Sergey Alekseevich Koskin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sergey Alekseevich Koskin has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Ivan Ruslanovich Stepanets
Medical centre “Okodent
5 shared publications Yu. E. Shelepin
Pavlov Institute of Physiology, Russian Academy of Sciences
5 shared publications- Aleksey Nikolaevich Kulikov
S.M. Kirov Military Medical Academy
4 shared publications Iu E Shelepin
3 shared publicationsS. V. Pronin
Pavlov Institute of Physiology, Russian Academy of Sciences
3 shared publicationsA F Sobolev
2 shared publications
Latest Publications
- Open Access
- 5 October 2026
- Published by PE Polunina Elizareta Gennadievna in Ophthalmology in Russia
- Vol. 23 (3) , 549-556
Near, Intermediate and Distance Vision Assessment after Intraocular Lens Implantation: A Review
In recent decades, the widespread use of digital technologies, increased life expectancy, and sustained professional and social activity among older adults have significantly raised expectations for visual performance at multiple working distances. In patients with presbyopia and age-related cataract undergoing intraocular lens (IOL) implantation, the assessment of visual function at far, intermediate, and near distances has therefore become increasingly important. However, in clinical practice and scientific research there is still no single standardized approach to determining the metric values of these distances. This narrative review analyzes Russian and international publications, regulatory documents, professional guidelines, and manufacturer data related to the assessment of visual acuity at far, intermediate, and near distances. The review demonstrates that distance visual acuity is evaluated at varying test distances ranging to 6 m. Intermediate viewing distance shows the greatest variability, ranging from 50 to 80 cm across studies, largely reflecting differences in visual tasks and typical distances to digital devices. Near visual acuity is most commonly assessed at distances of 33–40 cm. Special attention is given to defocus curves as an adjunctive method for evaluating depth of focus and functional visual performance in pseudophakic patients. The limitations of interpreting defocus curves without direct correlation to real-distance visual acuity measurements are discussed. The need for unification of approaches to assessing vision at an intermediate distance in domestic ophthalmology and the feasibility of using a distance of 66 cm as clinically significant, functionally justified and the most universal seems relevant today.
- 5 October 2026
- Published by PE Polunina Elizareta Gennadievna in Ophthalmology in Russia
- Vol. 23 (3) , 549-556
Open AccessNear, Intermediate and Distance Vision Assessment after Intraocular Lens Implantation: A Review
In recent decades, the widespread use of digital technologies, increased life expectancy, and sustained professional and social activity among older adults have significantly raised expectations for visual performance at multiple working distances. In patients with presbyopia and age-related cataract undergoing intraocular lens (IOL) implantation, the assessment of visual function at far, intermediate, and near distances has therefore become increasingly important. However, in clinical practice and scientific research there is still no single standardized approach to determining the metric values of these distances. This narrative review analyzes Russian and international publications, regulatory documents, professional guidelines, and manufacturer data related to the assessment of visual acuity at far, intermediate, and near distances. The review demonstrates that distance visual acuity is evaluated at varying test distances ranging to 6 m. Intermediate viewing distance shows the greatest variability, ranging from 50 to 80 cm across studies, largely reflecting differences in visual tasks and typical distances to digital devices. Near visual acuity is most commonly assessed at distances of 33–40 cm. Special attention is given to defocus curves as an adjunctive method for evaluating depth of focus and functional visual performance in pseudophakic patients. The limitations of interpreting defocus curves without direct correlation to real-distance visual acuity measurements are discussed. The need for unification of approaches to assessing vision at an intermediate distance in domestic ophthalmology and the feasibility of using a distance of 66 cm as clinically significant, functionally justified and the most universal seems relevant today.
