Michal Fratczak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michal Fratczak has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Pawel Nowak
Silesian University of Technology
9 shared publications - Jacek Czeczot
Silesian University of Technology
5 shared publications Jacek Czeczot
4 shared publications- Tomasz Klopot
Politech Slaska, Katedra Automatyki & Robotyki, Ul Akad 16, PL-44100 Gliwice, Poland
4 shared publications - Patryk Grelewicz
Silesian University of Technology
3 shared publications - Andrzej Ordys
Warsaw University of Technology
2 shared publications
Latest Publications
- Open Access
- 1 April 2026
- Published by WNGB Scientific Publishing House Sp. z o.o. in Advances in Science and Technology Research Journal
- Vol. 20 (4) , 413-426
Concept of the advanced cloud-based autotuning procedure for PID controllers implemented in programmable logic controllers
This paper presents a concept of the cloud -based tool that extends the auto-tuning capabilities accessible in the PID function blocks available in Programmable Logic Controllers. Based on the data collected during the built-in auto-tuning experiment, a dynamical model of the process is obtained...
- 1 April 2026
- Published by WNGB Scientific Publishing House Sp. z o.o. in Advances in Science and Technology Research Journal
- Vol. 20 (4) , 413-426
Open AccessConcept of the advanced cloud-based autotuning procedure for PID controllers implemented in programmable logic controllers
This paper presents a concept of the cloud -based tool that extends the auto-tuning capabilities accessible in the PID function blocks available in Programmable Logic Controllers. Based on the data collected during the built-in auto-tuning experiment, a dynamical model of the process is obtained...
- Open Access
- 1 December 2025
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Advances in Science and Technology Research Journal
- Vol. 19 (12) , 249-256
Controller tunning for flow-through heater using artificial intelligence based on digital twin with recurrent neural networks
The presented research results are related to the modelling and simulation of technological processes using recurrent neural networks (RNN). This paper presents the application of such modelling technique for a flow-through heater. The structure of the RNN is presented and the correctness of the...
- 1 December 2025
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Advances in Science and Technology Research Journal
- Vol. 19 (12) , 249-256
Open AccessController tunning for flow-through heater using artificial intelligence based on digital twin with recurrent neural networks
The presented research results are related to the modelling and simulation of technological processes using recurrent neural networks (RNN). This paper presents the application of such modelling technique for a flow-through heater. The structure of the RNN is presented and the correctness of the...
- 13 September 2024
- Published by Elsevier in ISA Transactions
- Vol. 154, 432-444
Practical approach to mid-ranging control of double-unit actuating systems
- 13 September 2024
- Published by Elsevier in ISA Transactions
- Vol. 154, 432-444
Practical approach to mid-ranging control of double-unit actuating systems
- Open Access
Stealthy Cyberattacks Detection Based on Control Performance Assessment Methods for the Air Conditioning Industrial Installation
This paper aims to study the workflow of the detection centre of stealthy attacks on industrial installations that generate an increase in energy consumption. Such long-lasting, undetected attacks on industrial facilities make production more expensive and less competitive or damage the installation in the long term. We present the concept of the remote detection system of cyberattacks directed at maliciously changing the controlled variable in an industrial process air conditioning system. The monitored signals are gathered at the PLC-controlled installation and sent to the remote detection system, where the discrepancies of signals are analysed based on the Control Performance Assessment indices. The results of performed tests prove the legitimacy of the adopted approach.
Open AccessStealthy Cyberattacks Detection Based on Control Performance Assessment Methods for the Air Conditioning Industrial Installation
This paper aims to study the workflow of the detection centre of stealthy attacks on industrial installations that generate an increase in energy consumption. Such long-lasting, undetected attacks on industrial facilities make production more expensive and less competitive or damage the installation in the long term. We present the concept of the remote detection system of cyberattacks directed at maliciously changing the controlled variable in an industrial process air conditioning system. The monitored signals are gathered at the PLC-controlled installation and sent to the remote detection system, where the discrepancies of signals are analysed based on the Control Performance Assessment indices. The results of performed tests prove the legitimacy of the adopted approach.
- Open Access
- 14 December 2022
- Published by MDPI AG in Preprints.org
Stealthy Cyberattacks Detection Based on Control Performance Assessment Methods for the Air Conditioning Industrial Installation
The paper aims to study the workflow of the detection center of stealthy attacks on industrial installations that generate increase in energy consumption while avoiding triggering fault detection and damaging the installation. Such long-lasting attacks on industrial facilities make production more expensive and less competitive. We present the concept of the remote detection system of cyberattacks directed at maliciously changing the controlled variable in an industrial process air conditioning system. The monitored signals are gathered at the PLC-controlled installation and sent to the remote detection system, where the discrepancies of signals are analyzed based on the Control Performance Assessment indices. The results of performed tests prove the legitimacy of the adopted approach.
- 14 December 2022
- Published by MDPI AG in Preprints.org
Open AccessStealthy Cyberattacks Detection Based on Control Performance Assessment Methods for the Air Conditioning Industrial Installation
The paper aims to study the workflow of the detection center of stealthy attacks on industrial installations that generate increase in energy consumption while avoiding triggering fault detection and damaging the installation. Such long-lasting attacks on industrial facilities make production more expensive and less competitive. We present the concept of the remote detection system of cyberattacks directed at maliciously changing the controlled variable in an industrial process air conditioning system. The monitored signals are gathered at the PLC-controlled installation and sent to the remote detection system, where the discrepancies of signals are analyzed based on the Control Performance Assessment indices. The results of performed tests prove the legitimacy of the adopted approach.
