
Nieniszczące metody oceny betonu w konstrukcji po pożarze
- 5 October 2017
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in MATERIAŁY BUDOWLANE
- Vol. 1 (10) , 136-138
Semi-nieniszczące metody oceny betonu w konstrukcji po pożarze
- 5 October 2017
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in MATERIAŁY BUDOWLANE
- Vol. 1 (10) , 136-138
Semi-nieniszczące metody oceny betonu w konstrukcji po pożarze
- 5 July 2017
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in MATERIAŁY BUDOWLANE
- Vol. 1 (7) , 13-15
Laboratoryjne metody oceny betonu w konstrukcji po pożarze
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj?ce swoich czytelnik?w o najnowszych osi?gni?ciach naukowych i nowoczesnych rozwi?zaniach technicznych w Polsce i na ?wiecie, popularyzuje problemy techniczne oraz poszerza wiedz? i kultur? techniczn?.
- 5 July 2017
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in MATERIAŁY BUDOWLANE
- Vol. 1 (7) , 13-15
Laboratoryjne metody oceny betonu w konstrukcji po pożarze
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj?ce swoich czytelnik?w o najnowszych osi?gni?ciach naukowych i nowoczesnych rozwi?zaniach technicznych w Polsce i na ?wiecie, popularyzuje problemy techniczne oraz poszerza wiedz? i kultur? techniczn?.
- 5 June 2017
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in MATERIAŁY BUDOWLANE
- Vol. 1 (6) , 44-45
Czynniki i zjawiska wpływające na wytrzymałość betonu w konstrukcjach po pożarze
- 5 June 2017
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in MATERIAŁY BUDOWLANE
- Vol. 1 (6) , 44-45
Czynniki i zjawiska wpływające na wytrzymałość betonu w konstrukcjach po pożarze