- 31 March 2026
- Published by ECO-Vector LLC (Publications) in Ophthalmology Reports
- Vol. 19 (1) , 41-50
Changes in reading parameters in patients with wet age-related macular degeneration after angiogenesis inhibitor therapy
BACKGROUND: Reading tests are increasingly used to assess visual function in patients with age-related macular degeneration, especially after intravitreal injections. AIM: The study aimed to assess whether the developed standard ophthalmic test cards can be used as an additional method to monitor visual function in Russian-speaking patients with wet age-related macular degeneration before and after angiogenesis inhibitor therapy based on a comparative analysis of reading parameters and traditional near visual acuity. METHODS: A total of 19 patients with emmetropia (38 eyes) aged 55–83 years were examined before and one month after intravitreal injection of aflibercept (2.0 mg). Treated and fellow eyes were included in group 1 and 2, respectively. Near visual acuity and reading parameters (maximum reading speed, critical print size, and reading visual acuity) were assessed using standard test cards. RESULTS: Best corrected near visual acuity in group 1 increased by an average of 0.11 (p 0.05) in 12 (63%) patients. Maximum reading speed increased by an average of 9.7 words/min (p 0.05) in all patients (100%). Critical print size improved by 0.095 LogMAR (p 0.05) in 13 (68%) patients, reading visual acuity improved by 0.094 LogMAR (p 0.05) in 15 (79%) patients. CONCLUSION: Standard Russian test cards assess the effectiveness of treatment of wet age-related macular degeneration, and a substantial improvement in reading parameters after intravitreal injections of angiogenesis inhibitors compared with traditional near visual acuity supports their use in clinical practice.
- 31 March 2026
- Published by ECO-Vector LLC (Publications) in Ophthalmology Reports
- Vol. 19 (1) , 41-50
Changes in reading parameters in patients with wet age-related macular degeneration after angiogenesis inhibitor therapy
BACKGROUND: Reading tests are increasingly used to assess visual function in patients with age-related macular degeneration, especially after intravitreal injections. AIM: The study aimed to assess whether the developed standard ophthalmic test cards can be used as an additional method to monitor visual function in Russian-speaking patients with wet age-related macular degeneration before and after angiogenesis inhibitor therapy based on a comparative analysis of reading parameters and traditional near visual acuity. METHODS: A total of 19 patients with emmetropia (38 eyes) aged 55–83 years were examined before and one month after intravitreal injection of aflibercept (2.0 mg). Treated and fellow eyes were included in group 1 and 2, respectively. Near visual acuity and reading parameters (maximum reading speed, critical print size, and reading visual acuity) were assessed using standard test cards. RESULTS: Best corrected near visual acuity in group 1 increased by an average of 0.11 (p 0.05) in 12 (63%) patients. Maximum reading speed increased by an average of 9.7 words/min (p 0.05) in all patients (100%). Critical print size improved by 0.095 LogMAR (p 0.05) in 13 (68%) patients, reading visual acuity improved by 0.094 LogMAR (p 0.05) in 15 (79%) patients. CONCLUSION: Standard Russian test cards assess the effectiveness of treatment of wet age-related macular degeneration, and a substantial improvement in reading parameters after intravitreal injections of angiogenesis inhibitors compared with traditional near visual acuity supports their use in clinical practice.
- 9 March 2024
- Published by ECO-Vector LLC in Ophthalmology Reports
- Vol. 17 (1) , 7-20
The influence of some general diseases for changes on the ocular surface after trabeculectomy
BACKGROUND: By now, possible effects of diabetes mellitus and arterial hypertension on the ocular surface changes after trabeculectomy have not been evaluated. AIM: Analysis of the effects of arterial hypertension therapy and diabetes mellitus on the ocular surface changes after trabeculectomy. MATERIALS AND METHODS: The study group consisted of 443 patients, including those with arterial hypertension (179 patients), non insulin dependent compensated type 2 diabetes mellitus (25 patients) and their combination (53 persons), operated in 2016–2020 in the City Multifield Hospital No. 2, Saint-Petersburg, for primary open-angle noncompensated glaucoma and then observed for 6 to 24 months. The dynamics of ocular surface disease index (OSDI), tear film break-up time (TBUT), and amount of total tear production has been studied. RESULTS: The probability of the trabeculectomy success did not depend on the concomitant comorbidity. In contrast to intraocular pressure, the criteria for subjective and objective assessment of the ocular surface state were not subject to such obvious changes. In diabetic patients, the studied criteria have not changed compared to the baseline. CONCLUSIONS: The mentioned systemic diseases do not influence the state of the ocular surface in patients with glaucoma, and are not an independent risk factor for the failure of the IOP-lowering surgical procedure. The presence of diabetes mellitus prevents the accompanying a successful trabeculectomy regression of symptoms and clinical and functional signs of dry eye disease.
