Aleksandra A. Nenakhova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Aleksandra A. Nenakhova has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Boris N. Kozlov
Cardiology Research Institute, Tomsk National Research Medical Center, Russian Academy of Sciences (Cardiology Research Institute, Tomsk NRMC)
4 shared publications - Dmitri S. Panfilov
Cardiology Research Institute, Tomsk National Research Medical Center
2 shared publications - Vladimir M. Shipulin
Tomsk National Research Medical Center, Cardiology Research Institute
2 shared publications Alexander I Maksimov
Cardiovascular Surgery Department, Cardiology Research Institute, Tomsk National Research Medical Center, Tomsk, Russia
1 shared publicationAndrey G Miroshnichenko
Cardiovascular Surgery Department, Cardiology Research Institute, Tomsk National Research Medical Center, Tomsk, Russia
1 shared publicationGeorgiy G Nasrashvili
Cardiovascular Surgery Department, Cardiology Research Institute, Tomsk National Research Medical Center, Tomsk, Russia
1 shared publication
Latest Publications
- 29 September 2019
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 27 (8) , 646-651
Enhancement of flow measurement for graft verification
Background: We aimed to evaluate multiple transit-time flow measurements during coronary artery bypass grafting. Methods: Transit-time flow measurements were performed first on the arrested heart both with and without a proximal snare on the target coronary artery, second, after weaning from cardiopulmonary bypass, and third, before chest closure. Results: Among the 214 grafts considered, 9 (4.2%) were patent and 6 (2.8%) were failing. In the failed grafts, an abnormal transit-time flow was found during the first measurement, in 5 (2.3%) cases with a proximal snare and in one (0.47%) without a snare. In these cases, technical errors with the distal anastomoses were found and immediately corrected. A problem with the proximal anastomosis was found in one graft during the second measurement and corrected right away. Bending due to excessive length was found in 2 (0.93%) grafts during the third measurement, and graft repositioning was performed. The first transit-time flow measurement showed that mean graft flow was significantly decreased with a proximal snare compared to without a proximal snare, throughout the entire coronary territory. Pulsatility index during the first transit-time flow measurement was higher with a proximal snare than without one. Conclusions: The 3-time transit-time flow measurement strategy makes it possible to verify and immediately correct technical problems with coronary bypass grafts.
- 29 September 2019
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 27 (8) , 646-651
Enhancement of flow measurement for graft verification
Background: We aimed to evaluate multiple transit-time flow measurements during coronary artery bypass grafting. Methods: Transit-time flow measurements were performed first on the arrested heart both with and without a proximal snare on the target coronary artery, second, after weaning from cardiopulmonary bypass, and third, before chest closure. Results: Among the 214 grafts considered, 9 (4.2%) were patent and 6 (2.8%) were failing. In the failed grafts, an abnormal transit-time flow was found during the first measurement, in 5 (2.3%) cases with a proximal snare and in one (0.47%) without a snare. In these cases, technical errors with the distal anastomoses were found and immediately corrected. A problem with the proximal anastomosis was found in one graft during the second measurement and corrected right away. Bending due to excessive length was found in 2 (0.93%) grafts during the third measurement, and graft repositioning was performed. The first transit-time flow measurement showed that mean graft flow was significantly decreased with a proximal snare compared to without a proximal snare, throughout the entire coronary territory. Pulsatility index during the first transit-time flow measurement was higher with a proximal snare than without one. Conclusions: The 3-time transit-time flow measurement strategy makes it possible to verify and immediately correct technical problems with coronary bypass grafts.
- 1 June 2019
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 157 (6) , 2328-2336.e1
Nitric oxide provides myocardial protection when added to the cardiopulmonary bypass circuit during cardiac surgery: Randomized trial
- 1 June 2019
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 157 (6) , 2328-2336.e1
Nitric oxide provides myocardial protection when added to the cardiopulmonary bypass circuit during cardiac surgery: Randomized trial
- 28 February 2019
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 29 (1) , 117-123
Distal aortic remodelling after the standard and the elongated frozen elephant trunk procedure
OBJECTIVES: The The aim of this study was to evaluate abdominal aortic remodelling after the standard compared with the elongated frozen elephant trunk (FET) technique in patients with aortic dissection. METHODS: Twenty-six patients underwent surgery and were randomized into 2 groups. Fifteen patients were treated with the standard FET technique. Eleven patients were treated with the advanced FET technique using an additional thoracic stent graft implanted down to the coeliac artery, within 30 days after the first stent graft implantation. Preoperative and postoperative and 5-year follow-up computed tomography aortic scans were obtained along the stent graft (A), between the distal edge of the graft and the coeliac trunk (B) and at the abdominal aorta (C). RESULTS: In the standard FET group, positive and stable aortic remodelling occurred in segments A (100%), B (87%) and C (87%). Negative remodelling was found in 2/15 (13%) patients; 1 patient had an endovascular reintervention. In the elongated FET group, positive and stable remodelling were observed in segments A (100%), B (100%) and C (90.9%). Negative remodelling occurred in 1/11 (9.1%) patients. No reintervention was required. Cumulative survival, freedom from negative remodelling and distal aortic reintervention in the standard FET group and the elongated FET group were 72 vs 100% (P = 0.29); 67.5 vs 80% (P = 0.58) and 75 vs 100% (P = 0.61), respectively. CONCLUSIONS: The standard FET technique is an adequate measure to induce false lumen thrombosis and improve abdominal aortic remodelling. The elongated FET technique seems to be superior to the standard FET procedure in terms of freedom from aortic remodelling and the distal reintervention rate.
