Sefer Avdiaj
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Sefer Avdiaj has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Bojan Erjavec
Institute of Metals and Technology
3 shared publicationsJanez Setina
Institute of Metals and Technology
2 shared publicationsJanez Šetina
Institute of Metals and Technology, Lepi pot 11, SI-1000 Ljubljana, Slovenia
2 shared publications- Arbër Zeqiraj
Department of Materials and Metallurgy, University of Mitrovica, Mitrovica, Kosovo
1 shared publication Ardita Kurtishaj
Department of Physics. University of Prishtina. Prishtina 10000, Kosovo
1 shared publicationErmir Rogova
1 shared publication
Latest Publications
- 14 May 2024
- Published by Elsevier in Technology in Society
- Vol. 77
Cryptocurrency blockchain and its carbon footprint: Anticipating future challenges
- 14 May 2024
- Published by Elsevier in Technology in Society
- Vol. 77
Cryptocurrency blockchain and its carbon footprint: Anticipating future challenges
- 4 May 2022
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 11 (2) , 1-4
Measurements of helium permeation in Zerodur glass used for the realisation of quantum pascal
In the new optical pressure standard Ultra-Low Expansion glass cavities were proposed to measure helium refractivity for a new realisation of the unit of pressure, pascal. However, it was noticed that the use of this type of material causes some difficulties. One of the main problems of ULE glass is the pumping effect for Helium. Therefore, instead of ULE, Zerodur glass was proposed as a material for the cavity. This proposal was given by the Vacuum Metrology team of the Physikalisch-Technische Bundesanstalt - PTB in the QuantumPascal project. In order to calculate the flow of helium gas through Zerodur glass one has to know the permeation constant K. Moreover, the modelling of time dependency of the flow requires the knowledge of diffusion constant D as well. The relation between them is given by K = S · D, where S is the solubility of Helium in glass. In our research work we measured permeation of helium gas in Zerodur. Measurements were performed in the temperature range 80 °C – 120 °C. Based on our results, we consider that the Zerodur material has potential to be used as cavity material for the new quantum standard of pressure.
- 4 May 2022
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 11 (2) , 1-4
Measurements of helium permeation in Zerodur glass used for the realisation of quantum pascal
In the new optical pressure standard Ultra-Low Expansion glass cavities were proposed to measure helium refractivity for a new realisation of the unit of pressure, pascal. However, it was noticed that the use of this type of material causes some difficulties. One of the main problems of ULE glass is the pumping effect for Helium. Therefore, instead of ULE, Zerodur glass was proposed as a material for the cavity. This proposal was given by the Vacuum Metrology team of the Physikalisch-Technische Bundesanstalt - PTB in the QuantumPascal project. In order to calculate the flow of helium gas through Zerodur glass one has to know the permeation constant K. Moreover, the modelling of time dependency of the flow requires the knowledge of diffusion constant D as well. The relation between them is given by K = S · D, where S is the solubility of Helium in glass. In our research work we measured permeation of helium gas in Zerodur. Measurements were performed in the temperature range 80 °C – 120 °C. Based on our results, we consider that the Zerodur material has potential to be used as cavity material for the new quantum standard of pressure.
- 1 April 2021
- Published by IOP Publishing in Metrologia
- Vol. 58 (3) , 035003
Transient heating in fixed length optical cavities for use as temperature and pressure standards
Optical refractometry techniques enable realization of both pressure and temperature directly from properties of the gas. The NIST refractometer, a fixed length optical cavity (FLOC) has previously been evaluated for operation as pressure standard, and now in this paper, is evaluated for the feasibility of operation as a primary temperature standard as well. The challenge is that during operation, one cavity is filled with gas. Gas dynamics predicts that this will result in heating which in turn will affect the cavity temperature uniformity, impeding the ability to measure the gas temperature with sufficient accuracy to make the standard useful as a primary standard for temperature or pressure. Temperature uniformity across the refractometer must be less than 0.5 mK for measurements of the refractivity to be sufficiently accurate for the FLOC. This paper compares computer modeling to laboratory measurements, enabling us to validate the model to predict thermal behavior and to accurately determine the measurement uncertainty of the technique. The results presented in this paper show that temperature of the glass elements of the refractometer and ‘thermal-shell’ copper chamber are equivalent to within 0.5 mK after an equilibration time of 3000 s (when going from 1 kPa to 100 kPa). This finding enables measurements of the copper chamber to determine the gas temperature to within an uncertainty ( k = 1) of 0.5 mK. Additionally, the NIST refractometer is evaluated for feasibility of operation as temperature standard.
- 1 April 2021
- Published by IOP Publishing in Metrologia
- Vol. 58 (3) , 035003
Transient heating in fixed length optical cavities for use as temperature and pressure standards
Optical refractometry techniques enable realization of both pressure and temperature directly from properties of the gas. The NIST refractometer, a fixed length optical cavity (FLOC) has previously been evaluated for operation as pressure standard, and now in this paper, is evaluated for the feasibility of operation as a primary temperature standard as well. The challenge is that during operation, one cavity is filled with gas. Gas dynamics predicts that this will result in heating which in turn will affect the cavity temperature uniformity, impeding the ability to measure the gas temperature with sufficient accuracy to make the standard useful as a primary standard for temperature or pressure. Temperature uniformity across the refractometer must be less than 0.5 mK for measurements of the refractivity to be sufficiently accurate for the FLOC. This paper compares computer modeling to laboratory measurements, enabling us to validate the model to predict thermal behavior and to accurately determine the measurement uncertainty of the technique. The results presented in this paper show that temperature of the glass elements of the refractometer and ‘thermal-shell’ copper chamber are equivalent to within 0.5 mK after an equilibration time of 3000 s (when going from 1 kPa to 100 kPa). This finding enables measurements of the copper chamber to determine the gas temperature to within an uncertainty ( k = 1) of 0.5 mK. Additionally, the NIST refractometer is evaluated for feasibility of operation as temperature standard.
- 20 March 2018
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 148 (11) , 116101
Note: Diffusion constant and solubility of helium in ULE glass at 23 °C
- 20 March 2018
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 148 (11) , 116101
Note: Diffusion constant and solubility of helium in ULE glass at 23 °C
- 1 December 2017
- Published by Elsevier in Measurement
- Vol. 111, 384-388
Flowmeter for very low gas flows of inert gases
- 1 December 2017
- Published by Elsevier in Measurement
- Vol. 111, 384-388
Flowmeter for very low gas flows of inert gases
- 8 May 2015
- Published by Springer Nature in MAPAN
- Vol. 30 (3) , 175-178
Volume Determination of Vacuum Vessels by Gas Expansion Method
- 8 May 2015
- Published by Springer Nature in MAPAN
- Vol. 30 (3) , 175-178
Volume Determination of Vacuum Vessels by Gas Expansion Method
- Open Access
- 31 December 2013
- Published by Leipzig University Library in Diffusion Fundamentals
- Vol. 20
Modelling the oxygen diffusion profile in St 707 non evaporable getter material
- 31 December 2013
- Published by Leipzig University Library in Diffusion Fundamentals
- Vol. 20
Open AccessModelling the oxygen diffusion profile in St 707 non evaporable getter material
- 25 May 2013
- Published by Springer Nature in Bulletin of Materials Science
- Vol. 36 (3) , 429-435
Effect of bias voltage on microstructure and mechanical properties of arc evaporated (Ti, Al)N hard coatings
- 25 May 2013
- Published by Springer Nature in Bulletin of Materials Science
- Vol. 36 (3) , 429-435
Effect of bias voltage on microstructure and mechanical properties of arc evaporated (Ti, Al)N hard coatings