- 9 March 2024
- Published by ECO-Vector LLC in Ophthalmology Reports
- Vol. 17 (1) , 7-20
The influence of some general diseases for changes on the ocular surface after trabeculectomy
BACKGROUND: By now, possible effects of diabetes mellitus and arterial hypertension on the ocular surface changes after trabeculectomy have not been evaluated. AIM: Analysis of the effects of arterial hypertension therapy and diabetes mellitus on the ocular surface changes after trabeculectomy. MATERIALS AND METHODS: The study group consisted of 443 patients, including those with arterial hypertension (179 patients), non insulin dependent compensated type 2 diabetes mellitus (25 patients) and their combination (53 persons), operated in 2016–2020 in the City Multifield Hospital No. 2, Saint-Petersburg, for primary open-angle noncompensated glaucoma and then observed for 6 to 24 months. The dynamics of ocular surface disease index (OSDI), tear film break-up time (TBUT), and amount of total tear production has been studied. RESULTS: The probability of the trabeculectomy success did not depend on the concomitant comorbidity. In contrast to intraocular pressure, the criteria for subjective and objective assessment of the ocular surface state were not subject to such obvious changes. In diabetic patients, the studied criteria have not changed compared to the baseline. CONCLUSIONS: The mentioned systemic diseases do not influence the state of the ocular surface in patients with glaucoma, and are not an independent risk factor for the failure of the IOP-lowering surgical procedure. The presence of diabetes mellitus prevents the accompanying a successful trabeculectomy regression of symptoms and clinical and functional signs of dry eye disease.
- 9 March 2024
- Published by ECO-Vector LLC in Ophthalmology Reports
- Vol. 17 (1) , 51-62
Standardized Russian reading chart for assessing reading parameters
BACKGROUND: A number of charts based on checking reading parameters are increasingly being used to assess visual functions. These charts are standardized, translated into many languages. The development of a Russian chart based on international standards and the determination of age norms of clinical reading parameters will allow it to be used for a more accurate assessment of the dynamics of diseases and treatment results. AIM: The aim is to determine the normal reading parameters in patients of different age groups. MATERIALS AND METHODS: Based on international standards, two Russian charts have been developed to study reading parameters. Reading parameters were determined during one session in 135 subjects, divided into 3 groups: I — 18–39 years, II — 40–59 years, and III — 60–81 years. Three main parameters were studied: maximum reading speed, critical print size, and reading acuity (RA). RESULTS: As a result of the study, age norms for basic reading parameters were determined. Maximum reading speed in group I was 192.5 ± 1.2, in group II — 180.6 ± 1.1 and in group III — 168.9 ± 0.8 words/min. Critical print size in group I was 0.14 ± 0.01, in group II — 0.24 ± 0.01, and in group III — 0.36 ± 0.01 logMAR. The reading acuity in group I was 0.009 ± 0.006, in group II — 0.075 ± 0.04, in group III — 0.143 ± 0.005 logMAR. The differences between the studied parameters in groups I/II, I/III and II/III were statistically significant (p 0.05). CONCLUSIONS: The indicators of reading parameters obtained during the study can be used as approximate age norms.
- 9 March 2024
- Published by ECO-Vector LLC in Ophthalmology Reports
- Vol. 17 (1) , 51-62
Standardized Russian reading chart for assessing reading parameters
BACKGROUND: A number of charts based on checking reading parameters are increasingly being used to assess visual functions. These charts are standardized, translated into many languages. The development of a Russian chart based on international standards and the determination of age norms of clinical reading parameters will allow it to be used for a more accurate assessment of the dynamics of diseases and treatment results. AIM: The aim is to determine the normal reading parameters in patients of different age groups. MATERIALS AND METHODS: Based on international standards, two Russian charts have been developed to study reading parameters. Reading parameters were determined during one session in 135 subjects, divided into 3 groups: I — 18–39 years, II — 40–59 years, and III — 60–81 years. Three main parameters were studied: maximum reading speed, critical print size, and reading acuity (RA). RESULTS: As a result of the study, age norms for basic reading parameters were determined. Maximum reading speed in group I was 192.5 ± 1.2, in group II — 180.6 ± 1.1 and in group III — 168.9 ± 0.8 words/min. Critical print size in group I was 0.14 ± 0.01, in group II — 0.24 ± 0.01, and in group III — 0.36 ± 0.01 logMAR. The reading acuity in group I was 0.009 ± 0.006, in group II — 0.075 ± 0.04, in group III — 0.143 ± 0.005 logMAR. The differences between the studied parameters in groups I/II, I/III and II/III were statistically significant (p 0.05). CONCLUSIONS: The indicators of reading parameters obtained during the study can be used as approximate age norms.