- Open Access
ADRC-Based Habituating Control of Double-Heater Heat Source
This paper deals with the proposition of improvement in the performance of a heat source by modification of its structure and by deriving a dedicated control system. Traditional heat sources consist of a single heater of high nominal power, but slow dynamics, that is regulated by a single closed loop control system. In this paper, an existing heater serially-connected with a supplemental heater with low nominal power but fast dynamics is proposed. A dedicated control system was derived with two active disturbance rejection controllers (ADRC) implemented in the habituating control structure. The proposed solution was validated using a virtual commissioning procedure where the heating system was simulated in the SIEMENS® Simit v10.3 industrial software, and ADRC controllers were implemented in SIEMENS® PLCSIM Advanced using dedicated library function blocks. The results showed the superiority of the proposed approach in comparison with the traditional single closed loop solution. The proposed dedicated habituating control system provided better robustness to the changes in dynamics of a heat source and to the measurement noise. At the same time, it will ensure lower (or in some cases comparable) values of popular closed loop performance indices.
Open AccessADRC-Based Habituating Control of Double-Heater Heat Source
This paper deals with the proposition of improvement in the performance of a heat source by modification of its structure and by deriving a dedicated control system. Traditional heat sources consist of a single heater of high nominal power, but slow dynamics, that is regulated by a single closed loop control system. In this paper, an existing heater serially-connected with a supplemental heater with low nominal power but fast dynamics is proposed. A dedicated control system was derived with two active disturbance rejection controllers (ADRC) implemented in the habituating control structure. The proposed solution was validated using a virtual commissioning procedure where the heating system was simulated in the SIEMENS® Simit v10.3 industrial software, and ADRC controllers were implemented in SIEMENS® PLCSIM Advanced using dedicated library function blocks. The results showed the superiority of the proposed approach in comparison with the traditional single closed loop solution. The proposed dedicated habituating control system provided better robustness to the changes in dynamics of a heat source and to the measurement noise. At the same time, it will ensure lower (or in some cases comparable) values of popular closed loop performance indices.
- 1 January 2018
- Published by Elsevier in Applied Thermal Engineering
- Vol. 129, 549-556
Practical validation of the effective control of liquid–liquid heat exchangers by distributed parameter balance-based adaptive controller
- 1 January 2018
- Published by Elsevier in Applied Thermal Engineering
- Vol. 129, 549-556
Practical validation of the effective control of liquid–liquid heat exchangers by distributed parameter balance-based adaptive controller
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 14, 301-306
Dynamical aspects of multi-input single-output control for heat distribution processes: Case study
In this paper, the possibility of Multi-Input Single-Output control of the heat distribution processes is investigated. Based on the validated model of the example experimental setup, the static and dynamical properties of the process are investigated and discussed in terms of control performance and efficiency. Two potential manipulating variables are considered and different control strategies are discussed, including control by only single manipulating variable and by the proper and simultaneous adjustment of both of them. The energy efficiency is also considered.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 14, 301-306
Dynamical aspects of multi-input single-output control for heat distribution processes: Case study
In this paper, the possibility of Multi-Input Single-Output control of the heat distribution processes is investigated. Based on the validated model of the example experimental setup, the static and dynamical properties of the process are investigated and discussed in terms of control performance and efficiency. Two potential manipulating variables are considered and different control strategies are discussed, including control by only single manipulating variable and by the proper and simultaneous adjustment of both of them. The energy efficiency is also considered.
- 26 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1170-1175
Cascade balance-based adaptive control of heating system — Simulation validation
This paper is dedicated to simulation validation of cascade control structure for heating system consisting of single heat source and single heat receiver. In this structure, two Balance-Based Adaptive Controllers are applied. One of them has the conventional form while the second one (so-called distributed parameter Balance-Based Adaptive Controller operating in primary loop) is derived based on simplified distributed parameter modeling of plate heat exchanger. Modeling of heating system is based on measurement data collected from real laboratory plant and the simulation validation shows significant superiority of the suggested control approach in terms of control performance.
- 26 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1170-1175
Cascade balance-based adaptive control of heating system — Simulation validation
This paper is dedicated to simulation validation of cascade control structure for heating system consisting of single heat source and single heat receiver. In this structure, two Balance-Based Adaptive Controllers are applied. One of them has the conventional form while the second one (so-called distributed parameter Balance-Based Adaptive Controller operating in primary loop) is derived based on simplified distributed parameter modeling of plate heat exchanger. Modeling of heating system is based on measurement data collected from real laboratory plant and the simulation validation shows significant superiority of the suggested control approach in terms of control performance.
- 1 April 2016
- Published by Elsevier in Applied Thermal Engineering
- Vol. 98, 880-893
Simplified dynamical input–output modeling of plate heat exchangers – case study
- 1 April 2016
- Published by Elsevier in Applied Thermal Engineering
- Vol. 98, 880-893
Simplified dynamical input–output modeling of plate heat exchangers – case study