- 28 February 2019
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 29 (1) , 117-123
Distal aortic remodelling after the standard and the elongated frozen elephant trunk procedure
OBJECTIVES: The The aim of this study was to evaluate abdominal aortic remodelling after the standard compared with the elongated frozen elephant trunk (FET) technique in patients with aortic dissection. METHODS: Twenty-six patients underwent surgery and were randomized into 2 groups. Fifteen patients were treated with the standard FET technique. Eleven patients were treated with the advanced FET technique using an additional thoracic stent graft implanted down to the coeliac artery, within 30 days after the first stent graft implantation. Preoperative and postoperative and 5-year follow-up computed tomography aortic scans were obtained along the stent graft (A), between the distal edge of the graft and the coeliac trunk (B) and at the abdominal aorta (C). RESULTS: In the standard FET group, positive and stable aortic remodelling occurred in segments A (100%), B (87%) and C (87%). Negative remodelling was found in 2/15 (13%) patients; 1 patient had an endovascular reintervention. In the elongated FET group, positive and stable remodelling were observed in segments A (100%), B (100%) and C (90.9%). Negative remodelling occurred in 1/11 (9.1%) patients. No reintervention was required. Cumulative survival, freedom from negative remodelling and distal aortic reintervention in the standard FET group and the elongated FET group were 72 vs 100% (P = 0.29); 67.5 vs 80% (P = 0.58) and 75 vs 100% (P = 0.61), respectively. CONCLUSIONS: The standard FET technique is an adequate measure to induce false lumen thrombosis and improve abdominal aortic remodelling. The elongated FET technique seems to be superior to the standard FET procedure in terms of freedom from aortic remodelling and the distal reintervention rate.
- Open Access
- 17 January 2018
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 26 (6) , 972-976
The risk of spinal cord injury during the frozen elephant trunk procedure in acute aortic dissection
The aim of the study was to access the extended occlusion of the intercostal arteries by a stent graft in the development of postoperative spinal cord injury during aortic arch surgery using the frozen elephant trunk technique. A total of 37 consecutive patients underwent total aortic arch surgery using the frozen elephant trunk technique between March 2012 and July 2017. The mean age of the patients was 54.7 ± 10.5 years. Type A and Type B aortic dissections were the indications for surgery. Moderate hypothermia and antegrade cerebral perfusion via the innominate artery were utilized. The mean diameter of the implanted stent graft was 27.7 ± 2 mm (range 24–30 mm). No permanent spinal cord injuries occurred. The distal edge of the stent graft was in the T7–T12 range. Its lower edge was implanted at the T9–T12 level in 25 (67.6%) cases. Preoperatively, the mean number of intercostal arteries was 10 ± 1 on the left side and 10 ± 2 on the right side (P = 0.59). Postoperatively, the mean number of open segmental arteries was 3 ± 2 on the left and 4 ± 1 on the right (P = 0.003). The frozen elephant trunk procedure is associated with the occlusion of most (two-thirds) of the intercostal arteries. Maintenance of adequate blood flow in the subclavian and iliac arteries is an integral prerequisite for a favourable outcome. The level of the deployment of the distal edge of the stent graft does not play a defining role.
- 17 January 2018
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 26 (6) , 972-976
Open AccessThe risk of spinal cord injury during the frozen elephant trunk procedure in acute aortic dissection
The aim of the study was to access the extended occlusion of the intercostal arteries by a stent graft in the development of postoperative spinal cord injury during aortic arch surgery using the frozen elephant trunk technique. A total of 37 consecutive patients underwent total aortic arch surgery using the frozen elephant trunk technique between March 2012 and July 2017. The mean age of the patients was 54.7 ± 10.5 years. Type A and Type B aortic dissections were the indications for surgery. Moderate hypothermia and antegrade cerebral perfusion via the innominate artery were utilized. The mean diameter of the implanted stent graft was 27.7 ± 2 mm (range 24–30 mm). No permanent spinal cord injuries occurred. The distal edge of the stent graft was in the T7–T12 range. Its lower edge was implanted at the T9–T12 level in 25 (67.6%) cases. Preoperatively, the mean number of intercostal arteries was 10 ± 1 on the left side and 10 ± 2 on the right side (P = 0.59). Postoperatively, the mean number of open segmental arteries was 3 ± 2 on the left and 4 ± 1 on the right (P = 0.003). The frozen elephant trunk procedure is associated with the occlusion of most (two-thirds) of the intercostal arteries. Maintenance of adequate blood flow in the subclavian and iliac arteries is an integral prerequisite for a favourable outcome. The level of the deployment of the distal edge of the stent graft does not play a defining role.