- 20 February 2023
- Published by ECO-Vector LLC in Ophthalmology Reports
- Vol. 15 (4) , 75-83
Intermittent exotropia with convergence insufficiency — diagnostics, methods of invasive treatment
The review analyzes most common injection and surgical methods of treatment of intermittent exotropia of convergence insufficiency: injections of botulinum toxin type A, injections of bupivacaine, bilateral recession of lateral rectus muscles with imposition of fixation sutures or without it (including hemi-hang-back, no-noose technique), recession of lateral rectus muscles according to Stellard, unilateral or bilateral resection of medial rectus muscle, a combination of resection with recession in one eye, the formation of a duplication of medial rectus muscle. The results before and after treatment are presented. The results of evaluating the effectiveness of invasive therapy in patients with exotropia with convergence insufficiency are summed up.
- 20 February 2023
- Published by ECO-Vector LLC in Ophthalmology Reports
- Vol. 15 (4) , 75-83
Intermittent exotropia with convergence insufficiency — diagnostics, methods of invasive treatment
The review analyzes most common injection and surgical methods of treatment of intermittent exotropia of convergence insufficiency: injections of botulinum toxin type A, injections of bupivacaine, bilateral recession of lateral rectus muscles with imposition of fixation sutures or without it (including hemi-hang-back, no-noose technique), recession of lateral rectus muscles according to Stellard, unilateral or bilateral resection of medial rectus muscle, a combination of resection with recession in one eye, the formation of a duplication of medial rectus muscle. The results before and after treatment are presented. The results of evaluating the effectiveness of invasive therapy in patients with exotropia with convergence insufficiency are summed up.
- 1 August 2022
- Published by Optica Publishing Group in Journal of Optical Technology
- Vol. 89 (8) , 490-497
Synthesis of isognostic text images for visual performance evaluation
Subject of study. Principles and technologies for synthesis of test letter charts and standardization of measurements of reading parameters for evaluation of visual performance in the reading process, which is the most important type of human visual activity, are the subjects of the study. Aim of study. The study was aimed at developing a synthesis algorithm for textual isognostic images for quantitatively evaluating reading parameters as indicators of the state of visual performance that ensure the correlation between optical and semantic properties based on optical and optometric standards. Methods of study. A set of test images in the form of texts was created using digital methods for image synthesis. The text images were standardized for measuring reading parameters using optometric methods. Main results. A set of texts was synthesized and standardized considering the complexity and number of symbols in words, the frequency of occurrence and average width of Russian letters, the lengths of sentences, the angular sizes of characters, and the contrast. The text was standardized according to the angular visual acuity and conventional optometric standard ISO 8596, 2009. The synthesized test images comprised sets of text fragments of similar numbers of characters but different angular sizes. The sizes of the characters were correlated with the threshold angular values characterizing visual acuity according to optometric standards. The maximum reading speed, critical print size, and reading acuity were measured in 29 healthy adult test subjects to assess the reproducibility of results obtained using the synthesized test images. The measurements were performed twice for each test subject using two different charts synthesized using the developed method. No statistically significant difference was observed between the measurement results, which indicated good reproducibility of the results obtained using this test. Practical significance. The proposed algorithm for synthesis of standardized texts for assessing reading parameters is the simplest general method for a broad application in routine effectiveness evaluation of the therapy of macular zone pathology and lens fitting for short working distances.
- 1 August 2022
- Published by Optica Publishing Group in Journal of Optical Technology
- Vol. 89 (8) , 490-497
Synthesis of isognostic text images for visual performance evaluation
Subject of study. Principles and technologies for synthesis of test letter charts and standardization of measurements of reading parameters for evaluation of visual performance in the reading process, which is the most important type of human visual activity, are the subjects of the study. Aim of study. The study was aimed at developing a synthesis algorithm for textual isognostic images for quantitatively evaluating reading parameters as indicators of the state of visual performance that ensure the correlation between optical and semantic properties based on optical and optometric standards. Methods of study. A set of test images in the form of texts was created using digital methods for image synthesis. The text images were standardized for measuring reading parameters using optometric methods. Main results. A set of texts was synthesized and standardized considering the complexity and number of symbols in words, the frequency of occurrence and average width of Russian letters, the lengths of sentences, the angular sizes of characters, and the contrast. The text was standardized according to the angular visual acuity and conventional optometric standard ISO 8596, 2009. The synthesized test images comprised sets of text fragments of similar numbers of characters but different angular sizes. The sizes of the characters were correlated with the threshold angular values characterizing visual acuity according to optometric standards. The maximum reading speed, critical print size, and reading acuity were measured in 29 healthy adult test subjects to assess the reproducibility of results obtained using the synthesized test images. The measurements were performed twice for each test subject using two different charts synthesized using the developed method. No statistically significant difference was observed between the measurement results, which indicated good reproducibility of the results obtained using this test. Practical significance. The proposed algorithm for synthesis of standardized texts for assessing reading parameters is the simplest general method for a broad application in routine effectiveness evaluation of the therapy of macular zone pathology and lens fitting for short working distances.
- Open Access
- 15 December 2020
- Published by ECO-Vector LLC in Ophthalmology Reports
- Vol. 13 (4) , 47-55
Standardized ophthalmic tests for evaluating reading parameters: a brief historical review
In the review, the analysis of the most common ophthalmic standardized tests for evaluating reading was carried out: BaileyLovie Word Reading Charts, MNREAD Acuity Chart, Radner reading chart, SmithKettlewell Reading Test (SKread), IReST, Salzburg Reading Desk, Ramulu test, Radner paragraph optotypes, Balsam AlabdulkaderLeat (BAL) chart, Chinese Reading Acuity Charts (C-READ), chart for reading threshold and reading speed evaluation by T.S. Egorova. The following parameters were considered: maximum reading speed, reading threshold, reading acuity, reading accessibility index, threshold reading speed. Recovering the ability to read fluently is one of the criteria for assessing the success of treatment, as well as quality of life for patients of various age groups
- 15 December 2020
- Published by ECO-Vector LLC in Ophthalmology Reports
- Vol. 13 (4) , 47-55
Open AccessStandardized ophthalmic tests for evaluating reading parameters: a brief historical review
In the review, the analysis of the most common ophthalmic standardized tests for evaluating reading was carried out: BaileyLovie Word Reading Charts, MNREAD Acuity Chart, Radner reading chart, SmithKettlewell Reading Test (SKread), IReST, Salzburg Reading Desk, Ramulu test, Radner paragraph optotypes, Balsam AlabdulkaderLeat (BAL) chart, Chinese Reading Acuity Charts (C-READ), chart for reading threshold and reading speed evaluation by T.S. Egorova. The following parameters were considered: maximum reading speed, reading threshold, reading acuity, reading accessibility index, threshold reading speed. Recovering the ability to read fluently is one of the criteria for assessing the success of treatment, as well as quality of life for patients of various age groups
- 1 May 2019
- Published by Optica Publishing Group in Journal of Optical Technology
- Vol. 86 (5) , 301-305
Comparative analysis of the results of various visometry methods
- 1 May 2019
- Published by Optica Publishing Group in Journal of Optical Technology
- Vol. 86 (5) , 301-305
Comparative analysis of the results of various visometry methods
- 1 September 2018
- Published by Pleiades Publishing Ltd in Human Physiology
- Vol. 44 (5) , 510-516
Dependence between the Size of the Foveola and the Parameters of Visual Perception
The purpose of this study was to investigate the relationship between the morphological parameters of the fovea, foveola, and foveolita of the human eye and the psychophysical and...
- 1 September 2018
- Published by Pleiades Publishing Ltd in Human Physiology
- Vol. 44 (5) , 510-516
Dependence between the Size of the Foveola and the Parameters of Visual Perception
The purpose of this study was to investigate the relationship between the morphological parameters of the fovea, foveola, and foveolita of the human eye and the psychophysical and...
- 1 January 2018
- Published by Stavropol State Medical University in Medical news of the North Caucasus
- Vol. 13 (3)
Drug induced patomorphosis in parodont and environmental bone tissue in experimental use of corticosteroids
- 1 January 2018
- Published by Stavropol State Medical University in Medical news of the North Caucasus
- Vol. 13 (3)
Drug induced patomorphosis in parodont and environmental bone tissue in experimental use of corticosteroids